Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscopy, Electron, Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Electron beam irradiation effects on bulk metals: a comparative study of polycrystalline versus single-crystalline structures

This study investigates the effects of electron beam (e-beam) irradiation on the mechanical and structural properties of eight bulk metallic samples, comprising both polycrystalline (PC) and single-crystalline (SC) forms of Ni, Cr, V, and Ti. These metals were evaluated as potential candidates for beam exit windows in high-power (MW-class) particle accelerators. The primary objective is to identify metals capable of withstanding the conditions of high-power/MW-class e-beam accelerators and serve effectively as exit windows. Selection criteria were based on each metal’s intrinsic properties, power dissipation capability, and irradiation-induced changes in mechanical behavior, including hardness, elastic modulus, and defect density. Comprehensive characterization was conducted using field-emission scanning electron microscopy (FESEM), atomic force microscopy (AFM), scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM–EDS), X-ray diffraction (XRD), high-resolution transmission electron microscopy (HRTEM), selected area electron diffraction (SAED), and nanoindentation, performed both before and after exposure to a ~¿66 kGy dose from a 10 MeV e-beam accelerator. Results revealed that e-beam irradiation induced hardening in PC Ni, whereas PC Ti, commonly used in beam exit windows, exhibited softening. The observed softening in PC Ti is attributed to grain coarsening, elongation, and the formation of twins and twin boundaries, in contrast to the smaller, compressed grains in the pristine (Pr) PC Ti samples, consistent with the Hall–Petch relationship. The stresses due to twinning are small and insignificant in influencing the overall hardening of the PC Ti irradiated sample when compared to the stresses due to the dislocation density. Conversely, SC Ti samples exhibited irradiation-induced hardening. The SC Ti irradiated samples developed additional irradiation-induced modifications in crystallographic texture of (100), (101), (110), (200), (112), (004), and (211) as evidenced from the XRD results, which could probably explain the hardening effect that is caused by irradiation.

36 MATERIALS SCIENCE↗

End-to-End Automated Segmentation Framework for Four-Dimensional Scanning Transmission Electron Microscopy Data

Four-dimensional scanning transmission electron microscopy (4D-STEM) is powerful for rapidly characterizing arrays of nanoparticles produced via high-throughput synthesis. However, such 4D-STEM datasets typically contain thousands of nanoparticles, each characterized by thousands of diffraction patterns spatially distributed across the nanoparticle, necessitating efficient and comprehensive analysis. We propose an end-to-end segmentation framework to automatically segment each nanoparticle into regions with distinct composition/orientation of crystal grains, using only the 4D-STEM data. Bragg disk information is extracted in a physics-informed manner from the diffraction patterns at each spatial location and combined with the real space coordinates to form feature vectors. These feature vectors are then used as inputs to a Gaussian mixture model (GMM) to segment the nanoparticle into distinct regions. We also develop two visualization tools based on the GMM outputs to infer the interface transition and the degree of superposition. Our framework comprehensively integrates machine learning tools and physics knowledge, and provides a basis for substantially compressing enormous 4D-STEM datasets, e.g., by replacing the full 4D-STEM dataset for each nanoparticle with only a single set of Bragg disk features for each distinct crystal grain identified in the nanoparticle. In this article, we demonstrate the power of our framework by presenting results for real, complex datasets.

47 OTHER INSTRUMENTATION↗

Results of the Aerosol Sampling Experiment on the International Space Station

The indoor air quality of the International Space Station (ISS), in terms of particulate matter, has been assessed through a sampling experiment that collected airborne debris for return to Earth. The Aerosol Sampling Experiment took place on ISS in December 2016 and January 2017, with sample return in February 2017. For redundancy, two different aerosol samplers collected particles in two size ranges spanning from 10 nm to hundreds of micrometers. Multiple analysis techniques have been used to characterize the particles, such as reflective light microscopy, manual scanning electron microscopy (SEM) analysis (secondary and backscattered imaging) with energy dispersive spectroscopy (EDS) x-ray analysis, computer controlled scanning electron microscopy (CCSEM) and Raman spectroscopy. Sampling took place in five locations on ISS, with the greatest deposition of particles in Node 3, followed by Node 1, the US Lab and Node 2. The PMM had very few airborne particles, as expected, owing to the lack of human presence. A large proportion of the sampled material consisted of fibers from clothing. Many particles had complex morphologies or contained multiple metals in a carbonaceous matrix. Metal particles were analyzed for each sampling location in terms of both weight and number percent, with 27 heavy metals detected. Fiberglass and TiO2 particles were present in every location. Quantitative analysis results are presented, and where possible, particle emission sources are identified with the intention to fuel discussions on mitigation.

Meyer, Marit E.↗

Raw electron microscopy images for "The Importance of Nano-edges in Atomic Stencilling and Chiroptically Active Assembly of Patchy Gold Tetrahedra"

This dataset contains the raw transmission electron microscopy (TEM) and scanning electron microscopy (SEM) images used in the main figures of the paper “The Importance of Nano-edges in Atomic Stencilling and Chiroptically Active Assembly of Patchy Gold Tetrahedra (2026).” All the images were acquired at the Materials Research Laboratory, University of Illinois at Urbana-Champaign, by Qian Chen group. 1. We provide five subfolders, each named according to the corresponding figure numbers in the paper. 2. All files in the subfolders for Figures 1–3 and 5 are named as "Panel [letter]_*", where [letter] (e.g., a, b, c) represents the raw images used for the corresponding panels. 3. All files in the subfolder for Figure 4 correspond to panel f and show the configurations of patchy tetrahedra synthesized at varying concentrations of iodide and 2-naphthalenethiol. They are named "Experiment_[number]", where [number] represents the corresponding data points in the phase diagram. 4. In TEM images, the bright and dark regions indicate the polymer patches and nanoparticle cores, respectively. 5. In SEM images, the bright and dark regions indicate the nanoparticle cores and polymer patches, respectively. 6. Abbreviations in file names: HAADF-STEM (high-angle annular dark-field scanning transmission electron microscopy), PINEM (photon-induced near-field electron microscopy), and RCP/LCP (left-/right-handed circularly polarized).

chirality↗

Biofilm formation and control in a simulated spacecraft water system - Two-year results

The ability of iodine to maintain microbial water quality in a simulated spacecraft water system is being studied. An iodine level of about 2.0 mg/L is maintained by passing ultrapure influent water through an iodinated ion exchange resin. Six liters are withdrawn daily and the chemical and microbial quality of the water is monitored regularly. Stainless steel coupons used to monitor biofilm formation are being analyzed by culture methods, epifluorescence microscopy, and scanning electron microscopy. Results from the first two years of operation show a single episode of high bacterial colony counts in the iodinated system. This growth was apparently controlled by replacing the iodinated ion exchange resin. Scanning electron microscopy indicates that the iodine has limited but not completely eliminated the formation of biofilm during the first two years of operation. Significant microbial contamination has been present continuously in a parallel noniodinated system since the third week of operation.

Schultz, John R.↗

High lung volume increases stress failure in pulmonary capillaries

We previously showed that when pulmonary capillaries in anesthetized rabbits are exposed to a transmural pressure (Ptm) of approximately 40 mmHg, stress failure of the walls occurs with disruption of the capillary endothelium, alveolar epithelium, or sometimes all layers. The present study was designed to test whether stress failure occurred more frequently at high than at low lung volumes for the same Ptm. Lungs of anesthetized rabbits were inflated to a transpulmonary pressure of 20 cmH2O, perfused with autologous blood at 32.5 or 2.5 cmH2O Ptm, and fixed by intravascular perfusion. Samples were examined by both transmission and scanning electron microscopy. The results were compared with those of a previous study in which the lung was inflated to a transpulmonary pressure of 5 cmH2O. There was a large increase in the frequency of stress failure of the capillary walls at the higher lung volume. For example, at 32.5 cmH2O Ptm, the number of endothelial breaks per millimeter cell lining was 7.1 +/- 2.2 at the high lung volume compared with 0.7 +/- 0.4 at the low lung volume. The corresponding values for epithelium were 8.5 +/- 1.6 and 0.9 +/- 0.6. Both differences were significant (P less than 0.05). At 52.5 cmH2O Ptm, the results for endothelium were 20.7 +/- 7.6 (high volume) and 7.1 +/- 2.1 (low volume), and the corresponding results for epithelium were 32.8 +/- 11.9 and 11.4 +/- 3.7. At 32.5 cmH2O Ptm, the thickness of the blood-gas barrier was greater at the higher lung volume, consistent with the development of more interstitial edema. Ballooning of the epithelium caused by accumulation of edema fluid between the epithelial cell and its basement membrane was seen at 32.5 and 52.5 cmH2O Ptm. At high lung volume, the breaks tended to be narrower and fewer were oriented perpendicular to the axis of the pulmonary capillaries than at low lung volumes. Transmission and scanning electron microscopy measurements agreed well. Our findings provide a physiological mechanism for other studies showing increased capillary permeability at high states of lung inflation.

Non-NASA Center↗

Ionic-Based Electrochemical Gas Sensors for Low-Cost, High-Sensitivity SO2 Detection

Sulfur dioxide (SO2) is a toxic gas associated with adverse health and environmental effects that necessitate reliable monitoring techniques. Here, we report the development of an all-solid-state electrochemical sensor utilizing a lithium borate (Li3BO3) solid electrolyte capable of subppm of SO2 detection. While subppm of SO2 sensing has been previously demonstrated in other solid-state electrolyte systems─such as stabilized zirconia, natrium super ionic conductors (NASICON) under mixed-potential conditions─here we establish Li3BO3 as an alternative solid electrolyte enabling equilibrium potentiometric sensing in an all-solid architecture. This sensor demonstrates a detection limit of at least 0.25 ppm, surpassing the human-olfactory threshold and meeting the rigorous requirements for industrial and personal monitoring applications. The sensing mechanism relies on the formation of Li2SO4 on the electrode surface, as evidenced by multimodal characterization techniques, including Raman spectroscopy, scanning electron microscopy (SEM), and scanning transmission electron microscopy (STEM). The strong linear correlation between the open-circuit potential (OCV) and the logarithm of SO2 concentration between 0.25 and 2 ppm indicates that the response is Nernstian in nature.

Lagunas, Francisco (ORCID:000000026377683X)↗

Revealing Phase Heterogeneity in Vertically Aligned Nanocomposites via Plan-View Electron Energy Loss Spectroscopy

Hydrogen utilization in clean energy technologies is challenged by limited storage and transport within materials, owing to the complex hydrogen kinetics at interfaces [1]. Understanding these interfacial mechanisms at the nanoscale is crucial for developing improved materials for hydrogen applications, particularly proton-conducting fuel cells (PCFCs). Vertically aligned nanocomposites (VANs) grown by pulsed laser deposition (PLD) offer a unique platform for investigating the interfacial effects on hydrogen transport due to their well-defined interfaces parallel to the direction of charge transport [2-4]. To investigate hydrogen transport, the two phases within the VANs were chosen as BaZr 0.9 Y 0.1 O 3-x (BZY), a known proton conductor, and Pr 0.1 Ce 0.9 O 2-x (PCO), a mixed ionic-electronic conductor [5]. This PCO-BZY VANs architecture allows the investigation of how the interface between a proton conductor and a mixed conductor influences hydrogen transport. However, because of the small size of hydrogen, it is difficult to discern the nature of its interactions with interfaces from bulk measurements at the macroscale, thus necessitating nanoscale measurements [6]. Electron energy loss spectroscopy (EELS) allows for nanometer-resolution probing of the local atomic structure and chemistry at the BZY/PCO interface. In this study, plan-view analysis of PCO-BZY VANs films was employed to characterize the structure and phase distribution of the VANs and investigate the interface between the nanostructures. The films were imaged using scanning electron microscopy (SEM) in the Hitachi S-4800 SEM, collecting secondary electron images using mixed upper and lower detectors. Then, plan-view transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) EELS were employed using a JEOL ARM300 microscope operated at 300kV with a Gatan K3 GIF Continuum detector to study the distribution of the BZY and PCO phases through the film. As a result, spectrum images were acquired at a dispersion of 0.18eV per channel and denoised afterward by principal component analysis (PCA) method.

Griffin, Elizabeth [Northwestern University, Evans↗

Microstructural Characterization of Felsite Fragments From the Apollo Next Generation Sample Analysis (ANGSA) Double Drive Tube 73001/73002

While the Moon’s surface is dominated by mafic igneous products formed through the crystallization of the lunar magma ocean, and the subsequent eruption of mare basalts – felsic magmatic fragments (variably referred to as felsites, granites, rhyolites or granophyres) have been identified from a number of Apollo samples (e.g. 12013[1], 14321[2], 15405[3] and 73215[4]). Magmatic edifices like the Gruithuisen Domes – silicic constructs sometimes found proximal to the basaltic mare provinces filling nearside basins, may represent a petrogenetic origin. However, this is, is complicated by the fact that they apparently predate mare volcanism (e.g. [5]). Additionally, crater-counting indicates that these silicic surface features also postdate radiogenic ages of Apollo felsites [6]. Various modes of felsic magmatism have been invoked to explain the presence of felsic lithologies on the Moon, including: 1) fractional crystallization and silicate liquid immiscibility; 2) partial melting of lunar crust through basaltic underplating; and 3) fractional crystallization of the mare parent magmas. Although these models are plausible, based on known Apollo samples and lunar meteorites, they are complicated by the lack of sample lithologies with intermediate composition between basaltic magmas and the felsic components, and the fact that partial melting of many crustal rock types on the Moon (e.g., anorthosite, troctolites) are unlikely to form granites. Along with other unique magmatic lithologies, new felsites have been identified within the < 1 mm size fractions of the ANGSA double drive core tube (73001/73002) from Apollo 17 station 3, sampling the light mantle landslide deposit from the South Massif [7]. These additional examples of lunar felsite will help us to better constrain the processes that lead to the formation of these evolved lithologies. To do this, we have employed a gambit of high-resolution scanning electron microscopy (SEM) and scanning transmission electron microscopy (TEM) analytical techniques, including electron backscatter diffraction (EBSD), cathodoluminescence and high-angle annular dark field (HAADF) imaging. These data provide unique insights into the felsite mineralogy and microstructures including the coexistence of quartz and tridymite in many of the fragments. In addition, these analyses provide petrological context and assist targeted in situ secondary ion mass spectrometry (SIMS) measurements of the U-Pb systematics of accessory minerals, and the volatile abundances and D/H ratios of apatite grains identified within the clasts.

lunar↗

Basalt Alteration in a CO 2 -SO 2 Atmosphere: Implications for Surface Processes on Venus

Venus’ surface and interior dynamics remain largely unconstrained, due in great part to the major obstacles to exploration imposed by its 470°C, 90 bar surface conditions and its thick, opaque atmosphere. Orbiter-based thermal emission data provide opportunities to characterize the surface composition of Venus. However, interpretations of such spectra depend on understanding interactions between the planet’s surface basaltic rocks and its caustic, sulfur dioxide (SO 2 )-bearing carbon dioxide (CO 2 ) atmosphere. Several studies, using remote sensing, thermodynamic modeling, and laboratory experiments, have placed constraints on basaltic alteration mineralogies and rates. Yet constraint with respect to SO 2 -mediated reactions with basalts of contrasting compositions remains incomplete. Here, we present new data from a series of gas-solid reaction experiments, in which samples of two basalt compositions were reacted in an SO 2 -bearing CO 2 atmosphere, at relevant Venus temperatures, pressure, and oxygen fugacity. We subjected reacted specimens to scanning electron microscopy (SEM) and scanning transmission electron microscopy (STEM) analyses using sample cross-sections produced with focused ion beam (FIB) milling. Surface alteration products were characterized, and their abundances estimated; subsurface cation concentrations were mapped to show depth of alteration. We demonstrate that the initial rate of reaction in our experiments is very rapid. Alkaline basalt samples are coated by (meta)thenardite (Na 2 SO 4 ) and amorphous calcium carbonate (CaCO 3 ) alteration products, and tholeiitic basalt samples are primarily covered by anhydrite (CaSO 4 ), Fe-oxide (Fe x O y : likely magnetite, Fe 3 O 4 ), and other minor phases.

Venus↗

A parametric study of single-wall carbon nanotube growth by laser ablation

Results of a parametric study of carbon nanotube production by the double-pulse laser oven process are presented. The effect of various operating parameters on the production of single-wall carbon nanotubes (SWCNTs) is estimated by characterizing the nanotube material using analytical techniques, including scanning electron microscopy, transmission electron microscopy, thermo gravimetric analysis and Raman spectroscopy. The study included changing the sequence of the laser pulses, laser energy, pulse separation, type of buffer gas used, operating pressure, flow rate, inner tube diameter, as well as its material, and oven temperature. It was found that the material quality and quantity improve with deviation from normal operation parameters such as laser energy density higher than 1.5 J/cm2, pressure lower than 67 kPa, and flow rates higher than 100 sccm. Use of helium produced mainly small diameter tubes and a lower yield. The diameter of SWCNTs decreases with decreasing oven temperature and lower flow rates.

Nanotubes, Carbon/chemistry↗

Compatibility of molten plutonium with wrought and additively manufactured metal crucibles

Understanding plutonium’s interaction with metals is crucial for optimizing pyrochemical operations, nuclear fuel containment, and various actinide processing techniques. Traditionally, tantalum crucibles are employed for plutonium processing due to their high durability, excellent temperature stability, and low solubility in plutonium. However, tantalum faces challenges such as plutonium wetting and diffusion, making surface coatings particularly important for crucibles in pyrochemical applications to enhance corrosion resistance against plutonium. Tantalum is also expensive and difficult to machine, prompting the need for advanced manufacturing techniques to address these challenges. Here, in this work, we investigate the interaction of Pu with tantalum and titanium crucibles fabricated using both traditional machining methods and laser powder bed fusion (LPBF) additive manufacturing (AM). LPBF-AM is an advanced technique that allows for the creation of complex geometries from traditionally difficult-to-machine metals by using a high-powered laser to build parts. Previous studies of conventional manufactured tantalum have utilized oxidation and carburization of the surface to mitigate plutonium wetting; however, no studies of surface modified LPBF-AM material have been undertaken. These studies are crucial, given the typical differences in the grain structure between conventional and LPBF-AM materials. All crucibles underwent differential scanning calorimetry to confirm the melting of plutonium. Subsequently, the crucibles were sectioned and mounted in epoxy for microstructural analysis using optical microscopy and scanning electron microscopy. This investigation, comparing the performance of wrought vs AM metal crucibles, provides a basis for future tooling applications in actinide processing techniques and can address the challenges associated with traditional machining, particularly in pyrochemical applications.

Actinides↗

Microstress contrast in scanning electron acoustic microscopy of ceramics

A mathematical model of image contrast in scanning electron acoustic microscopy (SEAM) due to the effect of residual stresses in materials is presented. It is found that in regions near the ends of the radial cracks induced by Vickers indentation the SEAM micrographs reveal a rather large variation of the acoustic output signal.

Cantrell, John H.↗

Tutorial on In Situ and Operando (Scanning) Transmission Electron Microscopy for Analysis of Nanoscale Structure–Property Relationships

In situ and operando (scanning) transmission electron microscopy [(S)TEM] is a powerful characterization technique that uses imaging, diffraction, and spectroscopy to gain nano-to-atomic scale insights into the structure–property relationships in materials. This technique is both customizable and complex because many factors impact the ability to collect structural, compositional, and bonding information from a sample during environmental exposure or under application of an external stimulus. In the past two decades, in situ and operando (S)TEM methods have diversified and grown to encompass additional capabilities, higher degrees of precision, dynamic tracking abilities, enhanced reproducibility, and improved analytical tools. Much of this growth has been shared through the community and within commercialized products that enable rapid adoption and training in this approach. This tutorial aims to serve as a guide for students, collaborators, and nonspecialists to learn the important factors that impact the success of in situ and operando (S)TEM experiments and assess the value of the results obtained. As this is not a step-by-step guide, readers are encouraged to seek out the many comprehensive resources available for gaining a deeper understanding of in situ and operando (S)TEM methods, property measurements, data acquisition, reproducibility, and data analytics.

(S)TEM↗

Growth of diamond by RF plasma-assisted chemical vapor deposition

A system has been designed and constructed to produce diamond particles by inductively coupled radio-frequency, plasma-assisted chemical vapor deposition. This is a low-pressure, low-temperature process used in an attempt to deposit diamond on substrates of glass, quartz, silicon, nickel, and boron nitride. Several deposition parameters have been varied including substrate temperature, gas concentration, gas pressure, total gas flow rate, RF input power, and deposition time. Analytical methods employed to determine composition and structure of the deposits include scanning electron microscopy, absorption spectroscopy, scanning Auger microprobe spectroscopy, and Raman spectroscopy. Analysis indicates that particles having a thin graphite surface, as well as diamond particles with no surface coatings, have been deposited. Deposits on quartz have exhibited optical bandgaps as high as 4.5 eV. Scanning electron microscopy analysis shows that particles are deposited on a pedestal which Auger spectroscopy indicates to be graphite. This is a phenomenon that has not been previously reported in the literature.

Meyer, Duane E.↗

The 4D Camera: An 87 kHz Direct Electron Detector for Scanning/Transmission Electron Microscopy

We describe the development, operation, and application of the 4D Camera—a 576 by 576 pixel active pixel sensor for scanning/transmission electron microscopy which operates at 87,000 Hz. The detector generates data at ~480 Gbit/s which is captured by dedicated receiver computers with a parallelized software infrastructure that has been implemented to process the resulting 10–700 Gigabyte-sized raw datasets. The back illuminated detector provides the ability to detect single electron events at accelerating voltages from 30 to 300 kV. Through electron counting, the resulting sparse data sets are reduced in size by 10--300× compared to the raw data, and open-source sparsity-based processing algorithms offer rapid data analysis. The high frame rate allows for large and complex scanning diffraction experiments to be accomplished with typical scanning transmission electron microscopy scanning parameters.

47 OTHER INSTRUMENTATION↗

Scanning electron acoustic microscopy of indentation-induced cracks and residual stresses in ceramics

The ability of scanning electron acoustic microscopy (SEAM) to characterize ceramic materials is assessed. SEAM images of Vickers indentations in SiC whisker-reinforced alumina clearly reveal not only the radial cracks, the length of which can be used to estimate the fracture toughness of the material, but also reveal strong contrast, interpreted as arising from the combined effects of lateral cracks and the residual stress field left in the SiC whisker-reinforced alumina by the indenter. The strong contrast is removed after the material is heat treated at 1000 C to relieve the residual stresses around the indentations. A comparison of these observations with SEAM and reflected polarized light observations of Vickers indentations in soda-lime glass both before and after heat treatment confirms the interpretation of the strong contrast.

Cantrell, John H.↗

Morphologic differentiation of colon carcinoma cell lines HT-29 and HT-29KM in rotating-wall vessels

A new low shear stress microcarrier culture system has been developed at NASA's Johnson Space Center that permits three-dimensional tissue culture. Two established human colon adenocarcinoma cell lines, HT-29, an undifferentiated, and HT-29KM, a stable, moderately differentiated subline of HT-29, were grown in new tissue culture bioreactors called Rotating-Wall Vessels (RWVs). RWVs are used in conjunction with multicellular cocultivation to develop a unique in vitro tissue modeling system. Cells were cultivated on Cytodex-3 microcarrier beads, with and without mixed normal human colonic fibroblasts, which served as the mesenchymal layer. Culture of the tumor lines in the absence of fibroblasts produced spheroidlike growth and minimal differentiation. In contrast, when tumor lines were co-cultivated with normal colonic fibroblasts, initial growth was confined to the fibroblast population until the microcarriers were covered. The tumor cells then commenced proliferation at an accelerated rate, organizing themselves into three-dimensional tissue masses that achieved 1.0- to 1.5-cm diameters. The masses displayed glandular structures, apical and internal glandular microvilli, tight intercellular junctions, desmosomes, cellular polarity, sinusoid development, internalized mucin, and structural organization akin to normal colon crypt development. Differentiated samples were subjected to transmission and scanning electron microscopy and histologic analysis, revealing embryoniclike mesenchymal cells lining the areas around the growth matrices. Necrosis was minimal throughout the tissue masses. These data suggest that the RWV affords a new model for investigation and isolation of growth, regulatory, and structural processes within neoplastic and normal tissue.

Colonic Neoplasms/pathology↗