At least 109 records · Page 6

A high accuracy gyroscope readout test facility for the relativity gyroscope experiment

An apparatus is under construction for ground-based testing of a gyroscope system to be used in a satellite test of general relativity. The immediate goal is a readout capable of measuring the direction of the gyroscope spin axis to an angular resolution of one arcsecond over a limited range. A combination of SQUID magnetometers and persistent current loops are used to measure the London moment of the spinning superconducting rotor levitated electrostatically. To obtain a trapped flux signal in the gyroscope sufficiently smaller than the London moment signal, the apparatus makes use of a new magnetic field shielding technique for obtaining large superconductor shielded regions below 0.1 millionth of a Gauss.

Cabrera, B.

Image readout device with electronically variable spatial resolution

An invention relating to the use of a standing acoustic wave charge storage device as an image readout device is described. A frequency f sub 1 was applied to the storage transfer device to create a traveling electric field in the device in one direction along a straight line. A second frequency f sub 2 was applied to the charge transfer device to create a traveling electric field opposite to the first traveling electric field. A standing wave was created. When an image was focused on the charge transfer device, light was stored in the wells of the standing wave. When the frequency f sub 2 is removed from the device, the standing wave tends to break up and the charges stored move to an electrode connected to an output terminal and to a utilization device where the received charges represent the image on the surface of the charge transfer device along a projection of said straight line.

Benz, H. A.

Electronic heterodyne readout of fringes in moire deflectometry

An electronic heterodyne technique is described for the readout of fringes in moire deflectometry. The technique is based on phase measurements of signals generated by a photodetector observing the light transmitted through a traveling moire fringe pattern. The phase of the signal is proportional to the fringe deviation and thus to the deflection angle of the light ray. The phase is measured on line by a standard phase meter with an accuracy of 1 deg or 1:360 of a fringe. The technique, which is precise and sensitive, is demonstrated by detecting and measuring a fringe shift of 0.15 mm corresponding to 0.029 of a fringe.

Stricker, J.

Wavelength error analysis in a multiple-beam Fizeau laser wavemeter having a linear diode array readout

An estimate of the wavelength accuracy of a laser wavemeter is performed for a system consisting of a multiple-beam Fizeau interferometer and a linear photosensor array readout. The analysis consists of determining the fringe position errors which result when various noise sources are included in the fringe forming and detection process. Two methods of estimating the fringe centers are considered: (1) maximum pixel current location, and (2) average pixel location for two detectors with nearly equal output currents. Wavelength error results for these two methods are compared for some typical wavemeter parameters.

Robinson, D. M.

Operational characteristics of Wedge and Strip image readout systems

Application of the Wedge and Strip readout system in microchannel plate detectors for the Extreme Ultraviolet Explorer and FAUST space astronomy programs is discussed. Anode designs with high resolution (greater than 600 x 600 pixels) in imaging and spectroscopy applications have been developed. Extension of these designs to larger formats (100 mm) with higher resolution (3000 x 3000 pixels) are considered. It is shown that the resolution and imaging are highly stable, and that the flat field performance is essentially limited by photon statistics. Very high speed event response has also been achieved with output pulses having durations of less than 10 nanoseconds.

Siegmund, O. H. W.

dc electric field meter with fiber-optic readout

The design of a dc electric field meter capable of measuring the magnitude and direction of the electric field at an arbitrary location above the ground plane is described. The meter is based on measuring induced charge on a split cylindrical electrode pair which is rotated around its axis of symmetry. Data readout is by fiber-optic cable using pulse frequency encoding. The sensing head is electrically isolated. Initial results are reported from a series of tests at General Electric's High Voltage Transmission Research Facility, Pittsfield, MA. The electric field was measured in a large test cage and under a dc test line. Measurement of field magnitude and direction around a human subject standing under the conductor was demonstrated.

Johnston, Alan R.

SQUID readout and ultra-low magnetic fields for Gravity Probe-B (GP-B)

The superconducting readout system to be used for resolving 0.001 arcsec changes in the gyroscope spin direction in the Relativity Gyroscope (GP-B) experiment is described. This system couples the London magnetic moment flux of the spinning gyro to a low noise superconducting quantum interference device (SQUID) detector. Resolution limits and noise performance of the detection system are discussed, and improvements obtained and expected with advanced SQUIDs are presented. Also described is the novel use of superconducting magnetic shielding techniques to obtain a 250 dB attenuation of the earth's magnetic field at the location of the gyroscopes. In this approach, expanded superconducting foil shields are coupled with fixed cylindrical superconducting shields and special geometric considerations to obtain the extremely high attenuation factor required. With these shielding techniques, it appears that the 0.5-Gauss earth field (which appears to the gyroscopes as an ac field at the satellite roll rate) can be reduced to the 10 to the -13th G level required by the experiment. Recent results concerning improvements in the performance of the superconducting foil techniques obtained with the use of a new computer-controlled cooling system are presented.

Lockhart, James M.

Readout techniques for photon-counting microchannel image systems

A comparative evaluation is made of such readout methods for the microchannel plates that are commonly used in EUV, FUV, and X-ray low light level image systems as the (1) phosphor-video, (2) phosphor and binary-mask encoder, (3) direct discrete-position encoder, (4) direct analog amplitude position-encoder systems, and (5) delay-line encoders. Relative advantages and limitations are discussed in the context of low light level space-based astronomy applications. The delay-line technique offers great promise for high-resolution applications where oversampling is mandatory, as in spectroscopy.

Lampton, Michael

High pressure gas scintillation drift chambers with wave shifter fiber readout. I

The authors present results from a prototype xenon-gas scintillation drift chamber. It was operated at pressures up to 20 atm, and the scintillation light yield was measured at various pressures and reduced fields. Scintillation-reduced fields ranged from 1.3 to 3 kV/cm/atm in a 5.4-mm scintillation gap. Drift fields ranged from 45 to 100 V/cm/atm in an 8-cm drift region. The chamber was exposed to an 241Am source in a port either 2.7 or 5.4 cm from the secondary scintillation region. The authors also describe the high-voltage problems encountered during operation at high pressures. Further tests with the wave shifter fiber readout showed that the problem of gas contamination by the fibers is manageable but that the interaction between the optical fibers and the high-pressure xenon gas can lead to fiber damage. A solution to this problem is described.

Parsons, A.

Laboratory characterization of direct readout Si:Sb and Si:Ga infrared detector arrays

Highlights of recent results obtained at Ames Research Center in performance evaluations of infrared detector arrays are presented. Antimony- and gallium-doped silicon direct readout 58x62 element hybrid devices from Ames' ongoing detector technology development program are described. The observed characteristics meet most of the performance goals specified by the Space Infrared Telescope Facility (SIRTF) instrument teams and compare favorably with the best performance reported for discrete non-integrating extrinsic silicon detectors. Initial results of radiation environment testing are reported, and non-ideal behavior demonstrated by these test devices is discussed.

Mckelvey, Mark E.

High pressure gas scintillation drift chambers with wave-shifter fiber readout. II

Results from a prototype high-pressure xenon gas scintillation drift chamber using a novel wave-shifter fiber readout scheme are presented. The primary scintillation light yield was measured to be one photon per 76 + or - 12 eV deposited energy. Initial results on the chamber are presented for two-interaction separation (less than 4 mm in the drift direction and about 7 mm orthogonal to the drift); for position resolution (less than 400 microns rms in the plane orthogonal to the drift direction); and for energy resolution (less than 6 percent FWHM at 122 keV).

Parsons, A.

Planar double delay-line readout technique for microchannel plate detectors

A two-dimensional position-sensitive electrical readout system for microchannel plate detectors in spectroscopic applications has been devised. Two adjacent parallel coplanar delay lines are used. The difference in time of arrival of the electron event signal between the ends of the delay lines gives one coordinate of the centroid of each event pulse. The ratio of the event amplitudes on the two delay lines gives the orthogonal coordinate by means of charge partitioning. The performance characteristics of operational double delay lines for systems of this type are presented.

Lampton, M.

A high resolution delay line readout for microchannel plates

Investigations are reported of delay line configurations used to encode photon event locations in microchannel plate (MCP) detectors. Several delay line schemes of planar and multilayer structure are discussed. The importance of the delay line substrate material is examined, and it is shown that the raw signals from delay lines are narrow (about 3-4 ns FWHM). The factors determining the delay line resolution are evaluated, and it is demonstrated that these are in agreement with measurements. Resolutions of about 18-micron FWHM have been achieved. Measurements of the linearity of the delay line readout show that event centroid locations deviate from perfect linearity by less than 50 microns, even with the very simple anode fabrication methods employed. The image stability has also been evaluated and it is shown that image shifts are less than one resolution element over a period of two months.

Siegmund, O. S. W.

Multiplexing readout channels in proportional counters

Proportional counters are important instruments used in sensing hard x-rays. The possibility is described of doubling the number of readout channels in the detector without increasing the electronics needed to amplify channel signals. This suggests that it should be possible, conversely, to reduce the number of amplifiers, thereby reducing the weight and energy budget of the instrument. Various numerical multiplexing schemes are analyzed, and a computer program is presented that can reconstruct multiplexed channel outputs with very good accuracy.

Caristi, James

Optical Link For Readout From Focal-Plane Array

Outputs of photodetectors modulate beam of light. Proposed optical link carries analog readout signals from photodetectors in focal-plane array to external signal-processing circuitry. Insensitive to electromagnetic interference at suboptical frequencies, and imposes smaller heat load on cryogenic apparatus because it does not include high-power electronic amplifier or laser transmitter within cold chamber.

Fossum, Eric R.

Rapid, Nondestructive Readout From Ferroelectric Memory

Proposed devices with nondestructive readout offer attractive alternatives for rugged, solid-state memories suitable for contactless optical addressing and parallel processing and for nonvolatile analog memories. Pulses of light from lasers induce photoresponses in ferroelectric capacitors. Magnitude and polarity of response of each capacitor indicates magnitude and polarity of remanent polarization which, in turn, represents datum stored in that memory cell.

Thakoor, Sarita

Gamma-ray astronomy using a high pressure gas scintillation drift chamber with a waveshifting fiber readout

We describe a balloon-borne hard X-ray telescope called SIGHT (Scintillation Imaging Gas-filled Hard X-ray Telescope). SIGHT is a high sensitivity, good energy resolution instrument that images in the 30 to 300 keV region. We discuss the development of a large area, 20 atmosphere, position sensitive xenon gas scintillation drift chamber which is the gamma-ray detector at the heart of the telescope package. Results of the development of the novel waveshifting fiber readout for this chamber are presented.

Wilkerson, J.

Compensated digital readout family

ISC has completed test on an IC which has 32 channels of amplifiers, low pass anti-aliasing filters, 13-bit analog-to-digital (A/D) converters with non-uniformity correction per channel and a digital multiplexer. The single slope class of A/D conversion is described, as are the unique variations required for incorporation of this technique for use with on-focal plane detector readout electronics. This paper describes the architecture used to implement the digital on-focal plane signal processing functions. Results from measured data on a test IC are presented for a circuit containing these functions operating at a sensor frame rate of 1000 hertz.

Ludwig, David E.