Search NASA⌕ Search

SEARCH · Search NASA

Results for “Large deviations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Uniform modelling of the stellar density of thirteen tidal streams within the Galactic halo

ABSTRACT We present the results of fitting a flexible stellar stream density model to a collection of thirteen streams around the Milky Way, using photometric data from DES, DECaLS, and Pan-STARRS. We construct density maps for each stream and characterize their tracks on the sky, width, and distance modulus curves along the length of each stream. We use these measurements to compute lengths and total luminosities of streams and identify substructures. Several streams show prominent substructures, such as stream broadening, gaps, large deviations of stream tracks, and sharp changes in stream densities. Examining the group of streams as a population, as expected we find that streams with globular cluster progenitors are typically narrower than those with dwarf galaxy progenitors, with streams around 100 pc wide showing overlap between the two populations. We also note the average luminosity of globular cluster streams is significantly lower than the typical luminosity of intact globular clusters. The likely explanation is that observed globular cluster streams preferentially come from lower luminosity and lower density clusters. The stream measurements done in a uniform manner presented here will be helpful for more detailed stream studies such as identifying candidate stream members for spectroscopic follow up and stellar stream dynamical modelling.

79 ASTRONOMY AND ASTROPHYSICS↗

Scaling functions for eigenstate entanglement crossovers in harmonic lattices

For quantum matter, eigenstate entanglement entropies obey an area law or log-area law at low energies and small subsystem sizes and cross over to volume laws for high energies and large subsystems. This transition is captured by crossover functions, which assume a universal scaling form in quantum critical regimes. We demonstrate this for the harmonic lattice model, which describes quantized lattice vibrations and is a regularization for free scalar field theories, modeling, e.g., spin-0 bosonic particles. In one dimension, the ground-state entanglement obeys a log-area law. For dimensions d ≥ 2, it displays area laws, even at criticality. The distribution of excited-state entanglement entropies is found to be sharply peaked around subsystem entropies of corresponding thermodynamic ensembles in accordance with the eigenstate thermalization hypothesis. Numerically, we determine crossover scaling functions for the quantum critical regime of the model and do a large-deviation analysis. We show how infrared singularities of the system can be handled and how to access the thermodynamic limit using a perturbative trick for the covariance matrix. Eigenstates for quasi-free bosonic systems are not Gaussian. Here, we resolve this problem by considering appropriate squeezed states instead. For these, entanglement entropies can be evaluated efficiently.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distinct universality classes of diffusive transport from full counting statistics

The hydrodynamic transport of local conserved densities furnishes an effective coarse-grained description of the dynamics of a many-body quantum system. However, the full quantum dynamics contains much more structure beyond the simplified hydrodynamic description. Here we show that systems with the same hydrodynamics can nevertheless belong to distinct dynamical universality classes, as revealed by new classes of experimental observables accessible in synthetic quantum systems, which can, for instance, measure simultaneous site-resolved snapshots of all of the particles in a system. Specifically, we study the full counting statistics of spin transport, whose first moment is related to linear-response transport, but the higher moments go beyond. We present an analytic theory of the full counting statistics of spin transport in various integrable and nonintegrable anisotropic one-dimensional spin models, including the XXZ spin chain. We find that spin transport, while diffusive on average, is governed by a distinct non-Gaussian dynamical universality class in the models considered. We consider a setup in which the left and right half of the chain are initially created at different magnetization densities, and consider the probability distribution of the magnetization transferred between the two half-chains. We derive a closed-form expression for the probability distribution of the magnetization transfer, in terms of random walks on the half-line. We show that this distribution strongly violates the large-deviation form expected for diffusive chaotic systems, and explain the physical origin of this violation. Here, we discuss the crossovers that occur as the initial state is brought closer to global equilibrium. Our predictions can directly be tested in experiments using quantum gas microscopes or superconducting qubit arrays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Valence, charge transfer, and orbital-dependent correlation in bilayer nickelates Nd 3 Ni 2 O 7

We examine the bulk electronic structure of Nd 3 Ni 2 O 7 using Ni 2 p core-level hard x-ray photoemission spectroscopy combined with density functional theory + dynamical mean-field theory. Our results reveal a large deviation of the Ni 3 d occupation from the formal Ni 2.5 + valency, highlighting the importance of the charge transfer from oxygen ligands. We find that the dominant d 8 configuration is accompanied by nearly equal contributions from d 7 and d 9 states, exhibiting an unusual valence state among Ni-based oxides. Finally, we discuss the Ni d x 2 − y 2 and d z 2 orbital-dependent hybridization, correlation and local spin dynamics. Published by the American Physical Society 2025

Takegami, Daisuke (ORCID:0000000338321849)↗

Constraining the neutron-matter equation of state with gravitational waves

We demonstrate how observations of gravitational waves from binary neutron star (BNS) mergers over the next few years can be combined with insights from nuclear physics to obtain useful constraints on the equation of state (EoS) of dense matter. In particular, the neutron-matter EoS between 1 and 2 times the nuclear saturation density $n_0$ ≈ 0.16 fm –3 can be constrained to within 20%, given the simulated data from about 15 merger events. Using Fisher information methods, we combine observational constraints from simulated BNS merger events drawn from various population models with independent measurements of the neutron star radii expected from x-ray astronomy [the Neutron Star Interior Composition Explorer observations in particular] to directly constrain nuclear physics parameters. To parametrize the nuclear EoS, we use a different approach, expanding from pure nuclear matter rather than from symmetric nuclear matter to make use of recent quantum Monte Carlo calculations. This method eschews the need to invoke the so-called parabolic approximation to extrapolate from symmetric nuclear matter, allowing us to directly constrain the neutron-matter EoS. Using a principal component analysis, we identify the combination of parameters most tightly constrained by observational data. We discuss sensitivity to various effects such as different component masses through population-model sensitivity, phase transitions in the core EoS, and large deviations from the central parameter values.

79 ASTRONOMY AND ASTROPHYSICS↗

Quasiparton distributions in massive QED2: Toward quantum computation

We analyze the quasiparton distributions of the lightest 𝜂′ meson in massive two-dimensional quantum electrodynamics (QED2) by exact diagonalization. The Hamiltonian and boost operators are mapped onto spin qubits in a spatial lattice with open boundary conditions. The lowest excited state in the exact diagonalization is shown to interpolate continuously between an anomalous 𝜂′ state at strong coupling, and a nonanomalous heavy meson at weak coupling, with a cusp at the critical point. The boosted 𝜂′ state follows relativistic kinematics but with large deviations in the luminal limit. The spatial quasiparton distribution function and amplitude for the 𝜂′ state are computed numerically for increasing rapidity both at strong and weak coupling, and compared to the exact light front results. The numerical results from the boosted form of the spatial parton distributions, compare fairly with the inverse Fourier transformation of the luminal parton distributions, derived in the lowest Fock space approximation. Our analysis points out some of the limitations facing the current lattice program for the parton distributions.

Lattice field theory↗

Axial-vector form factors of the nucleon from lattice QCD

In this paper, we present results for the form factors of the isovector axial vector current in the nucleon state using large scale simulations of lattice QCD. The calculations were done using eight ensembles of gauge configurations generated by the MILC collaboration using the HISQ action with 2 + 1 + 1 dynamical flavors. These ensembles span three lattice spacings a ≈ 0.06 , 0.09, and 0.12 fm and light-quark masses corresponding to the pion masses M π ≈ 135, 225, and 310 MeV. High-statistics estimates allow us to quantify systematic uncertainties in the extraction of G A (Q 2 ) and the induced pseudoscalar form factor G P (Q 2 ) . We perform a simultaneous extrapolation in the lattice spacing, lattice volume and light-quark masses of the axial charge radius r A data to obtain physical estimates. Using the dipole ansatz to fit the Q 2 behavior we obtain r A | dipole = 0.49(3) fm , which corresponds to M A = 1.39(9) GeV , and is consistent with M A = 1.35(17) GeV obtained by the miniBooNE collaboration. The estimate obtained using the z -expansion is r A | z - expansion = 0.46(6) fm, and the combined result is r A | combined = 0.48(4) fm. Analysis of the induced pseudoscalar form factor G P (Q 2 ) yields low estimates for g* P and g π NN compared to their phenomenological values. To understand these, we analyze the partially conserved axial current (PCAC) relation by also calculating the pseudoscalar form factor. Lastly, we find that these low values are due to large deviations in the PCAC relation between the three form factors, and in the pion-pole dominance hypothesis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sampling rare fluctuations of discrete-time Markov chains

We describe a simple method that can be used to sample the rare fluctuations of discrete-time Markov chains. Here, we focus on the case of Markov chains with well-defined steady-state measures, and derive expressions for the large-deviation rate functions (and upper bounds on such functions) for dynamical quantities extensive in the length of the Markov chain. We illustrate the method using a series of simple examples, and use it to study the fluctuations of a lattice-based model of active matter that can undergo motility-induced phase separation.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermodynamic Control of Activity Patterns in Cytoskeletal Networks

Biological materials, such as the actin cytoskeleton, exhibit remarkable structural adaptability to various external stimuli by consuming different amounts of energy. In this Letter, we use methods from large deviation theory to identify a thermodynamic control principle for structural transitions in a model cytoskeletal network. Specifically, we demonstrate that biasing the dynamics with respect to the work done by nonequilibrium components effectively renormalizes the interaction strength between such components, which can eventually result in a morphological transition. Further, our work demonstrates how a thermodynamic quantity can be used to renormalize effective interactions, which in turn can tune structure in a predictable manner, suggesting a thermodynamic principle for the control of cytoskeletal structure and dynamics.

59 BASIC BIOLOGICAL SCIENCES↗

Electrical transport, magnetic, and thermodynamic properties of La-, Pr-, and Nd-doped BaSn O 3 - δ single crystals

Due to outstanding room temperature electron mobility, the wide-gap perovskite semiconductor BaSnO 3 is of high current interest. Although n doping with Sb and O vacancies has been reported, most work has focused solely on La doping. Here we report bulk single crystals of Ba 1–x R x SnO 3–δ with R = La,Pr, and Nd, as well as unintentionally doped BaSnO 3–δ , thus exploring new rare earth (magnetic) dopants in addition to O vacancy doping. Consistent with recent results on epitaxial films, O vacancies are shown capable of generating mid-10 19 cm –3 Hall electron densities, with single crystal mobilities ~100–150cm 2 V –1 s –1 . Despite apparent solubility limits below ~0.5at.%, Pr and Nd are also shown to be effective n dopants, yielding Hall electron densities >1 × 10 20 cm –3 , and ambient and low temperature mobilities up to 175 and 430 cm 2 V –1 s –1 , respectively. In contrast to the La-doped case, clear paramagnetism occurs with Pr and Nd doping, allowing for direct estimates of dopant concentrations for quantitative comparison with Hall densities. We show that dopant and Hall densities can be approximately reconciled, but only after accounting for O vacancy doping. Specific heat measurements were also performed, confirming the BaSnO 3 Debye temperature, and revealing electronic contributions roughly consistent with reported effective masses. Interestingly, and likely related to crystalline electric field effects, Pr-doped BaSnO 3 exhibits large deviations from simple Curie-Weiss susceptibility, and a pronounced Schottky anomaly, which we analyze in detail. Furthermore, these results provide significant insight into doping in BaSnO 3 , establishing new rare earth magnetic dopants, clarifying the role of O vacancies, and determining dopant concentrations and solubility limits.

36 MATERIALS SCIENCE↗

Resilience of the surface code to error bursts

Quantum error correction works effectively only if the error rate of gate operations is sufficiently low. However, some rare physical mechanisms can cause a temporary increase in the error rate that affects many qubits; examples include ionizing radiation in superconducting hardware and large deviations in the global control of atomic systems. We refer to such rare transient spikes in the gate error rate as error bursts. In this work, we investigate the resilience of the rotated surface code to generic error bursts. We assume that, after appropriate mitigation strategies, the spike in the error rate lasts for only a single syndrome-extraction cycle; we also assume that the enhanced error rate is uniform across the code block. Under these assumptions, and for a circuit-level depolarizing noise model, we perform Monte Carlo simulations to determine the regime in burst error rate and background error rate for which the memory time becomes arbitrarily long as the code block size grows. Our results indicate that suitable hardware mitigation methods combined with standard decoding methods may suffice to protect against transient error bursts in the rotated surface code.

Quantum error correction↗

Consistency and reproducibility in atomic layer deposition

Atomic layer deposition (ALD) is a thin film synthesis technique that can provide exquisite accuracy and precision in film thickness and composition even on complex, large area substrates. Based on self-limiting surface chemistry, ALD can be insensitive to process conditions and reactor designs, allowing an ALD process developed in one lab to be easily reproduced in other labs. In practice, however, ALD is sometimes difficult to reproduce or replicate, and the results can vary substantially between ALD reactors and between labs. This is exemplified by large deviations in reports on the growth of, e.g., Al2O3, FeOx, and TiO2 given the same precursors under similar conditions. Furthermore, the problem of irreproducibility seems to be growing as ALD is adopted by more researchers and integrated into new applications. In this article, the authors highlight some of the major sources of variations and errors and common misconceptions related to ALD. In particular, the authors focus on issues related to precursors, substrates, and deposition tools. The authors illustrate these problems through examples from the literature, and they present results from numerical simulations that describe how nonidealities would manifest in thickness profiles in a typical cross-flow reactor. They also describe how reproducibility in ALD is linked to consistent experimental practice and reporting between labs. The authors’ hope is that by educating newcomers to ALD and advocating for consistent reporting of deposition conditions, they can minimize irreproducibility and enable ALD practitioners to realize the full potential afforded by self-limiting surface chemistry.

36 MATERIALS SCIENCE↗

SU-E-J-77: Dose Tracking On An MR-Linac for Online QA and Plan Adaptation in Abdominal Organs

Recent developments made MRI-guided radiotherapy feasible. Simultaneously performed imaging during dose delivery reveals the influence of changes in anatomy not yet known at the planning stage. When targeting highly motile abdominal organs, respiratory gating is commonly employed in MRI and investigated in external beam radiotherapy to mitigate malicious motion effects. The purpose of the presented work is to investigate anatomy-adaptive dose reconstruction in the treatment of abdominalorgans using concurrent (duplex) gating of an integrated MRlinac modality.Using navigators, 3D-MR images were sampled during exhale phase, requiring 3s per axial volume (360×260×100mm{sup 3}, waterselective T1w-FFE). Deformation vector fields (DVF) were calculated for all imaging dynamics with respect to initial anatomy, yielding an estimation of anatomy changes over the time of a fraction. A pseudo-CT was generated from the outline of a reference MR image, assuming a water-filled body. Consecutively, a treatment was planned on a fictional kidney lesion and optimized simulating a 6MV linac in a 1.5T magnetic field. After delivery, using the DVF, the pseudo-CT was deformed and dose accumulated for every individual gating interval yielding the true accumulated dose on the dynamic anatomy during beam-on.Dose-volume parameters on the PTV show only moderate changes when incorporating motion, i.e. ΔD{sub 99} (GTV)=0.3Gy with D{sub 99} (GTV)=20Gy constraints. However, local differences in the PTV region showed underdosages as high as 2.7Gy and overdosages up to 1.4Gy as compared to the optimized dose on static anatomy.A dose reconstruction toolchain was successfully implemented and proved its potential in the duplex gated treatment of abdominal organs by means of an MR-linac modality. While primary dose constraints were not violated on the fictional test data, large deviations could be found locally, which are left unaccounted for in conventional treatments. Dose-tracking of both target structures and organs at risk using 3D MRI during treatment enables truly adaptive hypofractionated radiotherapy. This work was funded by the SoRTS consortium, which includes the industry partners Elekta, Philips and Technolution.

60 APPLIED LIFE SCIENCES↗

SU-F-T-464: Development of a Secondary Check Procedure to Evaluated Flatness and Symmetry Discrepancies Detected During Daily Morning QA

Purpose: A daily QA device is used to monitor output, flatness and symmetry constancy for all linac photon and electron energies. If large deviations from baseline in flatness or symmetry are reported it becomes necessary to crosscheck the measurements with a second device. Setting up another device such as Matrixx (IBA Dosimetry) can be time consuming, due to its warm-up time, and trained personnel may not be readily available to analyze the results. Furthermore, this discrepancy is frequently isolated to a single energy. Unaffected energies could still be used, avoiding further patient delays, if a method to gather data for offline analysis could be developed. We find that optically stimulated luminescent dosimeters (OSLDs) provide a quick, simple, and inexpensive solution to this important clinical problem. Methods: The exact geometry of the detectors on the daily tracker (Keithley Therapy Beam Evaluator) was reproduced by placing nanoDot OSLDs (Landauer) on a solid water phantom. A combination of bolus and solid water was placed on top to provide buildup and prevent air gaps. Standard daily measurements of output, flatness and symmetry were taken for 2 photon energies (6x,10x) and 5 electron energies (6e,9e,12e,15e,18e) using the tracker. These measurements were then repeated with the OSLD phantom. Results: The time it took to set up the OSLD phantom was comparable to that of the tracker. The inline and crossline OSLD phantom measurements of flatness and symmetry agreed with the tracker results to within 2%. Conclusion: OSLDs provide a good solution for a quick second check when questionable flatness and symmetry results are detected with the tracker during daily QA.

60 APPLIED LIFE SCIENCES↗

SU-F-T-480: Evaluation of the Role of Varian Machine Performance Check (MPC) in Our Daily QA Routine

Purpose: (A) To assess the role of Varian MPC in our daily QA routine, and (B) evaluate the accuracy and precision of MPC. Methods: The MPC was performed weekly, for five months, on a Varian TrueBeam for five photon (6x, 10x, 15x, 6xFFF, and 10xFFF) and electron (6e, 9e, 12e, 16e, and 20e) energies. Output results were compared to those determined with an ionization chamber (TN30001, PTW-Freiburg) in plastic and a daily check device (DQA3, Sun Nuclear). Consistency of the Mechanical measurements over five months was analyzed and compared to monthly IsoCal results. Results: The MPC randomly showed large deviations (3–7%) that disappeared upon reacquisition. The MPC output closely matched monthly ion chamber and DQA3 measurements. The maximum and mean absolute difference between monthly and MPC was 1.18% and 0.28±0.21% for all energies. The maximum and mean absolute difference between DQA3 and MPC was 3.26% and 0.85±0.61%. The results suggest the MPC is comparable to the DQA3 for measuring output. The DQA3 provides wedge output, flatness, symmetry, and energy constancy checks, which are missing from the current implementation of the MPC. However, the MPC provides additional mechanical tests, such as size of the radiation isocenter (0.33±0.02 mm) and its coincidence with MV and kV isocenters (0.17±0.05 and 0.21±0.03 mm). It also provides positional accuracy of individual jaws (maximum σ, 0.33mm), all the MLC leaves (0.08mm), gantry (0.05°) and collimator (0.13°) rotation angles, and couch positioning (0.11mm) accuracy. MPC mechanical tests could replace our current daily on-board imaging QA routine and provide some additional QA not currently performed. Conclusion: MPC has the potential to be a valuable tool that facilitates reliable daily QA including many mechanical tests that are not currently performed. This system can add to our daily QA, but further development would be needed to fully replace our current Daily QA device.

60 APPLIED LIFE SCIENCES↗

SU-G-201-17: Verification of Dose Distributions From High-Dose-Rate Brachytherapy Ir-192 Source Using a Multiple-Array-Diode-Detector (MapCheck2)

Purpose: To investigate quantitatively the accuracy of dose distributions for the Ir-192 high-dose-rate (HDR) brachytherapy source calculated by the Brachytherapy-Planning system (BPS) and measured using a multiple-array-diode-detector in a heterogeneous medium. Methods: A two-dimensional diode-array-detector system (MapCheck2) was scanned with a catheter and the CT-images were loaded into the Varian-Brachytherapy-Planning which uses TG-43-formalism for dose calculation. Treatment plans were calculated for different combinations of one dwell-position and varying irradiation times and different-dwell positions and fixed irradiation time with the source placed 12mm from the diode-array plane. The calculated dose distributions were compared to the measured doses with MapCheck2 delivered by an Ir-192-source from a Nucletron-Microselectron-V2-remote-after-loader. The linearity of MapCheck2 was tested for a range of dwell-times (2–600 seconds). The angular effect was tested with 30 seconds irradiation delivered to the central-diode and then moving the source away in increments of 10mm. Results: Large differences were found between calculated and measured dose distributions. These differences are mainly due to absence of heterogeneity in the dose calculation and diode-artifacts in the measurements. The dose differences between measured and calculated due to heterogeneity ranged from 5%–12% depending on the position of the source relative to the diodes in MapCheck2 and different heterogeneities in the beam path. The linearity test of the diode-detector showed 3.98%, 2.61%, and 2.27% over-response at short irradiation times of 2, 5, and 10 seconds, respectively, and within 2% for 20 to 600 seconds (p-value=0.05) which depends strongly on MapCheck2 noise. The angular dependency was more pronounced at acute angles ranging up to 34% at 5.7 degrees. Conclusion: Large deviations between measured and calculated dose distributions for HDR-brachytherapy with Ir-192 may be improved when considering medium heterogeneity and dose-artifact of the diodes. This study demonstrates that multiple-array-diode-detectors provide practical and accurate dosimeter to verify doses delivered from the brachytherapy Ir-192-source.

60 APPLIED LIFE SCIENCES↗

Variational Path Sampling of Rare Dynamical Events

This article reviews the concepts and methods of variational path sampling. These methods allow computational studies of rare events in systems driven arbitrarily far from equilibrium. Based upon a statistical mechanics of trajectory space and leveraging the theory of large deviations, they provide a perspective from which dynamical phenomena can be studied with the same types of ensemble reweighting ideas that have been used for static equilibrium properties. Applications to chemical, material, and biophysical systems are highlighted.

Singh, Aditya N↗

Isothermal Microcalorimetric Analysis of Li/CF x Battery Discharge

Lithium/carbon monofluoride (Li/CF x ) batteries generate substantial amounts of heat during discharge in part due to the large deviation of the loaded voltage from the measured and thermodynamically predicted open circuit voltage. Here, in this study, we further analyze this system by estimating the equilibrium voltage (V eq ) and its temperature dependence (dV eq /dT) over the entire discharge range. Based on these results, the ohmic and entropic heat contributions to the overall heat flow are calculated from experimental data. The ohmic heat flow is consistent with an electrochemical impedance spectroscopy model and electrode density measurements, indicating decreasing porosity of the electrode during discharge. Entropic heating increases during discharge as the cell reaction becomes increasingly entropically unfavorable. The total energy dissipated by the cell (electrical and thermal) remains similar over the entire discharge, evidence for a two-phase reaction with a constant, and rate-independent, ΔG rxn of about -465 kJ mol -1 . However, near the end of discharge (>90% DOD), ΔG rxn changes significantly indicating possible secondary reactions.

25 ENERGY STORAGE↗