Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Web-Based System for Monitoring and Controlling Multidisciplinary Design Projects

In today's competitive environment, both industry and government agencies are under enormous pressure to reduce the time and cost of multidisciplinary design projects. A number of frameworks have been introduced to assist in this process by facilitating the integration of and communication among diverse disciplinary codes. An examination of current frameworks reveals weaknesses in various areas such as sequencing, displaying, monitoring, and controlling the design process. The objective of this research is to explore how Web technology, in conjunction with an existing framework, can improve these areas of weakness. This paper describes a system that executes a sequence of programs, monitors and controls the design process through a Web-based interface, and visualizes intermediate and final results through the use of Java(Tm) applets. A small sample problem, which includes nine processes with two analysis programs that are coupled to an optimizer, is used to demonstrate the feasibility of this approach.

Salas, Andrea O.↗

Tracking capability for entry, descent and landing and its support to NASA Mars Exploration Rovers

This paper described a new capability recently deployed in the NASA Deep Space Network to support the entry, descent and landing of the two Mars Exploration Rovers - Spirit and Opportunity. This final segment of a 7-month journey was critical step in enabling successful mission operation. The EDL Data Analysis (EDA) equipment processed the open loop recording samples from the existing radio science receivers, extracted the MFSK-modulated tones, and provided information on the occurrence of associated events happened onboard spacecraft. The EDA software supported real-time as well as post pass processing. The design flexibility allowed the track to be divided into different segments, each could be processed with a configuration optimized for its signal conditions and uncertainties. The use of dynamic lock state concept enabled signal detection be done with minimum required computing power - less was spent when signal was steadily detected and more when signal fluctuated. With the server-client design, the EDA supported connections to different remote operation centers for monitor purpose. The paper also presented the field results from both Spirit and Opportunity landings. The detection were much better than anticipated. All critical event tones were seen in real time. Surprising detection of LCP signal was found with Spirit landing, resulted in a reconfiguration for Opportunity landing to maximize signal detection.

tracking↗

The ANGSA Program: A Low-cost Lunar "Sample Return Mission". An Overview and Progress over the Last 18 Months

The Apollo Program returned 381 kg of samples. Analyses of these samples have provided fundamental insights into the origin and history of the Earth-Moon system and how planets and even solar systems work. These samples have provided ground truth for every post-Apollo mission to the Moon for the interpretation of remotely sensed data. After 50 years of analysis and study, our sophistication for handling and examining samples has greatly increased. Some special samples that were collected or preserved in unique containers or environments remain unexamined by standard or advanced analytical approaches. The Apollo Next Generation Sample Analysis (ANGSA) Program was designed to examine a subset of these special samples. The ANGSA consortium consists of 9 original teams funded by NASA that have combined into a single science team referred to as the ANGSA Science Team. The program was designed to function as the sample analysis portion of a sample return mission with processing, preliminary examination, and analyses utilizing new and improved technologies and recent mission observations. The ANGSA Program links the first generation of lunar explorers (Apollo) with future explorers of the Moon (Artemis). The purpose of this abstract is to highlight the ANGSA samples, science and engineering goals, and progress made so far. Related abstracts and talks will focus on the links between Apollo and Artemis, geologic context, and initial examination, processing, and results.

F M McCubbin↗

The Effect of Salts on Electrospray Ionization of Amino Acids in the Negative Mode

The continued search for organics on Mars will require the development of simplified procedures for handling and processing of soil or rock core samples prior to analysis by onboard instrumentation. Extraction of certain organic molecules such as amino acids from rock and soil samples using a liquid solvent (H2O) has been shown to be more efficient (by approximately an order of magnitude) than heat extraction methods. As such, liquid extraction (using H2O) of amino acid molecules from rock cores or regolith material is a prime candidate for the required processing. In this scenario, electrospray ionization (ESI) of the liquid extract would be a natural choice for ionization of the analyte prior to interrogation by one of a variety of potential analytical separation techniques (mass spectroscopy, ion mobility spectroscopy, etc.). Aside from the obvious compatibility of ESI and liquid samples, ESI offers simplicity and a soft ionization capability. In order to demonstrate that liquid extraction and ESI can work as part of an in situ instrument on Mars, we must better understand and quantify the effect salts have on the ESI process. In the current work, we have endeavored to investigate the feasibility and limitations of negative mode ESI of Martian surface samples in the context of sample salt content using ion mobility spectroscopy (IMS).

H I Kim↗

Soil developments in polar deserts: Implications for exobiology and future Mars missions

Chemical alterations, weathering, and diagenesis of soil profiles from the dry valleys of Antarctica were studied as analogs of regolith development for the Martian regolith. Chemical weathering processes play an important part in soil development within the dry valleys of Antarctica. A suite of core samples were studied which were taken within the valley floors in addition to samples taken in the vicinity of evaporite and brine ponds. Analysis of water soluable cations and anions from core samples were performed along with petrographic analysis of selected samples. It was shown that ionic transport processes operate primarily above the permafrost zone. Abundances of the water soluable ions reflect the nature of secondary minerals produced by evaporation and weathering. Chloride, calcium, and sodium abundances for soils from the cores within the North and South Forks of Wright Valley, reflect the secondary mineralogy of the soil columns. Calculations for Na, Ca, and Cl abundances reflect the appearance of halite and antarcticite. In areas where excess Ca is present, X-ray diffraction studies show the presence of gypsum. It is well known that the Martian surface conditions may be favorable for chemical weathering. Primary silicates would be expected to be reactive with any ground water. It seems likely that Martian subsurface water is available to assist in the weathering of the primary minerals. Such weathering could result in the formation of clays, sulfates, carbonates, hydrates, halides, and zeolites. The dry valley cores have shown that they maybe excellent analogs to weathering processes on the near-surface of Mars. Since movement of water within the near-surface region clearly results in chemical weathering, leaching, and salt formation in the dry valleys, similar processes are probably operating within the Martian regolith.

Gibson, Everett K., Jr.↗

Examples of Optical Assessment of Surface Cleanliness of Genesis Samples

Optical microscope assessment of Genesis solar wind collector surfaces is a coordinated part of the effort to obtain an assessed clean subset of flown wafer material for the scientific community. Microscopic survey is typically done at 50X magnification at selected approximately 1 square millimeter areas on the fragment surface. This survey is performed each time a principle investigator (PI) returns a sample to JSC for documentation as part of the established cleaning plan. The cleaning plan encompasses sample handling and analysis by Genesis science team members, and optical survey is done at each step in the process. Sample surface cleaning is performed at JSC (ultrapure water [1] and UV ozone cleaning [2]) and experimentally by other science team members (acid etch [3], acetate replica peels [4], CO2 snow [5], etc.). The documentation of each cleaning method can potentially be assessed with optical observation utilizing Image Pro Plus software [6]. Differences in particle counts can be studied and discussed within analysis groups. Approximately 25 samples have been identified as part of the cleaning matrix effort to date.

Rodriquez, Melissa C.↗

Life Science Research Facility materials management requirements and concepts

The Advanced Programs Office at NASA Ames Research Center has defined hypothetical experiments for a 90-day mission on Space Station to allow analysis of the materials necessary to conduct the experiments and to assess the impact on waste processing of recyclable materials and storage requirements of samples to be returned to earth for analysis as well as of nonrecyclable materials. The materials include the specimens themselves, the food, water, and gases necessary to maintain them, the expendables necessary to conduct the experiments, and the metabolic products of the specimens. This study defines the volumes, flow rates, and states of these materials. Process concepts for materials handling will include a cage cleaner, trash compactor, biological stabilizer, and various recycling devices.

Johnson, Catherine C.↗

A Compact, Solid-State UV (266 nm) Laser System Capable of Burst-Mode Operation for Laser Ablation Desorption Processing

Compared to wet chemistry and pyrolysis techniques, in situ laser-based methods of chemical analysis provide an ideal way to characterize precious planetary materials without requiring extensive sample processing. In particular, laser desorption and ablation techniques allow for rapid, reproducible and robust data acquisition over a wide mass range, plus: Quantitative, spatially-resolved measurements of elemental and molecular (organic and inorganic) abundances; Low analytical blanks and limits-of-detection ( ng g-1); and, the destruction of minimal quantities of sample ( g) compared to traditional solution and/or pyrolysis analyses (mg).

Laser↗

The NASA OSIRIS-REx Sample Catalog: Samples Returned from Investigators

OSIRIS-REx is a sample return mission that collected carbon-rich material from B-type asteroid Bennu. After landing on September 24th, 2023, the science canister was transported to NASA Johnson Space Center (JSC) in Houston, Texas where it was opened and samples were processed by the curation team in pristine sample nitrogen gloveboxes. As the sample analysis phase of the OSIRIS-REx mission concludes, the Sample Analysis Team (SAT) has returned the majority of mission samples to NASA JSC curation and will return the remaining samples on a defined timetable. The curation team processed and documented as many of these samples as possible to include in the spring 2026 catalog update and are steadily working to process hundreds of more samples to include in the fall 2026 catalog update.

OSIRIS-REx↗

Networks for image acquisition, processing and display

The human visual system comprises layers of networks which sample, process, and code images. Understanding these networks is a valuable means of understanding human vision and of designing autonomous vision systems based on network processing. Ames Research Center has an ongoing program to develop computational models of such networks. The models predict human performance in detection of targets and in discrimination of displayed information. In addition, the models are artificial vision systems sharing properties with biological vision that has been tuned by evolution for high performance. Properties include variable density sampling, noise immunity, multi-resolution coding, and fault-tolerance. The research stresses analysis of noise in visual networks, including sampling, photon, and processing unit noises. Specific accomplishments include: models of sampling array growth with variable density and irregularity comparable to that of the retinal cone mosaic; noise models of networks with signal-dependent and independent noise; models of network connection development for preserving spatial registration and interpolation; multi-resolution encoding models based on hexagonal arrays (HOP transform); and mathematical procedures for simplifying analysis of large networks.

Ahumada, Albert J., Jr.↗

Laser-zone growth in a Ribbon-To-Ribbon, RTR, process silicon sheet growth development for the large area silicon sheet task of the low cost silicon solar array project

A ribbon-to-ribbon process was used for routine growth of samples for analysis and fabrication into solar cells. One lot of solar cells was completely evaluated: ribbon solar cell efficiencies averaged 9.23% with a highest efficiency of 11.7%. Spherical reflectors have demonstrated significant improvements in laser silicon coupling efficiencies. Material analyses were performed including silicon photovoltage and open circuit photovoltage diffusion length measurements, crystal morphology studies, modulus of rupture measurements, and annealing/gettering studies. An initial economic analysis was performed indicating that ribbon-to-ribbon add-on costs of $.10/watt might be expected in the early 1980's.

Gurtler, R. W.↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatilizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vilicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Kuppermann, Aron↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vidicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Boettger, Heinz G.↗

Non-Contact Conductivity Measurement for Automated Sample Processing Systems

A new method has been developed for monitoring and control of automated sample processing and preparation especially focusing on desalting of samples before analytical analysis (described in more detail in Automated Desalting Apparatus, (NPO-45428), NASA Tech Briefs, Vol. 34, No. 8 (August 2010), page 44). The use of non-contact conductivity probes, one at the inlet and one at the outlet of the solid phase sample preparation media, allows monitoring of the process, and acts as a trigger for the start of the next step in the sequence (see figure). At each step of the muti-step process, the system is flushed with low-conductivity water, which sets the system back to an overall low-conductivity state. This measurement then triggers the next stage of sample processing protocols, and greatly minimizes use of consumables. In the case of amino acid sample preparation for desalting, the conductivity measurement will define three key conditions for the sample preparation process. First, when the system is neutralized (low conductivity, by washing with excess de-ionized water); second, when the system is acidified, by washing with a strong acid (high conductivity); and third, when the system is at a basic condition of high pH (high conductivity). Taken together, this non-contact conductivity measurement for monitoring sample preparation will not only facilitate automation of the sample preparation and processing, but will also act as a way to optimize the operational time and use of consumables

Beegle, Luther W.↗

Adapting Apollo-Era Instrumentation for Cold Sample Processing While Maintaining Curatorial Standard Practices

The goal of the Apollo Next Generation Sample Analysis (ANGSA) Program is to study “specially curated samples,” that is, unstudied Apollo samples that have been preserved under unique conditions. A subset of the funded ANGSA work includes the study of Apollo samples stored under cold conditions since their return from the Moon. Ongoing ANGSA processing and future returned samples require cold curation strategies to preserve the integrity of organic and other temperature-sensitive constituents within those samples. Standard Apollo curation processing hardware and procedures are designed for room temperature operations, not cold conditions. This abstract details the major modifications of a heritage lunar cabinet in preparation for the first cold curation processing at Johnson Space Center. Future publications will provide greater detail on the low temperature materials and operation procedures. This work not only supports Apollo but also future cold sample return missions.

Amick, Cecilia L.↗

Northwest Africa 8535 and Northwest Africa 10463: New Insights into the Angrite Parent Body

The angrite meteorites are valuable samples of igneous rocks formed early in Solar System history (approx.4.56 Ga, summarized in [1]). This small meteorite group (approx.24 individually named specimens) consists of rocks with somewhat exotic mineral compositions (e.g., high Ca olivine, Al-Ti-bearing diopside-hedenbergite, calcium silico-phosphates), resulting in exotic bulk rock compositions. These mineral assemblages remain fairly consistent among angrite samples, which suggests they formed due to similar processes from a single mantle source. There is still debate over the formation process for these rocks (see summary in [1]), and analysis of additional angrite samples may help to address this debate. Toward this end, we have begun to study two new angrites, Northwest Africa 8535, a dunite, and Northwest Africa 10463, a basaltic angrite.

Santos, A. R.↗

Automated Desalting Apparatus

Because salt and metals can mask the signature of a variety of organic molecules (like amino acids) in any given sample, an automated system to purify complex field samples has been created for the analytical techniques of electrospray ionization/ mass spectroscopy (ESI/MS), capillary electrophoresis (CE), and biological assays where unique identification requires at least some processing of complex samples. This development allows for automated sample preparation in the laboratory and analysis of complex samples in the field with multiple types of analytical instruments. Rather than using tedious, exacting protocols for desalting samples by hand, this innovation, called the Automated Sample Processing System (ASPS), takes analytes that have been extracted through high-temperature solvent extraction and introduces them into the desalting column. After 20 minutes, the eluent is produced. This clear liquid can then be directly analyzed by the techniques listed above. The current apparatus including the computer and power supplies is sturdy, has an approximate mass of 10 kg, and a volume of about 20 20 20 cm, and is undergoing further miniaturization. This system currently targets amino acids. For these molecules, a slurry of 1 g cation exchange resin in deionized water is packed into a column of the apparatus. Initial generation of the resin is done by flowing sequentially 2.3 bed volumes of 2N NaOH and 2N HCl (1 mL each) to rinse the resin, followed by .5 mL of deionized water. This makes the pH of the resin near neutral, and eliminates cross sample contamination. Afterward, 2.3 mL of extracted sample is then loaded into the column onto the top of the resin bed. Because the column is packed tightly, the sample can be applied without disturbing the resin bed. This is a vital step needed to ensure that the analytes adhere to the resin. After the sample is drained, oxalic acid (1 mL, pH 1.6-1.8, adjusted with NH4OH) is pumped into the column. Oxalic acid works as a chelating reagent to bring out metal ions, such as calcium and iron, which would otherwise interfere with amino acid analysis. After oxalic acid, 1 mL 0.01 N HCl and 1 mL deionized water is used to sequentially rinse the resin. Finally, the amino acids attached to the resin, and the analytes are eluted using 2.5 M NH4OH (1 mL), and the NH4OH eluent is collected in a vial for analysis.

Spencer, Maegan K.↗