Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inhalation Dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Preliminary Preclosure Accident Consequence Analysis for the APM Conceptual Design - 18090

The Nuclear Waste Management Organization (NWMO) is implementing Adaptive Phased Management (APM), Canada's plan for the long-term management of used nuclear fuel. The APM approach encompasses centralized containment and isolation of the used fuel in a Deep Geological Repository (DGR) in a suitable rock formation, such as crystalline rock or sedimentary rock, in an informed and willing host. This paper describes a preliminary analysis of the potential dose consequences to the public under accident conditions associated with the operation of a DGR and related surface processing facilities. These results are for a generic site and considers exposure to a person standing at a potential fenceline location under conservative atmospheric conditions. Radiological dose consequences to the public were calculated for accidents identified in the preliminary hazard identification. The presence or absence of ventilation system HEPA filters was also considered in combination with specific accident scenarios. A Gaussian dispersion model considering the most stable atmospheric condition (Pasquill stability category F) was used to estimate the exposure of a member of the public in the direct plume path at the location of maximum airborne radionuclide concentrations. The public dose was calculated via the inhalation, air immersion and ground exposure pathways. For all accidents considered, the calculated public dose was low, up to about 0.8 mSv for a fall of an UFTP with container breach. The total dose to the public was also calculated at various distances from the Used Fuel Packaging Plant, Ventilation Shaft, and Main Shaft. For all accidents considered, the calculated dose to the public was low, below 1 mSv even at the minimum 100 m distance evaluated. Sensitivity cases were also carried out to determine the effect of stack release height, the effluent exit velocity, and the release orientation on the calculated minimum site boundary distance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Inhibition of chlorine-induced pulmonary inflammation and edema by mometasone and budesonide

Chlorine gas is a widely used industrial compound that is highly toxic by inhalation and is considered a chemical threat agent. Inhalation of high levels of chlorine results in acute lung injury characterized by pneumonitis, pulmonary edema, and decrements in lung function. Because inflammatory processes can promote damage in the injured lung, anti-inflammatory therapy may be of potential benefit for treating chemical-induced acute lung injury. We previously developed a chlorine inhalation model in which mice develop epithelial injury, neutrophilic inflammation, pulmonary edema, and impaired pulmonary function. This model was used to evaluate nine corticosteroids for the ability to inhibit chlorine-induced neutrophilic inflammation. Two of the most potent corticosteroids in this assay, mometasone and budesonide, were investigated further. Mometasone or budesonide administered intraperitoneally 1 h after chlorine inhalation caused a dose-dependent inhibition of neutrophil influx in lung tissue sections and in the number of neutrophils in lung lavage fluid. Budesonide, but not mometasone, reduced the levels of the neutrophil attractant CXCL1 in lavage fluid 6 h after exposure. Mometasone or budesonide also significantly inhibited pulmonary edema assessed 1 day after chlorine exposure. Chlorine inhalation resulted in airway hyperreactivity to inhaled methacholine, but neither mometasone nor budesonide significantly affected this parameter. The results suggest that mometasone and budesonide may represent potential treatments for chemical-induced lung injury. - Highlights: • Chlorine causes lung injury when inhaled and is considered a chemical threat agent. • Corticosteroids may inhibit lung injury through their anti-inflammatory actions. • Corticosteroids inhibited chlorine-induced pneumonitis and pulmonary edema. • Mometasone and budesonide are potential rescue treatments for chlorine lung injury.

60 APPLIED LIFE SCIENCES↗

Magnitude of Residual Internal Anatomy Motion on Heavy Charged Particle Dose Distribution in Respiratory Gated Lung Therapy

Purpose: To assess the variation in carbon beam dose distribution due to residual motion in lung cancer patients undergoing respiratory-gated radiotherapy. Methods and Materials: A total of 11 lung cancer patients underwent four-dimensional computed tomography with a 256-multislice computed tomography scanner under free-breathing conditions. A compensating bolus was designed to cover the treatment beam for all planning target volumes during a 30% duty cycle centered on exhalation (gating window). This bolus was applied to the four-dimensional computed tomography data for one respiratory cycle, and then the carbon beam dose distribution was calculated. Results: A water equivalent pathlength variation of <5 mm was observed in the gating window, but this increased to {<=}20 mm on inhalation. As a result, beam overshoot/undershoot occurred around inhalation, which increased the excessive dosing to normal tissues and the organs at risk. The dose for >95% volume irradiation is dependent on the respiratory phase but not the gating window. However, the dose for >95% volume irradiation correlated well with the tumor displacement distance. More than 90% of the dose for >95% volume irradiation could be delivered in the gating window with <4-mm tumor displacement resulting from exhalation. Conclusion: The results of our study have shown that even when the treatment beam delivery occurs outside the gating window, the prescribed dose to the target is not affected in patients with a tumor displacement of <4 mm. Thus, respiratory gating is not required in radiotherapy for patients with <4-mm tumor displacement in a respiratory cycle.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiological Safety Analysis Computer (RSAC) Program Version 7.4 Users’ Manual

The Radiological Safety Analysis Computer (RSAC) Program Version 7.4 (RSAC-7) is the newest version of the RSAC legacy code. RSAC-7 calculates the consequences of a release of radionuclides to the atmosphere. Users generates a fission product inventory from either reactor operating history or a nuclear criticality event. RSAC-7 models the effects of high-efficiency particulate air filters or other cleanup systems and calculates the decay and ingrowth during transport through processes, facilities, and the environment. Doses are calculated for inhalation, air immersion, ground surface, ingestion, and cloud gamma pathways. RSAC-7 is used as a tool to evaluate accident conditions in emergency response scenarios, radiological sabotage events, and safety basis accident consequences. This users’ manual contains the mathematical models and operating instructions for RSAC-7. Instructions, screens, and examples are provided to guide the user through the functions provided by RSAC-7. This program is designed for users who are familiar with radiological dose assessment methods.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of radon concentration in some water samples belonging to some adjoining areas of Pathankot, Punjab

The study of radon concentration was measured in some areas of Pathankot district, Punjab, India, from the health hazard point of view due to radon. The exposure to radon through drinking water is largely by inhalation and ingestion. RAD 7, an electronic solid state silicon detector (Durridgeco., USA) was used to measure the radon concentration in drinking water samples of the study area. The recorded values of radon concentration in these water samples are below the recommended limit by UNSCEAR and European commission. The recommended limit of radon concentration in water samples is 4 to 40 Bq/l given by UNSCEAR [1] and European commission has recommended the safe limit for radon concentration in water sample is 100 Bq/l [2].

54 ENVIRONMENTAL SCIENCES↗

Aerial Survey Results for 131I Deposition on the Ground after the Fukushima Daiichi Nuclear Power Plant Accident

In March 2011 the second largest accidental release of radioactivity in history occurred at the Fukushima Daiichi nuclear power plant following a magnitude 9.0 earthquake and subsequent tsunami. Teams from the U.S. Department of Energy, National Nuclear Security Administration Office of Emergency Response performed aerial surveys to provide initial maps of the dispersal of radioactive material in Japan. The initial results from the surveys did not report the concentration of 131I. This work reports on analyses performed on the initial survey data by a joint Japan-US collaboration to determine 131I ground concentration. This information is potentially useful in reconstruction of the inhalation and external exposure doses from this short-lived radionuclide. The deposited concentration of 134Cs is also reported.

Fukushima, I-131, aerial survey↗

Radiological Safety Analysis Computer Program V 7.2

Users generates a fission product inventory from either reactor operating history or a nuclear criticality event. RSAC-7 models the effects of high-efficiency particulate air filters or other cleanup systems and calculates the decay and ingrowth during transport through processes, facilities, and the environment. Doses are calculated for inhalation, air immersion, ground surface, ingestion, and cloud gamma pathways. RSAC-7 is used as a tool to evaluate accident conditions in emergency response scenarios, radiological sabotage events, and safety basis accident consequences.

Jordan, RobertaA. [Idaho National Laboratory (INL)↗

Toxicity Values for Chemicals

The toxicity values for chemicals contained in this dataset comprise acute, subchronic, and chronic exposure durations. Cancer slope factors, inhalation unit risk, reference dose, and reference concentrations are available. These values should be used in cancer risk and noncancer hazard assessments for the calculation of preliminary remediation goals (PRGs) and hazard characterization. Users can select toxicity values from 10 combinations of exposure durations and cancer/noncancer toxicity values and select up to 1000 chemicals per query. The dataset supports environmental risk assessments, regulatory decision-making, and environmental planning with tools for benchmarking against risk-based standards. This structured approach ensures a robust evaluation of environmental risks tailored to regulatory needs.

Stewart, Debra [Oak Ridge National Laboratory (ORN↗

Development of a rhesus monkey lung geometry model and application to particle deposition in comparison to humans

The exposure-dose-response characterization of an inhalation hazard established in an animal species needs to be translated to an equivalent characterization in humans relative to comparable doses or exposure scenarios. Here, the first geometry model of the conducting airways for rhesus monkeys is developed based upon CT images of the conducting airways of a 6-month-old male, rhesus monkey. An algorithm was developed for adding the alveolar region airways using published rhesus morphometric data. The resultant lung geometry model can be used in mechanistic particle or gaseous dosimetry models. Such dosimetry models require estimates of the upper respiratory tract volume of the animal and the functional residual capacity, as well as of the tidal volume and breathing frequency of the animal. The relationship of these variables to rhesus monkeys of differing body weights was established by synthesizing and modeling published data as well as modeling pulmonary function measurements on 121 rhesus control animals. Deposition patterns of particles up to 10 µm in size were examined for endotracheal and and up to 5 µm for spontaneous breathing in infant and young adult monkeys and compared to those for humans. Deposition fraction of respirable size particles was found to be higher in the conducting airways of infant and young adult rhesus monkeys compared to humans. Due to the filtering effect of the conducting airways, pulmonary deposition in rhesus monkeys was lower than that in humans. Finally, future research areas are identified that would either allow replacing assumptions or improving the newly developed lung model.

Asgharian, Bahman↗

DOC-WMF - A Generic Model for Assessment of Waste Disposal Facilities - 19278

Numerical models and computer codes play an important role in the safety assessment of nuclear waste disposal facilities, as well as in the regulatory review of proponents' safety assessments. An important part of a safety assessment is the radiation dose calculation. This paper presents a computer code called DOC-WMF for calculating radiation dose from nuclear waste disposal facilities. DOC-WMF is a generic code that could be used for dose calculations for deep geological or near surface disposal facilities of nuclear wastes. DOC-WMF is much faster than complicated 3-D numerical models in terms of computational speed since the model uses the commercial code GoldSim as the computation engine which is based on analytical solutions for contaminant transport. As a result, it enables a user to quickly assess the dose consequences of multiple options or scenarios for a nuclear waste disposal facility. DOC-WMF was adapted from, and an improvement to, the Scoping of Options and Analyzing Risk (SOAR) model developed by the United States Nuclear Regulatory Commission (US NRC). A key improvement over the SOAR model is that DOC-WMF allows the calculation of dose contributions from other pathways such as food ingestion and air inhalation in addition to the drinking water pathway which is the sole dose contribution considered in the SOAR model. DOC-WMF also allows for: the consideration of 55 radionuclides with option to add more if required; the choice of source release method; various pathways to the biosphere; and dose calculations including an extended array of exposure pathways. In addition, DOC-WMF can simulate more complex hydrogeological settings and waste forms than SOAR does. DOC-WMF was compared against known analytical solutions for verification. It was then applied to two test cases and the results were compared. The first was a hypothetical deep geological disposal repository. The second test case was a near-surface nuclear waste disposal facility. DOC-WMF independently modeled these two test cases and achieved similar results as the more complicated numerical models did. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Subject-specific modeling framework for particle deposition using computational fluid dynamics

Quantifying particle deposition and dose in the respiratory tract requires a physiologically realistic representation and reproducible computational workflows. However, existing modeling frameworks, such as the International Commission on Radiological Protection (ICRP) compartmental models and the Multiple Path Particle Dosimetry (MPPD) tool, lack detailed deposition profiles and subject-specific capabilities. The combination of advances in computer vision algorithms applied to the respiratory tract and Computational Fluid and Particle Dynamics (CFPD) allows high-fidelity simulations of particle behavior in anatomically accurate geometries derived from individual CT scans. The segmentation, preprocessing, and file preparation task for a CFPD simulation was often time-consuming, and no prior studies to-date have yet presented a fully automated framework. This work presents a fully automated workflow to obtain individualized particle deposition profiles in the human respiratory tract. The pipeline starts with segmenting upper and lower airway geometries using morphological and deep learning-based methods, generating three-dimensional (3D) models from CT imaging data. Next, a series of algorithms are presented to quality check and prepare the 3D geometry for a CFD or CFPD simulation. The preprocessing step includes correcting geometric artifacts, enforcing a physically consistent mesh, and automatically identifying and capping multiple outlets, which is required for CFD/CFPD simulations. These processed models are then input into open-source (OpenFOAM) or commercial (StarCCM+) CFD solvers, where flow and transient particle transport equations — including turbulence and particle–wall interactions are solved under realistic breathing conditions. Finally, the resulting particle deposition profiles can be integrated with Monte Carlo radiation transport codes and state-of-the-art computational phantoms to assess organ-specific absorbed doses in scenarios of radioactive aerosol inhalation. The presented work streamlines respiratory tract segmentation, preprocessing for CFD/CFPD simulations, and integration with dose assessment workflows, reducing manual intervention and improving access to high-fidelity, subject-specific modeling. The high precision in predicted particle deposition and dose distributions can improve personalized treatment strategies in respiratory medicine and refine dose estimates for radiation protection.

AI↗

RAIS ICRP 107 Dose Conversion Factors for Radionuclides

Radionuclide dose conversion factors, also known as dose coefficients, are used for radionuclide dose calculations. Routes included are oral, inhalation, and external exposure. Separate datasets are maintained for ICRP 107, 60, and 30. The dose conversion factors from the ICRP 107 (https://rais.ornl.gov/cgibin/tools/TOX_search?select=rad107) are updated values from FGR 13 supplement using ICRP 107 decay data. The derivation and values are in “Calculations of Slope Factors and Dose Coefficients” (ORNL, 2014).

Noto, Katie [Oak Ridge National Laboratory (ORNL),↗

RAIS ICRP 30 Dose Conversion Factors for Radionuclides

Radionuclide dose conversion factors, also known as dose coefficients, are used for radionuclide dose calculations. Routes included are oral, inhalation, and external exposure. Separate datasets are maintained for ICRP 107, 60, and 30. The dose conversion factors from ICRP 30 (https://rais.ornl.gov/cgibin/tools/TOX_search?select=rad30) can be found in FGR 11. Results from all three tools can be downloaded in .xlsx format.

Noto, Katie [Oak Ridge National Laboratory (ORNL),↗

RAIS ICRP 60 Dose Conversion Factors for Radionuclides

Radionuclide dose conversion factors, also known as dose coefficients, are used for radionuclide dose calculations. Routes included are oral, inhalation, and external exposure. Separate datasets are maintained for ICRP 107, 60, and 30. The dose conversion factors from ICRP 60 (https://rais.ornl.gov/cgi-bin/tools/TOX_search?select=rad60) can be found in FGR 12. Results from all three tools can be downloaded in .xlsx format.

Noto, Katie [Oak Ridge National Laboratory (ORNL),↗

Maxine Onsite: Estimating Dose from Chronic Atmospheric Radioactive Releases

Maxine Onsite: Developed to estimate dose to individuals who are working onsite but are not site employees. Follows the methodologies discussed in US NRC Regulatory Guides 1.109 and 1.111 to determine dose from a chronic atmospheric release. Determines the dose given relative air concentrations and deposition concentrations as input. We look at four locations onsite that may be accessed by members of the public. To show compliance with the EPA and DOE public dose limit of 10 mrem/yr, determining who is a member of the public or a worker onsite is necessary. SRS has defined a member of the public for NESHAPS and DOE O 458.1. Maxine Onsite runs on Microsoft Windows Operating System through a Microsoft Excel spreadsheet. Input from the user includes parameters that are variable such as air concentrations, and fixed, such as distance to the receptor and elemental iodine fraction. Maxine Onsite was developed from Maxine which is a program meant to calculate dose to the MEI via three pathways, external, inhalation, and ingestion. Maxine Onsite is meant for looking at the exposure through the external and inhalation pathways only, no local food production onsite. The ways that Maxine Onsite is used to calculate the dose to the MEI includes the following: - Determining the respective air concentration values at each location using distances from the release stack; - Breathing rates for the MEI; - Determining the amount of time the MEI is outside; - Determining the plume travel time. The following relative air and ground deposition values for proper execution of the spreadsheet come from MAXDOSE-SR and are needed to accurately determine the dose to the MEI: relative air concentration, relative air concentration decayed by 2.26 days, relative air concentration decayed and depleted for 8 days, and relative deposition. Test cases were designed, developed, and executed to determine the accuracy of Maxine Onsite, which were verified additionally through hand calculations. Several changes were made for testing, including varying air concentrations, distances, breathing rates, and shielding factors. Each test case was then verified through hand calculations to assure the accuracy of the calculated doses. The results from the test cases, as well as the default parameters, can be used for benchmarking Maxine Onsite in the future. Maxine Onsite performs as expected and produces correct and accurate results at each of the different locations onsite (TRL, B-Area Barracks, SRELCC, and Gunsite 51) for varying test cases. The input required by the user is minimal and includes the results of the dose to the MEI on the first page for ease of access. Future plans for Maxine Onsite include adding in the ingestion pathway and adding in atmospheric dispersion estimates to the spreadsheet.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WE-G-BRE-06: New Potential for Enhancing External Beam Radiotherapy for Lung Cancer Using FDA-Approved Concentrations of Cisplatin Or Carboplatin Nanoparticles Administered Via Inhalation

Purpose: This study investigates, for the first time, the dose enhancement to lung tumors due to cisplatin nanoparticles (CNPs) and carboplatin nanoparticles (CBNPs) administered via inhalation route (IR) during external beam radiotherapy. Methods: Using Monte Carlo generated 6 MV energy fluence spectra, a previously employed analytic method was used to estimate dose enhancement to lung tumor due to radiation-induced photoelectrons from CNPs administered via IR in comparison to intravenous (IV) administration. Previous studies have indicated about 5% of FDA-approved cisplatin concentrations reach the lung tumor via IV. Meanwhile recent experimental studies indicate that 3.5–14.6 times higher concentrations of CNPs can reach the lung tumors by IR compared to IV. Taking these into account, the dose enhancement factor (DEF) defined as the ratio of the dose with and without CNPs was calculated for field size of 10 cm × 10 cm (sweeping gap), for a range of tumor depths and tumor sizes. Similar calculations were done for CBNPs. Results: For IR with 3.5 times higher concentrations than IV, and 2 cm diameter tumor, clinically significant DEF values of 1.19–1.30 were obtained for CNPs at 3–10 cm depth, respectively, in comparison to 1.06–1.09 for IV. For CBNPs, DEF values of 1.26–1.41 were obtained in comparison to 1.07–1.12 for IV. For IR with 14.6 times higher concentrations, higher DEF values were obtained e.g. 1.81–2.27 for CNPs. DEF increased with increasing field size or decreasing tumor size. Conclusions: Our preliminary results indicate that major dose enhancement to lung tumors can be achieved using CNPs/CBNPs administered via IR, in contrast to IV administration during external beam radiotherapy. These findings highlight a potential new approach for radiation boosting to lung tumors using CNPs/CBNPs administered via IR. This would, especially, be applicable during concomitant chemoradiotherapy, potentially allowing for dose enhancement while minimizing normal tissue toxicities.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRA-08: Simulated Tumor Tracking in An MRI Linac for Lung Tumor Lesions Using the Monaco Treatment Planning System

Purpose: To simulate tumor tracking in an Elekta MRI-linac (MRL) and to compare this tracking method with our current ITV approach in terms of OAR sparing for lung cancer patients. Methods: Five SABR-NSCLC patients with central lung tumors were selected for reasons of potential enhancement of tumor-tissue delineation using MRI. The Monaco TPS was used to compare the current clinical ITV approach to a simulated, novel tracking method which used a 7MV MRL beam in the presence of an orthogonal 1.5 T magnetic field (4D-MRL method). In the simulated tracking scenario, achieved using the virtual couch shift (VCS), the PTV was defined using an isotropic 5mm margin applied to the GTV of each phase, as acquired from an 8-phase amplitude-binned 4DCT. These VCS plans were optimized and weighted on each phase. The dose weighting was performed using the patient-specific breathing traces. The doses were accumulated on the inhale phase. The two methods were compared by assessing the OAR DVHs. Results: The 4D-MRL method resulted in a reduced target volume (by an average of 29% over all patients). The benefits of using an MRL tracking system depended on the tumor motion amplitude and the relative OAR motion (ROM) to the target. The reduction in mean doses to parallel organs was up to 3 Gy for the heart and 2.1 Gy for the lung. The reductions in maximum doses to serial organs were up to 9.4 Gy, 5.6 Gy, and 8.7 Gy for the esophagus, spinal cord, and the trachea, respectively. Serial organs benefited from MRL tracking when the ROM was ≥ 0.3 cm despite small tumor motion amplitude in some cases. Conclusions: This work demonstrated the potential benefit for an MRL tracking system to spare OARs in SABR-NSCLC patients with central tumors. The benefits are embodied in the target volume reduction. This project was made possible with the financial support of Elekta.

60 APPLIED LIFE SCIENCES↗