Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗

Impact of tracking resolution on 𝜙-meson spin alignment measurements

Measurements of global spin alignment of vector mesons in relativistic heavy-ion collisions can provide unique insights into spin-orbit interactions and vector meson dynamics in the quark-gluon plasma produced in those collisions. The global spin alignment is measured by the 00th coefficient of the spin density matrix, 𝜌 00 , via the polar angle (𝜃*) of the decay-kaon momentum in the parent rest frame with respect to the direction of the orbital angular momentum of the collision. Such measurements are affected by the angular and momentum resolutions of the reconstructed tracks in the experiment. Such effects are nontrivial because of kinematic complications caused by the boost to the parent rest frame, and could be important given that the global spin alignment signal is weak. In this paper, we investigate the effects of experimental tracking resolutions on measurements of the 𝜙 (1020) meson 𝜌 00 . We study these effects for two methods of 𝜌 00 measurements, the conventional method analyzing the 𝜙⁢−meson yield versus cos 2 ⁡𝜃* and the invariant mass (𝑚 inv ) method utilizing ⟨cos 2 ⁡𝜃*⟩ versus 𝑚 inv . Using typical resolution values from experiments, we find that the effect of track resolution on 𝜌 00 is small, well within typical measurement uncertainties.

Relativistic heavy-ion collisions↗

High-luminosity meV-resolution single-shot hard X-ray spectrograph for cavity-based X-ray free-electron lasers

Cavity-based X-ray free-electron lasers (CBXFELs) represent a possible realization of fully coherent hard X-ray sources having high spectral brilliance along with a narrow spectral bandwidth of ∼1–50 meV, a high repetition pulse rate of ∼1 MHz, and good stability. A diagnostic tool is required to measure CBXFEL spectra with meV resolution and high luminosity on a shot-to-shot basis. We have designed a high-luminosity single-shot hard X-ray spectrograph that images 9.831 keV X-rays in a ∼200 meV spectral window with a spectral resolution of a few meV. The spectrograph is designed around angular dispersion of X-rays in Bragg diffraction from crystals. It operates close to design specifications, exhibiting a linear dispersion rate of ∼1.4 µm meV −1 and a ∼200 meV window of high-fidelity spectral imaging. The experimentally demonstrated spectral resolution is ∼20 meV; this resolution is twice as low as expected from theory primarily because the spectrograph is highly sensitive to crystal angular instabilities. The experiment was performed at the bending magnet X-ray optics testing beamline 1-BM at the Advanced Photon Source.

Bragg diffraction↗

sup3ruhi (Super Resolution for Renewable Resource Data and Urban Heat Islands) [SWR-25-05]

Urban heat is a growing concern, particularly in dense metropolitan areas where high temperatures increase the risk of heat-related illness and drive energy expenses for cooling. Estimating the effects of urban heat remains a challenge due to limitations in describing the built environment, computational constraints, and the need for high-resolution data. This software presents open-source, computationally efficient machine learning methods that enhance the accuracy of urban temperature estimates compared to historical reanalysis data. Models trained using this software have been applied to urban microclimates in Los Angeles and Seattle showing greater accuracy and less bias when compared to low-resolution reanalysis datasets like ERA5 and even when compared to high-resolution mesoscale numerical weather models like WRF with an urban canopy model. Initial findings highlight how machine learning can support urban heat resilience planning by enabling improved assessments of local heat islands, mitigation strategies, and their energy implications. This software is an extension of (sup3r). This software supports the following publication: Buster, Grant, et al. Tackling Extreme Urban Heat: A Machine Learning Approach to Assess the Impacts of Climate Change and the Efficacy of Climate Adaptation Strategies in Urban Microclimates. arXiv:2411.05952, arXiv, 8 Nov. 2024. arXiv.org, https://doi.org/10.48550/arXiv.2411.05952. And has related public data records available at: Buster, Grant, Cox, Jordan, Benton, Brandon, and King, Ryan. Super-Resolution for Renewable Resource Data and Urban Heat Islands (Sup3rUHI). United States: N.p., 16 Oct, 2024. Web. https://data.openei.org/submissions/6220.

Buster, Grant [National Renewable Energy Laborator↗

Stochastic frequency fluctuation super-resolution imaging

The inherent non-linearity of intensity correlation functions can be used to spatially distinguish identical emitters beyond the diffraction limit, as achieved, for example, in super-resolution optical fluctuation imaging (SOFI). Here, we propose a complementary concept based on spectral correlation functions, termed spectral fluctuation super-resolution (SFSR) imaging. Through theoretical and computational analysis, we show that spatially resolving time-frequency correlation functions in the image plane can improve the imaging resolution by a factor of $\sqrt2$ in most cases and up to twofold for strictly two emitters. This improvement is achieved by quantifying the degree of correlation in spectral fluctuations across the spatial domain. Experimentally, SFSR can be implemented using a combination of interferometry and photon-correlation measurements. The method works for non-blinking emitters and stochastic spectral fluctuations with arbitrary temporal statistics. This suggests its utility in super-resolution microscopy of quantum emitters at low temperatures, where spectral diffusion is often more pronounced than emitter blinking.

47 OTHER INSTRUMENTATION↗

Enabling Ultralow Volume Analysis with a High-Resolution Ion Mobility Mass Spectrometry Platform

Of all the molecules thought to exist in the universe, it is estimated that researchers only know the chemical structures of 5% of them. Identifying the chemical structures of the remaining 95% has proven extremely challenging because many molecules exhibit low abundance, are contained in small volumes (e.g., <10 nL), do not readily ionize, exhibit similar structures to other molecules, etc. No single analytical technique exists to definitively identify the structure of an unknown molecule, and thus multiple different molecular measurements are typically made (i.e., multi-modal approach). Ion mobility (IMS) and mass spectrometry (MS) are two key tools that researchers use to determine the chemical structures of unknown molecules, and recently high-resolution and ultrahigh resolution IMS-MS instruments have provided greater confidence than ever before. However, HR-IMS-MS instruments typically exhibit low ion utilization efficiency, meaning they require large amounts of sample for an analysis (e.g., >10 µL). Unfortunately, this limitation prohibits the analysis of small volume samples where many unknown molecules exist. Described herein are the efforts made to enable the analysis of ultralow volumes with an HR-IMS-MS platform. A new scanning technique, termed a ‘stuttered traveling wave scan’, was developed as a replacement for the dual-gated scanning technique and works by halting the traveling waves after allowing ions to separate and then repeatedly restarting and stopping the traveling waves to incrementally move ions from the SLIM to the Orbitrap. Ions were stored inside the SLIM while the TWs were stopped, allowing the Orbitrap to perform high-resolution mass analysis. When the Orbitrap was ready, the TWs were restarted for short periods of time (<10 ms) to move ions from the SLIM to the Orbitrap. It was discovered that lower TW amplitudes and speeds than used during IMS separation were required to produce IMS peaks with the highest signal intensities and best resolving powers. The stuttered TW scan was found to produce similar resolutions and signal intensities compared to the dual-gated scanning technique. A new IMS design possessing an intersecting ‘tee’ with a reversible traveling wave was also developed to improve ion utilization efficiency during cyclic operation, which is necessary when only a single IMS spectrum can be acquired, such as when analyzing ultralow volume samples. The new capabilities described in this report lay the groundwork for acquiring HR-IMS-MS spectra of ultralow volume biological samples, such as single cells, where HR-IMS-MS can help elucidate the structures of unknown compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Resolution Computed Tomography Dataset of Mount Simon Sandstone

The Illinois Basin is a critical structure for subsurface energy related activities and their implementation in the United States. The Mount Simon Sandstone has been identified as a storage target for permanent and transient storage of fluids in the basin. Known for its exceptional thickness, depth, porosity, and sealing properties of overlying formations, this saline reservoir is crucial for long-term subsurface energy efforts. We present an extensive Computed Tomography (CT) dataset on a high porosity and permeability zone in the lower Mount Simon Sandstone available on the Energy Data eXchange® (EDX). This publicly accessible database comprises over 500 GB of high-resolution CT scans of six core samples, with resolutions ranging from 14.8 µm to 0.7 µm per pixel. The scans include both dry sandstone samples and those saturated with multiple fluids, allowing for comparative analyses across different conditions and resolutions. Coarser scans capture the bedding structure of the sandstone, while finer resolutions reveal detailed pore infill and throat characteristics. Metadata on location, depth, and saturation state enhance usability, enabling quick identification and cross-sample comparisons. By providing a robust resource for research and collaboration, the database contributes to domestic energy advancement by supporting continued progress in the use of the subsurface for energy solutions.

characterization↗

Optimize Electron Beam Energy toward In Situ Imaging of Thick Frozen Bio-Samples with Nanometer Resolution Using MeV-STEM

To optimize electron energy for in situ imaging of large biological samples up to 10 μm in thickness with nanoscale resolutions, we implemented an analytical model based on elastic and inelastic characteristic angles. This model has been benchmarked by Monte Carlo simulations and can be used to predict the transverse beam size broadening as a function of electron energy while the probe beam traverses through the sample. As a result, the optimal choice of the electron beam energy can be realized. In addition, the impact of the dose-limited resolution was analysed. While the sample thickness is less than 10 μm, there exists an optimal electron beam energy below 10 MeV regarding a specific sample thickness. However, for samples thicker than 10 μm, the optimal beam energy is 10 MeV or higher depending on the sample thickness, and the ultimate resolution could become worse with the increase in the sample thickness. Moreover, a MeV-STEM column based on a two-stage lens system can be applied to reduce the beam size from one micron at aperture to one nanometre at the sample with the energy tuning range from 3 to 10 MeV. In conjunction with the state-of-the-art ultralow emittance electron source that we recently implemented, the maximum size of an electron beam when it traverses through an up to 10 μm thick bio-sample can be kept less than 10 nm . This is a critical step toward the in situ imaging of large, thick biological samples with nanometer resolution.

36 MATERIALS SCIENCE↗

Evaluation of a high-resolution regional climate simulation for surface and hub-height wind climatology over North America

Assessing the availability of key wind resources requires augmenting observations to support the implementation of wind energy infrastructure. However, observations are limited, necessitating the development of high-resolution, long-term gridded datasets. This study presents a robust, dynamically downscaled climatological dataset, offering 20 years of hourly wind data at a 4 km spatial resolution across North America, and evaluates its performance against observations, including meteorological towers and automated surface-observing system (ASOS) stations, as well as coarse-resolution reanalysis data (the European Centre for Medium-Range Weather Forecasts (ECMWF) reanalysis version 5 (ERA5)). Results demonstrate that the downscaled high-resolution wind data outperform ERA5 in regions of complex terrain and coastal areas, with improved overlap coefficients for wind data distributions and reduced root mean square errors (RMSEs) for hub-height and near-surface diurnal wind patterns. The downscaled simulation also captures the synoptic drivers of seasonal wind direction patterns reasonably well, indicated by high wind rose similarity indices. This study also provides an analysis of interannual variability, utilizing the dataset's full 20-year period, and model uncertainty, generated by varying model initial conditions and physics parameterizations across 1-year ensemble members, which are key considerations for wind resource assessment in wind farm development.

17 WIND ENERGY↗

Resolution requirements for high-speed droplet impact along a rigid wall

The mechanical and thermal loads that are produced on high-speed projectiles from a droplet are key in the projectile development.To accurately predict the pressure produced along the wall surface during impact, it is important to correctly model the air/water interface of the droplet. Novel modeling approaches such as the Phase-Field enable control of the (numerical) interface thickness. However, the interplay between the grid resolution (including potential adaptive mesh refinement) and the interface thickness is unclear. In this work, the resolution requirements for numerical simulations of a two-dimensional cylindrical water droplet impacting a rigid wall at Mach four are computationally investigated. Numerical simulations are performed using a second-order accurate scheme with adaptive mesh refinement and a Phase-Field interface model. The choice of numerical interface thickness and resolution parameters affects the maximum pressure and location of the maximum pressure along the wall. The overall maximum pressure does not converge even at high resolutions. The number of levels and thickness (number of cells across the interface) play a role in obtaining a well behaved solution.

Burrell, E.↗

SHF: Symmetrical Hierarchical Forest with Pretrained Vision Transformer Encoder for High-Resolution Medical Segmentation

This paper presents a novel approach to addressing the long-sequence problem in high-resolution medical images for Vision Transformers (ViTs). Using smaller patches as tokens can enhance ViT performance, but quadratically increases computation and memory requirements. Therefore, the common practice for applying ViTs to high-resolution images is either to: (a) employ complex sub-quadratic attention schemes or (b) use large to medium-sized patches and rely on additional mechanisms within the model to capture the spatial hierarchy of details. We propose Symmetrical Hierarchical Forest (SHF), a lightweight approach that adaptively patches the input image to increase token information density and encode hierarchical spatial structures into the input embedding. We then apply a reverse depatching scheme to the output embeddings of the transformer encoder, eliminating the need for convolution-based decoders. Unlike previous methods that modify attention mechanisms or use a complex hierarchy of interacting models, SHF can be retrofitted to any ViT model to allow it to learn the hierarchical structure of details in high-resolution images without requiring architectural changes. Experimental results demonstrate significant gains in computational efficiency and performance: on the PAIP WSI dataset, we achieved a 3∼32×speedup or a 2.95%∼7.03% increase in accuracy (measured by Dice score) at a 64K2 resolution with the same computational budget, compared to state-of-the-art production models. On the 3D medical datasets BTCV and KiTS, training was 6×faster, with accuracy gains of 6.93% and 5.9%, respectively, compared to models without SHF.

Zhang, Enzhi [Hokkaido University, Japan]↗

Intrinsic energy and time resolution of the Jefferson Lab Hall C Neutral Particle Spectrometer

The Neutral Particle Spectrometer (NPS) is an advanced calorimeter designed to measure neutral electro- magnetic particles with high precision in energy, time, and position, under conditions of high luminosity and significant background. Integrated into the experimental setup of Hall C at Thomas Jefferson National Accelerator Facility, the NPS plays a critical role in studies of nucleon structure through exclusive and semi- inclusive reaction channels. Here, this paper presents an assessment of the detector’s performance characteristics, specifically its energy and timing resolution, derived from elastic electron–proton scattering data. We report an energy resolution between 1.2% and 1.3% in the 4.5–7.3 GeV range, and an intrinsic timing resolution better than 200 ps for energies above 500 MeV. These results serve as a reference for current and future precision measurements in hadronic physics.

Detector performance↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

High spatial resolution neutron imaging of lithium-ion batteries: Correlating microstructure and lithium transport

Thick electrodes for lithium-ion batteries can increase the overall energy density, but increasing the electrode thickness introduces charge transport limitations. These limitations may be mitigated through proper electrode structuring. Here, high spatial resolution neutron imaging was used to understand the correlation between microstructure and lithium transport in lithium-ion anodes. Batteries with distinct graphite anode microstructures were produced and studied with high spatial resolution in operando neutron radiography to observe the effects of structure on transport. High spatial resolution neutron computed tomography was performed following in operando neutron radiography. X-ray computed tomography and scanning electron microscopy were used to observe the finer scale anode structure to complement neutron imaging. Solvent-free anodes containing a tightly-packed layered structure confined lithium movement close to the separator. This structure limited capacity, but supported better rate capability. Conversely, a more open pore structure in the wet cast anodes yielded higher capacity with reduced rate capability. Together, these results show that lithium distributions can be controlled by the macroscopic structure of the electrodes, the microstructural pore network, and the microscale active areas that support electrochemical reactions. Furthermore, multimodal imaging applying the complementary strengths of neutron and X-ray methods is shown as a tool for advancing battery design.

25 ENERGY STORAGE↗

Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion’s adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N 2 complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm –1 spectral range) can be recorded in as short as 2 s for high throughput measurements. Further, this work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Strategies for Overcoming Resolution Limits in Electron Beam Lithography of Chemically Amplified Resists

Electron beam lithography (EBL) of chemically amplified resists (CARs) faces fundamental challenges, including stochastic electron scattering and acid diffusion, that limit resolution and reproducibility. Using SU-8 as a model CAR, this study systematically investigated complementary strategies to address these challenges, combining multipass exposure, proximity effect correction (PEC) with midrange correction factors, base quencher incorporation, and post-exposure bake (PEB) suppression. Monte Carlo simulations and calibrated PEC modeling revealed that extending the point spread function to include a midrange scattering component significantly improved critical dimension (CD) control across varying pattern densities, correcting deviations that conventional two-term PEC failed to capture. Multipass exposure, particularly 4-pass writing with a 25% offset, redistributed the dose to average stochastic beam and scattering fluctuations, reducing line-width roughness by more than 50% and yielding more uniform nanoscale features. Photoacid confinement was investigated by adding urea as a base quencher, which successfully reduced acid diffusion but introduced substantial sensitivity penalties without improving ultimate resolution or Z-factor performance, underscoring the trade-offs of chemical versus physical confinement. Suppressing PEB most directly minimized acid diffusion, resulting in improved Z-factors and reproducible 30 nm half-pitch dense line/space patterns. Overall, these results demonstrated that PEC with midrange correction, multipass strategies, quencher additives, and PEB-free processing addresses different aspects of the EBL process window and that their integration provides a comprehensive framework for managing stochastic scattering, diffusion, and chemical amplification effects. This framework advances dense nanoscale patterning in CARs and establishes guiding principles for optimizing resist design and process strategies in high-resolution EBL and potentially other advanced lithographies, such as extreme ultraviolet (EUV) lithography.

36 MATERIALS SCIENCE↗

Enhanced Simulation of Atmospheric Blocking in a High‐Resolution Earth System Model: Projected Changes and Implications for Extreme Weather Events

Atmospheric blocking is closely linked to the occurrence of extreme weather events. However, low-resolution Earth system models often underestimate the frequency of blocking, undermining confidence in future projections. Here, in this study, we use the high-resolution Community Earth System Model (CESM-HR; 25 km atm and 10 km ocean) to show that CESM-HR reduces biases in atmospheric blocking for both winter and summer, particularly for events lasting longer than 10 days. This improvement is partly due to reduced sea surface temperature biases at higher resolution. Additionally, applying a bias correction to the 500 hPa geopotential height further enhances blocking frequency simulations, highlighting the crucial role of the mean state. Under the Representative Concentration Pathway 8.5 scenario, CESM-HR projects a decrease in wintertime blocking over regions such as the Euro-Atlantic and Chukchi-Alaska, consistent with previous studies. In contrast, summer blocking is expected to become more frequent and persistent, driven by weakened zonal winds. The blocking center shifts from historical locations over Scandinavia and eastern Russia to central Eurasia, significantly increasing blocking over the Ural region. Summer blocking frequency over the Scandinavia-Ural region may eventually surpass historical winter blocking over the Euro-Atlantic. This increase in summer blocking could exacerbate summer heatwaves in a warming climate, making severe heatwaves, like those observed recently, more common in the future.

Atmospheric blocking↗

Desmearing small-angle scattering data by central moment expansions of instrument resolution

This study introduces an enhanced numerical technique tailored specifically for refining 1D small-angle scattering (SAS) intensity profiles affected by smearing. Our primary objective is to address the resolution blurring commonly encountered in SAS data, particularly in systems with clearly defined correlation peaks whose spread aligns with the width of the resolution function at corresponding Q positions. Unlike previous approaches that expanded the SAS intensity using central moment expansion, the new method focuses on expanding the resolution function itself, thus eliminating artificial oscillations observed in smeared spectra due to limitations inherent in our earlier algorithm. This method is straightforward to implement, computationally efficient and consistently performs well in numerical benchmarking. To illustrate its effectiveness, we present a case study of a lamellar phase characterized by distinct peaks in its small-angle neutron scattering intensities.

central moment expansions↗