Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHOTOCONDUCTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Generation-recombination noise in extrinsic photoconductive detectors

A theory of generation-recombination noise is presented and applied to the analysis of the performance limitations of extrinsic photoconductive detectors. The theory takes account both of the photoinduced generation of carriers and of thermal generation that is due to the finite temperature of the detector. Explicit formulas are derived that relate the detector response time, responsivity, and noise equivalent power to the material properties of the photoconductor (such as the presence of compensating impurities) and to the detector's operating conditions, such as its temperature and the presence of background radiation. The detector's performance is shown to degrade at high background levels because of saturation effects.

Brukilacchio, T. J.↗

Performance of charge-injection-device infrared detector arrays at low and moderate backgrounds

Three 2 x 64 element charge injection device infrared detector arrays were tested at low and moderate background to evaluate their usefulness for space based astronomical observations. Testing was conducted both in the laboratory and in ground based telescope observations. The devices showed an average readout noise level below 200 equivalent electrons, a peak responsivity of 4 A/W, and a noise equivalent power of 3x10 sq root of W/Hz. Array well capacity was measured to be significantly smaller than predicted. The measured sensitivity, which compares well with that of nonintegrating discrete extrinsic silicon photoconductors, shows these arrays to be useful for certain astronomical observations. However, the measured readout efficiency and frequency response represent serious limitations in low background applications.

Mckelvey, M. E.↗

An FIR cooled grating spectrometer for the Kuiper Airborne Observatory

The design and performance of a liquid-He-cooled spectrometer being developed for the Kuiper Airborne Observatory (KAO) to study FIR lines originating in the interstellar medium are discussed. Currently, the spectrometer contains six Ge:Ga photoconductor detectors mounted in integrating cavities and cooled to about 3 K; the collimator focal plane has space for 39 such detectors. The instrument achieves a maximum resolving power of 6000 by means of a 45-cm long echelle grating and is optically capable of operating in the spectral range 25-300 microns. A laboratory spectrum of water vapor, an atmospheric water absorption feature measured from the KAO with Mars as a source, and the forbidden O(2+) emission from W51-IRS1 are shown.

Erickson, E. F.↗

Two-dimensional infrared detector arrays

An introduction to overall IR array concepts and particular array designs is presented, and examples of laboratory and observational data obtained with IR arrays are given. Hybrid array designs, extrinsic silicon accumulation-mode charge injection devices, and switched-FET or switched-sample photoconductor techniques are summarized. Three recent astronomical observation projects which used IR arrays are examined.

Mccreight, C. R.↗

Charge-injection-device 2 x 64 element infrared array performance

Three 2 x 64 element Si:Bi accumulation-mode charge-injection-device (CID) arrays were tested at low and moderate background to evaluate their usefulness for space-based astronomical observations. Testing was conducted both in the laboratory and in ground-based telescope IR observations. The devices showed an average readout noise level below 200 equivalent electrons, a peak responsivity of 4 A/W, and a noise equivalent power of 3 x 10 to the -17th W/sq rt Hz. This sensitivity compares well with that of nonintegrating discrete extrinsic silicon photoconductors. The array well capacity was significantly smaller than predicted. The measured sensitivity makes extrinsic silicon CID arrays useful for certain astronomical applications. However, their readout efficiency and frequency response represent serious limitations in low-background applications.

Mckelvey, M. E.↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

Spacecraft technology requirements for future NASA missions

Missions selected by NASA as representative of the most critical technology issues are described and the key technology requirements are discussed. The following are considered: (1) the Large Deployable Reflector (LDR), (2) the Sample Return Missions (SRM), (3) the Earth Observing System (EOS), and (4) the Geostationary Communications Platform (GCP). The LDR, designed for infrared and submillimeter astronomical measurements, will contain the following components for its instruments: indium antimonide charge-coupled arrays, extrinsic photodetector arrays, and heterodyne photoconductors. New technology developed for SRM includes an X-band transponder, a fiber-optic rotation sensor, and long-life batteries. The EOS will consist of instruments designed to measure the earth's atmosphere, interior, and surface, as well as an information system to support scientific research. Inherent in the platform of the GCP is the ability to effectively utilize both the geostationary arc and the electromagnetic spectrum; the GCP can also reduce overall satellite communications system costs.

Hudson, W. R.↗

A study of Si:In hybrid surface channel IRCCD devices

Hybrid silicon Infrared Charge Coupled Devices (IRCCDs) are evaluated for use as viable astronomical detectors. A Si:In photoconductor array which is bump-bonded to a silicon multiplexer is described. A summary of the device parameters is given.

Tollestrup, E.↗

Evaluation of a Si:Ga direct readout array

Preliminary results from the Hughes 58 x 62 gallium-doped silicon infrared array are presented. The device functioned predictably and repeatedly at the low temperatures for the Space Infrared Telescope Facility (SIRTF). Power dissipation was reduced to acceptable levels while still maintaining the device speed. The infrared response was excellent and the degree of anomalous effects was compatible to conventional photoconductors.

Lamb, G. M.↗

Semiconductor superlattice photodetectors

Technical progress made in the study of superlattice photoconductors is summarized and papers submitted for publication are listed. Since the quantum-well regions may contain several subbands, each of which may be occupied by electrons depending on the doping concentrations, it is important to include the multi-subbands in calculating the impact ionization rate. The electrons occupying the higher subbands require a smaller amount of energy to get out of the quantum well; thus, those higher level subband electrons contribute significantly to the impact ionization rate. The results of the subbands have been calculated. Results concerning the nonparabolicity effect of the band structure, the effect of the quantum-well size, and the effect of the band-edge discontinuity and doping are also summarized.

Chuang, S. L.↗

Balloon-borne cryogenic spectrometer for measurement of lower stratospheric trace constituents

A liquid-nitrogen cooled, multidetector Fourier transform spectrometer has been constructed to measure minor stratospheric constituents via high resolution, earth-limb emission spectroscopy from a balloon-borne platform. Cryogenic cooling, combined with the use of extrinsic silicon photoconductor detectors cooled to liquid-helium temperature, allows the detection of weak emission features of gaseous species. The spectrometer has two basic scan modes: the first mode records the continuous spectrum from 650-2100/cm with 0.2/cm resolution; the second simultaneously records four preselected narrow intervals (about 175/cm bandpass each) with 0.02/cm resolution, unapodized. Filtering of the interferogram signal is done by real-time, digital signal processing. The most important feature of this flat mirror Michelson system, with respect to remote balloon-borne operation, is the dynamic alignment system which maintains the relative parallelism of the two flat reflectors of the interferometer. Species identified to date in data obtained during a Nov. 6, 1984, flight include: CO2, O3, H2O, CH4, HNO3, N2O, NO2, NO, CCl3F (Freon-11) and CF2Cl2 (Freon-12).

Brasunas, J. C.↗

30-micron heterodyne receiver

Advantages and constraints of remote measurements using heterodyne spectroscopy near 30 microns are discussed. The state of the art of wideband HgCdTe photomixers and PbSnSe diode-laser local oscillators being developed for FIR heterodyne receivers is described. The first compact 30-micron heterodyne radiometer was built, and initial results at 28-microns show about 2-percent mixer efficiency for a 500-MHz-bandwidth receiver. Factors limiting receiver performance are discussed, along with the projected sensitivity of new interdigitated-electrode HgCdTe photoconductor mixers being developed for operation up to 200 microns.

Kostiuk, Theodor↗

Determination of rock type on Mercury and the moon through remote sensing in the thermal infrared

Thermal infrared emission spectra of the moon and Mercury have been obtained using the Si:As photoconductor and circular variable filter at the NASA Infrared Telescope Facility on Mauna Kea, Hawaii. Lunar spectra from 7.2 to 12.2 microns for two different locations in the south polar highlands have Christiansen frequency peaks at 8.1 microns and 7.9 microns, respectively. This indicates different compositions at the two locations; mafic in the first case, more felsic in the second. Emission spectra from Mercury are not as spatially localized,; however, the longitude of maximum contribution to the spectrum can be calculated from thermal models of the earth-facing disk. Results for areas centered at two longitudes have been obtained. Two locations in the intercrater plains were observed. At 40-deg longitude (very near the crater Homer), a peak at 7.9 microns indicates mafic igneous rock type. Spectra emanating from 46-deg longitude have peaks at 7.8 microns, indicating a region borderline between mafic and intermediate composition.

Tyler, Ann L.↗

An FTIR spectrometer for remote measurements of atmospheric composition

The JPL IV interferometer, and infrared Michelson interferometer, was built specifically for recording high resolution solar absorption spectra from remote ground-based sites, aircraft and from stratospheric balloons. The instrument is double-passed, with one fixed and one moving corner reflector, allowing up to 200-cm of optical path difference (corresponding to an unapodised spectral resolution of 0.003/cm). The carriage which holds the moving reflector is driven by a flexible nut riding on a lead screw. This arrangement, together with the double-passed optical scheme, makes the instrument resistant to the effects of mechanical distortion and shock. The spectral range of the instrument is covered by two liquid nitrogen-cooled detectors: an InSb photodiode is used for the shorter wavelengths (1.85 to 5.5 microns, 1,800 to 5,500/cm) and a HgCdTe photoconductor for the range (5.5 to 15 microns, 650 to 1,800/cm). For a single spectrum of 0.01/cm resolution, which requires a scan time of 105 seconds, the signal/noise ratio is typically 800:1 over the entire wavelength range.

Farmer, C. B.↗

Ga:Ge array development

Work at the University of Arizona and at Lawrence Berkeley Laboratory on the development of a far infrared array camera for the Multiband Imaging Photometer on the Space Infrared Telescope Facility (SIRTF) is discussed. The camera design uses stacked linear arrays of Ge:Ga photoconductors to make a full two-dimensional array. Initial results from a 1 x 16 array using a thermally isolated J-FET readout are presented. Dark currents below 300 electrons s(exp -1) and readout noises of 60 electrons were attained. Operation of these types of detectors in an ionizing radiation environment are discussed. Results of radiation testing using both low energy gamma rays and protons are given. Work on advanced C-MOS cascode readouts that promise lower temperature operation and higher levels of performance than the current J-FET based devices is described.

Young, Erick T.↗

Initial astronomical results with a new 5-14 micron Si:Ga 58x62 DRO array camera

A new array camera system was developed using a 58 x 62 pixel Si:Ga (gallium doped silicon) DRO (direct readout) photoconductor array detector manufactured by Hughes/Santa Barbara Research Center (SBRC). The camera system is a broad band photometer designed for 5 to 14 micron imaging with large ground-based optical telescopes. In a typical application a 10 micron photon flux of about 10(exp 9) photons sec(exp -1) m(exp -2) microns(exp -1) arcsec(exp -2) is incident in the telescope focal plane, while the detector well capacity of these arrays is 10(exp 5) to 10 (exp 6) electrons. However, when the real efficiencies and operating conditions are accounted for, the 2-channel 3596 pixel array operates with about 1/2 full wells at 10 micron and 10% bandwidth with high duty cycle and no real experimental compromises.

Gezari, Dan↗

Status of the isophot detector development

ISOPHOT is one of the four focal plane experiments of the European Space Agency's Infrared Space Observatory (ISO). Scheduled for a 1993 launch, it will operate extrinsic silicon and germanium photoconductors at low temperature and low background during the longer than 18 month mission. These detectors cover the wavelength range from 2.5 to 200 microns and are used as single elements and in arrays. A cryogenic preamplifier was developed to read out a total number of 223 detector pixels.

Wolf, J.↗

HgCdTe for NASA EOS missions and detector uniformity benchmarks

Important NASA Earth Observing System (EOS) missions, Atmospheric Infrared Sounder (AIRS) and Moderate Resolution Imaging Spectrometer (MODIS-N), which require detector spectral response in the range of 14 to 17 microns at medium background flux levels and operation in the range of temperatures between 65 to 95 K, will be flown beginning in the next few years. Currently, a prime candidate detector technology for these missions is trapping-mode photoconductive HgCdTe devices. These devices can be tailored to the exact cutoff wavelengths required by those missions, and thus offer the performance advantages of an intrinsic detector which is ideally matched to the mission wavelength. Under the long wavelength-background-temperature conditions of these EOS missions, any detector will at best be thermal generation-recombination noise limited. Photoconductive devices are generally preferred under these circumstances, since at elevated temperatures their performance degrades with n(sub i) while for photovoltaic detectors performance degrades as n sub i(exp 2) n sub i is the intrinsic carrier concentration which is a function of alloy composition and temperature, but not doping. Very high performance trapping-mode photoconductive HgCdTe detectors have been developed which can be reproducibly fabricated. Detectivity (D asterisk) at 80K and 16 micron cutoff wavelength in excess of 10(exp 11) Jones has been measured for these devices. Power dissipation is at least two orders of magnitude less than conventional HgCdTe photoconductors - on the order of 0.12 W/cm(exp 2) compared with 12 W/cm(exp 2). EOS missions define thermal noise limited conditions for the long wavelength operating bands. Trapping-mode photoconductive HgCdTe detectors are linear under such conditions and responsivity is independent of background flux. At lower temperatures or high flux conditions in which background flux limits detector performance, trapping-mode detectors have a responsivity which varies with background flux. Internal calibration must be provided for radiometric measurements under the latter conditions (not an EOS mission concern). Liquid phase epitaxy is used to grow these HgCdTe device structures. This technique has been shown to give control of the cutoff wavelength on the order of 16 plus or minus 1 micron or less, both from run to run and across wafer dimensions of several centimeters on a side.

Norton, Paul R.↗