Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

TOFHunter—unlocking rapid untargeted screening of inductively coupled plasma–time-of-flight–mass spectrometry data

This study provides an overview of a newly developed open source program written in Python, TOFHunter, which permits the rapid and untargeted screening of inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) datasets. ICP-TOF-MS is an analytical tool capable of providing quasi simultaneous detection of all nuclides from Li to Pu. This capability has triggered an increase in studies investigating single-particle analysis in which the TOF-MS provides correlated elemental/isotopic signatures on a particle basis in time. Similarly, laser ablation mapping has seen rapid growth owing to ICP-TOF-MS's capacity to handle fast washout times (<10 ms) while providing a broad nuclide coverage. The caveat to this broad mass coverage and high time resolution comes in the form of large, overwhelming datasets. With datasets typically on the scale of gigabytes, it is easy for a user to only focus on very targeted analytes; however, this focus diminishes the opportunity offered by the TOF-MS detector. TOFHunter applies chemometric methods, principal component analysis (PCA), and interesting features finder (IFF) on ICP-TOF-MS data, allowing for investigation of correlations, major and minor variance sources, and sample screening. The unique spectra identified by the (IFF) are used to generate a list of mass peaks, which are then matched with both nuclides and potential interferences before being exported for the user to investigate. Several case studies are discussed herein, demonstrating TOFHunter's ability to screen aqueous injections, single-particle/single-cell analysis, and probe laser ablation mapping files for unique regions of interest.

47 OTHER INSTRUMENTATION↗

Evaluation of methods for characterizing the fine particulate matter emissions from aircraft and other diffusion flame combustion aerosol sources

The U. S. Environmental Protection Agency in collaboration with the U. S. Air Force Arnold Engineering Development Complex conducted the VAriable Response In Aircraft nvPM Testing (VARIAnT) 3 and 4 test campaigns to compare nvPM emissions measurements from a variety of diffusion flame combustion aerosol sources (DFCASs), including a Cummins diesel engine, a diesel powered generator, two gas turbine start carts, a J85-GE-5 turbojet engine burning multiple fuels, and a Mini-CAST soot generator. The VARIAnT research program has conducted four test campaigns to date with the VARIAnT 3 and 4 test campaigns focusing on BC mass instrument performance, use of gas turbine engine sources for BC mass instrument calibration, and the characterization of the aerosols produced from the combustion sources. Results from both campaigns revealed agreement of about 20% between the AVL Micro-Soot Sensor, the Cavity Attenuated Phase Shift (CAPS PMSSA) monitor and the thermal-optical reference method for elemental carbon (EC), independent of the calibration source used. For the Artium LII-300, the measured mass concentrations in VARIAnT3 fall within 18% and in VARIAnT4 fall within 32% of the reference EC mass concentration when calibrated on a combustor rig in VARIAnT3 and on a LGT-60 start cart in VARIAnT4, respectively. It was also found that the three mass instrument types (MSS, CAPS PMSSA, and LII-300) can exhibit different BC to reference EC ratios depending on the emission source that appear to correlate to particle geometric mean mobility diameter, morphology, or some other parameter associated with particle geometric mean diameter (GMD) with the LII-300 showing a slightly stronger apparent trend with GMD. Systematic differences in LII-300 measured mass concentrations have been reduced by calibrating with a turbine combustion source (combustor or turbine engine). With respect to the particle size measurements made, the sizing instruments (TSI SMPS, TSI EEPS, and Cambustion DMS 500) were found to be in general agreement in terms of size distributions and concentrations with some exceptions. Teflon filter measurements of the total aerosol mass produced by the various DFCASs differed from the reference EC, BC, and integrated particle sized distribution measured aerosol masses. The Teflon filter measured mass was 30 to 40% greater than the reference EC and 50 to 60% greater than the BC mass for the J85 in both test campaigns. The measurements of particle size distributions and single particle analysis by miniSPLAT indicated the presence of large particles (>100 nm) having more compact morphologies, higher effective density, and a composition dominated by OC and ash. This increased large particle fraction is also associated with higher values of single scattering albedo measured by the CAPS PMSSA instrument and higher OC/EC measurements. These measurements indicate gas turbine engine emissions can be a more heterogeneous mix of particle types beyond the original E31 assumption that it is mainly composed of black carbon.

33 ADVANCED PROPULSION SYSTEMS↗

Characterization of individual particles in gaseous media by mass spectrometry

An introduction is given to a system for particle analysis by mass spectrometry (PAMS) which employs particle-beam techniques to measure mass spectra on a continuous real-time basis. The system is applied to particles of both organic and inorganic compounds, and the measurements give the chemical characteristics of particles in mixtures and indicate source apportionment. The PAMS system can be used for process control and studying heterogeneous/catalytic reactions in particles, and can be fitted to study the real-time attributes of PAMS.

Sinha, M. P.↗

Micro-Raman spectroscopy: The analysis of micrometer and submicrometer atmospheric aerosols

A nondestructive method of molecular analysis which is required to fully utilize the information contained within a collected particle is discussed. Upper atmosphere reaction mechanisms are assessed when the chemical compounds, the use of micro-Raman spectrometric techniques to perform micron and submicron particle analysis was evaluated. The results are favorable and it is concluded that micron and submicron particles can be analyzed by the micron-Raman approach. Completely automatic analysis should be possible to 0.3 micro m. No problems are anticipated with photo or thermal decomposition. Sample and impurity fluorescence are the key source of background as they cannot be completely eliminated.

Klainer, S. M.↗

Analysis of solid uranium particulates on cotton swipes with an automated microextraction-ICP-MS system

Here, an automated microextraction method coupled to an inductively coupled plasma – mass spectrometer (ICP-MS) was developed for the direct analysis of solid uranium particulates on the surface of cotton swipes. The microextraction probe extracts particulates from the sample surface, in a flowing solvent, and directs the removed analyte to an ICP-MS for isotopic determination. The automated system utilizes a mechanical XY stage that is software controlled with the capability of saving and returning to specific locations and a camera focused to the swipe surface for optimal viewing of the extracted locations (i.e., material present). Here, particulates (n = 135) were extracted and measured by ICP-MS, including 35 depleted uranyl nitrate hexahydrate (UN) (used for mass bias corrections), 50 uranyl fluoride (UO 2 F 2 ), and 50 uranyl acetate (UAc) particulates. Blank extractions were performed on the cotton swipes between triplicate sample analyses. Between each swipe extraction, the probe was sent between two wells containing 10% and 5% HNO 3 to clean the probe head and to eliminate any analyte carryover between particulates. The measured 235 U/ 238 U and 234 U/ 238 U isotope ratios for the UO 2 F 2 particulates were 0.00725(8) and 0.000054(4), a percent relative difference (% RD) of –0.041% and –1.7% from the reference isotope ratios determined in-lab through multi-collector ICP-MS analysis of dissolved aliquots of the U material. The UAc samples had a measured 235 U/ 238 U isotope ratio of 0.00206(7), a –0.96% relative difference from the reference value of 0.00208(1). The 234 U/ 238 U and 236 U/ 238 U isotope ratios were 0.000008(1) and 0.000031(4), –5.1% RD and –4.3% RD, respectively. The automated sample stage enabled seamless and rapid particle analysis, leading to a significant increase in throughput versus what was previously possible. Additionally, the saved location capability reduced user sampling error as sampling locations were easily stored and recalled. Analysis of U particles on the swipe surface – including blanks, mass bias, and triplicate extractions – was completed in less than an hour without any sample preparation necessary.

47 OTHER INSTRUMENTATION↗

Multimodal Atomic Force Microscopy for the Characterization of Metallic Particulates

This study investigates the utility of multimodal, or functional, atomic force microscopy (AFM) for the characterization of individual particles and particle ensembles. In single-particle analyses, AFM imaging modes provided orthogonal insights into mechanical and magnetic properties that are not accessible through conventional electron microscopy. Although the experiments were inherently delicate and time-intensive, with an observed sample loss rate of approximately 30%, these techniques enabled the qualitative differentiation of grain structures and magnetic domains, underscoring the challenges of experimental robustness. For particle ensembles, AFM enabled the extraction of reliable 2D and 3D particle size distributions. However, efforts to chemically differentiate particles based on mechanical property contrasts were limited by scaling effects and the qualitative nature of the data. Overall, multimodal AFM offers valuable complementary information, but its application requires careful consideration of methodological limitations, particularly for sample integrity, calibration, and scalability of mechanical and magnetic measurements. This report is organized to first address the application of AFM to single-particle analysis using various imaging modalities, followed by its potential role in ensemble-level particle screening and differentiation.

36 MATERIALS SCIENCE↗

New Method Developed To Purify Single Wall Carbon Nanotubes for Aerospace Applications

Single wall carbon nanotubes have attracted considerable attention because of their remarkable mechanical properties and electrical and thermal conductivities. Use of these materials as primary or secondary reinforcements in polymers or ceramics could lead to new materials with significantly enhanced mechanical strength and electrical and thermal conductivity. Use of carbon-nanotube-reinforced materials in aerospace components will enable substantial reductions in component weight and improvements in durability and safety. Potential applications for single wall carbon nanotubes include lightweight components for vehicle structures and propulsion systems, fuel cell components (bipolar plates and electrodes) and battery electrodes, and ultra-lightweight materials for use in solar sails. A major barrier to the successful use of carbon nanotubes in these components is the need for methods to economically produce pure carbon nanotubes in large enough quantities to not only evaluate their suitability for certain applications but also produce actual components. Most carbon nanotube synthesis methods, including the HiPCO (high pressure carbon monoxide) method developed by Smalley and others, employ metal catalysts that remain trapped in the final product. These catalyst impurities can affect nanotube properties and accelerate their decomposition. The development of techniques to remove most, if not all, of these impurities is essential to their successful use in practical applications. A new method has been developed at the NASA Glenn Research Center to purify gram-scale quantities of single wall carbon nanotubes. This method, a modification of a gas phase purification technique previously reported by Smalley and others, uses a combination of high-temperature oxidations and repeated extractions with nitric and hydrochloric acid. This improved procedure significantly reduces the amount of impurities (catalyst and nonnanotube forms of carbon) within the nanotubes, increasing their stability significantly. The onset of decomposition of the purified nanotubes (determined by thermal gravimetric analysis in air) is more than 300 C higher than that of the crude nanotubes. Transmission electron microscopy analysis of nanotubes purified by this method reveals near complete removal of iron catalyst particles. Analysis of the nanotubes using inductively coupled plasma spectroscopy revealed that the iron content of the nanotubes was reduced from 22.7 wt% in the crude nanotubes to less than 0.02 wt%. X-ray photoelectron spectroscopy revealed a decrease in iron content after purification as well as an increase in oxygen content due to the formation of carboxylic acid groups on the surface of the nanotubes. Nanotubes purified by this improved method can be readily dispersed in common organic solvents, in particular N,N-dimethylformamide, using prolonged ultrasonic treatment. These dispersions can then be used to incorporate single wall carbon nanotubes into polymer films.

Lebron, Marisabel↗

Analytical workflow dependence of experimental observables for uranium chemistries

In this work, we investigated how the sequencing of laboratory analytical methods used for chemical and morphological characterization influences analytical findings for particulate materials relevant to the nuclear fuel cycle, including UO2, U3O8, studtite (UO2O2·4H2O), and β-UO3, in the context of nuclear forensic analysis. Particles of each chemistry obtained from consistent production batches were exposed to Raman spectroscopy and scanning electron microscopy in varying orders to elucidate how the order in which the techniques are applied influences morphological and chemical observations as a function of particle size. The results indicate that particles from all four chemistries exposed to high-resolution electron imaging before Raman spectral analysis demonstrate optical vibrational spectral changes that reduce accurate interpretation of the underlying chemistry via Raman spectral analysis. We hypothesize that these changes are due to the thermal load of the electron beam imparted to the sample being unable to be dissipated by materials with poor thermal conduction properties. Results from this study will aid in determining best practices for forensic analysis procedures to reduce uncertainty in chemical determination of unknown particulate samples.

Manns, Rebecca [University of Nevada, Las Vegas]↗

Continuum theories for fluid-particle flows: Some aspects of lift forces and turbulence

A general framework is outlined for the modeling of fluid particle flows. The momentum exchange between the constituents embodies both lift and drag forces, constitutive equations for which can be made explicit with reference to known single particle analysis. Relevant results for lift are reviewed, and invariant representations are posed. The fluid and particle velocities and the particle volume fraction are then decomposed into mean and fluctuating parts to characterize turbulent motions, and the equations of motion are averaged. In addition to the Reynolds stresses, further correlations between concentration and velocity fluctuations appear. These can be identified with turbulent transport processes such as eddy diffusion of the particles. When the drag force is dominant, the classical convection dispersion model for turbulent transport of particles is recovered. When other interaction forces enter, particle segregation effects can arise. This is illustrated qualitatively by consideration of turbulent channel flow with lift effects included.

Mctigue, David F.↗

Redistribution of radionuclides in irradiated AGR-1 UCO TRISO fuel after 1800 °C safety testing

Release of radionuclides from intact tristructural-isotropic (TRISO) coated particle fuel at normal and accident conditions is a primary metric of fuel performance. The distribution of fission products and actinides in the TRISO layers of individual particles provides insight on radionuclide transport and release behavior and was determined using scanning electron microscopy analysis. Particles were isolated from an irradiated fuel compact (AGR-1 Compact 4-4-2) and analyzed as-irradiated or after individual particle safety-testing at 1800 °C for 650 h. Particles were selected for comparison based on their remaining 110mAg fission product inventory. These comparisons corroborated the observation that the 110m Ag inventory is a marker for relative irradiation temperature based on observed radionuclide distribution in the SiC layer. The comparison also indicated that the in-pile behavior influences the fission product and actinide species interactions with the TRISO layers during high temperature exposure after irradiation. The analysis confirms both palladium and uranium diffusion, as well as other species, are active in the UCO TRISO fuel system at 1800 °C and that palladium transport is active at lower temperatures relative to uranium. While diffusion across the SiC layer was observed, the intact nature of the SiC layer after the 1800 °C, 650-h exposure indicates the SiC layer maintained its functionality as a fission product barrier by mitigating release of radionuclides at beyond accident margin temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Single particle trace element analysis of uranium oxide standards with laser-induced breakdown spectroscopy

Femtosecond Laser-Induced Breakdown Spectroscopy (LIBS) was used to analyze over 1000 individual particles of uranium oxide trace element standard CRM124. Intra-granular analysis showed elemental concentrations were consistent across different surface locations on each uranium grain. However, inter-granular comparison revealed large heterogeneity between different grains of the same sample. By comparing the distribution of elemental concentrations across the particle populations, we were able to correctly identify a manufacturing process involving wet chemistry, rather than a dry mixing of two powders to give an overall chemical average. In conclusion, this demonstrates the utility of LIBS as a large-scale single particle analysis tool for nuclear forensics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Real-time measurement of sodium chloride in individual aerosol particles by mass spectrometry

The method of particle analysis by mass spectrometry has been applied to the quantitative measurement of sodium chloride in individual particles on a real-time basis. Particles of known masses are individually introduced, in the form of a beam, into a miniature Knudsen cell oven (1600 K). The oven is fabricated from rhenium metal sheet (0.018 mm thick) and is situated in the ion source of a quadrupole mass spectrometer. A particle once inside the oven is trapped and completely volatilized; this overcomes the problem of partial volatilization due to particles bouncing from the filament surface. Individual particles are thermally volatilized and ionized inside the rhenium oven, and produce discrete sodium ion pulses whose intensities are measured with the quadrupole mass spectrometer. An ion pulse width of several milliseconds (4-12 ms) is found for particles in the mass range 1.3 x 10 to the -13th to 5.4 x 10 to the -11th g. The sodium ion intensity is found to be proportional to the particle mass to the 0.86-power. The intensity distribution for monodisperse aerosol particles possesses a geometric standard deviation of 1.09, showing that the method can be used for the determination of the mass distribution function with good resolution in a polydisperse aerosol.

Sinha, M. P.↗

Haze processing of atmospheric particles during wintertime in the Indo-Gangetic Plains

The impacts of haze on visibility, air quality, and climate are not well quantified due to a lack of understanding of the evolution of the mixing state and phase state of atmospheric particles during haze processing. The variability of the mixing state of atmospheric particles contributes significantly to uncertainties associated with the estimated aerosol radiative forcing. We collected particle samples in January 2018 from the highly polluted Indo-Gangetic plain during hazy conditions to study haze-processed particles. Single particle analysis using multi-modal micro-spectroscopy techniques revealed an abundance (40–70% by number) of potassium-rich sulfate particles from biomass-burning influenced smoke. Tilted view imaging showed that most of the organic particles that had inorganic potassium and sulfate inclusions were liquid-like while those without inclusions were more semi-solid. High-resolution mass spectrometry analysis revealed a significant presence of organosulfates and nitroxy-organosulfates in the morning samples (24%) compared to the afternoon samples (9%), despite higher relative humidity in the afternoon. Overall, our results highlight the significant contribution of both organic and inorganic sulfate to the total particulate sulfur budget during haze processing in winter, when anthropogenic emissions such as household burning, agricultural burning, and vehicular emissions are major contributors to particle mass.

Mathai, Susan [Pacific Northwest National Laborato↗

Using Dust from Asteroids as Regolith Microsamples

Meteorite science is rich with compositional indicators by which we classify parent bodies, but few sample groups are definitively linked with asteroid spectra. More robust links need to be forged between meteorites and their parent bodies to understand the composition, diversity and distribution. A major link can be sample analysis of the parent body material and comparison with meteorite data. Hayabusa, the first sample return mission of the Japanese Aerospace Exploration Agency (JAXA), was developed to rendezvous with and collect samples from asteroid Itokawa and return them to Earth. Thousands of sub-100 micron particles were recovered, apparently introduced during the spacecraft impact into the surface of the asteroid, linking the asteroid Itokawa to LL chondrites [1]. Upcoming missions Hayabusa 2 and OSIRIS-REx will collect more significant sample masses from asteroids. In all these cases, the samples are or will be a collection of regolith particles. Sample return to earth is not the only method for regolith particle analysis. Dust is present around all airless bodies, generated by micrometeorite impact into their airless surfaces, which in turn lofts regolith particles into a "cloud" around the body. The composition, flux, and size-frequency distribution of dust particles can provide significant insight into the geological evolution of airless bodies [2]. For example, the Cassini Cosmic Dust Analyzer (CDA) detected salts in Enceladus' icy plume material, providing evidence for a subsurface ocean in contact with a silicate seafloor [3]. Similar instruments have flown on the Rosetta, LADEE, and Stardust missions. Such an instrument may be of great use in obtaining the elemental, isotopic and mineralogical composition measurement of dust particles originating from asteroids without returning the samples to terrestrial laboratories. We investigated the ability of a limited sample analysis capability using a dust instrument to forge links between asteroid regolith particles and known meteorite groups. We further set limits on the number of individual particles statistically needed to robustly reproduce a bulk composition.

microsamples↗

Investigations on transparent liquid-miscibility gap systems

Sedimentation and phase separation is a well known occurrence in monotectic or miscibility gap alloys. Previous investigations indicate that it may be possible to prepare such alloys in a low-gravity space environment but recent experiments indicate that there may be nongravity dependent phase separation processes which can hinder the formation of such alloys. Such phase separation processes are studied using transparent liquid systems and holography. By reconstructing holograms into a commercial-particle-analysis system, real time computer analysis can be performed on emulsions with diameters in the range of 5 micrometers or greater. Thus dynamic effects associated with particle migration and coalescence can be studied. Characterization studies on two selected immiscible systems including an accurate determination of phase diagrams, surface and interfacial tension measurements, surface excess and wetting behavior near critical solution temperatures completed.

Lacy, L. L.↗