Search NASA⌕ Search

SEARCH · Search NASA

Results for “High loading rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High flux boiling heat transfer enhancement using triangle shaped vertical walls in two-phase microchannel heat exchangers

Two-phase heat exchangers allow heat loads to be dissipated with lower fluid flow rates without inducing thermal gradients, and high surface area microchannels further reduce the thermal resistance of these heat exchangers. However, there are many practical limits that prevent widespread use of two-phase microchannel heat exchangers. Many authors have looked to address these practical limits by treating the channel floors or creating artificial nucleation sites. Few works look to enhance heat transfer in the walls of channels with hydraulic diameters below 200 μm. This work is aimed at increasing the efficacy of high aspect ratio silicon microchannels that use R134a as the working fluid. The 125 parallel channels are 40 μm wide, 200 μm deep, and 2 mm long and contain a 15 μm wide, 150 μm long restriction at each inlet. The thermal resistance and dryout characteristics of traditional, plain-walled channels are compared to channels with 2 area enhancement patterns each of which increases the area available for heat transfer by 41%. Furthermore, a resistance to dryout is seen in both area-enhanced test sections, and a 15.5% reduction in thermal resistance is shown for the area-enhanced part with a 6 μm triangular pitch. Only a 7.8% performance increase is seen in the test section with a 3 μm pitch. Both area enhancement patterns induce an average 27% increase in pressure drop for all tests. Heat transfer characteristics are solved for using a finite element analysis (FEA) model. By examining heat transfer coefficients and local heat fluxes, it is postulated that the area enhancement reduces heat transfer coefficients and the performance increase is caused by increasing the number of active nucleation sites.

42 ENGINEERING↗

An effective air–liquid contactor for CO 2 direct air capture using aqueous solvents

Here, the development of a cost-effective, corrosion resistant, high-flux direct air capture (HiDAC) contactor for a solvent-based direct air capture (DAC) process is reported. Literature technoeconomic analyses suggest that the air–liquid contactor can cost over 20 % of the overall DAC plant’s annualized capital costs. To bring down the overall cost of DAC, it is imperative that an effective contactor is developed. A hybrid contactor consisting of a commercial polyvinylchloride structured packing enhanced with stainless-steel 410 random packing has been developed to provide a high surface area for air–liquid contact. The contactor geometry, wettability, corrosion resistance, pressure drop, along with its CO 2 uptake efficiency, CO 2 uptake rates, and extended loading potential using potassium sarcosinate solutions are investigated. Results show that the HiDAC contactor has a relatively high specific surface area (885 m 2 /m 3 ), which allows for CO 2 uptake efficiencies of up to 75 % and capture rates of up to 550 g of CO 2 per day for a 0.3 × 0.25 × 0.3 m contactor. The contactor also exhibits high levels of wettability and corrosion resistance with amino acid-based DAC solvents. A CO 2 uptake model was developed, and modeling results are compared to experimental data to simulate and predict the performance of the contactor in a DAC process using potassium sarcosinate solvent. The system’s overall mass transfer coefficient and theoretical pressure drop were also calculated, and these results were compared to DAC data found in literature. The results presented indicate that the HiDAC contactor is well suited for DAC due to its high specific surface area, resistance to corrosion, and high degree of wettability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of strain-rate on the response of elastomeric architected materials

Architected materials have shown substantial promise in impact mitigation and protective applications, and there has accordingly been great interest in better characterizing their response at elevated strain rates due to impact. There remains ambiguity regarding the contribution of inertial and material responses to strain rate sensitivity, and, in particular, when these effects begin to gain dominance in the impact response of an architected material. The response of soft polymer architected materials as a function of strain rate, in particular, has been little investigated. We characterize the experimental impact response of four soft polymer architected lattice geometries across varying strain rates in the intermediate strain rate regime (∼10 3 s −1 ) using split-Hopkinson pressure bar loading and high speed video characterization of the resulting deformation fields. In conclusion, our results highlight the interplay of influence between constituent material, lattice geometry, length scale, and strain rate in determining the onset of significant inertia effects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Fast‐Charging and High‐Temperature All‐Organic Rechargeable Potassium Battery

Abstract Developing fast‐charging, high‐temperature, and sustainable batteries is critical for the large‐scale deployment of energy storage devices in electric vehicles, grid‐scale electrical energy storage, and high temperature regions. Here, a transition metal‐free all‐organic rechargeable potassium battery (RPB) based on abundant and sustainable organic electrode materials (OEMs) and potassium resources for fast‐charging and high‐temperature applications is demonstrated. N‐doped graphene and a 2.8 m potassium hexafluorophosphate (KPF 6 ) in diethylene glycol dimethyl ether (DEGDME) electrolyte are employed to mitigate the dissolution of OEMs, enhance the electrode conductivity, accommodate large volume change, and form stable solid electrolyte interphase in the all‐organic RPB. At room temperature, the RPB delivers a high specific capacity of 188.1 mAh g −1 at 50 mA g −1 and superior cycle life of 6000 and 50000 cycles at 1 and 5 A g −1 , respectively, demonstrating an ultra‐stable and fast‐charging all‐organic battery. The impressive performance at room temperature is extended to high temperatures, where the high‐mass‐loading (6.5 mg cm −2 ) all‐organic RPB exhibits high‐rate capability up to 2 A g −1 and a long lifetime of 500 cycles at 70–100 °C, demonstrating a superb fast‐charging and high‐temperature battery. The cell configuration demonstrated in this work shows great promise for practical applications of sustainable batteries at extreme conditions.

25 ENERGY STORAGE↗

CO 2 Oxidative Ethane Dehydrogenation on CeO 2 /SiO 2 ‐Supported NiFe 3 Catalysts

CO 2 -assisted oxidative dehydrogenation of ethane is a sustainable alternative to steam cracking for ethylene production. In this study, a series of CeO 2 on SiO 2 supported NiFe 3 catalysts were synthesized by incipient wetness impregnation and tested for oxidative dehydrogenation performance. The CeO 2 /SiO 2 supported catalysts with high weight loading of CeO 2 (50%–75%) provided higher activity than the lower CeO 2 (0%–25%) loaded catalysts (with ethylene production rates of 0.62–0.98 µmol/g cat /s and 0.19–0.3 µmol/g cat /s, respectively) while maintaining high ethylene selectivity (43%–45%). In contrast, the NiFe 3 supported on only CeO 2 also exhibited high activity (ethylene production rate of 0.71 µmol/g cat /s), but the ethylene selectivity (16%) was greatly decreased compared to the mixed system. Temperature programmed reduction, X-ray diffraction, and Raman spectroscopy all indicate the creation of a solid solution of the Fe and Ni doped into the CeO 2 crystal structure in the catalysts with high CeO 2 loading/bulk CeO 2 support. Here, the high ethylene selectivity in the high CeO 2 loading catalysts indicates that the Fe is preferentially creating the solid solution, with the decrease in selectivity observed in the CeO 2 -only supported catalyst likely resulting from CeO 2 interacting directly with Ni, creating Ni-CeO X interfaces that are known active sites for the unwanted side reaction of dry reforming.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation of dislocation evolution in microparticle impacts over a wide range of impact velocities

We report the dynamic loading environment created by high velocity microparticle impacts is very difficult to model. The extremely high strain rates, large deformations, and high temperatures affect the flow stress of the material in ways that standard flow stress models cannot capture. Plastic deformation and strain hardening in metals is controlled by the motion of dislocations. Dislocations can be nucleated, stored as forest dislocations, or be annihilated as loading progresses. A comprehensive accounting of dislocation density change is needed to accurately describe rate and temperature dependent dislocation glide and evolution across the wide rage of loading conditions present in microparticle impact problems. Therefore, we implement and apply a newly proposed flow stress model (Hunter and Preston, 2015, 2022) that is then coupled with mobile and immobile dislocation density evolution equations. This model is implemented in Los Alamos National Laboratory’s hydrodynamics code, FLAG, to model copper-on-copper microparticle impacts. This new strength model allows for accurate simulation of particle rebound and flattening across a wide range of impact velocities.

36 MATERIALS SCIENCE↗

Modeling Advanced Strippers for CO2 Capture from Gas-Fired Power Plants using Aqueous Piperazine

Energy performance of 5 m piperazine was evaluated with an advanced stripper at the pilot scale, accounting for heat loss. Modeling studies indicated that heat loss at locations other than the heat source impacted the heat duty. For strippers with excess packing, the column was the most important source of heat loss, and values as low as 0.03 GJ/hr can cause pinch and reabsorption of CO2. Solvents like 5 m PZ are more affected by heat loss in the column due to a top-side temperature pinch at high lean loading. Heat loss impacts NGCC CO2 capture more than coal-based CO2 capture. Surface temperature measurements pilot plants showed that heat loss was 50-75% controlled by natural convection. Measured heat loss was correlated with steam flowrate and wind speed and ranged from 8126 to 219668 Btu/hr, representing 35% of the measured heat rate on average. Net heat duty linearly varied with CO2 removal at low lean loading and was similar for coal and NGCC conditions at fixed removal. At 90% removal, net heat duty was about 2.5 GJ/t with 4 and 12% CO2 in the flue gas. 7 At NGCC conditions, strippers with finite packing can benefit from a flashing feed to the top of the column by using a hot bypass. A flashing feed was linked to a reduction in irreversibility of the stripper from temperature driving forces. It also reduces heat duty by up to 6% at fixed packing height and reduces packing requirement for a fixed steam heater size compared to a warm bypass. Lean loading and lean solvent rate were effective handles to maximize profitability of a fixed stripper design at low gas price. High ambient temperature operation can benefit from low pressure stripping to about 0.18 lean loading at 150 ℃ to maintain the cyclic capacity at reduced rich loading. At low gas price, the capture plant was able to maximize profitability even with a high heat duty of 2.7-3.1 GJ/t at a lean loading of 0.2-0.22 mol/mol. Heat recovery by partial water vapor condensation in a gas-liquid exchanger can be replaced by a direct contact condenser (DCC). The DCC improved gas cooling and reduced heat duty compared to the CO2 exchanger at 0.2 lean loading. The DCC when used with a 150 ℃/5.5 bar stripper can reduce the cost of capture compared to the base case by $3- 4/tonne at 15 ft of packing (optimum) but increases cost of capture by $6/tonne with a 120 ℃/2 bar stripper and 10 ft of packing (optimum). The DCC can work effectively with a solvent with a high heat of absorption and thermal stability.

Suresh Babu, Athreya↗

Impact of Electrode Thickness and Temperature on the Rate Capability of Li 4 Ti 5 O 12 /LiMn 2 O 4 Cells

Growing demand for stationary energy storage systems requires the development of low cost, long cycle life, safe batteries. Lithium-ion batteries (LiBs) utilizing Li 4 Ti 5 O 12 /LiMn 2 O 4 (LMO) cathode are promising candidates providing critical-material-free chemistry, high power capability, and long lifespan. However, their low energy density is a major drawback. In this work, we evaluate the rate performance of LTO/LMO cells fabricated with electrode loadings from 1.7 to 4.2 mAh cm -2 toward the development of high energy density and low cost LTO/LMO cells. The operating temperature is varied from 30 °C to 55 °C to evaluate the impact of electrode thickness vs temperature limitations on the electrode utilization. In addition, Newman modeling is performed to provide detailed understandings of the cell performance. Combining experimental and simulated results, we show the rate capability of the thicker electrodes is limited by the electrolyte transport. When the cells are discharged by applying pulsed current, Li + ion depletion is mitigated and the discharge capacity increases. Thus, high energy density LTO/LMO cells for BTMS applications can operate more efficiently when intermittent rest is applied. Finally, overcoming electrolyte transport limitations will be the key to enabling the development of high energy density LTO/LMO cells using thick electrodes.

25 ENERGY STORAGE↗

Automotive fuel cell stack and system efficiency and fuel consumption based on vehicle testing on a chassis dynamometer at minus 18 °C to positive 35 °C temperatures

In this work we present an in-depth laboratory technology assessment of a 2016 Toyota Mirai Fuel Cell (FC) vehicle based on chassis dynamometer testing. The 114.6 kW FC stack has a high dynamic response, which makes this powertrain a FC-dominant hybrid electric vehicle. The measured peak efficiency is 66.0% FC stack and 63.7% FC system with an idle hydrogen flow rate of 4.39 g/hr. The high FC system efficiencies at low loads match typical vehicle power spectrums, resulting in a high average vehicle efficiency of 62% compared to 45% and 23% for a hybrid electric vehicle and a conventional vehicle, respectively. An energy breakdown accounts for the FC stack losses, FC system losses, air compressor loads, and heater loads for different drive cycles and different thermal conditions. The cold-start North American city drive cycle (UDDS) energy consumption values are, respectively, 758, 581, 226, and 321 Wh/km at ambient conditions of -18 degrees C, -7 degrees C, -25 degrees C and 35 degrees C with 850 W/m 2 of solar loading. The FC system shutdown and startup processes at temperatures below the freezing point contribute to the increased hydrogen consumption. Additionally, the raw test data files are available for download, thus providing the research community with a public reference data on a modern production automotive FC system.

08 HYDROGEN↗

Shock recompaction of spall damage

Spall fracture is a high strain-rate damage phenomenon associated with shock or impulsive loading events. When a material that has been subjected to shock compression is allowed to release, rarefaction waves propagate into the sample and reduce the internal stress to zero. If multiple rarefaction waves intersect, they generate tension which, if sufficient, can nucleate voids in the material. It has been observed in several works investigating spall fracture that although the shock-wave profiles suggested spall occurred, imaging of the recovered sample revealed no voids or cracks. In this study, we aim to determine whether a second shock event could recompact existing spall damage, and if so, what form does the microstructure at the recompaction interface have? Through a series of gas-gun flyer-plate impact experiments, we demonstrate that modest shock stresses of 2 GPa–3 GPa are enough to both fully compact a damaged copper target back to a state of zero porosity and, furthermore, drive recrystallization of the interface such that there is a new bond formed where the free surfaces were brought together.

42 ENGINEERING↗

Solar‐Driven CO 2 Conversion via Optimized Photothermal Catalysis in a Lotus Pod Structure

Abstract Photothermal CO 2 reduction is one of the most promising routes to efficiently utilize solar energy for fuel production at high rates. However, this reaction is currently limited by underdeveloped catalysts with low photothermal conversion efficiency, insufficient exposure of active sites, low active material loading, and high material cost. Herein, we report a potassium‐modified carbon‐supported cobalt (K + −Co−C) catalyst mimicking the structure of a lotus pod that addresses these challenges. As a result of the designed lotus‐pod structure which features an efficient photothermal C substrate with hierarchical pores, an intimate Co/C interface with covalent bonding, and exposed Co catalytic sites with optimized CO binding strength, the K + −Co−C catalyst shows a record‐high photothermal CO 2 hydrogenation rate of 758 mmol g cat −1 h −1 (2871 mmol g Co −1 h −1 ) with a 99.8 % selectivity for CO, three orders of magnitude higher than typical photochemical CO 2 reduction reactions. We further demonstrate with this catalyst effective CO 2 conversion under natural sunlight one hour before sunset during the winter season, putting forward an important step towards practical solar fuel production.

Wang, Hongmin↗

Solar–Driven CO 2 Conversion via Optimized Photothermal Catalysis in a Lotus Pod Structure

Photothermal CO 2 reduction is one of the most promising routes to efficiently utilize solar energy for fuel production at high rates. However, this reaction is currently limited by underdeveloped catalysts with low photothermal conversion efficiency, insufficient exposure of active sites, low active material loading, and high material cost. Herein, we report a potassium-modified carbon-supported cobalt (K + –Co–C) catalyst mimicking the structure of a lotus pod that addresses these challenges. As a result of the designed lotus-pod structure which features an efficient photothermal C substrate with hierarchical pores, an intimate Co/C interface with covalent bonding, and exposed Co catalytic sites with optimized CO binding strength, the K + –Co–C catalyst shows a record-high photothermal CO 2 hydrogenation rate of 758 mmol gcat –1 h –1 (2871 mmol gCo –1 h –1 ) with a 99.8 % selectivity for CO, three orders of magnitude higher than typical photochemical CO 2 reduction reactions. Here, we further demonstrate with this catalyst effective CO 2 conversion under natural sunlight one hour before sunset during the winter season, putting forward an important step towards practical solar fuel production.

36 MATERIALS SCIENCE↗

IM3 + EPRI Data Center Load Projections

This dataset contains scenarios of hourly total electricity demand with and without projected loads from data centers over the period 2022-2040. The root projections without data center demands are identical to those documented in Burleyson et al. 2024. In short, those projections encompass hourly electricity demands for 54 Balancing Authorities (BAs) in the United States across a range of eight of weather and socioeconomic scenarios. Refer to the root dataset and accompanying publication, Burleyson et al. 2025, for information about how those projections were generated. For this derivative dataset we used the base loads from the following scenarios: rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 The root load projections did not reflect the drastic expansion of data centers that has occurred in the last several years to support artificial intelligence and cloud computing. To reflect growth in data center demand, a second set of load projections were created in which we layered in additional data center load projections based on the data center load growth scenarios described in a 2024 report by the Electric Power Research Institute (EPRI): "Powering Intelligence: Analyzing Artificial Intelligence and Data Center Energy Consumption". The EPRI projections from the report are included in this dataset (EPRI_2024_Projections.xlsx). That report contained annual state-level data center load projections for four year-over-year growth rates for data center demands: Low (3.71% annual growth) Moderate (5% annual growth) High (10% annual growth) Higher (15% annual growth) To homogenize the load projections with and without data centers we had to get them to a common scale. The first step was to take the EPRI annual state-level data center energy consumption values and convert them to 8760-hr loads for each year. We did that by assuming a flat (e.g., not weather- or time-sensitive) load profile and distributing the data center loads in each state evenly across all hours in a year. From there the loads were downscaled from the state-level to the county-level using 2019 county-level populations as weights. Finally, the county-level hourly data center loads were summed to the BA-level using the county-to-BA mapping underpinning the root load projections. The net result is 16 (4 weather and socioeconomic scenarios crossed with 4 data center load growth scenarios) unique load projections for the period 2022-2040. The file format follows that of the root dataset with a single additional column "Scaled_TELL_BA_Load_with_DC_MWh" that contains the hourly loads with the added data center loads for a given BA-year-scenario combination. Please refer to the readme file in the root dataset for more information on the file format.

Burleyson, Casey [Pacific Northwest National Labor↗

An analysis of alcohol compression ignition strategies on different engine platforms

Strategies that enable ignition of the low cetane alcohol fuels (methanol and ethanol) include intake heating (direct or via hot residual trapping), increased compression ratio (CR), multi-injection strategies, ignition enhancers, and active prechambers. The literature consistently shows alcohol compression ignition (CI) is more efficient than diesel at high loads irrespective of ignition strategy but shows contradictory results at low loads. To understand this, this work combines data from four different engine platforms ranging from a displaced volume of 0.4 to 2.1 L/cyl. using different alcohol CI ignition strategies. Using modeling to support experimental analysis, alcohol-specific efficiency penalties are highlighted to inform alcohol combustion system development. The alcohols’ lower energy density means more fuel must be injected near top dead center to achieve a given load, increasing the relative penalty of sensible/latent heating. Pilot injections help reduce this penalty. Intake heating incurs both a heat transfer penalty and a thermodynamic penalty due to a reduced ratio of specific heats during compression. A strategy that combines elevated CR, large pilot injections, and ignition enhancers can avoid this penalty. Alternatively, a prechamber strategy can achieve this without changing the CR, nor needing ignition enhancers in the fuel. At low loads, diesel burns in a partially premixed mode characterized by high burn rates and low heat losses, reducing alcohol-specific combustion benefits. Alcohol CI on the light-duty platform showed abnormally high heat transfer over diesel compared to other platforms, favoring a more premixed/partially premixed strategy despite a combustion efficiency tradeoff.

33 ADVANCED PROPULSION SYSTEMS↗

Multimodal 3D characterization of voids in shock-loaded tantalum: Implications for ductile spallation mechanisms

Predicting the failure of crystalline materials at high strain rates requires knowledge of the underlying failure mechanisms and their dependence on microstructure. However, little experimental consensus exists on the underlying micromechanics of spallation. In this study, a 3D-EBSD characterization experiment is performed on tantalum prior to and after partial spallation by plate impact, which allowed for the statistical assessment of the microstructural neighborhoods surrounding incipient voids. In analyzing the resulting dataset containing 5884 grains and 467 voids, it is observed that the voids were roughly spherical and consistent in size throughout the spalled material. The voids mostly resided at quadruple points, at triple junctions, at grain boundaries, and within grains, in decreasing order of prevalence. Moreover, voids tended to form at grain boundaries with high degrees of plastic incompatibility, growing into the plastically soft grain but orienting primarily with or perpendicular to the loading direction. Here, the statistics from these analyses of 3D microstructural data support dynamic cavitation models for ductile spallation.

36 MATERIALS SCIENCE↗

Nitrate Removal Across Ecogeomorphic Zones in Wax Lake Delta, Louisiana (USA)

Human activities have increased nitrate export from rivers, degrading coastal water quality. At deltaic river mouths, the flow of water through wetlands increases nitrate removal, and the spatial organization of removal rates influences coastal water quality. To understand the spatial distribution of nitrate removal in a river-dominated delta, in this study we deployed 23 benthic chambers across ecogeomorphic zones with varying elevation, vegetation, and sediment properties in Wax Lake Delta (Louisiana, USA) in June 2018. Regression analyses indicate that normalized difference vegetation index is a useful predictor of summertime nitrate removal. Mass transfer velocity were approximately three times greater on a vegetated submerged levee (13 mm hr –1 ), where normalized difference vegetation index was greatest, compared to other locations (4.6 mm hr –1 ). Two methods were developed to upscale nitrate removal across the delta. The flooded-delta method integrates spatially explicit potential removal rates across submerged portions of the delta and suggests that intermediate elevations on the delta—including submerged levees—are responsible for 70% of potential nitrate removal despite covering only 33% of the flooded area. The channel network method treats the delta as a network of river channels and suggests that although secondary channels are more efficient than primary channels at removing received nitrate, primary channels collectively contribute more to overall removal because they convey more of the total nitrate load. The two upscaling methods predict similar rates of nitrate removal, equivalent to less than 4% of nitrate entering the delta. To protect coastal waters against high nitrate loads, management policies should aim to reduce upstream nutrient loads.

54 ENVIRONMENTAL SCIENCES↗

Impact of biomass burning aerosols on radiation, clouds, and precipitation over the Amazon: relative importance of aerosol–cloud and aerosol–radiation interactions

Biomass burning (BB) aerosols can influence regional and global climate through interactions with radiation, clouds, and precipitation. Here, we investigate the impact of BB aerosols on the energy balance and hydrological cycle over the Amazon Basin during the dry season. We performed simulations with a fully coupled meteorology–chemistry model, the Weather Research and Forecasting model coupled with Chemistry (WRF-Chem), for a range of different BB emission scenarios to explore and characterize nonlinear effects and individual contributions from aerosol–radiation interactions (ARIs) and aerosol–cloud interactions (ACIs). The ARIs of BB aerosols tend to suppress low-level liquid clouds by local warming and increased evaporation and to facilitate the formation of high-level ice clouds by enhancing updrafts and condensation at high altitudes. In contrast, the ACIs of BB aerosol particles tend to enhance the formation and lifetime of low-level liquid clouds by providing more cloud condensation nuclei (CCN) and to suppress the formation of high-level ice clouds by reducing updrafts and condensable water vapor at high altitudes (>8 km). For scenarios representing the lower and upper limits of BB emission estimates for recent years (2002–2016), we obtained total regional BB aerosol radiative forcings of –0.2 and 1.5 W m –2 , respectively, showing that the influence of BB aerosols on the regional energy balance can range from modest cooling to strong warming. We find that ACIs dominate at low BB emission rates and low aerosol optical depth (AOD), leading to an increased cloud liquid water path (LWP) and negative radiative forcing, whereas ARIs dominate at high BB emission rates and high AOD, leading to a reduction of LWP and positive radiative forcing. In all scenarios, BB aerosols led to a decrease in the frequency of occurrence and rate of precipitation, caused primarily by ACI effects at low aerosol loading and by ARI effects at high aerosol loading. The dependence of precipitation reduction on BB aerosol loading is greater in a strong convective regime than under weakly convective conditions. Overall, our results show that ACIs tend to saturate at high aerosol loading, whereas the strength of ARIs continues to increase and plays a more important role in highly polluted episodes and regions. This should hold not only for BB aerosols over the Amazon, but also for other light-absorbing aerosols such as fossil fuel combustion aerosols in industrialized and densely populated areas. The importance of ARIs at high aerosol loading highlights the need for accurately characterizing aerosol optical properties in the investigation of aerosol effects on clouds, precipitation, and climate.

54 ENVIRONMENTAL SCIENCES↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗