Search NASA⌕ Search

SEARCH · Search NASA

Results for “High spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High spatial resolution thermal conductivity mapping of SiC/SiC composites

Herein, silicon carbide (SiC) ceramic matrix composites are being investigated as a new generation of fuel cladding materials due to its higher accident tolerance compared to Zircaloy. Characterization of the thermal conductivity of SiC constituents and their interfaces and interphases in SiC/SiC composites is needed as inputs to models of cladding performance. We used time-domain thermoreflectance (TDTR) to map the thermal conductivity with a spatial resolution of 2 µm. The SiC/SiC composite is comprised of Hi-Nicalon Type S fibers in a matrix made by chemical vapor infiltration (CVI matrix). The interphase material is a pyrolytic carbon/SiC multilayer. We report thermal conductivity maps of the SiC fiber and SiC matrix at temperatures of 25 °C, 90 °C, 164 °C, and 250 °C. The fiber has a uniform and isotropic thermal conductivity of 22 W m -1 K -1 at 25 °C; the thermal conductivity of fiber is approximately independent of temperature. The matrix thermal conductivity is not uniform and varies from 50 to 120 W m -1 K -1 at 25 °C; the thermal conductivity of the matrix scales approximately with the inverse of the square root of temperature, i.e., ∝ 1/T 1/2 . The thermal conductivity of the interphase at room temperature is 6 W m -1 K -1 . The calculated spatially averaged thermal conductivity of this SiC/SiC composite at 1000°C is 29 W m -1 K -1 .

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Achieving high spatial resolution using a microchannel plate detector with an economic and scalable approach

We report a second generation position-sensitive microchannel plate detector using the induced signal approach has been realized. This detector is presently capable of measuring the incident position of electrons, photons, or ions. To assess the spatial resolution, the masked detector was illuminated by electrons. The initial, measured spatial resolution of 276 μm FWHM was improved by requiring a minimum signal amplitude on the anode and by employing digital signal processing techniques. The resulting measured spatial resolution of 119 μm FWHM corresponds to an intrinsic resolution of 98 μm FWHM when the effect of the finite slit width is de-convoluted. This measurement is a substantial improvement from the last reported spatial resolution of 466 μm FWHM using the induced signal approach. To understand the factors that limit the measured resolution, the performance of the detector is simulated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mapping protein dynamics at high spatial resolution with temperature-jump X-ray crystallography

Understanding and controlling protein motion at atomic resolution is a hallmark challenge for structural biologists and protein engineers because conformational dynamics are essential for complex functions such as enzyme catalysis and allosteric regulation. Time-resolved crystallography offers a window into protein motions, yet without a universal perturbation to initiate conformational changes the method has been limited in scope. Here we couple a solvent-based temperature jump with time-resolved crystallography to visualize structural motions in lysozyme, a dynamic enzyme. We observed widespread atomic vibrations on the nanosecond timescale, which evolve on the submillisecond timescale into localized structural fluctuations that are coupled to the active site. An orthogonal perturbation to the enzyme, inhibitor binding, altered these dynamics by blocking key motions that allow energy to dissipate from vibrations into functional movements linked to the catalytic cycle. Because temperature jump is a universal method for perturbing molecular motion, the method demonstrated here is broadly applicable for studying protein dynamics.

59 BASIC BIOLOGICAL SCIENCES↗

A high spatial resolution land surface phenology dataset for AmeriFlux and NEON sites

Abstract Vegetation phenology is a key control on water, energy, and carbon fluxes in terrestrial ecosystems. Because vegetation canopies are heterogeneous, spatially explicit information related to seasonality in vegetation activity provides valuable information for studies that use eddy covariance measurements to study ecosystem function and land-atmosphere interactions. Here we present a land surface phenology (LSP) dataset derived at 3 m spatial resolution from PlanetScope imagery across a range of plant functional types and climates in North America. The dataset provides spatially explicit information related to the timing of phenophase changes such as the start, peak, and end of vegetation activity, along with vegetation index metrics and associated quality assurance flags for the growing seasons of 2017–2021 for 10 × 10 km windows centred over 104 eddy covariance towers at AmeriFlux and National Ecological Observatory Network (NEON) sites. These LSP data can be used to analyse processes controlling the seasonality of ecosystem-scale carbon, water, and energy fluxes, to evaluate predictions from land surface models, and to assess satellite-based LSP products.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement of derivative of ion temperature using high spatial resolution charge exchange spectroscopy with space modulation optics

A new technique to measure the first and second derivatives of the ion temperature profile has been developed by using a charge exchange spectroscopy system with space modulation optics. The space observed is scanned up to {+-}3 cm with a cosine wave modulation frequency up to 30 Hz by shifting the object lens in front of the optical fiber bundle by 0.5 mm with a piezoelement. The first and second derivatives of ion temperature are derived from the modulation component of the ion temperature measured by using Fourier series expansion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of a high spatial resolution method based on polar coordinate maximum entropy method for analyzing electron density fluctuation data measured by laser phase contrast

Laser phase contrast is a powerful diagnostic method to determine the spatial distribution of electron density fluctuations in magnetically confined plasmas, although its applicability depends on magnetic field configurations. The spatial resolution of fluctuations is linked with the resolution of the propagation direction that is derived from the two-dimensional spectral analysis of the wavenumber for the fluctuations. The method was applied to fluctuation measurements in a compact helical system. In order to improve the resolution of the propagation direction with a relatively small number of data points, the maximum entropy method with polar coordinates was employed. A spatial resolution of the order of 1 cm was obtained, which is satisfactory in a plasma with a 20 cm minor radius.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved strain precision with high spatial resolution using nanobeam precession electron diffraction

NanoBeam Electron Diffraction is a simple and efficient technique to measure strain in nanostructures. Here, we show that improved results can be obtained by precessing the electron beam while maintaining a few nanometer probe size, i.e., by doing Nanobeam Precession Electron Diffraction (N-PED). The precession of the beam makes the diffraction spots more uniform and numerous, making N-PED more robust and precise. In N-PED, smaller probe size and better precision are achieved by having diffraction disks instead of diffraction dots. Precision in the strain measurement better than 2 × 10{sup −4} is obtained with a probe size approaching 1 nm in diameter.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Taheri-Saramad x-ray detector (TSXD): A novel high spatial resolution x-ray imager based on ZnO nano scintillator wires in polycarbonate membrane

A novel x-ray imager based on ZnO nanowires is designed and fabricated. The proposed architecture is based on scintillation properties of ZnO nanostructures in a polycarbonate track-etched membrane. Because of higher refractive index of ZnO nanowire compared to the membrane, the nanowire acts as an optical fiber that prevents the generated optical photons to spread inside the detector. This effect improves the spatial resolution of the imager. The detection quantum efficiency and spatial resolution of the fabricated imager are 11% and <6.8 μm, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of vertically aligned ZnO-nanowires scintillators for high spatial resolution x-ray imaging

Newly designed scintillator of (0001)-oriented ZnO vertical nanowires (vnws) for X-ray imaging was prepared on a Ga-doped ZnO/soda-lime glass by electrodeposition, and the light emission feature was estimated in a synchrotron radiation facility. The ZnO-vnws scintillator revealed a strong light emission and improved resolution on CMOS image compared with that for the ZnO-layer scintillator, although the light emission performance was deteriorated in comparison to the Lu{sub 3}Al{sub 5}O{sub 12:}Ce{sup 3+}. The light emission property closely related to the nanostructure and the resultant photoluminescence characteristic.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantitative x-ray magnetic circular dichroism mapping with high spatial resolution full-field magnetic transmission soft x-ray spectro-microscopy

The spectroscopic analysis of X-ray magnetic circular dichroism (XMCD), which serves as strong and element-specific magnetic contrast in full-field magnetic transmission soft x-ray microscopy, is shown to provide information on the local distribution of spin (S) and orbital (L) magnetic moments down to a spatial resolution of 25 nm limited by the x-ray optics used in the x-ray microscope. The spatially resolved L/S ratio observed in a multilayered (Co 0.3 nm/Pt 0.5 nm) × 30 thin film exhibiting a strong perpendicular magnetic anisotropy decreases significantly in the vicinity of domain walls, indicating a non-uniform spin configuration in the vertical profile of a domain wall across the thin film. Quantitative XMCD mapping with x-ray spectro-microscopy will become an important characterization tool for systems with topological or engineered magnetization inhomogeneities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A method to measure the thermovoltage with a high spatial resolution

We have recorded spatial maps of the thermovoltage of a Au(111) surface with a scanning tunneling microscope. The method relies on an approach where we record quasi-simultaneously the normal topography as well as the thermovoltage by switching the feedback and sample bias on and off. This setup can be combined with standard scanning tunneling microscopy and scanning tunneling spectroscopy techniques. The thermovoltage, which arises from a temperature difference between scanning tunneling microscope tip and sample, is very sensitive to small variations of the local electronic density of states in vicinity of the Fermi level. Near step edges we have observed well-defined Friedel oscillations, while for the herringbone reconstruction, small variations of the local work-function are measured. By altering the tip-sample distance, the thermovoltage contrast can be adjusted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PIND: High spatial resolution by pinhole neutron diffraction

Here, a pinhole neutron diffraction (PIND) technique was developed to enable improving the spatial resolution down to 250 μm. Instead of the conventional engineering diffraction method which integrates all the diffraction signals on the detector plane, the PIND setup utilizes the diffraction pattern of each pixel on 2D detectors. The proposed PIND arrangement enables improving the spatial resolution of time-of-flight instruments and allows solving problems involving steep gradients of strain or texture. The phase content and preferential orientation of grains inside samples can be spatially resolved in 2D/3D. Further, PIND retains the capability of in-situ non-destructive neutron diffraction mapping of lattice strain and grain orientation under external stimuli such as temperature and force.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HIGH SPATIAL RESOLUTION IMAGING OF THERMAL EMISSION FROM DEBRIS DISKS

We have obtained subarcsecond mid-IR images of a sample of debris disks within 100 pc. For our sample of 19 A-type debris disk candidates chosen for their IR excess, we have resolved, for the first time, five sources plus the previously resolved disk around HD 141569. Two other sources in our sample have been ruled out as debris disks since the time of sample selection. Three of the six resolved sources have inferred radii of 1-4 AU (HD 38678, HD 71155, and HD 181869), and one source has an inferred radius {approx}10-30 AU (HD 141569). Among the resolved sources with detections of excess IR emission, HD 71155 appears to be comparable in size (r {approx} 2 AU) to the solar system's asteroid belt, thus joining {zeta} Lep (HD 38678, reported previously) to comprise the only two resolved sources of that class. Two additional sources (HD 95418 and HD 139006) show spatial extents that imply disk radii of {approx}1-3 AU, although the excess IR fluxes are not formally detected with better than 2{sigma} significance. For the unresolved sources, the upper limits on the maximum radii of mid-IR disk emission are in the range {approx}1-20 AU, four of which are comparable in radius to the asteroid belt. We have compared the global color temperatures of the dust to that expected for the dust in radiative equilibrium at the distances corresponding to the observed sizes or limits on the sizes. In most cases, the temperatures estimated via these two methods are comparable, and therefore, we see a generally consistent picture of the inferred morphology and the global mid-IR emission. Finally, while our sample size is not statistically significant, we note that the older sources (>200 Myr) host much warmer dust (T {approx}> 400 K) than younger sources (in the tens of Myr).

79 ASTRONOMY AND ASTROPHYSICS↗

A HIGH SPATIAL RESOLUTION STUDY OF THE {lambda} = 3 mm CONTINUUM OF ORION-KL

Recent interferometric observations have called into question the traditional view of the Orion-KL region, which displays one of the most well-defined cases of chemical differentiation in a star-forming region. Previous lower-resolution images of Orion-KL show emission signatures for oxygen-bearing organic molecules toward the Orion Compact Ridge and emission for nitrogen-bearing organic molecules toward the Orion Hot Core. However, more recent observations at higher spatial resolution indicate that the bulk of the molecular emission arises from many smaller, compact clumps that are spatially distinct from the traditional Hot Core and Compact Ridge sources. It is this type of observational information that is critical for guiding astrochemical models, as the spatial distribution of molecules and their relation to energetic sources will govern the chemical mechanisms at play in star-forming regions. We have conducted millimeter-imaging studies of Orion-KL with various beam sizes using the Combined Array for Research in Millimeter-Wave Astronomy in order to investigate the continuum structure. These {lambda} = 3 mm observations have synthesized beam sizes of {approx}0.''5-5.''0. These observations reveal the complex continuum structure of this region, which stands in sharp contrast to the previous structural models assumed for Orion-KL based on lower spatial resolution images. The new results indicate that the spatial scaling previously used in determination of molecular abundances for this region are in need of complete revision. Here we present the results of the continuum observations, discuss the sizes and structures of the detected sources, and suggest an observational strategy for determining the proper spatial scaling to accurately determine molecular abundances in the Orion-KL region.

79 ASTRONOMY AND ASTROPHYSICS↗

HIGH SPATIAL RESOLUTION X-RAY SPECTROSCOPY OF THE IC 443 PULSAR WIND NEBULA AND ENVIRONS

Deep Chandra ACIS observations of the region around the putative pulsar, CXOU J061705.3+222127, in the supernova remnant (SNR) IC 443 reveal an ∼5″ radius ring-like structure surrounding the pulsar and a jet-like feature oriented roughly north–south across the ring and through the pulsar's location at 06{sup h}17{sup m}5.{sup s}200 + 22°21′27.″52 (J2000.0 coordinates). The observations further confirm that (1) the spectrum and flux of the central object are consistent with a rotation-powered pulsar, (2) the non-thermal spectrum and morphology of the surrounding nebula are consistent with a pulsar wind, and (3) the spectrum at greater distances is consistent with thermal emission from the SNR. The cometary shape of the nebula, suggesting motion toward the southwest, appears to be subsonic: There is no evidence either spectrally or morphologically for a bow shock or contact discontinuity; the nearly circular ring is not distorted by motion through the ambient medium; and the shape near the apex of the nebula is narrow. Comparing this observation with previous observations of the same target, we set a 99% confidence upper limit to the proper motion of CXOU J061705.3+222127 to be less than 44 mas yr{sup −1} (310 km s{sup −1} for a distance of 1.5 kpc), with the best-fit (but not statistically significant) projected direction toward the west.

79 ASTRONOMY AND ASTROPHYSICS↗