Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Subcritical Californium Source Drive Noise Analysis Measurements With Unreflected Uranium (93.15) Hydride

On July 6, 1989, subcritical californium source-driven noise analysis (CSDNA) measurements were performed with bare uranium hydride cylindrical assemblies at the Los Alamos National Laboratory Critical Experiments Facility in KIVA 1. Three configurations of ~7.5 cm radius-enriched (93.15 wt. % 235 U) uranium hydride with a density of ~10 g/cm 3 cylinders were assembled with uranium hydride heights of ~11, ~14, and ~16 cm. The uranium hydride (~2 and ~3 cm high) was in thin-welded stainless steel cans. The neutron multiplication factors obtained on-line from the measured ratios of spectral densities were 0.942 ± 0.002, 0.917 ± 0.003, and 0.867 ± 0.004 for uranium hydride heights of ~16, ~14, and ~11 cm., respectively. Neutron multiplication factors for these three configurations calculated by Los Alamos National Laboratory Monte Carlo methods were 0.952 ± 0.005, 0.922 ± 0.005, and 0.860 ± 0.005, all of which are in good agreement with the measurements. The break frequency noise analysis data could be fitted to obtain the prompt neutron decay constant at all subcritical states. Some data presented in this report are from notes that are not in the logbooks. A discussion of the two different point kinetics theories of the measurements that illustrated the deficiencies of the rigorous theory at low neutron multiplication factors (k eff < 0.80) is given in an Appendix. These measurements may be the only configuration of unreflected, highly enriched uranium hydride configuration assembled. The presence of hydrogen diluted the uranium density, decreasing the reactivity, but this is offset by slowing down the neutron energy to the energy ranges of higher-fission cross sections. Extrapolations to delayed critical indicate that adding one more 3 cm can and one more 2 cm can would result in the unreflected cylindrical system being slightly above critical with a critical mass of ~37 kg, which is considerably less than the critical mass of an unreflected and unmoderated highly enriched uranium metal sphere. An unreflected, highly enriched uranium hydride sphere would have a critical mass less than 37 kg.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic Designs of New First Target Beamline Magnets for the ORNL SNS Upgrade

The Spallation Neutron Source (SNS) at ORNL currently is being upgraded from 1.0 GeV to 1.3 GeV. Several water-cooled magnets should be upgraded to transport 30% of higher beam energy. New chicane, injection/extraction septum, and Lambertson magnets were designed. Designing the magnets was a challenging task because the new magnets required good combined integrated field quality and needed to occupy the old magnets space but with about 20% greater integrated magnetic field. Additional strong requirements applied to the magnets fringe field do not disturb the circulating beam. The special field profiles had to be provided in foil areas between magnets. The analysis described here was based on OPERA3D simulations. A special technique was used for analyzing the integrated field harmonics. Initially, the particle track was simulated, and integrated field components were calculated along this track for the reference radius, which were used for the harmonics analysis. In addition, 3D field maps were provided for beam optics simulations. The final beamline analysis confirmed good beam transmission and low losses.

3d field maps↗

Image fusion for neutron tomography of nuclear fuel

Image fusion, the process of combining different images together, can be useful to create a more complete picture. In this work, image fusion is applied to neutron tomography of nuclear fuel with the goal of enhancing the information obtained about the fuel. Different reconstruction methods, such as Feldkamp, Davis and Kress filtered back projection and Simultaneous Reconstruction Technique, were combined to enhance image quality. This methodology was shown to reduce noise and ring artifacts without sacrificing sharp edges, allowing for a more accurate representation of sample geometry. Technique enhancements and future applications for the neutron imaging community are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Response of CR-39 nuclear track detectors to protons with non-normal incidence

This paper presents data from experiments with protons at non-normal incidence to CR-39 nuclear track detectors, analyzing the properties of detection efficiency, proton track diameter, track contrast, and track eccentricity. Understanding the CR-39 response to protons incident at an angle is important for designing charged particle detectors for inertial confinement fusion (ICF) applications. This study considers protons with incident energies less than 3 MeV. In this regime, an incident angle of 10° has no effect on CR-39 detection efficiency, and >85% detection efficiency is preserved up through 25° in the range of 1.0 MeV–2.1 MeV. For ICF applications, incident angles above 30° are deemed impractical for detector design due to significant drops in proton detection at all energies. We observe significant reductions in detection efficiency compared to theoretical predictions, particularly at low energies where proton tracks are etched away. The proton track diameter measured by the scan system is observed to decrease with higher incident angles. The track diameters are analyzed with two fitting models, and it is shown that the diameter–energy relation can be fit with the existing models at angles up to 30° . The optical contrast of the tracks tends to increase with the angle, meaning that the tracks are fainter, and a larger increase is observed for higher energies. Eccentricity, a measure of how elongated proton tracks are, increases with the incident angle and drops after the critical angle. The lowest energy tracks remain nearly circular even at higher angles.

47 OTHER INSTRUMENTATION↗

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)↗

Neutron Detectors for Scattering Applications

The book covers, for the first time, the most common neutron detectors used in neutron scattering facilities and all of those in use at Oak Ridge National Lab. The first two chapters describe the facilities, instruments and the critical detector parameters needed by various instruments. The third chapter focuses on the key components of the 3He-based linear position sensitive detectors as well as on their electronics, which require particular attention to signal-processing and noise reduction. The fourth chapter is dedicated to the 3He alternatives where scintillators play a critical role. Finally, chapter 5 covers emerging neutron detection technologies including semiconductors, vacuum-based devices and their associated readouts, which will be required in the future for high rate and high-resolution neutron detectors.

Diawara, Yacouba↗

Photon temporal-mode readout for inference of neutron star merger remnant gravitational waves

Gravitational waves emitted after neutron star binary coalescences and the information they carry about dense matter are a high-priority target for next-generation detectors. Even though such detectors are expected to observe millions of signals, detectable postmerger emission will remain rare. Here, in this work, we explore postmerger detectability and inference through an alternative detector readout scheme for data dominated by quantum-noise, which is the case above 1 kHz; photon-counting. In such a readout, signals and noise become quantized into discrete distributions corresponding to the detection of single photons measured in a chosen basis of modes. Through simulated data, we demonstrate that photon counting can be efficient even for weak signals. We find ∼1 in 100 signals with a postmerger signal-to-noise ratio of 0.2 can result in a single photon and thus be detected. Furthermore, after 2 ×10 4 signals—equivalent to 10 −2 to 1.5 years of observation—photon counting results in a twofold improvement in the measurement of the radius of a 1.6⁢𝑀 ⊙ neutron star. Constraints can be further tightened if the detector classical noise is reduced. Photon counting offers a promising alternative to traditional homodyne readout techniques for extracting information from low signal-to-noise ratio postmerger signals.

gravitational wave detection↗

Elucidating proximity magnetism through polarized neutron reflectometry and machine learning

Polarized neutron reflectometry is a powerful technique to interrogate the structures of multilayered magnetic materials with depth sensitivity and nanometer resolution. However, reflectometry profiles often inhabit a complicated objective function landscape using traditional fitting methods, posing a significant challenge for parameter retrieval. In this work, we develop a data-driven framework to recover the sample parameters from polarized neutron reflectometry data with minimal user intervention. We train a variational autoencoder to map reflectometry profiles with moderate experimental noise to an interpretable, low-dimensional space from which sample parameters can be extracted with high resolution. We apply our method to recover the scattering length density profiles of the topological insulator–ferromagnetic insulator heterostructure Bi2Se3/EuS exhibiting proximity magnetism in good agreement with the results of conventional fitting. We further analyze a more challenging reflectometry profile of the topological insulator–antiferromagnet heterostructure (Bi,Sb)2Te3/Cr2O3 and identify possible interfacial proximity magnetism in this material. We anticipate that the framework developed here can be applied to resolve hidden interfacial phenomena in a broad range of layered systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical and systematic uncertainties in extracting the source properties of neutron star-black hole binaries with gravitational waves

Gravitational waves emitted by neutron star black hole mergers encode key properties of neutron stars - such as their size, maximum mass and spins - and black holes. However, the presence of matter and the high mass ratio makes generating long and accurate waveforms from these systems hard to do with numerical relativity, and not much is known about systematic uncertainties due to waveform modeling. In this work, we simulate gravitational waves from neutron star black hole mergers by hybridizing numerical relativity waveforms produced with the SpEC code with a recent numerical relativity surrogate NRHybSur3dq8Tidal. These signals are analyzed using a range of available waveform families, and statistical and systematic errors are reported. We find that at a network signal-to-noise ratio (SNR) of 30, statistical uncertainties are usually larger than systematic offsets, while at an SNR of 70 the two become comparable. The individual black hole and neutron star masses, as well as the mass ratios, are typically measured very precisely, though not always accurately at high SNR. At a SNR of 30 the neutron star tidal deformability can only be bound from above, while for louder sources it can be measured and constrained away from zero. All neutron stars in our simulations are non-spinning, but in no case we can constrain the neutron star spin to be smaller than ~0.4 (90% credible interval). Waveform families whose late inspiral has been tuned specifically for neutron star black hole signals typically yield the most accurate characterization of the source parameters. Their measurements are in tension with those obtained using waveform families tuned against binary neutron stars, even for mass ratios that could be relevant for both binary neutron stars and neutron star black holes mergers.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantification of neural networks uncertainties with applications to SAFARI-1 axial neutron flux profiles

Deep Neural Networks (DNNs) have been widely used as a data-driven modelling tool in nuclear engineering. However, as a Machine Learning model, Artificial Neural Network (ANN) predictions are subjected to uncertainties originating from the noise in training data, incomplete coverage of the domain, and imperfect neural network architectures. In this work, we target at quantifying the prediction/approximation uncertainties of ANNs using Monte Carlo Dropout (MCD), as well as Bayesian Neural Networks (BNNs) which are solved by variational inference. With a demonstration problem in which neural networks are used to predict the assembly axial neutron flux profiles, the results have shown that the three different neural network models (regular DNNs, DNNs solved with MCD and BNNs) can produce results that agree very well among each other and with the measurement data, on cycles that are not used in the training process. Besides the excellent generalization capability, the uncertainty bands produced by MCD and BNN agree very well, and in general, they can fully envelop the noisy measurement data points. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT’s Germanium Array

We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe an on-beam excess of 20.6$^{+7.1}_{−6.3}$ counts with a total exposure of 10.22 GWhkg, and we reject the no-CEvNS hypothesis with 3.9⁢𝜎 significance. The result agrees with the predicted standard model of particle physics signal rate within 2⁢𝜎.

Electroweak interaction↗

R-process-rich Stellar Streams in the Milky Way*

We present high-resolution Magellan/MIKE spectra of 22 bright (9 < V < 13.5) metal-poor stars (-3.18 < [Fe/H] < -1.37) in three different stellar streams, the Helmi debris stream, the Helmi trail stream, and the ω Centauri progenitor stream. We augment our Helmi debris sample with results for 10 stars by Roederer et al. for a total of 32 stars. Detailed chemical abundances of light elements as well as heavy neutron-capture elements have been determined for our 22 stars. All three streams contain carbon-enhanced stars. For 13 stars, neutron-capture element lines were detectable, and they all show signatures in agreement with the scaled solar r -process pattern, albeit with a large spread of -0.5 < [Eu/Fe] < +1.3. Eight of these stars show an additional small s -process contribution superposed onto their r -process pattern. This could be discerned because of the relatively high signal-to-noise ratio of the spectra given that the stars are close by in the halo. Our results suggest that the progenitors of these streams experienced one or more r -process events early on, such as a neutron star merger or another prolific r -process source. This widely enriched these host systems before their accretion by the Milky Way. The small s -process contribution suggests the presence of asymptotic giant branch stars and associated local (inhomogeneous) enrichment as part of the ongoing chemical evolution by low-mass stars. Stars in stellar streams may thus be a promising avenue for studying the detailed history of large dwarf galaxies and their role in halo assembly with easily accessible targets for high-quality spectra of many stars.

Astronomy & Astrophysics↗

Photon-to-Digital Converters for Neutron Imaging Instruments (Final Report)

Oak Ridge National Laboratory (ORNL) collaborated with the Université de Sherbrooke (UdeS) to design a modular and scalable tile of innovative digital photodetectors called Photon-to-Digital Converters (PDC) and the required subsystems to demonstrate the feasibility of large area single-photon detectors to support high-resolution, depth-of-interaction, fast neutron radiography based on scintillation detectors. The goal is to demonstrate the advantages of using PDC over conventional Silicon Photomultiplier (SiPM) for neutron imaging systems. The basic building blocks of analog SiPM and PDC are Single-Photon Avalanche Photodiodes (SPAD). The main difference between conventional SiPMs and PDCs, is in the fact that analog SiPMs sum the charge produced by individual SPAD passively, while in PDCs each SPAD is read out individually by an active electronic circuit. Hence, PDCs provide a direct photon-to-bit conversion where a logic “1” means that there was a detection in a given SPAD. Conversely, an analog SiPM requires a sophisticated preamplifier (current amplifiers or transimpedance amplifier) followed by a shaping amplifier and an analog-to-digital converter. Moreover, since the charge from each SPAD varies slightly, the passive sum of the analog SiPM will have signal fluctuations for the same amount of photon detected. This is one of many issues that is completely eliminated by individual one-to-one SPAD read out in PDCs. The large area required for scintillator readouts for neutron imaging is such that the output capacitance of a large area of SiPM arrays is very high. This creates a burden on the signal-to-noise optimization with respect to the power budget. For PDC, the power consumption is dictated by rate of the incident photon flux, or in photon-starved environments, the dark noise rate of the SPAD array. In other words, the power consumption in the absence of events is extremely low. Hence, the power consumption of a PDC read out system is much lower than its analog counterpart. Further, the large SiPM capacitance may introduce signal distortions on the scintillator fast rise or decay time with undesired effects on timing and pulse shape discrimination. The problem is absent in PDCs, as their readout is independent on device capacitance. UdeS is the world leader in 3D vertical integration of frontside illuminated SPAD arrays over CMOS readouts. These capabilities allow future production of “3D PDC” with maximum photosensitive fill factor and electronic functionalities tailored to the application. UdeS' vast knowledge of SPADs and CMOS design made the team an ideal collaborator in the development of large area high-resolution fast neutron radiography.

42 ENGINEERING↗

Integrated Circuit Design for Radiation-Hardened Charge-Sensitive Amplifier Survived up to 2 Mrad

According to the continuous development of metal-oxide semiconductor (MOS) fabrication technology, transistors have naturally become more radiation-tolerant through steadily decreasing gate-oxide thickness, increasing the tunneling probability between gate-oxide and channel. Unfortunately, despite this radiation-hardened property of developed transistors, the field of nuclear power plants (NPPs) requires even higher radiation hardness levels. Particularly, total ionizing dose (TID) of approximately 1 Mrad could be required for readout circuitry under severe accident conditions with 100 Mrad around a reactor in-core required. In harsh radiating environments such as NPPs, sensors such as micro-pocket-fission detectors (MPFD) would be a promising technology to be operated for detecting neutrons in reactor cores. For those sensors, readout circuits should be fundamentally placed close to sensing devices for minimizing signal interferences and white noise. Therefore, radiation hardening ability is necessary for the circuits under high radiation environments. This paper presents various integrated circuit designs for a radiation hardened charge-sensitive amplifier (CSA) by using SiGe 130 nm and Si 180 nm fabrication processes with different channel widths and transistor types of complementary metal-oxide-semiconductor (CMOS) and bipolar CMOS (BiCMOS). These circuits were tested under γ–ray environment with Cobalt-60 of high level activity: 490 kCi. The experiment results indicate amplitude degradation of 2.85%–34.3%, fall time increase of 201–1730 ns, as well as a signal-to-noise ratio (SNR) of 0.07–11.6 dB decrease with irradiation dose increase. These results can provide design guidelines for radiation hardening operational amplifiers in terms of transistor sizes and structures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Implementation of Johnson Noise Thermometry into Radiation Hardened Electronics

The random motion of charge carriers in an electrical conductor is a function of its temperature. This phenomenon generates an electrical signal, referred to as Johnson noise, that is present in all analog signals. Conversely, the temperature dependence of the Johnson noise spectrum also enables a direct measurement of absolute temperature, which can provide a secondary measurement of temperature when quantified using sensors such as resistive temperature devices (RTDs) in a process called Johnson noise thermometry (JNT). For nuclear environments, this is of particular interest in correcting for RTDs signal drift caused by accumulation, transmutation, and displacement damage caused by neutron and gamma irradiation.

42 ENGINEERING↗

Alternative analysis of the MINERVE ZPR oscillation experiments

Delayed neutrons are of fundamental importance in the field of nuclear reactor dynamics and control. However, the precursor yield fraction for a given nuclear reactor are dependent on the properties of the reactor. Thus, in-pile experiments, such as oscillation experiments are conducted in order to measure those values. In this work, an alternative analysis of the piston oscillation experiments that have been conducted in the MINERVE reactor in 2013 is performed. A new method which evolves effective terms that cancel out undesired drifts of the flux during the experiments is presented. The evaluation of the uncertainty on the values of the response function is also presented. Moreover, the effective delayed neutron fraction β{sub eff} is evaluated and is compared to results in previous works. As the analysis has led to an estimation of β{sub eff} with a large uncertainty, it has been deduced that the oscillation experiments that have been conducted in MINERVE are not a reliable method of experimentation to determine the value of β{sub eff} in the reactor and that the noise experiments are better suited for that purpose.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reconstruction of concrete microstructure using complementarity of X-ray and neutron tomography

The concrete microstructure was successfully reconstructed using the complementarity of X-ray and neutron computed tomography (CT). Neither tomogram alone was found to be suitable to properly describe the microstructure of concrete under this study. However, by merging the information revealed by the two modalities, and using image segmentation, noise reduction, and image registration techniques we reconstruct the concrete microstructure. Void, aggregate, and cement paste phases are successfully captured down to the images' spatial resolution, even though the aggregate consists of multiple minerals. The coarse-aggregate volume fraction of the reconstructed microstructure was similar to that of the mixing proportions. Furthermore, image-based finite element analysis is performed to demonstrate the effects of microstructure on stress concentration and strain localization.

36 MATERIALS SCIENCE↗

A machine learning decision criterion for reducing scan time for hyperspectral neutron computed tomography systems

We present the first machine learning-based autonomous hyperspectral neutron computed tomography experiment performed at the Spallation Neutron Source. Hyperspectral neutron computed tomography allows the characterization of samples by enabling the reconstruction of crystallographic information and elemental/isotopic composition of objects relevant to materials science. High quality reconstructions using traditional algorithms such as the filtered back projection require a high signal-to-noise ratio across a wide wavelength range combined with a large number of projections. This results in scan times of several days to acquire hundreds of hyperspectral projections, during which end users have minimal feedback. To address these challenges, a golden ratio scanning protocol combined with model-based image reconstruction algorithms have been proposed. This novel approach enables high quality real-time reconstructions from streaming experimental data, thus providing feedback to users, while requiring fewer yet a fixed number of projections compared to the filtered back projection method. In this paper, we propose a novel machine learning criterion that can terminate a streaming neutron tomography scan once sufficient information is obtained based on the current set of measurements. Our decision criterion uses a quality score which combines a reference-free image quality metric computed using a pre-trained deep neural network with a metric that measures differences between consecutive reconstructions. The results show that our method can reduce the measurement time by approximately a factor of five compared to a baseline method based on filtered back projection for the samples we studied while automatically terminating the scans.