Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLE PREPARATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High throughput, spatially resolved thermal properties measurement using attachable and reusable 3ω sensors

The 3ω method is a well-established thermal technique used to measure the thermal conductivity of materials and the thermal resistance of interfaces. It has significant advantages over other steady state and transient thermal techniques in its ability to provide spatially resolved thermal property measurements over a wide range of thermal conductivity. Despite its advantages, it has been restricted to lab-scale use because of the difficulty involved in sample preparation and sensor fabrication and is limited to non-metallic substrates. High-throughput 3ω measurements with reusable sensors have not been realized yet. In this work, we demonstrate a method of applying reusable 3ω sensors fabricated on flexible polyimide films to measure bulk and spatially resolved thermal properties. Here, we establish the limits of thermal conductivity measurement with the method to be 1 to 200 W/mK, and within the measurement limit, we verify the method by comparing the measured thermal conductivities of standard samples with established values. From the 3ω measurements, we also determine the thermal resistance of an interlayer of thermal grease as a function of pressure and compare it against the resistance calculated from direct thickness measurements to demonstrate the ability of this method to provide spatially resolved subsurface information. The technique presented is general and applicable to both metallic and non-metallic substrates, providing a method for high-throughput 3ω measurements with reusable sensors and without considerable sample preparation.

47 OTHER INSTRUMENTATION↗

Machine learning enables reconstruction of past fire regimes from charcoal-derived fire intensity and fuel composition

Background Fire is a foundational ecological process that shapes ecosystem structure, diversity, and resilience. Quantifying paleofire regime attributes such as frequency, severity, and intensity is essential for understanding the historical range of variability in fire behavior and its ecological effects. While frequency and severity are often reconstructed in paleofire studies, quantitative reconstructions of fire intensity remain limited. Recent work has shown that maximum pyrolysis temperature—a proxy for fire intensity—and plant species type can be inferred from charcoal using transmission Fourier-transform infrared (FTIR) spectroscopy. However, the sample preparation for transmission FTIR is destructive and time-consuming, limiting application and reuse of materials for other analyses. We evaluated reflectance FTIR spectroscopy as a non-destructive alternative for reconstructing combustion temperature and plant species from laboratory-generated charcoal. We also examined the influence of contrasting airflow environments (ambient air versus nitrogen-rich) on pyrolysis temperature and plant species reconstruction prediction accuracies and compared predictive performance between a novel, neural network–based deep learning model with the traditional modern analogue technique (MAT) using k-nearest neighbor functions. As proof of concept, we apply our enhanced methodology to ancient charcoal to demonstrate applicability at improving long-term fire regime reconstructions and the ability to link paleofire records with contemporary fire ecology. Results Our analysis shows that transmission and reflectance FTIR spectra yield comparable spectral profiles. However, sample preparation for reflectance FTIR is minimal and non-destructive, unlike transmission FTIR which is destructive. We demonstrate that oxygen environments improved reconstruction accuracy relative to nitrogen-rich conditions. Finally, our deep learning neural network (DL) achieved testing accuracies of 98.7% for temperature and 96.2% for species identification, outperforming MAT’s k-NN approach (89.8% and 65.9%, respectively). A Shapley importance analysis identified 5 key spectral regions that greatly influenced the model’s temperature or species categorization. When applied to ancient charcoal, our results show historic fires from the most recent past primarily burned at low intensities (400–500 °C), reflective of natural fire regimes in ponderosa pine forests. Our results corroborate charcoal morphology data that suggests all ancient charcoal originated from burned woody plant types. Conclusions By combining reflectance FTIR spectroscopy with a deep learning approach, we provide the first accuracies high enough to confidently identify both species and temperature from laboratory-produced charcoal, improving quantitative reconstructions of fire intensity and fuel composition from paleofire records. This opens a wide range of research into the link between fire and larger drivers (i.e., climate or human) and greater ecological understanding of fire regimes beyond that of burn scars or recent observations. These methodological improvements have direct relevance for fire management by improving interpretation of historical fire behavior, informing fuel–fire relationships, and providing a scalable analytical framework applicable to both long-term ecological studies and contemporary fire science.

54 ENVIRONMENTAL SCIENCES↗

Application of a headspace GC–MS method to evaluate the product quality of alcohol‐based hand wipe sanitizers

Abstract The investigation of marketed hand wipe sanitizers presented an analytical challenge owing to the need for extraction from the solid matrix of the products. The present work describes the development of a new sample preparation method for the extraction of analytes from the hand wipe sanitizer matrix into dimethyl sulfoxide for analysis using headspace GCMS. Alcohol‐based hand sanitizer (ABHS) wipe products labeled to contain ethanol or isopropanol as active ingredients were tested, varying in the size and weight of the wipes. The spike recovery assay was confirmed using spiking solutions containing impurities at concentrations equivalent to 50, 100 and 200% of the interim concentration limits. All of the tested analytes showed recovery within the allowable limits (80–120%). Six marketed ABHS wipe products were tested and no impurities above the FDA interim limits were observed. One product contained ethanol below the 60% v/v limit and another product was mislabeled for isopropanol and was found to contain ethanol instead. Four of the six ABHS products did not meet the label claim, which may affect the product quality. The analytical method and sample preparation procedures will provide the FDA and ABHS manufacturers with the capability to conduct quality assurance testing of hand wipe sanitizers for active ingredient content and impurities.

Biochemistry & Molecular Biology↗

Workflow for High-throughput Screening of Enzyme Mutant Libraries Using Matrix-assisted Laser Desorption/Ionization Mass Spectrometry Analysis of Escherichia coli Colonies

High-throughput molecular screening of microbial colonies and DNA libraries are critical procedures that enable applications such as directed evolution, functional genomics, microbial identification, and creation of engineered microbial strains to produce high-value molecules. A promising chemical screening approach is the measurement of products directly from microbial colonies via optically guided matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Measuring the compounds from microbial colonies bypasses liquid culture with a screen that takes approximately 5 s per sample. We describe a protocol combining a dedicated informatics pipeline and sample preparation method that can prepare up to 3,000 colonies in under 3 h. The screening protocol starts from colonies grown on Petri dishes and then transferred onto MALDI plates via imprinting. The target plate with the colonies is imaged by a flatbed scanner and the colonies are located via custom software. The target plate is coated with MALDI matrix, MALDI-MS analyzes the colony locations, and data analysis enables the determination of colonies with the desired biochemical properties. This workflow screens thousands of colonies per day without requiring additional automation. The wide chemical coverage and the high sensitivity of MALDI-MS enable diverse screening projects such as modifying enzymes and functional genomics surveys of gene activation/inhibition libraries.

Choe, Kisurb↗

Data and scripts associated with a manuscript investigating impacts of solid phase extraction on freshwater organic matter optical signatures and mass spectrometry pairing

This data package is associated with the publication “Investigating the impacts of solid phase extraction on dissolved organic matter optical signatures and the pairing with high-resolution mass spectrometry data in a freshwater system” submitted to “Limnology and Oceanography: Methods.” This data is an extension of the River Corridor and Watershed Biogeochemistry SFA’s Spatial Study 2021 (https://doi.org/10.15485/1898914). Other associated data and field metadata can be found at the link provided. The goal of this manuscript is to assess the impact of solid phase extraction (SPE) on the ability to pair ultra-high resolution mass spectrometry data collected from SPE extracts with optical properties collected on ambient stream samples. Forty-seven samples collected from within the Yakima River Basin, Washington were analyzed dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC), absorbance, and fluorescence. Samples were subsequently concentrated with SPE and reanalyzed for each measurement. The extraction efficiency for the DOC and common optical indices were calculated. In addition, SPE samples were subject to ultra-high resolution mass spectrometry and compared with the ambient and SPE generated optical data. Finally, in addition to this cross-platform inter-comparison, we further performed and intra-comparison among the high-resolution mass spectrometry data to determine the impact of sample preparation on the interpretability of results. Here, the SPE samples were prepared at 40 milligrams per liter (mg/L) based on the known DOC extraction efficiency of the samples (ranging from ~30 to ~75%) compared to the common practice of assuming the DOC extraction efficiency of freshwater samples at 60%. This data package folder consists of one main data folder with one subfolder (Data_Input). The main data folder contains (1) readme; (2) data dictionary (dd); (3) file-level metadata (flmd); (4) final data summary output from processing script; and (5) the processing script. The R-markdown processing script (SPE_Manuscript_Rmarkdown_Data_Package.rmd) contains all code needed to reproduce manuscript statistics and figures (with the exception of that stated below). The Data_Input folder has two subfolders: (1) FTICR and (2) Optics. Additionally, the Data_Input folder contains dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data (SPS_NPOC_Summary.csv) and relevant supporting Solid Phase Extraction Volume information (SPS_SPE_Volumes.csv). Methods information for the optical and FTICR data is embedded in the header rows of SPS_EEMs_Methods.csv and SPS_FTICR_Methods.csv, respectively. In addition, the data dictionary (SPS_SPE_dd.csv), file level metadata (SPS_SPE_flmd.csv), and methods codes (SPS_SPE_Methods_codes.csv) are provided. The FTICR subfolder contains all raw FTICR data as well as instructions for processing. In addition, post processed FTICR molecular information (Processed_FTICRMS_Mol.csv) and sample data (Processed_FTICRMS_Data.csv) is provided that can be directly read into R with the associated R-markdown file. The Optics subfolder contains all Absorbance and Fluorescence Spectra. Fluorescence spectra have been blank corrected, inner filter corrected, and undergone scatter removal. In addition, this folder contains Matlab code used to make a portion of Figure 1 within the manuscript, derive various spectral parameters used within the manuscript, and used for parallel factor analysis (PARAFAC) modeling. Spectral indices (SPS_SpectralIndices.csv) and PARAFAC outputs (SPS_PARAFAC_Model_Loadings.csv and SPS_PARAFAC_Sample_Scores.csv) are directly read into the associated R-markdown file. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected some of these data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Influence of ion-pairing reagents on the separation of intact glycoproteins using hydrophilic-interaction liquid chromatography - high-resolution mass spectrometry

Hydrophilic-interaction liquid chromatography (HILIC) of intact proteins offers high-resolution separations of glycoforms of glycoproteins differing in the number of (neutral) glycans. However, to obtain efficient separations it is essential that the positively charged sites of the proteins are shielded by acidic (negative) ion-pair reagents (IPRs), so as to enhance the contribution of the hydroxyl groups of the (neutral) sugars in the glycoprotein. Here, we studied the influence of various IPRs that differ in physico-chemical properties, such as hydrophobicity and acidity, on the capillary-scale HILIC separation of intact (glyco)proteins. We evaluated the use of fluoroacetic acid (MFA), difluoroacetic acid (DFA), trifluoroacetic acid (TFA), and heptafluorobutyric acid (HFBA) as diluents for sample preparation, as solvents for sample loading on a reversed-phase trap prior to the HILIC separation, and as mobile-phase components for HILIC and HILIC-MS. To reduce the contribution of ion-exchange interaction with the (silica-based) stationary phase, we used an acrylamide-based monolithic column. We studied the influence of the different IPRs on each step of the separation of a mixture of proteins of different size and hydrophilicity and on the separation of the five glycoforms of ribonuclease B. The content of IPR in the sample was shown not to affect the separation and the MS detection. However, a low content of TFA and DFA in the mobile phase is favourable, as it reduces adduct formation and leads to higher signal intensity. The optimized HILIC conditions successfully resolved nine major glycoforms groups of a ~40 kDa glycoprotein horseradish peroxidase (HRP), as an example of a complex glycoprotein.

59 BASIC BIOLOGICAL SCIENCES↗

Understanding In-Situ Structure and Chemistry at Battery Interfaces Through Time-Resolved Cryo-EM

Transmission and scanning transmission electron microscopy are vital tools for characterizing interfacial structure and chemistry at high spatial resolutions but are limited by the fact that many materials are quickly damaged by electron beam irradiation. This is a challenge particularly for materials relevant to energy applications, such as lithium-containing battery materials, organic-inorganic hybrids, and liquid electrolytes. Cryogenic electron microscopy (cryo-EM) offers a partial solution to this issue by stabilizing beam-sensitive solid-solid or solid-liquid interfaces for characterization, but typical cryo-EM sample preparations are ex situ and thus cannot capture interfaces in their electrified state of interest to applications. Here, we present a method to prepare cryo-EM samples of electrified battery interfaces in situ to preserve the time-resolved structures and chemistry that arise under applied current or bias.

batteries↗

Plastic Scintillators via Rapid Photoinitiated Cationic Polymerization of Vinyltoluene

Cationic photopolymerization is applied for the rapid curing of a vinyltoluene and fluorophore solution into an efficient plastic scintillator. A hard solid is obtained via UV light-initiated polymerization of vinyltoluene, diaryliodonium salt, 9,9-dimethyl-2-phenylfluorene (PhF), and 9,9-dimethyl-2,7-distyrlfluorene (SFS) at ambient conditions with high conversion rates under a range of cationic photoinitiator concentrations, fluorophore concentrations, and light intensities. Insight into photopolymerization kinetics via photo differential scanning calorimetry (photoDSC) revealed photocuring time scales similar to those achieved in a commercial 3D printing resin. Furthermore, scintillator samples prepared cationically performed well compared to samples of equivalent compositions prepared by a lengthy thermally initiated radical polymerization.

36 MATERIALS SCIENCE↗

Apollo Next Generation Sample Analysis (ANGSA): an Apollo Participating Scientist Program to Prepare the Lunar Sample Community for Artemis

As a first step in preparing for the return of samples from the Moon by the Artemis Program, NASA initiated the Apollo Next Generation Sample Analysis Program (ANGSA). ANGSA was designed to function as a low-cost sample return mission and involved the curation and analysis of samples previously returned by the Apollo 17 mission that remained unopened or stored under unique conditions for 50 years. These samples include the lower portion of a double drive tube previously sealed on the lunar surface, the upper portion of that drive tube that had remained unopened, and a variety of Apollo 17 samples that had remained stored at -27 °C for approximately 50 years. ANGSA constitutes the first preliminary examination phase of a lunar “sample return mission” in over 50 years. It also mimics that same phase of an Artemis surface exploration mission, its design included placing samples within the context of local and regional geology through new orbital observations collected since Apollo and additional new “boots-on-the-ground” observations, data synthesis, and interpretations provided by Apollo 17 astronaut Harrison Schmitt. ANGSA used new curation techniques to prepare, document, and allocate these new lunar samples, developed new tools to open and extract gases from their containers, and applied new analytical instrumentation previously unavailable during the Apollo Program to reveal new information about these samples. Most of the 90 scientists, engineers, and curators involved in this mission were not alive during the Apollo Program, and it had been 30 years since the last Apollo core sample was processed in the Apollo curation facility at NASA JSC. There are many firsts associated with ANGSA that have direct relevance to Artemis. ANGSA is the first to open a core sample previously sealed on the surface of the Moon, the first to extract and analyze lunar gases collected in situ, the first to examine a core that penetrated a lunar landslide deposit, and the first to process pristine Apollo samples in a glovebox at -20 °C. All the ANGSA activities have helped to prepare the Artemis generation for what is to come. The timing of this program, the composition of the team, and the preservation of unopened Apollo samples facilitated this generational handoff from Apollo to Artemis that sets up Artemis and the lunar sample science community for additional successes.

79 ASTRONOMY AND ASTROPHYSICS↗

Destructive Analysis of TRISO Particles: Crush/Burn/Leach Followed by Davies-Gray Titration and IDMS

The accurate accounting of nuclear materials is a cornerstone of international nuclear safeguards. One emerging challenge in this domain is the fabrication of TRIstructural ISOtropic (TRISO) particle fuels. Although these innovative fuel forms are critical for advanced reactor applications, their robust refractory ceramics and coating compositions present significant obstacles to destructive analysis (DA) methods. Ensuring full and quantitative recovery from these particles is essential for accurate mass accountancy. The current study was initiated to address these challenges, first by validating a previously established destructive method developed by Oak Ridge National Laboratory (ORNL) for the quantitative recovery of uranium from TRISO particles and then following that process with uranium content determination through isotope dilution mass spectrometry (IDMS) and Davies-Gray titration. This study expands on the scope of a digestive method that was developed under the Advanced Gas Reactor Fuel Development and Qualification program and is currently implemented in both the Coated Particle Fuel Development Laboratory and Irradiated Fuels Examination Laboratory at ORNL. The success of the previous Advanced Gas Reactor work relied on developing a DA method to evaluate the fabrication process and reactor experiments. The methodology described in this report was designed to rigorously investigate the efficacy of the crush/burn/leach sample preparation of TRISO particles; it aims to quantify uranium recovery while also assessing the effects of TRISO constituents (e.g., silicon and zirconium) on analytical precision and accuracy. By comparing the results from the titration method and IDMS, we sought to determine whether existing analytical procedures accepted by the International Atomic Energy Agency (IAEA) could be effectively translated to TRISO fuel forms. The team employed an approach that involved processing replicate TRISO samples, optimizing the milling (i.e., crushing) step and performing serial leaches. The elemental composition of the analytical samples was examined to prepare for interference studies in the second year of this project. The integration of gamma spectrometry to verify residual uranium activity further strengthened the validation. Statistical methods were applied to the collected data to evaluate the uncertainties arising from sampling, sample preparation and uranium quantification. These uncertainties were then compared to the IAEA’s international target values (ITVs). Additional data collected in upcoming project work will strengthen the uncertainty estimates. Ultimately, it is hoped that this project will contribute materially to the body of work related to characterization of TRISO based fuels for the purpose of material accountancy and its applications to international safeguards.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preparing for successful protein crystallization experiments

Crystal-based structural methods, including X-ray crystallography, are frequently utilized for the determination of high-resolution structures of biomolecules. All crystal-based diffraction methods first require the preparation of biomolecular crystals, and careful sample preparation for crystallization experiments can increase the frequency of success. In this article, strategies to optimize factors that can impact crystallization are presented, from which buffers and reducing agents are most favorable to which crystallization techniques could be used.

36 MATERIALS SCIENCE↗

Toward Automated Plasma Focus Ion Beam Instrument Calibration for Materials Processing [Poster]

To accelerate the transition to autonomous focused ion beam (FIB) microscopy, we require an objective figure of merit (FOM) for assessing calibration. For our purposes, these FOMs related to beam astigmatism, quad, and focus. Intelligent calibration integrated into scripted workflows will enable fully automated sample preparation workflows that produce higher quality samples with less operator time.

97 MATHEMATICS AND COMPUTING↗

Tailoring the Magnetic and Hyperthermic Properties of Biphase Iron Oxide Nanocubes through Post-Annealing

Tailoring the magnetic properties of iron oxide nanosystems is essential to expanding their biomedical applications. In this study, 34 nm iron oxide nanocubes with two phases consisting of Fe3O4 and α-Fe2O3 were annealed for 2 h in the presence of O2, N2, He, and Ar to tune the respective phase volume fractions and control their magnetic properties. X-ray diffraction and magnetic measurements were carried out post-treatment to evaluate changes in the treated samples compared to the as-prepared samples, showing an enhancement of the α-Fe2O3 phase in the samples annealed with O2 while the others indicated a Fe3O4 enhancement. Furthermore, the latter samples indicated enhancements in crystallinity and saturation magnetization, while coercivity enhancements were the most significant in samples annealed with O2, resulting in the highest specific absorption rates (of up to 1000 W/g) in all the applied fields of 800, 600, and 400 Oe in agar during magnetic hyperthermia measurements. The general enhancement of the specific absorption rate post-annealing underscores the importance of the annealing atmosphere in the enhancement of the magnetic and structural properties of nanostructures.

Crystallography↗

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermoreflectance Detection of Point Defects Resulting from Focused Ion Beam Milling

Focused ion beam (FIB) milling is a commonly used tool for nanoscale material processing, such as for transmission electron microscopy (TEM) sample preparation, or the creation of fiducial markers prior to other processes and measurements. During milling, a high energy ion beam is used to remove material via sputtering. The expelled target material may return to the sample surface however, affecting subsequent measurements. Beam spreading or irradiation due to neutral gallium may also irradiate a larger area than intended. Extensive research has explored the effects of FIB milling on the prepared TEM sample, but few have looked at the effects of milling on the properties of the sample surrounding the milled region. We use multiple pump-probe laser-based techniques (time domain thermoreflectance and steady-state thermoreflectance) to measure the spatial extent of FIB-induced surface/subsurface changes on a series of silicon wafers milled at multiple currents and doses. We supplement these measurements with high-resolution scanning transmission electron microscopy, energy dispersive X-ray spectroscopy, stylus profilometry, and time-of-flight secondary ion mass spectroscopy. We find a sample surface affected by the FIB up to 1 mm from where milling occurred, with a notable dependence on the ion beam current. We also note remarkably high sensitivity to surface defects using the thermoreflectance metrologies, including detection where other measurements failed.

defects↗

Chapter 4.2 - Preparation of nanoparticles for surface analysis

A variety of methods used to prepare nano-objects for surface analysis are described along with information about when they might be best applied. Intrinsic properties of NPs that complicate their characterization and need to be considered when planning for surface or other analyses of NPs are identified, including challenges associated with reproducible synthesis and functionalization of the particles as well as their dynamic nature. Information about the sample preparation processes, along with analysis data, that need to be added to the collection of material provenance information is identified and examples of protocols that have been successfully used for preparation of nano-objects for surface analysis are included in an annex.

characterization challenges↗

Direct observation of twisted stacking domains in the van der Waals magnet CrI 3

Van der Waals (vdW) stacking is a powerful technique to achieve desired properties in condensed matter systems through layer-by-layer crystal engineering. A remarkable example is the control over the twist angle between artificially-stacked vdW crystals, enabling the realization of unconventional phenomena in moiré structures ranging from superconductivity to strongly correlated magnetism. Here, we report the appearance of unusual 120° twisted faults in vdW magnet CrI 3 crystals. In exfoliated samples, we observe vertical twisted domains with a thickness below 10 nm. The size and distribution of twisted domains strongly depend on the sample preparation methods, with as-synthesized unexfoliated samples showing tenfold thicker domains than exfoliated samples. Cooling induces changes in the relative populations among different twisting domains, rather than the previously assumed structural phase transition to the rhombohedral stacking. The stacking disorder induced by sample fabrication processes may explain the unresolved thickness-dependent magnetic coupling observed in CrI 3 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗