Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEAT GAIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Electricity Pricing aware Deep Reinforcement Learning based Intelligent HVAC Control

Recently, deep reinforcement learning (DRL) based intelligent control of Heating, Ventilation, and Air Conditioning (HVAC) has gained a lot of attention due to DRL's ability to optimally control HVAC for minimizing operational cost while maintaining resident's comfort. The success of such DRL-based techniques largely depends on the articulation of the problem in terms of states, actions, and reward function. Inclusion of the electricity pricing information in the problem formulation can play an important role in saving the cost of HVAC operation. However, less attention has been given in the literature on formulating well-crafted state features based on electricity pricing. In this work, we propose an approach for training the DRL model with a specific focus on feature engineering based on electricity pricing. During training, we generate random but sufficiently realistic electricity price signals so that the pre-trained DRL model is robust and adaptive to the dynamic and variable electricity prices. The validation results are encouraging and show the potential of ≈12%-15% savings in the one day cost of HVAC operation, proving the usefulness of including electricity pricing related features as state features.

Kurte, Kuldeep↗

Advanced defrosting techniques in air source heat pumps: A review of vapor injection, thermal energy storage, and experimental frost accumulation data

Electrification is a critical step for reducing greenhouse gas emissions from heating. Air source heat pumps (ASHPs) are a promising alternative to fossil fuel-based systems due to their high coefficients of performance (COP), dual heating and cooling capability, and lower carbon footprint. However, for ASHPs to achieve widespread adoption, they must operate reliably across all climates, including cold regions. Additionally, defrosting techniques should be energy efficient and minimally disruptive to indoor comfort. Vapor injection (VI) technology can address the high-pressure and high-temperature lift challenges encountered in low ambient conditions. More recently, in addition to enhancing heating performance, VI has also been shown to improve the speed and efficiency of reverse cycle defrosting. Likewise, thermal energy storage (TES) has steadily gained attention for its ability to serve as an auxiliary heat source during both normal operation and defrosting. This review analyzes the benefits and limitations of VI- and TES-assisted defrosting approaches. While both technologies show strong potential individually, no studies to date have explored their combined use in ASHP systems. Additionally, to support continued development of defrosting strategies, both in modeling and experimental work, it is critical to establish frost accumulation data under a range of operating conditions. By compiling the available data from the literature, this paper also highlights the limited availability of such experimental data and the wide variation in frosting and defrosting durations and termination criteria, which are often influenced by system design and test setups.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of Biomass Fouling on Screw Feeder in Preconversion of Pyrolysis

Biomass is a source of renewable energy and can undergo thermochemical processes to be converted into gaseous and liquid fuels. Thermal decomposition-induced biomass fouling on the screw feeder is a major challenge in preconversion of pyrolysis, leading to plugging of the feed line. Here, this work intends to gain fundamental understanding of the biomass fouling phenomena across the heat gradient on the screw feeder via a combination of materials characterization and thermal simulation. An actual screw feeder that failed because of biomass fouling was examined to reveal the deposit’s morphology, composition, and mechanical properties. Thermal simulations were developed for both the screw feeder and the wood particles being transported using a combined analytical and numerical approach. The simulated temperature profiles correlated well with the deposit observations, based on which potential mitigations were proposed from both the operation and screw design perspectives and supported by preliminary experimental validation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developing reliable machine learning interatomic potential for Fe–Cr–Ni austenitic alloys

Gaining atomistic understanding of mechanical behavior of heat-resistant structural materials such as Fe–Cr–Ni-based alloys requires an approach with an accuracy close to density functional theory (DFT) that considers the intrinsic properties of the bulk lattice and important defects such as stacking faults, grain boundaries, and surfaces. This work aims to develop reliable machine learning interatomic potential (MLIAP) at cross-scale for Fe–Cr–Ni ternary alloys with a focus on the face-centered-cubic (fcc) solid solution structure. Leveraging the advantages of moment tensor potentials, which typically necessitate a relatively small training dataset and enable rapid calculations using the large-scale atomic/molecular massively parallel simulator package, we ensure the stability and accuracy of the trained potentials. Important defects such as stacking faults, grain boundaries, and surfaces for wide-range compositions are investigated. Structural, thermal, elastic, and defect properties are determined from molecular dynamics simulations comprising several thousand atoms, generated via canonical Monte Carlo simulations guided by the trained potential. The trained potential allows efficient atomic simulations of structural, thermal, and mechanical properties of fcc Fe–Cr–Ni solid solution alloys as a function of composition and temperature. Therefore, the MLIAP approach represents a major advancement from DFT calculations that are limited to small simulation sizes and traditional molecular dynamics simulations using relatively low accuracy potentials. Furthermore, this work outlines a practical foundation for further investigating the structural evolution and mechanical behavior of austenitic stainless steel and nickel-based alloys in a wide array of applications in extreme environments.

Crystal structure↗

A framework for calibrating and validating an air loop dynamic model in an HVAC system in Modelica

The use of Modelica for simulating the dynamic behaviors of building heating, ventilation, and air conditioning (HVAC) systems has gained popularity. Calibration of a model that represents large and complex HVAC systems in Modelica involves the determination of hundreds of parameters using real-world operation data. Considering the coupling effects among various components, such a calibration process is complex and time-consuming. In this study, we propose a systematic framework to efficiently calibrate and validate a complex HVAC system model in Modelica. The framework includes strategies to solicit real-system operation data and to decouple the model. The goal of this calibration framework is to accurately and efficiently determine a set of Modelica model parameters that provide a good match between the simulated and real system behaviors. To demonstrate the validity of the framework, it was applied to calibrate the parameters of a Modelica model of the air loop subsystem of a real AHU-VAV system. The results show that the calibrated model can generate simulated results, including VAV air flow rate, outdoor air flow, and fan power consumption, that match well with the operational data of the real system. The coefficient of the variation of the root mean square error, CV(RMSE), of the air flow rate and power consumption are 14.6 % and 11.5 %, respectively. The results prove that the framework is valid and effective, and it can be used to calibrate other complex HVAC system Modelica models in the future.

Li, Yicheng↗

CODE-TO-CODE BENCHMARK STUDY FOR THERMAL STRESS MODELING AND PRELIMINARY ANALYSIS OF THE HIGH-TEMPERATURE SINGLE HEAT PIPE EXPERIMENT

Microreactors are very small nuclear reactors with typical thermal-energy output of up to 20 MWth. The microreactor concept is gaining more and more attention for safe, robust, and reliable supply of electricity for remote locations and to meet industrial process heat needs. Heat-pipe-cooled microreactor is one of the microreactors being investigated at Idaho National Laboratory. In the heat-pipe-cooled microreactor, heat pipes remove heat from the reactor core as a passive heat-transfer device, so the fluid circulation is not required for cooling, which can substantially simplify the overall reactor design. However, given the extremely high temperatures in the core region and potentially large temperature gradients across the structure materials, thermal stresses need to be well-analyzed to ensure structural integrity during normal operations and accident scenarios for the heat-pipe-cooled microreactor designs. This paper discusses finite element method-based thermal-stress analysis for the high-temperature single heat-pipe test article in the Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory, using two commercial software packages, Abaqus and STAR-CCM+. A code-to-code benchmark study was performed to crosscheck the model setup and capability of each code and to gain insights into the potential thermal stress concerns from the current experimental setup. It is observed the significant thermal stresses happen at the locations where the largest temperature gradients appeared between heat pipe and electric heater. The temperature fields have good agreements between Abaqus and STAR-CCM+, while the induced thermal stresses show modest deviations probably due to differences of meshing engines used in these two codes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

Assessment of Screen-Covered Grooved Sodium Heat Pipes for Microreactor Applications

New nuclear reactor designs that incorporate heat pipes are being investigated for possible near-term deployment in terrestrial applications. Here, this study explores the use of screen-covered axially grooved sodium heat pipes and their applicability for providing heat removal for microreactors. A sodium working fluid is appropriate for microreactors operating in the 5 to 20 MW(thermal) range at approximately 650°C. HTPIPE, a legacy software code, was validated for the case of screen-covered grooves and used to perform steady-state analyses to determine the performance limits of a proposed heat pipe design. The performance limits of a sodium heat pipe with a screen-covered square grooved wick structure is compared to that of an equivalent heat pipe with an annular wick. In a horizontal orientation at an operating temperature of 650°C,the performance limits for the heat pipe with an annular wick configuration are 15% higher than for the screen-covered grooved wick. At operating temperatures below 777°C, the annular wick outperforms the screen-covered grooved wick, and at temperatures above 777°C, the screen-covered grooved wick outperforms the annular wick. However, the marginal performance gain at higher temperatures may not justify the use of heat pipes with a screen-covered grooved wick structure due to increased manufacturing costs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Blade and Rim Seal Design of a First Stage High Pressure Turbine for a 300 MWe Supercritical CO2 Power Cycle

A first stage high-pressure turbine (HPT) blade is optimized for a 300 MWe supercritical CO2 (sCO2) power cycle using the surrogate-assisted genetic algorithm optimizer in Numeca FINE/Design 3D with objectives of increasing efficiency and decreasing heat load to the blade. The National Institute of Standards and Technology Reference Fluid Thermodynamic and Transport Properties Database (NIST REFPROP) [1] data for supercritical CO2 is formatted into tables of bicubic polynomial coefficients for use in condensable gas simulations in FINE/Turbo. Nearly 3000 unique shapes are evaluated via three-dimensional Reynolds Averaged Navier Stokes simulations, yielding increases in efficiency of up to 0.85 percentage points and decreases in heat load of 14%. A final blade, deemed the advanced blade, is chosen for future experimental analysis. Following this, a squealer tip optimization is performed on both the baseline and advanced blade designs. This optimization resulted in a performance gain of 1.25 points in efficiency and 15% reduction in tip heat load compared to the baseline flat tip design at the same clearance. In tandem, an optimization of the rotor-stator platform rim seal is performed using a parametrized geometry allowing for straight, meandering, and knife seal cavities. This multi-objective optimization focuses on decreasing the cooling mass flow and increasing the heat flux from the rotor and stator disk. The optimization resulted in cooling mass flow decreases of up to 26% while maintaining the average heat flux on the rim seal.

Tuite, Logan↗

Progress and opportunities in corrosion mitigation in heat transfer fluids for next-generation concentrating solar power

Concentrating solar power (CSP) systems have gained considerable eminence in converting solar thermal energy into electrical power in recent years. According to the U.S. Department of Energy's Gen3 roadmap, the CSP system should operate > 700 °C, as its efficiency depends directly on the operating temperature of the heat transfer fluids (HTFs). A significant challenge, however, is the corrosion of containment materials by the HTFs that is exacerbated at the higher temperatures. A comprehensive review of the high temperature stable HTFs, their properties, corrosion mechanisms on different alloys, and corrosion mitigation measures is of much importance for directing a concerted research and development in the field, which forms the motivation for this compendium. First, molten salt HTFs and their thermophysical properties, along with liquid metals, are introduced. Corrosion of structural materials in different HTFs including molten salts, liquid metals, and supercritical carbon-di-oxide at various temperatures and the corrosion mechanisms are comprehensively reviewed. In addition, several corrosion mitigation methods are discussed. Finally, future directions for HTFs and corrosion mitigation methods in molten salts are proposed. As a result, the holistic review presented here will serve as the foundation for further research addressing relevant challenges and enabling the promise of achieving cost-competitive CSP.

14 SOLAR ENERGY↗

Summary of GNU Octave Lady Godiva Simulator

A pseudo real-time interactive reactor simulator for the Lady Godiva reactor has been developed using the GNU Octave software package. The simulator tracks the time-dependent power and fuel temperature behavior of the Lady Godiva reactor during sub-prompt critical transients. Users interact with the simulator by controlling reactivity input. This input occurs through users repositioning a control rod as desired during simulator operation. Various reactor parameters are displayed graphically in near “real time,” facilitating user assessment and feedback input. The reactor model consists of a lumped-fuel core, a single control rod, and a simple heat transfer mechanism that allows heat to be rejected from the core. The goal of the simulator is to demonstrate in real-time the system response to reactivity perturbations, the effect of reactivity feedback, and the effect of temperature-dependent equilibrium conditions. The dynamic behavior of the reactor is primarily driven by the relative characteristic time-constants between the delayed neutrons and the overall heat transfer parameter. The simulator will allow users to gain experience performing standard reactor operations, such as establishing steady-state at different fuel temperatures and making power level changes

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Progress on Computational Modeling of Water-Based NSTF (FY2021)

This report documents the FY21 progress and achievements made in the computational analyses of the water-based NSTF. Both system-level and high-fidelity Computational Fluid Dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. The progress on the waterbased NSTF experimental testing is summarized in a companion report (ANL-ART-230). As a continuation of progress from previous years, in FY21 the RELAP5 model of the NSTF was first updated to include a representative heated cavity that incorporated convection and conduction means of heat transfer. Two different cavity models were developed, one that models the radiation heat exchange among all surfaces in one enclosure (Cavity Model 1), and another that employs multiple radiation enclosures with each considering the surfaces at one axial level (Cavity Model 2). This updated RELAP5 deck was benchmarked with single-phase test data to tune form loss coefficients of the elbows and tees, along with heat transfer coefficients within the cavity and off the external insulation panels. This tuned model was then found to accurately predict fluid temperatures within 2.5% and both system and riser flow rates within 6% during single-phase, steady-state simulations. For transient simulations, there is a slight over prediction of the flow rate, fluid temperatures, and heater temperatures during the heat-up period, which indicate that the transient heat loss may be underestimated. Following, the capabilities of RELAP5-3D were examined, which feature a conduction enclosure model that is not present in the current version of RELAP5-MOD3.3 used for all previous NSTF simulations. As an initial comparison of the two codes, single-phase simulations were run that used similar input decks. The results indicate that the single-phase flow predicted by the two codes was very similar, however RELAP5-3D appears to predict a higher system flow during the two-phase transient when compared to the flow rates predicted by RELAP5-MOD3.3. Furthermore, RELAP5-3D run did not capture the density wave oscillations or geysering phenomena, which are large oscillation flow instabilities observed in the experimental facility. To further the prediction capabilities for capturing two-phase instabilities, Options 55, 57, 58, 61, which are implemented by default in RELAP5-MOD3.3 but not in RELAP5-3D, were investigated. When enabling Option 61, RELAP5-3D agrees well with MOD3.3 in predicting the total system flow, while other options have negligible effect on the predicted total system flow by RELAP5-3D. However, none of these options enables RELAP5-3D to produce the same flow instabilities. For future steps, efforts are currently underway to investigate RELAP5-3D’s different behavior in predicting low-pressure two-phase instabilities. STAR-CCM+ was used to perform CFD analysis of the water-based test facility and provide simulation results for comparisons to experimental data. Efforts first focused on describing the characteristics of flow within the heated cavity. A study was performed on whether possible leakage flow between the two sides of the cavity could substantially impact and explain the results. An additional second assumption was examined which defined adiabatic side walls, so physical insulation structures were added to the models to allow conduction across this outer insulation. The results suggest that potential porosity of the insulation could be a major factor in the temperature distribution within the cavity and should be considered in any studies where it is desirable to know the cavity wall temperatures to higher accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of Environmental and Socioeconomic Factors on Increased Early Childhood Blood Lead Levels: A Case Study in Chicago

This study analyzes the prevalence of elevated blood lead levels (BLLs) in children across Chicagoland zip codes from 2019 to 2021, linking them to socioeconomic, environmental, and racial factors. Wilcoxon tests and generalized additive model (GAM) regressions identified economic hardship, reflected in per capita income and unemployment rates, as a significant contributor to increased lead poisoning (LP) rates. Additionally, LP rates correlate with the average age of buildings, particularly post the 1978 lead paint ban, illustrating policy impacts on health outcomes. The study further explores the novel area of land surface temperature (LST) effects on LP, finding that higher nighttime LST, indicative of urban heat island effects, correlates with increased LP. This finding gains additional significance in the context of anthropogenic climate change. When these factors are combined with the ongoing expansion of urban territories, a significant risk exists of escalating LP rates on a global scale. Racial disparity analysis revealed that Black and Hispanic/Latino populations face higher LP rates, primarily due to unemployment and older housing. The study underscores the necessity for targeted public health strategies to address these disparities, emphasizing the need for interventions that cater to the unique challenges of these at-risk communities.

Lee, Jangho (ORCID:0000000289421092)↗

Impact of Thermal Barrier Coatings on Intake and Exhaust Valves in a Spark Ignition Engine

Spark ignition knock is highly sensitive to changes in intake air temperature. Hot surface temperatures due to ceramic thermal barrier coatings increase knock propensity by elevating the incoming air temperature, thus mitigating the positive impacts of low heat transfer losses by requiring spark retard to avoid knock. Low thermal inertia coatings (i.e. Temperature swing coatings) have been proposed as a means of reducing or eliminating the open cycle charge heating penalty of traditional TBCs through a combination of low thermal conductivity and low volumetric heat capacity materials. However, in order to achieve a meaningful gain in efficiency, a significant fraction of the combustion chamber must be coated. In this study, a coated piston and intake and exhaust valves with coated combustion faces, backsides, and stems are installed in a single-cylinder research engine to evaluate the effect of high coated fractions of the combustion chamber in a knock-sensitive architecture. Spark timing sweeps demonstrated a small, but notable increase in net thermal efficiency compared to the coated piston by itself. Here, a staged valve removal demonstrated that the coated intake valve prevents heat transfer to the incoming air, reducing knock propensity compared to the coated exhaust valve individually.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electron ITB formation in EAST high poloidal beta plasmas under dominant electron heating

Abstract Plasma confinement and transport in tokamaks play a crucial role in the development of high poloidal beta steady-state operation scenarios. Therefore, it is very important to study the relevant mechanism of internal transport barriers (ITBs), which can help plasmas to obtain better confinement in order to achieve higher fusion gain. This paper mainly introduces the analysis of the characteristics of electron heat transport of discharges with ITB in high β P operation regime in Experimental Advanced Superconducting Tokamak (EAST). Based on the statistical analysis of stable discharges with β P > 1.5, it is found that there is an obvious bifurcation of the normalised electron temperature gradient (ETG) ( R / L T e ) in the range of β P = 2–2.2. Then the discharges of lower β P ( β P < 2, where the value of β P is below the bifurcation threshold) and of higher β P ( β P > 2.2, where the value of β P is above the threshold) were selected for analysis. The diagnostic data provided by Thomson scattering, x-ray crystal spectrometry and charge exchange recombination spectroscopy are used to provide reliable parameter profiles and then combined with the data of external magnetic probe measurements and the polarisation interferometer diagnosis system to fully reconstruct the balance. A relevant plasma current calculation model is used to calculate and analyse the current density profiles and power deposition, and then the transport analysis is carried out. Interestingly, in the higher β P discharges, it is found that the turbulence intensity provided by the CO 2 laser collective scattering system gradually decreases and the normalised ETG R / L T e gradually increases. It is also found that the electron heat transport coefficient decreases in the discharge with higher β P and the growth rate of the electron-scale turbulence calculated by transport gyro-Landau fluid (TGLF) is significantly reduced. Meanwhile, similar conclusions are also obtained in the discharges when the β P is further increased.

Wang, Z. H. (ORCID:0009000203431036)↗

Silyl Hot-Injection Versus Thiocyanate Heat-Up Synthesis of Chalcohalides: Pushing the Size and Composition Envelope

Chalcohalide semiconductors are rapidly gaining traction as stable, biocompatible materials for energy conversion applications. While the solid-state synthesis of bulk chalcohalides is relatively well-developed, the colloidal chemistry of these materials is still in its early stages. Colloidal semiconductors are often advantageous in device fabrication due to the cost effectiveness of solution processing. Thus, we aim to increase the utility of chalcohalides in device fabrication by establishing solution phase chemistry of promising compositions. We show that silyl hot-injection is a versatile and effective method of making colloidal PnChI (Pn = Sb, Bi; Ch = S, Se) and Sn 2 PnS 2 I 3 (Pn = Sb, Bi) chalcohalides of tunable sizes and compositions. Furthermore, we demonstrate the preparation of mixed-pnictide chalcohalides through direct hot-injection and/or postsynthetic cation exchange, the latter being one of the few reported instances in chalcohalides. Additionally, we use the thiocyanate heat-up approach in combination with density functional theory to study halide mixing in quaternary tin chalcohalides. By pushing the limits of each synthetic technique, we have designed more soluble chalcohalides with tunable compositions while also gaining a better understanding of the efficacy of each procedure in respect to thin film and subsequent device fabrication. In addition to size and composition tuning, silyl hot-injection can help facilitate the future development and wide-scale application of chalcohalide-based devices by expanding the selection of solution-processable chalcohalides.

halogens↗

Analysis of convection heat transfer on multiscale rough superhydrophobic and liquid infused surfaces

Multiscale rough superhydrophobic or slippery liquid infused porous surfaces have gained much interest in recent years for their improved transport phenomena properties. While there have been several studies on drag reduction and condensation on non-wetting surfaces, convection heat transfer that is important in many thermal and thermochemical applications has not been addressed systematically. Here, this article utilizes a fractal description of rough surface topographies to develop analytical models for the Nusselt number and the thermal hydraulic factor for fluid flow and heat transfer inside a cylinder with non-wetting surfaces. For air-infused superhydrophobic surfaces, the model considers the dynamic stability of the air/fluid interface in the asperities. Using the analytical formulations and the stability criteria, systematic studies are presented on the effects of the fractal surface parameters, cylinder radius and Reynolds number on the convective heat transfer characteristics, from which surface texture design maps are developed for maximizing the convection heat transfer. It is shown that multiscale non-wetting surfaces are most effective in the range of lower Reynolds number and small cylinder radius for achieving the best convective heat transfer and thermal hydraulic performance. Applying the models to actual non-wetting surface topographies fabricated using electrodeposition and chemical etching, it is shown that contrary to prevailing notion, superhydrophobicity, characterized by the highest contact angles, does not always lead to the maximum convective heat transfer performance, and that under certain fluid flow conditions, hydrophobic surfaces may offer a greater thermal performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗