Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Augmentation of MS/MS Libraries with Spectral Interpolation for Improved Identification

Tandem mass spectrometry (MS/MS) is a primary tool for identification of small molecules and metabolites where resultant spectra are most commonly identified by matching them with spectra in MS/MS reference libraries. The high degree of variability in MS/MS spectrum acquisition techniques and parameters creates a significant challenge for building standardized reference libraries. Here we present a method to improve the usefulness of existing MS/MS libraries by augmenting available experimental spectra datasets with statistically interpolated spectra at unreported collision energies. We find that highly accurate spectral approximations can be interpolated from as few as three experimental spectra and that the interpolated spectra will be consistent with true spectra gathered from the same instrument as the experimental spectra. Supplementing existing spectral databases with interpolated spectra yields consistent improvements to identification accuracy on a range of instruments and precursor types. Applying this method yields significant improvements (~10% more spectra correctly identified) on large datasets (2,000 - 10,000 spectra), indicating this is a quick yet adept tool for improving spectral matching in situations where available reference libraries are not yet sufficient. We also find improvements of matching spectra across instrument types (between an Agilent Q-TOF and an Orbitrap Elite), at high collision energies (50 - 90 eV), and with smaller datasets available through MassBank.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating the Gas-Phase Behavior of Nitazene Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

2-benzylbenzimidazoles, or “nitazenes”, are a class of novel synthetic opioids (NSOs) that are increasingly being detected alongside fentanyl analogs and other opioids in drug overdose cases. Nitazenes can be 20x more potent than fentanyl but are not routinely tested for during postmortem or clinical toxicology drug screens; thus, their prevalence in drug overdose cases may be under-reported. Traditional analytical workflows utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS) often require additional confirmation with authentic reference standards to identify a novel nitazene. However, additional analytical measurements with ion mobility spectrometry (IMS) may provide a path towards reference-free identification, which would greatly accelerate NSO identification rates in toxicology labs. Presented here are the first IMS and collision cross section (CCS) measurements on a set of fourteen nitazene analogs using a Structures for Lossless Ion Manipulations (SLIM)-Orbitrap MS. All nitazenes exhibited two high intensity baseline-separated IMS distributions, which fentanyls and other drug and drug-like compounds also exhibit. Incorporating water into the electrospray ionization (ESI) solution caused the intensities of the higher mobility IMS distributions to increase the intensities of the lower mobility IMS distributions to decrease. Nitazenes lacking a nitro group at the R1 position exhibited the greatest shifts in signal intensities due to water. Furthermore, IMS-MS/MS experiments showed that the higher mobility IMS distributions of all nitazenes produced fragment ions with m/z 72, 100, and other low intensity fragments while the lower mobility IMS distributions only produced fragment ions with m/z 72 and 100. The IMS, solvent, and fragmentation studies provide experimental evidence that nitazenes potentially exhibit three gas-phase protomers. In conclusion, the cyclic IMS capability of SLIM was also employed to partially resolve four sets of structurally similar nitazene isomers (e.g., protonitazene/isotonitazene, butonitazene/isobutonitazene/secbutonitazene), showcasing the potential of using high-resolution IMS separations in MS-based workflows for reference-free identification of emerging nitazenes and other NSOs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crop emergence date determination from spectral data

Estimating the emergence of a given crop, such as wheat or barley, is proposed using an analytic method which relies on the hypothesis that in the region (lambda = 0.70-1.35 microns) a given crop, after emergence, has a unique spectral profile in time. If the crop emerges early or late, relative to a reference standard determined for a given segment, the profile is displaced but has the same shape. Therefore, given the crop specific constants of the reference profile and a sufficient number of Landsat observations of reflectivity at specific times, the emergence date of a field can be determined.

Badhwar, G. D.↗

The Calibration of the DSCOVR EPIC Multiple Visible Channel Instrument Using MODIS and VIIRS as a Reference

The Deep Space Climate Observatory (DSCOVR), launched on 11 February 2015, is a satellite positioned near the Lagrange-1 (L1) point, carrying several instruments that monitor space weather, and Earth-view sensors designed for climate studies. The Earth Polychromatic Imaging Camera (EPIC) onboard DSCOVR continuously views the sun-illuminated portion of the Earth with spectral coverage in the UV, VIS, and NIR bands. Although the EPIC instrument does not have any onboard calibration abilities, its constant view of the sunlit Earth disk provides a unique opportunity for simultaneous viewing with several other satellite instruments. This arrangement allows the EPIC sensor to be inter-calibrated using other well-characterized satellite instrument reference standards. Two such instruments with onboard calibration are MODIS, flown on Aqua and Terra, and VIIRS, onboard Suomi-NPP. The MODIS and VIIRS reference calibrations will be transferred to the EPIC instrument using both all-sky ocean and deep convective clouds (DCC) ray-matched EPIC and MODIS/VIIRS radiance pairs. An automated navigation correction routine was developed to more accurately align the EPIC and MODIS/VIIRS granules. The automated navigation correction routine dramatically reduced the uncertainty of the resulting calibration gain based on the EPIC and MODIS/VIIRS radiance pairs. The SCIAMACHY-based spectral band adjustment factors (SBAF) applied to the MODIS/ VIIRS radiances were found to successfully adjust the reference radiances to the spectral response of the specific EPIC channel for over-lapping spectral channels. The SBAF was also found to be effective for the non-overlapping EPIC channel 10. Lastly, both ray-matching techniques found no discernable trends for EPIC channel 7 over the year of publically released EPIC data.

Haney, Conor↗

Depth profiling and standardization from the back side of a sample for accurate analyses: Emphasis on quantifying low‐fluence, shallow implants in diamond‐like carbon

Rationale Back‐side thinning of wafers is used to eliminate issues with transient sputtering when analyzing near‐surface element distributions. Precise and accurate calibrated implants are created by including a standard reference material during the implantation. Combining these methods allows accurate analysis of low‐fluence, shallow features even if matrix effects are a concern. Methods Implanted Na (<2.0 × 10 11 ions/cm 2 , peaking <50 nm) in diamond‐like carbon (DLC) film on silicon (solar wind returned by NASA's Genesis mission) was prepared for measurement as follows. Implanted surfaces of samples were epoxied to wafers and back‐side‐thinned using physical or chemical methods. Thinned samples were then implanted with reference ions for accurate quantification of the solar wind implant. Analyses used a CAMECA IMS 7f‐GEO SIMS in depth‐profiling mode. Results Back‐side‐implanted reference ions reduced the need to change sample mounts or stage position and could be spatially separated from the solar wind implant even when measuring monoisotopic ions. Matrix effects in DLC were mitigated and the need to find an identical piece of DLC for a reference implant was eliminated. Accuracy was only limited by the back‐side technique itself. Conclusions Combining back‐side depth profiling with back‐side‐implanted internal standards aides quantification of shallow mono‐ and polyisotopic implants. This technique helps mitigate matrix effects and keeps measurement conditions consistent. Depth profile acquisition times are longer, but if sample matrices are homogeneous, procedural changes can decrease measurement times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The effect of sample holder material on ion mobility spectrometry reproducibility

When a positive detection of a narcotic occurs during the search of a vessel, a decision has to be made whether further intensive search is warranted. This decision is based in part on the results of a second sample collected from the same area. Therefore, the reproducibility of both sampling and instrumental analysis is critical in terms of justifying an in depth search. As reported at the 2nd Annual IMS Conference in Quebec City, the U.S. Coast Guard has determined that when paper is utilized as the sample desorption medium for the Barringer IONSCAN, the analytical results using standard reference samples are reproducible. A study was conducted utilizing papers of varying pore sizes and comparing their performance as a desorption material relative to the standard Barringer 50 micron Teflon. Nominal pore sizes ranged from 30 microns down to 2 microns. Results indicate that there is some peak instability in the first two to three windows during the analysis. The severity of the instability was observed to increase as the pore size of the paper is decreased. However, the observed peak instability does not create a situation that results in a decreased reliability or reproducibility in the analytical result.

Jadamec, J. Richard↗

Preparation of large-particle-size monodisperse latexes in space

Results are reported of latex sphere polymerization experiments performed on two flights of the Columbia and three flights of the Challenger. The trials were carried out because polymerization of the spheres in space avoids coagulation, nucleation of a new crop of particles, and excessive stirring requirements, and allows growth of spheres larger than 4 microns diam. The Monodisperse Latex Reactor (MLR) held four stirred 100 cc sealed stainless steel cylindrical containers. The mixtures were monitored for the conversion times, volume decreases as spheres formed and the mixture temperature. The spheres were grown from 0.19 micron seeds. Details of the flight preparation efforts are outlined. In flights which did not experience mechanical malfunctions spheres 3-30 microns diam were grown that had noticeably lower size variations than did the ground-based control particles. The 10 micron diam spheres grown on STS-6 were accepted as standard reference material by the NBS and became the first products made in space to be commercially sold on earth; the 30 micron spheres also became NBS standards. The experiments confirmed all projected benefits of producing the spheres in space, as well as provided the opportunity to grow more larger offsize spheres by finishing the growths on earth.

Vanderhoff, J. W.↗

Rotating pressure measurement system using an on board calibration standard

A computer-controlled multichannel pressure measurement system was developed to acquire detailed flow field measurements on board the Large Low Speed Centrifugal Compressor Research Facility at the NASA Lewis Research Center. A pneumatic slip ring seal assembly is used to transfer calibration pressures to a reference standard transducer on board the compressor rotor in order to measure very low differential pressures with the high accuracy required. A unique data acquisition system was designed and built to convert the analog signal from the reference transducer to the variable frequency required by the multichannel pressure measurement system and also to provide an output for temperature control of the reference transducer. The system also monitors changes in test cell barometric pressure and rotating seal leakage and provides an on screen warning to the operator if limits are exceeded. The methods used for the selection and testing of the the reference transducer are discussed, and the data acquisition system hardware and software design are described. The calculated and experimental data for the system measurement accuracy are also presented.

Senyitko, Richard G.↗

Understanding the structural and morphological effects of synthesis route on NpO 2

The availability of actinide standard materials for use in nuclear safeguard applications is critical, as is thorough characterization thereof. Although accurate trace element compositions and isotopic considerations are paramount for deployment of reference standards, structural characterization is also essential towards accurately describing the chemical form and potential matrix effects in candidate materials. Here, to this end, samples of NpO 2 were synthesized via a direct denitration (DD) method and probed with powder X-ray diffraction (PXRD), Raman spectroscopy, and scanning electron microscopy (SEM) for structural and morphological characterization and comparison with NpO 2 materials produced via modified direct denitration (MDD). PXRD confirmed the bulk identity of NpO 2 , and no additional phases were identified using this method. Analysis of Raman data collected using a 532 nm excitation wavelength indicates that samples are mostly phase pure; however, some variability in spectral features is observed. Analysis of additional spectroscopic data collected with a 785 nm excitation wavelength revealed variability in the relative intensity of spectral features. Raman spectroscopy indicates that the sample is primarily NpO 2 ; however, additional signals indicate possible structural disorder, oxidized species, or potential contributions from other Np phases. To further investigate the possibility of additional phase contributions within the sample of NpO 2 , Raman spectroscopic mapping was employed to examine the homogeneity of the sample produced via DD. From this analysis, we determined that despite variability in the intensity of Raman-active vibrational modes, consistent spectra are obtained throughout the area of the sample investigated. SEM images show aggregates with variable sizes and shapes, with rounded, primary particles possessing an average diameter of approximately 100 nm. Comparison of the results of these multimodal analyses to the literature indicates that the crystal chemical, spectroscopic, and microstructural properties of NpO 2 vary based on synthesis method, even if X-ray diffraction data indicate that the bulk phase is NpO 2 .

Direct denitration↗

Results of the 1981 NASA/JPL balloon flight solar cell calibration program

The calibration of the direct conversion of solar energy through use of solar cells at high altitudes by balloon flight is reported. Twenty seven modules were carried to an altitude of 35.4 kilometers. Silicon cells are stable for long periods of time and can be used as standards. It is demonstrated that the cell mounting cavity may be either black or white with equal validity in setting solar simulators. The calibrated cells can be used as reference standards in simulator testing of cells and arrays.

Seaman, C. H.↗

Thermodynamic Data For 50 Chemical Elements

Report presents data on thermo-dynamic properties of 50 chemical elements, isotope (deuterium) of one of elements, and electron gas, all in standard reference states. Data tabulated as functions of temperature; also given in form of least-squares-fit coefficients of two functional forms for heat capacities at constant pressure in standard states, with constants of integration for enthalpy and entropy.

Mcbride, Bonnie J.↗

Lunar Regolith Simulant Materials: Recommendations for Standardization, Production, and Usage

Experience gained during the Apollo program demonstrated the need for extensive testing of surface systems in relevant environments, including regolith materials similar to those encountered on the lunar surface. As NASA embarks on a return to the Moon, it is clear that the current lunar sample inventory is not only insufficient to support lunar surface technology and system development, but its scientific value is too great to be consumed by destructive studies. Every effort must be made to utilize standard simulant materials, which will allow developers to reduce the cost, development, and operational risks to surface systems. The Lunar Regolith Simulant Materials Workshop held in Huntsville, AL, on January 24 26, 2005, identified the need for widely accepted standard reference lunar simulant materials to perform research and development of technologies required for lunar operations. The workshop also established a need for a common, traceable, and repeatable process regarding the standardization, characterization, and distribution of lunar simulants. This document presents recommendations for the standardization, production and usage of lunar regolith simulant materials.

Sibille, L.↗

Verification of technical elements of the advanced spacecraft based upon the CCSDS recommendation

We are going to meet the era when advanced spacecraft such as space stations are developed and operated. The current system of the satellite operations control will need to undergo many changes. We consider that the future system will require the following functions: the function for interchanging data between international agencies, processing the various kinds of space data, and distributing data as many unspecified users require. However, we have to solve the following problems in order to satisfy these requirements: the problem of standardization of space data communication protocol, establishment of multimedia data management method, and standardization of the user interface. This paper describes three techniques to solve the above mentioned problems. That is, standardization of the data communication protocol between space and ground by AOS (Advanced Orbiting System) protocol of CCSDS (Consultative Committee for Space Data Systems) Recommendation, management of multimedia data by catalog reference, standardization of user interface by SFDU(Standard Formatted Data Unit) of CCSDS Recommendation.

Hara, Hideo↗

Controlled-Shape, Ultrasonic-Angle-Beam Standard Reflector

New ultrasonic angle-beam standard reflector uses impression of letter "l" steel-die stamp. NDE techniques and standard reflector apply to use of pulse-echo-type ultrasonic equipment for inspection of wrought metals including forgings and forging stock; rolled billet, bar or plate; and extruded bar, tube, and shapes. "l" reference standard reflector affords advantages of easy insertion in inspected item using common hand-tools and greatly reduced implementation time through elimination of machining operations.

Berry, J., Robertf.↗

Development of a Reference Model for Molten-Salt-Cooled Pebble-Bed Reactor Using SAM

To support the development and utilization of the SAM code for fluoride-salt-cooled high-temperature pebble-bed reactor (PB-FHR) safety analysis and licensing, an effort was devoted to developing reference models for PB-FHR primary loop and the reactor cavity cooling system (RCCS). A reference standard problem of a prototypical reactor design is foundational to NRC and industry to verify the adequacy of computer codes and evaluation models for a specific reactor type. The SAM code was enhanced for the reference PB-FHR model development, including a 1D-3D flow coupling scheme and conjugate heat transfer between porous media and solid structures. The reference FHR primary loop model was developed based on the UC Berkeley Mk1 FHR design with additional design features from the Kairos Power’s KP-FHR core. The PB-FHR core is modeled by a two-dimensional porous medium while the rest of the primary loop is represented by a SAM one-dimensional model. A SAM one-dimensional primary loop model was also developed for comparison using a single channel approach for the reactor core. Furthermore, the water-based NSTF cavity was modeled using SAM multi-dimensional flow module, to assist in evaluating SAM capabilities of modeling the emergency heat removal systems relying on RCCS concepts.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A small-volume, high-throughput approach for surface tension and viscosity measurements of liquid fuels

An ongoing effort looking at bioblendstocks to function as drop-in replacements or blending components for gasoline has identified a large number of candidate fuels. This work documents an approach for rapid screening of candidate fuels using relatively small sample sizes ($\mathcal{O}(\mu\,{\rm l})$) that targets two key physical properties of liquid fuels—surface tension and viscosity. The approach utilizes shape oscillation dynamics of single droplets generated by a piezo-electric device and their decay over time. Strobed imaging of the oscillation process is used along with image processing, edge detection, and data analysis to capture the decay of the oscillation over time. The time constant of the decay process along with oscillation frequency are then used to estimate viscosity and surface tension using a theory for small amplitude droplet oscillations. Measurements are obtained for primary reference fuels (isooctane and n-heptane) as well as candidate fuels from four bio-derived functional groups of interest. Measurement results for surface tension and viscosity are correlated with literature data as well as measurements from standard reference instruments. The measurement results show that the droplet oscillation based approach is capable of reproducing surface tension and viscosity values for the tested fuels within deviations of 7% and 13% respectively from literature data. Results are obtained using an average of 5 µl per fuel within about 20 s, thus demonstrating a small-volume, high-throughput approach that can be used for screening of candidate bioblendstock fuels.

09 BIOMASS FUELS↗

Performance comparison of Malvern instruments laser diffraction drop size analyzer

The performance of ten laser diffraction particle sizing instruments (Malvern models 2200 and 2600) has been evaluated using a synthetic particle size reference standard in a round-robin test at nine independent laboratories. A calibration reticle consisting of a two-dimensional array of opaque, circular particle images photoetched in chrome thin film deposited on a glass substrate was used as the reference. Mean diameters (e.g., D32) for the reticle measured by the ten unmodified instruments varied by 27 percent. In contrast, data from six instruments with individually calibrated photodetector correction factors demonstrated much better agreement and were within 2.6 percent of the actual reticle properties.

Hirleman, E. D.↗

Numeric data distribution: The vital role of data exchange in today's world

The major aim of the NIST standard Reference Data Program (SRD) is to provide critically evaluated numeric data to the scientific and technical community in a convenient and accessible form. A second aim of the program is to provide feedback into the experimental and theoretical programs to help raise the general standards of measurement. By communicating the experience gained in evaluating the world output of data in the physical sciences, NIST/SRD helps to advance the level of experimental techniques and improve the reliability of physical measurements.

Chase, Malcolm W.↗