Search NASA⌕ Search

SEARCH · Search NASA

Results for “NIF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Ultra-fast single-crystal CVD diamonds in the particle time-of-flight (PTOF) detector for low yield burn-history measurements on the NIF (invited)

The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond-based detector and is the only diagnostic for measuring nuclear bang times of low yield (<1013) shots on the National Ignition Facility. Recently, a comprehensive study of detector impulse responses revealed certain detectors with very fast and consistent impulse responses with a rise time of <50 ps, enabling low yield burn history measurements. At the current standoff of 50 cm, this measurement is possible with fast 14 MeV neutrons from deuterium–tritium (DT) fusion plasmas. PTOF-inferred DT burn width numbers compare well with widths inferred from the gamma reaction history diagnostic on mid-yield (1013–1015) shots, where both systems are capable of making this measurement. These new capabilities could be extended to 2.5 MeV deuterium–deuterium neutrons from D plasmas and to even lower yield by reducing the detector standoff distance to 10 cm; a design for this is also presented.

42 ENGINEERING↗

Resolving discrepancies in bang-time predictions for indirect-drive ICF experiments on the NIF: Insights from the Build-A-Hohlraum campaign

This study investigated discrepancies between measured and simulated x-ray drive in Indirect-Drive Inertial Confinement Fusion (ID-ICF) hohlraums at the National Ignition Facility. Despite advances in radiation-hydrodynamic simulations, a consistent “drive deficit” remains. Experimentally measured ID-ICF capsule bang-times are systematically 400–700 ps later than simulations predict. The Build-A-Hohlraum (BAH) campaign explored potential causes for this discrepancy by systematically varying hohlraum features, including laser entrance hole (LEH) windows, capsules, and gas fills. Overall, the agreement between simulated and experimental x-ray drive was found to be largely unaffected by these changes. The data allow us to exclude some hypotheses put forward to potentially explain the discrepancy. Errors in the local thermodynamic equilibrium (LTE) atomic modeling, errors in the modeling of LEH closure, and errors due to a lack of plasma species mix physics in simulations are shown to be inconsistent with our measurements. Instead, the data support the hypothesis that errors in NLTE emission modeling are a significant contributor to the discrepancy. X-ray emission in the 2–4 keV range is found to be approximately 30% lower than in simulations. This is accompanied by higher than predicted electron temperatures in the gold bubble region, pointing to errors in non-LTE modeling. Introducing an opacity multiplier of 0.87 on energy groups above 1.8 keV improves agreement with experimental data, reducing the bang-time discrepancy from 300 to 100 ps. These results underscore the need for refined NLTE opacity models to enhance the predictive power of hohlraum simulations.

Band emission↗

Nonlocal effects on thermal transport in hydrodynamic simulations of unmagnetized MagLIF-relevant gaspipes on NIF

We present simulations of heat flow relevant to gaspipe experiments on the National Ignition Facility to investigate kinetic effects on transport phenomena. D 2 and neopentane (C 5 H 12 ) filled targets are used to study the laser preheat stage of a MagLIF scheme where an axial magnetic field is sometimes applied to the target. Simulations were done with the radiation-MHD code HYDRA with a collision-dominated fluid model and the SNB nonlocal electron thermal conduction model. Using the SNB model to evolve the electron temperature increased the heat front propagation of neopentane gas targets compared to a local model by limiting radial heat flow. This increases electron temperature near the axis, which decreases laser absorption. We find that the effect of heat flow models on temperature profiles and laser propagation is modest. Beyond the SNB model, we utilize HYDRA to initialize plasma conditions for the Vlasov–Fokker–Planck K2 code. We run K2 until a quasi-steady state is reached and examine the impact of kinetic effects on heat transport. Although axial heat flow is well predicted by fluid models, the fluid model consistently overpredicts radial heat flow up to 150% in regions with the largest temperature gradient of D 2 filled gaspipes. On the other hand, the SNB nonlocal electron conduction model is found to be adequate for capturing kinetic heat flow in gaspipes.

Lau, Ryan Y. [Univ. of Colorado, Boulder, CO (Unit↗

Development and scaling of MeV x-ray radiography at NIF-ARC

We investigate the generation of MeV x-rays using the Advanced Radiography Capability laser system at the National Ignition Facility using 1, 10, and 38 ps pulse durations, with laser energies reaching up to 4 kJ and using compound parabolic concentrators. Hydrodynamic simulations using up-to-date measurements of the contrast of the ARC laser are conducted, allowing us to employ an electron scaling model that incorporates scale length and pulse duration, which aligns closely with the observed temperature distributions. Comparable x-ray sources, in terms of dose, are generated when using a 10 ps pulse duration with 2.4 kJ at ∼1.9 ± 0.4 × 10 18 W/cm 2 and when using a 38 ps pulse duration with 4 kJ at 9.9 ± 0.4 × 10 17 W/cm 2 , both achieving ∼16 rad in air at 1 m for x-ray energies > 0.5 MeV. Radiographs performed on the laser “line-of-sight” show significant improvements in image quality than radiographs performed at 65 degrees to the laser axis. We verify the radiography performance using Monte Carlo Simulations.

Physics - Plasma physics↗

Modeling thermal radiation waves in silica plasmas for the Mooncat NIF experiment

The Mooncat experiment on the National Ignition Facility uses a laser-driven hohlraum to create a thermal radiation wave in a titanium-doped silica plasma. The titanium dopant enables absorption spectroscopy measurements to infer the temperature of the wave as it propagates. This measurement can be used to constrain multi-physics simulation codes to better understand when simulations do not match an experiment. In this paper, we present radiation-hydrodynamics simulations of the thermal radiation wave in the first full-platform shots of the Mooncat experiment. We examine the important parameters of the simulation, focusing on the radiation temperature source, the material model of the silica plasma as it pertains to radiation transport, and lateral leakage through a beryllium tube enclosing the silica. We compare different simulation modeling strategies to an analytic model of diffusive radiation transport and find that the simulation agrees with the analytic model when it is sufficiently simplified. These simulations show how radiation energy couples to matter to develop a shock wave in a radiative heat wave, an important topic in astrophysics and nuclear fusion plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Machine Learning Algorithms for Automated NIF Capsule Mandrel Selection

Small shells, approximately 2 mm in diameter, made from Poly(α-methylstyrene) (PAMS) are used as mandrels in the production of glow discharge polymer capsules located at the center of inertial confinement fusion experiments. The visual inspection process of microscope images of these shell mandrels, including detection of micron-sized defects on the shell surface as well as the handling and sorting, is a very labor-intensive, repetitive, and highly subjective process that stands to benefit greatly from automation. As part of an effort to decrease the number of labor hours spent in capsule handling, inspection, and metrology, the development of robotic systems was presented in a paper by Carlson et al., “Automation in Target Fabrication” [Fusion Sci. Technol., Vol. 70, p. 274 (2016)]. The current work expands the automated image acquisition systems developed previously and adds the use of convolutional neural networks to select capsules best suited for use in the downstream production process. Through the use of these machine learning algorithms, the selection process becomes robust, repeatable, and operator independent. Finally, as an added benefit the system developed as part of this work is able to provide defect statistics on entire shell batches and feed this information upstream to the production team.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of VISAR Mirrors for NIF Targets

The velocity interferometer system for any reflector (VISAR) is a key diagnostic at the National Ignition Facility that is used for measuring propagation and velocities of shocks through a sample for several high energy density campaigns. To support simultaneous measurements with VISAR and other diagnostics, optical mirrors are used to divert the VISAR signal off axis from the primary diagnostic line of sight, which can then be used for other measurements. Here, in this study, we describe our work on investigating issues with these mirrors to support complex new target geometries and signal variance due to system aging and more demanding polling rates. This paper also describes the key mitigation efforts performed to improve both the flatness and reflectivity of these commonly used mirrors.

National Ignition Facility↗

3D simulations of inertial confinement fusion implosions part 1: inline modeling of polarized cross beam energy transfer and subsequent drive anomalies on OMEGA and NIF

Inertial confinement fusion experiments are sensitive to cross-beam energy transfer (CBET), a laser-plasma instability that redistributes laser energy in the coronal plasma through self-generated ion acoustic wave (IAW) gratings. The detailed CBET coupling depends on the polarization state of the crossing wavefields. CBET itself can also scramble the beam polarizations by inducing ellipticity through the IAW grating, and rotating the seed polarization toward that of the pump. We develop a ray-based model that describes the polarized CBET coupling and that is compatible with the framework of 3D inline radiative hydrodynamics simulations. The model is implemented in the ASTER/IFRIIT code and verified against an academic test case and an offline polarized CBET post-processor. It is then applied to the detailed configuration of the distributed polarization rotator system on OMEGA, where results highlight how polarized CBET induces significant low modes in the collisional absorption source term. Finally, the modeling is applied to a simple indirect-drive configuration, comparing CBET calculations with 96 unpolarized or polarized beams with 24 unpolarized quads. It is shown that these cases produce similar power amplification per cone of beams grouped with similar polar angles. However, the 96 beam geometry itself is found to reduce azimuthal variations in quad power after the interaction and favors beams with larger polar angles within the cones, an effect that is amplified by the polarized CBET. Application of the model to inline calculations of OMEGA implosions are presented in a companion paper.

3D inline modeling↗

Direct Experimental Proof of the Principal Role of Reduced High-Mode Hydrodynamic Mix in Recent Ignition Success on NIF

This Letter details the role of reduced hydrodynamic mix in achieving the first fusion plasma to satisfy the Lawson criterion for ignition. Using novel 3D measurements of the temperature and density of the burning deuterium-tritium plasma across a series of experiments, we demonstrate that hydrodynamic mixing from small-scale capsule defects was a key degradation mechanism inhibiting ignition. A series of five layered deuterium-tritium experiments using 1.9 MJ of laser energy demonstrates a 2 × reduction of the thermonuclear yield when a lower quality capsule, typical of preignition experiments, is used. Radiation hydrodynamic calculations consistent with the observed mix profile show that the mixed fuel’s reduced compression and increased radiative loss explain the yield reduction. Furthermore, a hydroscaling argument suggests that a ∼ 3 MJ laser would be needed to reach ignition with such a capsule, well beyond the current capabilities of high energy laser systems. As such, this Letter gives critical insight into the physics of mix in self-heated fusion plasmas and establishes a foundation to evaluate capsule quality needs of future inertial fusion designs that aim at ignition and high gain.

High-energy-density plasmas↗

A Genetic Study of Nif -Associated Genes in a Hyperthermophilic Methanogen

Methanocaldococcus has been considered a model genus, but genetic tools have not been forthcoming until recently. Here, we develop and illustrate the utility of positive selection with either of two selective agents (simvastatin and neomycin), negative selection, generation of markerless in-frame deletion mutations, and genetic complementation.

59 BASIC BIOLOGICAL SCIENCES↗

Postshot report for double shell 2-axis keyhole NIF experiment N210224-001 [Slides]

The goal of this experiment is to measure preheat and shock symmetry in a double shell capsule. The campaign objective is to assess preheat and shock symmetry in high-Z double shells, and the shot objective is to measure preheat motion to ~0.2 km/s and shock breakout symmetry to ~100 ps.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗