Search NASA⌕ Search

SEARCH · Search NASA

Results for “Photodiode arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Multispecies CARS measurements in turbulent combustion

A coherent anti-Stokes Raman scattering (CARS) instrument was upgraded to more accurately measure the number density of oxygen molecules. This instrument is designed to simultaneously measure nitrogen number density, oxygen number density, and the ro-vibrational temperature of nitrogen. The CARS is a nonintrusive diagnostic technique which utilizes a pulsed Nd:YAG laser, broadband dye lasers, a complex optical system, and an intensified photodiode array detector to sample hostile combustion environments. Measurements were made in a flame produced by a coaxial subsonic diffusion hydrogen-air burner. These data were used as a data base for comparison with the results of two separate computational fluid dynamics calculations. Complications which had arisen in previous studies with regard to interpretation of the oxygen data were eliminated.

Antcliff, Richard R.↗

Optical strain measurement system development

A laser speckle, differential strain measurement system has been built and tested for future applications in hostile environments. One-dimensional electronic correlation of speckle pattern movement allows a quasi-real time measure of strain. The system has been used successfully to measure uniaxial strain reaching into plastic deformation of a test specimen, at temperatures ranging to 450 C. A resolution of 16 microstrain is given by the photodiode array sensor pitch and the specimen to sensor separation. The strain measurement error is estimated to be +/-18 microstrain +/-3 percent of the strain reading. The upper temperature limit of the gauge is determined by air density perturbations causing decorrelation of the reference and shifted speckle patterns, and may be improved by limiting convective flow in the immediate vicinity of the test specimen.

Lant, Christian T.↗

High angle of attack position sensing for the Southampton University magnetic suspension and balance system

An all digital five channel position detection system is to be installed in the Southampton University Magnetic Suspension and Balance System (SUMSBS). The system is intended to monitor a much larger range of model pitch attitudes than has been possible hitherto, up to a maximum of a 90 degree angle of attack. It is based on the use of self-scanning photodiode arrays and illuminating laser light beams, together with purpose built processing electronics. The principles behind the design of the system are discussed, together with the results of testing one channel of the system which was used to control the axial position of a magnetically suspended model in SUMSBS. The removal of optically coupled heave position information from the axial position sensing channel is described.

Parker, David H.↗

Sun sensor boresight alignment testing for the Halogen Occultation Experiment

The boresight alignment testing for the sun sensor assembly on the Halogen Occultation Experiment (HALOE) is described. The sun sensor assembly consists of three sensors that provide feedback signals for controlling dual axes gimbals. Two energy balancing silicon detectors are operated as wideband sensors in the azimuth and elevation axes. The third sensor is a silicon photodiode array operated as a narrow-band sensor in the elevation axis. These sensors are mounted on a common Invar structure which is mounted to the HALOE telescope. A blackbody was used as the stimulating source to perform the initial boresight alignment and this was checked with a heliostat solar look and a direct solar look. These tests are explained with a comparison between each source used.

Moore, A. S.↗

Multispecies coherent anti-Stokes Raman scattering instrument for turbulent combustion

A nonintrusive diagnostic system is described which permits simultaneous measurement of temperature, nitrogen number density, and oxygen number density in hostile combustion environments. This system is pumped by a 10-Hz neodymium YAG laser, and signals are detected with an intensified photodiode array and dual photomultipliers. The system utilizes a folded BOXCARS beam arrangement, two probe dye lasers, dynamic range expansion, polarization rejection of nonresonant background, and multiplexing of the signal beams.

Antcliff, Richard R.↗

A five component electro-optical positioning system

The development of a five-component electrooptical positioning system for detecting the location of wind tunnel models within the test section is discussed. The system consists of three low power helium-neon lasers, five linear photodiode arrays, an assembly of optics that includes lenses and mirrors, and a signal conditioner. The system has been successfully installed and is currently in use at the 13-inch magnetic suspension and balance system (MSBS) at NASA Langley Research Center. Initially the system was developed as an auxiliary model position and attitude detecting system for that facility, but it has since been modified and interfaced with a PDP minicomputer to provide position feedback for the control loop.

Tcheng, Ping↗

Optical strain measurement system development

A laser speckle, differential strain measurement system has been built and tested for future applications in hostile environments. One-dimensional electronic correlation of speckle pattern movement allows a quasi-real time measure of strain. The system has been used successfully to measure uniaxial strain reaching into plastic deformation of a test specimen, at temperatures ranging to 450 C. A resolution of 126 microstrain is given by the photodiode array sensor pitch and the specimen to sensor separation. The strain measurement error is estimated to be +/-18 microstrain +/-3 percent of the strain reading. The upper temperature limit of the gauge is determined by air density perturbations causing decorrelation of the reference and shifted speckle patterns, and may be improved by limiting convective flow in the immediate vicinity of the test specimen.

Lant, Christian T.↗

Magnetic and electric field meters developed for the US Department of Energy

This report describes work done at the Jet Propulsion Laboratory for the Office of Energy Storage and Distribution of DOE on the measurement of power line fields. A magnetic field meter is discussed that uses fiber optics to couple a small measuring probe to a remote readout device. The use of fiber optics minimizes electric field perturbation due to the presence of the probe and provides electric isolation for the probe, so that it could be used in a high field or high voltage environment. Power to operate the sensor electronics is transferred via an optical fiber, and converted to electrical form by a small photodiode array. The fundamental, the second and third harmonics of the field are filtered and separately measured, as well as the broadband rms level of the field. The design of the meter is described in detail and data from laboratory tests are presented. The report also describes work done to improve the performance of a DC bushing in a Swedish factory, using the improved meter. The DC electric fields are measured with synchronous detection to provide field magnitude data in two component directions.

Kirkham, H.↗

Two-dimensional high temperature optical strain measurement system, phase 2

A laser speckle strain measurement system with two-dimensional measurement capabilities has been built and tested for high temperature applications. The 1st and 2nd principle strains at a point on a specimen are calculated from three components of one-dimensional strain. Strain components are detected by cross-correlating reference and shifted speckle patterns recorded before and after straining the specimen. Speckle patterns are recorded by a linear photodiode array camera. Accurate strains have been measured at temperatures up to 650 C. Stable speckle correlations and linear stress-strain relations have been demonstrated up to 750 C. The resolution of the system is 15 microstrains, with a gauge length less than 1 mm.

Lant, Christian T.↗

Application of the Langley plot for calibration of sun sensors for the Halogen Occultation Experiment (HALOE)

The calibration of the Halogen Occultation Experiment (HALOE) sun sensor is described. This system consists of two energy-balancing silicon detectors which provide coarse azimuth and elevation control signals and a silicon photodiode array which provides top and bottom solar edge data for fine elevation control. All three detectors were calibrated on a mountaintop near Tucson, Ariz., using the Langley plot technique. The conventional Langley plot technique was modified to allow calibration of the two coarse detectors, which operate wideband. A brief description of the test setup is given. The HALOE instrument is a gas correlation radiometer that is now being developed for the Upper Atmospheric Research Satellite.

Moore, Alvah S., Jr.↗

Techniques for extreme attitude suspension of a wind tunnel model in a magnetic suspension and balance system

Although small scale magnetic suspension and balance systems (MSBSs) for wind tunnel use have been in existence for many years, they have not found general application in the production testing of flight vehicles. One reason for this is thought to lie in the relatively limited range of attitudes over which a wind tunnel model may be suspended. Modifications to a small MSBS to permit the suspension and control of axisymmetric models over angles of attack from less than zero to over ninety degrees are reported. Previous work has shown that existing arrangement of ten electromagnets was unable to generate one of the force components needed for control at extreme attitudes. Examination of possible solutions resulted in a simple alteration to rectify this deficiency. To generate the feedback signals to control the suspended model, an optical position sensing system using collimated laser beams and photodiode arrays was installed and tested. An analytical basis was developed for distributing the demands for force and moment needed for model stabilization amonge the electromagnets over the full attitude range. This was implemented by an MSBS control program able to continually adjust the distribution for the instantaneous incidence in accordance with prescheduled data. Results presented demonstrate rotations of models from zero to ninety degrees at rates up to ninety degrees per second, with pitching rates rising to several hundred degrees per second in response to step-change demands. A study of a design for a large MSBS suggests that such a system could be given the capability to control a model in six degrees of freedom over an unlimited angle of attack range.

Parker, David Huw↗

A laser spectrometer and wavemeter for pulsed lasers

The design, construction, calibration, and evaluation of a pulsed laser wavemeter and spectral analyzer are described. This instrument, called the Laserscope for its oscilloscope-like display of laser spectral structure, was delivered to NASA Langley Research Center as a prototype of a laboratory instrument. The key component is a multibeam Fizeau wedge interferometer, providing high (0.2 pm) spectral resolution and a linear dispersion of spectral information, ideally suited to linear array photodiode detectors. Even operating alone, with the classic order-number ambiguity of interferometers unresolved, this optical element will provide a fast, real-time display of the spectral structure of a laser output. If precise wavelength information is also desired then additional stages must be provided to obtain a wavelength measurement within the order-number uncertainty, i.e., within the free spectral range of the Fizeau wedge interferometer. A Snyder (single-beam Fizeau) wedge is included to provide this initial wavelength measurement. Difficulties in achieving the required wide-spectrum calibration limit the usefulness of this function.

Mckay, J. A.↗

Automated measurement of birefringence - Development and experimental evaluation of the techniques

Traditional photoelasticity has started to lose its appeal since it requires a well-trained specialist to acquire and interpret results. A spectral-contents-analysis approach may help to revive this old, but still useful technique. Light intensity of the beam passed through the stressed specimen contains all the information necessary to automatically extract the value of retardation. This is done by using a photodiode array to investigate the spectral contents of the light beam. Three different techniques to extract the value of retardation from the spectral contents of the light are discussed and evaluated. An experimental system was built which demonstrates the ability to evaluate retardation values in real time.

Voloshin, A. S.↗

Electro-optical Position-Measuring System

Electro-optical system developed to measure five components of coordinates representing position and orientation of model in test section of wind tunnel. Located entirely outside test section, uses small lasers as sources of light and self-scanning linear photodiode arrays (LPDA's) as sensing elements. With improvements in measuring ranges, adapted for use in other aerodynamic applications.

Tcheng, Ping↗

A high resolution electro-optical displacement measurement system

An improved electrooptical system has been developed to sense wind tunnel model position. The original system using 25.6 mm, 1024-element linear photodiode arrays (PDAs) is being successfully used at a NASA wind tunnel but has a limited range. A new two-channel system using 61.44 mm, 4096-element PDAs has been developed to double the range of vertical and pitch measurement and increase the resolution by 60 percent. The PDAs are illuminated by expanding the beam of a single low power helium neon laser into a collimated sheet of light. An object placed in front of the two parallel PDAs produces a shadow on the array apertures which determines the object's position or size. The system has an overall precision of 12.7 microns and + or - 0.015 degrees in linear and angular measurements.

Schott, Timothy D.↗

Strain measurements using Fizzeau interferometry and photo-diode sensor in composite structures

A system is presented which allows the measurement of very small changes of strain in real time and can be applied to the design of stable space structures. The Fizzeau interferometry technique is employed in conjunction with a tube dilatometer to generate a fringe pattern that expands and contracts with temperature variations. A photodiode array transforms the bulls eye fringes to video signals which can be analyzed to determine the strain in structural elements such as tubes.

Syed, Hazari I.↗

Observation of alloy solidification using high-speed video

A high-speed video instrumentation system was used to observe solidification of undercooled Ti-51 at. pct Al. The camera system developed by Battelle is capable of operation at rates up to 12,000 frames per second. The system digitizes and stores video images acquired by a 64 x 64 pixel silicon photodiode array. In a joint effort with Vanderbilt University the camera was used to observe three transformations of the undercooled alloys, using containerless processing by electromagnetic levitation. The first was solidification where nucleation was induced at an undercooling of 9 percent Tl, where Tl is the liquidus temperature of the alloy, and the second was solidification where nucleation was spontaneous at an undercooling of 15 percent Tl. The third event was a solid-state nucleation and growth transformation following the solidification at an undercooling of 15 percent Tl.

Bassler, B. T.↗

OPAD 1991

The Optical Plume Anomaly Detection Program, an experimental study in the attempt to create a rocket engine health monitor based on detection and possible quantification of anomalous atomic and molecular species in the exhaust plume, has been in existence for several years. The instruments developed to monitor the exhaust plumes are presented. Two optical instruments are employed: the polychromator and the spectrometer. The polychromator is a 16 channel spectroradiometer having independent channels individually adjustable for center wavelength and pass bandwidth. Those values may be mechanically reset, with the aid of certain lab equipment. The spectrometer is a multichannel spectral analyzer having two 2048 element linear photodiode arrays at the exit plane of the dispersing instrument, which, like the 16 channel device, is a 1/2 meter grating spectrograph. These instruments are equipped with ultraviolet grade multifiber optical input cables, allowing the instruments to be placed in a benign environment. Telescopes mounted on the test stand observe the plume keeping the shock structure in view. The data acquisition and control system consist of four 80386-33 MHz computers: two at the test stand for instrument control and data preconditioning, and two in the test support building providing data archiving, display, and system control. Further descriptions of the instrumentation are provided.

Powers, W. T.↗