Search NASA⌕ Search

SEARCH · Search NASA

Results for “High temperature performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

How Cation Migration across a 2D/3D Interface Dictates Perovskite Solar Cell Efficiency

Perovskite solar cells with 2D/3D architecture are claimed to exhibit better stability compared to pristine 3D films at room temperature. However, under illumination and/or heat, cation migration causes the exchange of the bulky spacer cations (2D phase) with the smaller A-site cations (3D phase), creating a gradient heterostructure at the 2D/3D interface. We have evaluated the performance of BA 2 MAPb 2 I 7 /MAPbI 3 (2D/3D) and MAPbI 3 (3D) solar cells at different temperatures, while simultaneously probing the absorption changes of the 2D/3D perovskite layer and the photovoltaic performance of solar cell devices. The 2D/3D solar cells were more stable at room temperature but exhibited deterioration of photovoltaic performance at high temperatures. Here, by employing in situ measurements of operating solar cells to track both the photoconversion efficiency and absorption changes at different temperatures, we show that the cation exchange at the 2D/3D interface contributes to the efficiency losses.

14 SOLAR ENERGY↗

Online Lead/Water Heat Exchanger Sensor/System Feasibility-PNNL (Final Report)

On-line structural health corrosion monitoring in advanced lead fast reactor heat exchangers and molten salt reactor heat exchangers is desirable for detecting tube degradation prior to leaks that may allow mixing of heat exchanger fluids or release of radiological contamination beyond the design containment boundary. This program, On-Line Lead/Water Heat Exchanger Sensor/System Feasibility – PNNL 76092, demonstrates feasibility for an ultrasonic torsional wave mode sensor attached to the outside of a long (30.5-m) heat exchanger tube in the stagnant flow area where the tube joins a heat exchanger plenum and where it is possible to protect a sensor and cable from high-force flows. The sensor must be cable connected to a monitoring instrument near the heat exchanger. The sensor and cable management approach for periodic in-service inspection will be impractical to implement on existing heat exchangers; rather permanently mounted sensors must be installed in conjunction with heat exchanger fabrication. Previous work has shown low-temperature lead zirconate titanate (PZT) piezoceramic sensors are able to detect anomalies of interest in 3.0-m long tubes. These sensors have hereby been extended to a 30.5-m long tube more representative of commercial power heat exchanger designs. The program will continue to investigate higher temperature piezoelectric ceramics and long-term performance of high temperature adhesives and sealants and mechanical pressure coupling for 350-500 °C lead reactor environments and higher temperature (700 °C) molten salt environments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Temperature-dependent Battery Performance of a Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT Cathode and In-situ Heat Generation on Cycling

Excellent structural stability, high operating voltage, and high capacity have made Na 3 V 2 (PO 4 ) 2 F 3 a promising cathode material for sodium-ion batteries. However, high-temperature battery performances and heat generation measurements have not been systematically reported yet. Carbon-coated Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT (multi-walled carbon nanotube) samples are fabricated by a hydrothermal-assisted sol-gel method and the electrochemical performances are evaluated at three different temperatures (25, 45, and 55 °C). Furthermore, the well-crystallized Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT samples exhibit good cycling stability at both low and high temperatures; they deliver an initial discharge capacity of 120–125 mAhg -1 at a 1 C rate with a retention of 53 % capacity after 1,400 cycles with 99 % columbic efficiency. The half-cell delivers a capacity of 100 mAhg -1 even at a high rate of 10 C at room temperature. Furthermore, the Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT samples show good long-term durability; the capacity loss is an average of 0.05 % per cycle at a 1 C rate at 55 °C. Additionally, ionic diffusivity and charge transfer resistance are evaluated as functions of state of charge, and they explain the high electrochemical performance of the Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT samples. In-situ heat generation measurements reveal reversible results upon cycling owing to the high structural stability of the material. Excellent electrochemical performances are also demonstrated in the full-cell configuration with hard carbon as well as antimony Sb/C anodes.

25 ENERGY STORAGE↗

High Temperature Mechanical Behavior of Refractory Alloys with Digital Image Correlation

Gas turbine efficiency is typically limited by the maximum allowable temperature for components at the inlet side and in the hot gas flow. Refractory alloys and SiC/SiC ceramic-matrix composites (CMCs) are promising candidates for advancing operating temperatures beyond those of Ni-based alloys (>1200 °C). Refractory alloys are more suitable than SiC/SiC CMCs for dynamic components, due to the latter's low toughness and ductility. However, it is well known that refractory alloys suffer from poor oxidation behavior under service lifetimes and conditions, leading to embrittlement concerns. The ARPA-E ULTIMATE program has set out to combine new alloys with advanced coatings to mitigate oxidation/embrittlement effects, while increasing the mechanical performance benefits of refractory materials. Low oxygen (inert gas) or vacuum systems are needed to assess high temperature mechanical performance of developed alloys. To investigate the environmental sensitivity of candidate alloys and develop high temperature testing capabilities, four argon tensile frames were upgraded as well as a single vacuum system at Oak Ridge National Laboratory. Digital image correlation was incorporated into the vacuum frame allowing for surface strain determination and refined insight into thermomechanical response. Creep testing was performed at 1300 °C on two alloys, C-103 and MHC in vacuum and high purity argon environments. The Mo-based alloy showed less sensitivity to oxygen, indicating that testing in well-controlled argon environments may be suitable. The C-103 alloy demonstrated a stronger sensitivity to oxygen in the well-controlled argon environment, illustrating the need for the developed vacuum testing capabilities. “Small” 25 mm and “large” 76 mm MHC specimens showed comparable results in terms of strain rate during creep testing and ultimate tensile strength during tensile testing, suggesting the viability of smaller geometries that use less material of advanced developmental alloys.

Bell, Sam↗

Methane foam performance in oil-wet unconsolidated porous media: A systematic experimental investigation at reservoir conditions

Methane foam performance was systematically evaluated using high-pressure and high-temperature experiments performed on oil-wet proppant packs. The sensitivities of foam performance to various key factors, including surfactant concentration, foam quality, total injection rate, salinity, operating pressure, and initial oil saturation were examined. The results showed that even though the foamability and foam strength in oil-wet proppant packs were adversely affected by wettability and presence of oil, the steady-state pressure drops across the proppant packs were insensitive to the quantity of oil initially present. The presence of oil above the critical oil saturation impeded the onset of foam generation. This suggested that the foamability of surfactants depends on the synergetic effects of surfactant’s ionic nature and foam parameters, such as foam quality and total injection rate, on their ability to reduce the oil saturation to a threshold value below which favorable bubble generation sites could be created. It was observed that, for low injection rate, anionic surfactant was ineffective at low salinity conditions, while amphoteric agent performed well at all salinities. Additionally, an increase in salinity resulted in enhanced pressure drop across the proppant packs for both anionic and amphoteric surfactants. Further, the results also established that too high operating pressures are somewhat detrimental to the foam strength and stability, irrespective of the ionic nature of foaming agents and the wettability of the porous medium. For the anionic surfactant, the increase in the total flow rate was found to mitigate the adverse effects of low salt concentration and operating pressure. Results from quality-sensitivity foam tests identified two regions for the foam behavior, named low-quality and high-quality regimes, separated by the transition foam quality. Finally, we discuss the implications of the results for the design and effective implementation of enhanced oil recovery (EOR) schemes that deploy hydrocarbon-based foams.

02 PETROLEUM↗

A Novel High-Temperature Generator/Motor Design: With Applications in Geothermal Drilling and Other Industries

The National Renewable Energy Laboratory (NREL), in partnership with Tetra Corporation and TPL Inc, has an ongoing ARPA-E project related to an advanced high-temperature geothermal drilling system, and the power electronics necessary for this system. As part of this work, NREL designed, built and tested a high-temperature generator for power generation in a 250 degrees Celsius downhole drilling environment. This design exceeded initial performance targets at elevated temperature. NREL is investigating alternative applications for this design, as either a generator or motor capable of efficient performance at high temperature.

alternator↗

Recent trends in all-organic polymer dielectrics for high-temperature electrostatic energy storage capacitors

Electrostatic energy storage (EES) capacitors are critical for renewable energy and high-power systems, driving the search for dielectric materials that combine superior electrical insulation, mechanical flexibility, low density, cost-effectiveness, and processability. Polymer-based dielectrics have emerged as leading candidates, particularly for high electric field applications. However, conventional polymers often fail to meet the demands of high-temperature environments due to increased electrical conductivity and reduced discharged energy density at elevated temperatures, resulting in energy loss and reduced performance. High glass transition temperature (T g) polymers show promise but require further optimization to enhance their energy storage capabilities under thermal and electrical stress. This review provides a comprehensive update on recent advancements in high-T g polymer-based dielectrics for EES capacitors, focusing on both intrinsic polymers and all-organic composites. It outlines key design principles, critical performance parameters, and innovative strategies—such as nanofiller doping, layered architectures, physical blending, and chemical crosslinking—to improve electrical, thermal, and mechanical properties. The review also highlights emerging trends, including the integration of machine learning algorithms to explore novel polymer structures and expand the chemical design space. By bridging the gap between academic research and industrial application, this review aims to accelerate the development of next-generation dielectric materials capable of balancing multiple performance metrics for high-temperature EES capacitors.

Xie, Zongliang↗

Effect of Carbon Support Heat Treatment on the Performance of Ion-Pair High-Temperature PEM Fuel Cells

Heat treatment can significantly alter the physical and chemical properties of carbon supports, thereby influencing the performance of proton exchange membrane (PEM) fuel cells. This study explores how varying carbon heat treatment temperatures—from 1,000 °C to 2,200 °C—affect the structure and performance of platinum-based catalysts in high-temperature PEM fuel cells. Increasing the heat treatment temperature led to a notable decrease in surface area, along with increases in carbon grain size and hydrophobicity. Although the catalyst supported on carbon treated at 1,000 °C exhibited the highest catalyst activity, the MEA using carbon treated at 1,500 °C delivered the best overall fuel cell performance. This is attributed to an optimized balance between hydrophobicity and accessible surface area, which enhances water management and catalyst utilization. These findings underscore the importance of carbon support engineering in improving the efficiency of ion-pair high-temperature PEM fuel cells.

08 HYDROGEN↗

Effect of Strain on the Resistivity and Thermal Conductivity of High Purity Niobium

High purity niobium (Nb) is a technologically important material for large-scale accelerator and nano-scale quantum computing applications in microwave frequency range. The high thermal conductivity and low resistivity of Nb are critical to the high performance at temperature range of 0.01–4.0 K. The presence of interstitials such as O, N, H, and C act as scattering centers and alter the mean free path, reducing resistivity and thermal conductivity, and contributing significantly to Nb's thermal performance for temperatures of 2.0 K and above. The residual resistivity ratio (RRR), defined as the ratio of the normal state resistivity at 300 K to that at 4.2 K (Nb, T c = 9.2 K), is an accepted direct estimate of the impurity content of fully recrystallized Nb. Complete re-crystallization of Nb is challenging unless very high temperatures are employed, which is often impractical, hence, in practice, dislocation and dislocation structures impact the thermal performance of Nb due to strong phonon scattering contributions. Furthermore, this paper reports on the degradation of thermal conductivity and RRR of high purity Nb large grain, single crystal with fixed impurity, varying strain, and dislocation content levels. Experimental thermal conductivity data fits the Boltzmann transport equation incorporating dislocation density.

36 MATERIALS SCIENCE↗

Review of HAYNES® 282® alloy for supercritical CO2 structural applications

In this paper, HAYNES® 282® alloy (282® alloy) properties, microstructure, high temperature oxidation resistance, weldability, and American Society of Mechanical Engineers (ASME) code case highlights are reviewed. The long term performance of high temperature, high strength, creep resistant alloys is critical to the success of supercritical carbon dioxide equipment. Several modern power generation technologies require alloys that can operate continuously at or above 700oC. 282® alloy is a precipitation strengthened nickel based super alloy that meets these requirements. The results of 282® alloy research reviewed in this paper include longterm cyclic oxidation behavior in air and sCO2, independent research and validation of 100k hour creep life, and successful welding of the alloy in the age hardened condition. The latter is critical for joining of hardened components (flanges, piping, heat exchanger internal, etc.) and field repair. Several highlights from the code case for this ASMEapproved material are also presented.

Tossey, Brett↗

Semi-Annual Report for Horizontal Compact High Temperature Gas Reactor (HC-HTGR) Development during Performance Period October 2022-March 2023

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary heat transport system to ensure temperatures in the reactor systems, structures and components with significant safety margins during normal operation and design basis accident scenarios. This third semi-annual report summarized the progress made at Argonne on the two tasks during the first half of FY23. As a part of the RCCS design task, a design process for the water panel and the system configuration was performed to improve the thermal performance of the RCCS. The updated water panel design had achieved enhanced thermal performance with 0.96 MWth capability with major design updates made in structural interfaces with the RPV and initial configuration of the water tanks. The loop configuration of the RCCS has been proposed to have two independently working loops for system redundancy. A water panel material study was performed focusing on the use of carbon steel in water systems. Additional modeling strategies of primary system thermal fluids analyses were developed to meet modeling needs that are not well suited for the 1D-3D assembly level approach. The first of these is a reduced order assembly model, in which fuel centered unit cells are used to represent a fuel assembly. The 2D approach used in this model is much more computationally efficient, making this model useful for full core transient scenarios where fuel to coolant heat transfer is still the dominant flow path. The next model is the 3D core conduction model to be used to analyze decay heat removal in loss of primary system flow scenarios. Because these scenarios require a large domain to be modeled, a homogenized core model is being pursued to reduce the required computational costs. To accurately model decay heat scenarios it is necessary to couple a RCCS model to the 3D core conduction model. A simplified case is presented to demonstrate how the coupling methodology will be applied to the full core 3D conduction model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Semi-Annual Report for Horizontal Compact High Temperature Gas Reactor (HC-HTGR) Development during Performance Period April 2023 – September 2023

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary coolant system to ensure temperatures within the core remain below safety margins during steady-state and potential accident scenarios. This fourth semi-annual report summarized the progress made at Argonne on the two tasks during the second half of FY23. As a part of the RCCS design task, recent efforts have been made to complete a conceptual design of the RCCS for the HC-HTGR, including the design update of the water panel and system configuration favorable in point of view of fabrication and system operation. Design calculations were conducted under various heat load conditions to validate the system design. Transient simulations using RELAP5-3D were conducted to investigate system dynamics under transients of interest and to evaluate the system performance in the design condition. The results demonstrated the overall system feasibility that the RCCS design maintains structures temperatures lower than maximum allowable temperature with sufficient system inventory without any active heat sink. In the primary system thermal hydraulics task, the preliminary analysis was performed for a long term pressurized conduction cooldown (PCC) transient. This analysis used a combination of a fully resolved and coarse homogenized mesh to predict the temperature distribution for the steady-state initial condition and the PCC transient. The steady-state initial condition was determined using a fully resolved full core model with 3D solid to 1D fluid coupling. The fully resolved mesh was also used to model the first 20 seconds of the PCC. The temperature difference between fuel pins and the graphite matrix becomes minimal and the dominant heat transfer shifts to a larger scale radially towards the RCCS. After 20 seconds, a homogenized coarse mesh is used, greatly reducing the computational costs of the model. These results demonstrate that the core is designed to passively remove enough decay heat in a protected loss of primary coolant flow to prevent an unsafe rise of core temperatures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enhancement of EM Pump Performance through Modeling and Testing

Liquid sodium has seen development as a nuclear reactor coolant in the United States for over 50 years. While sodium has many desirable characteristics as a heat transfer fluid, its reactivity poses numerous engineering challenges for even the most basic plant components like pumps. Despite the challenges, mechanical pumps have seen success in sodium service albeit at the expense of simplicity and flexibility. In fact, significant failures of these pumps have been recorded which can be attributed to their complexity. Notwithstanding the complexity, mechanical pumps are still widely proposed for the main circuit pump of sodium cooled reactors. However, an alternative to mechanical pumps are Electromagnetic Induction Pumps (EMIPs) which use the principle of the Lorentz Force. EMIPs avoid mechanically moving parts in contact with sodium which simplifies the design by avoiding mechanical wear and seals. Therefore, these pumps are generally safer and more reliable than their mechanical counterparts. That being said, EMIPs suffer from relatively low efficiencies that range from 5% to 45%. Some of the inefficiencies are inherent to the EMIPs pumps; namely, inefficiencies arise in the form of resistive heating losses in the fluid itself. However, other inefficiencies arise from Edge Effects which include Finite Length and Finite Width effects. Due to the significant safety advantages EMIPs have compared to mechanical pumps, there is a strong motivation to integrate these technologies into the design of Generation IV liquid-metal-cooled nuclear power plants. However, EMIPs have low efficiencies partly attributed to Edge Effects. Much of the literature focusing on Edge Effects is dated or simply does not exist in the public domain. More recently, numerical models of EMIPs have shown promising results. However, these models are often custom solvers or use complex software suits which limit their application. This report describes the work completed to understand Edge Effects in two EMIPs designs. These designs are the Annular Linear Induction Pump (ALIP) and Permanent Magnet Induction Pump (PMIP) also known as a Moving Magnet Pump (MMP). The methodology developed during this project aim at measuring key performance parameters (pressure-flowrate and efficiency-slip performance) using high temperature liquid-sodium. Baseline experimental measurements were then used to verify the accuracy of numerical models developed in the software suit ANSYS/FLUENT. On the experimental side, instrumentation was developed to characterize the pressure-flowrate and efficiency-slip performance of both the ALIP and PMIP in high-temperature liquid-sodium. Additionally, instrumentation was developed to measure potential output pressure pulsations and the magnetic field distributions. Moreover, a specialized ALIP was constructed to study the impacts magnetic field tapering, also known as coil grading, on the Finite Length Effect. Lastly, experimental performance curves of the PMIP were collected at 300 oC and 600 oC and compared to analytical theory which accounted for Finite Width Effects. These results showed that the Finite Width Effect and non-uniform magnetic field in a PMIP impact the performance. On the numerical side, models were developed using the software suit FLUENT/ANSYS. These methods were initially compared against a simple MHD flow in a Permanent Magnet Electromagnet Flowmeter (PMEMFM). The results were significant in that they showed agreeance between the numerical model and demonstrated that PMEMFM’s could be calibrated numerically. These modeling methods were then applied to a prototypic PMIP. Results showed that this simple model provided reasonably accurate results of the PMIP p-Q performance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-temperature compressive creep tests of U 3 Si 2 with spark plasma sintering: Experiments and finite element modeling

This paper reports a systematic high-temperature creep behavior of dense U 3 Si 2 pellets using a spark plasma sintering (SPS) apparatus at elevated temperatures and pressures under vacuum conditions. The stress exponent was subsequently derived to be 3.21 at 1173 K and 2.17 at 1223 K, respectively, indicating a grain boundary sliding creep mechanism. The creep activation energy was determined to be 203.6 ± 19.0 kJ/mol, which agrees well with the literature. Finite element modeling was performed using the creep parameters fitted from the strain-time plot. Additionally, the results suggest an excellent match with the experimental data, confirming the validity of the experiments. Microstructure characterizations indicate that the main phase of the specimens after creep tests remains to be U 3 Si 2 , with a 4 μm thick layer of nano-sized particles induced from the diffusion between U 3 Si 2 and alumina disc used to avoid electric current passing through the sample. The successful conduct of creep experiments demonstrates the great potential of SPS to perform high-temperature mechanical testing of nuclear fuels under vacuum conditions. The subsequent finite element modeling exhibits excellent capabilities for accurately predicting material performance in the creep tests and provides a practical tool in evaluating nuclear fuels’ performance for a much-extended time scale.

36 MATERIALS SCIENCE↗

Interfacial Engineering Using Covalent Organic Frameworks in Polymer Composites for High‐Temperature Electrostatic Energy Storage

Abstract The use of inorganic nanofillers has been an effective method to improve high‐temperature capacitive performance of dielectric polymers, though there are unmet challenges such as undesirable organic–inorganic compatibility, and low efficiencies and energy densities. Herein, a surface functionalization strategy using covalent organic frameworks (COFs) is employed to address such challenges in realizing high‐performing polymer composites. Specifically, core–shell structured nanoparticles, where ZrO 2 nanoparticles act as the core and a COF material forms the shell, are constructed and composited with the polyetherimide (PEI) matrix. The design leverages the high electron affinity ( E A ) of the outer COF shell to create energy traps, thereby capturing free charges and limiting electrical conduction. Concurrently, the low E A and wide bandgap of the ZrO 2 core introduce energy barriers to impede charge injection and migration. This orchestrated “energy level cascade” results in a marked reduction of leakage current and energy loss. The resulting polymer composite showcases an impressive discharged energy density of 6.21 J cm −3 at an efficiency above 90%, with a maximum discharged energy density reaching 7.43 J cm −3 at 150 °C. These performance metrics position the PEI/ZrO 2 @COF polymer composite to surpass or be on par with state‐of‐the‐art high‐temperature PEI composites and other advanced polymer dielectrics.

Xie, Zongliang↗

Correcting for digital image correlation speckle inversion at high temperature using color cameras

Digital image correlation (DIC) is a popular, noncontacting technique to measure full-field deformation by using cameras to track the motion of an applied surface pattern. Because it is noncontacting, DIC can be performed for extreme temperature applications (e.g., hot-fire rocket testing of carbon composite rocket nozzles) under harsh conditions during which bonded gauges are damaged. Speckle pattern inversion is a phenomenon that sometimes occurs while performing high-temperature DIC. During speckle pattern inversion, portions of the surface pattern that were initially darker at room temperature (e.g., graphite) may emit more light due to blackbody radiation than the portions that were initially paler, thereby producing images in which the pattern appears inverted at high temperature relative to the initial pattern at room temperature. This phenomenon can prevent the correlation algorithm from being able to resolve the displacements between images. This work compares three methods to mitigate speckle pattern inversion: (A) the subtraction method, a recently-published technique in which two high-temperature images are subtracted to remove unwanted light; (B) the filtering method, a popular technique in which optical bandpass filters screen out unwanted light; and (C) the histogram rescaling method, a proposed new method that pairs a color camera with a blue light source and uses information from the green sensor of the camera to correct against inversion in the blue sensor through postprocessing. The histogram rescaling method is shown to successfully eliminate speckle pattern inversion and has the added advantages that it does not require quasi-static loading to be able to compensate for speckle pattern inversion, nor does it impose thick-glass distortions caused by the optical filter.

Rowley, Lindsey J.↗

Roll-To-Roll Atomic Layer Deposition of Titania Nanocoating on Thermally Stabilizing Lithium Nickel Cobalt Manganese Oxide Cathodes for Lithium Ion Batteries

Conformal coating of ceramic layers (nm-thick) on Ni-rich layered cathode materials is an effective strategy for improving high-temperature longevity of Li-ion batteries (LIBs). In this work, we develop a roll-to-roll atomic layer deposition (R2R ALD) apparatus for growing uniform nanolayers of TiO 2 . We explore the effect of ALD parameters (temperature: 120–180 °C and line speed: 2–40 mm s –1 ) on the TiO 2 surface coating and subsequently investigate the electrochemical performance of the as-prepared cathodes. The capacity retention of TiO 2 -coated porous electrodes is substantially improved compared to that of the pristine cathode material for high-temperature cycling. Electrochemical impedance spectroscopy confirms that the ALD-TiO 2 coating suppresses the undesired side reactions initiated at the electrode/electrolyte interface, reduces charge transfer resistance, and ultimately facilitates the Li + transport through the composite cathode nanostructure. The robust design of the ALD-TiO 2 cathode material enables high-temperature operation (>55 °C) with enhanced specific capacity, superior rate capability, excellent cyclability, and ultra-high coulombic efficiency within a wide potential window (3.0–4.35 V). Furthermore, the R2R ALD technique developed in this work paves the way for large-scale fabrication of ceramic-coated cathode sheets with a production rate reaching 2.4 m min –1 for a continuous coating operation.

25 ENERGY STORAGE↗

Resilient high-temperature reverse osmosis desalination membranes

Conventional thin-film composite (TFC) reverse osmosis (RO) membranes experience irreversible performance loss at high temperatures, restricting their use in industries with high-temperature streams, including oil and gas, pharmaceuticals, electronics, power generation, food production, and hybrid desalination plants. However, the mechanisms driving the performance decline of TFC membranes at high temperatures remain poorly understood. Herein, we combine controlled experiments, molecular dynamics simulations, and micromechanical modeling to elucidate TFC failure mechanisms and to evaluate thermally resilient thin-film cross-linked (TFX) composite membrane. Upon exposure to elevated temperatures (>60°C), salt rejection of TFC dropped from ~99 to <90%, with irreversible structural damage in the polysulfone layer, confirmed by scanning electron microscopy. In contrast, the TFX membrane maintained ~99% salt rejection and showed no signs of physical degradation up to 80°C. Our combined analyses revealed that TFC membrane failure arises from irreversible pore expansion in the thermoplastic polysulfone support, leading to polyamide film rupture and delamination. TFX membranes resist thermal deformation, enabling ultrahigh-temperature RO desalination and water reuse.

Wu, Jishan [Rice Univ., Houston, TX (United States↗