Search NASASearch

SEARCH · Search NASA

Results for “Scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Simultaneous observations of equatorial ionospheric scintillation on four frequencies

The variation with frequency of ionospheric scintillations, simultaneously observed at 40, 140, 360, and 860 MHz at equatorial latitudes, was studied. The ATS 6 geostationary satellite was equipped with radio beacons at 40, 140, and 360 MHz, and also with a television downlink at 860 MHz. The signals were recorded at Ootacamund, India (dip 4 deg N) and were most common between 2000 and 2300 LT. It was found that the spectral index of an expression used by Aarons et al (1967) was not constant but decreased with increasing magnitude of scintillations. For weak scintillations the spectral index (referred to as the exponent) was found to be close to 1.0. The analysis of the records involved scaling at 15-sec intervals and the calculation of the average scintillation index.

Rastogi, R. G.

Multifrequency equatorial ionospheric scintillations in American and Indian zones

Amplitude scintillations of 40/41, 140 and 360 MHz transmissions recorded at Huancayo (phase I) and at Ootacamund (phase II) of the ATS-6 program are compared. The scintillations were found to be strongest between 20 and 24 hr LT with another peak around midday. The daytime scintillations do not show a significant seasonal variation at either of these stations. The nighttime scintillations were maximum during December solstices at Huancayo and during equinoxes at Ootacamund and suggested to be due to non-q type of sporadic E following the occurrence of counter-electrojet.

Rastogi, R. G.

A synoptic study of Doppler scintillation transients in the solar wind

This paper conducts the first synoptic study of Doppler scintillation transients caused by interplanetary disturbances. The Doppler scintillation data used are part of the 2.3-GHz navigation data collected by the NASA Deep Space Network when tracking planetary spacecraft during 1979-1983, a period that includes solar maximum. A total of 148 separate transients covering a heliocentric distance range of 5-179 solar radii were detected, including 26 transients detected by more than one spacecraft. The frequency of occurrence was highest near the sun and decreased with radial distance, a reflection of the radial evolution of the transients and the sensitivity of the Doppler scintillation measurements to transients. Since transients can be disruptive, as was demonstrated during the encounter of Saturn by Pioneer 11 in 1979, information on Doppler scintillation transients is essential.

Woo, Richard

The Scintillating Optical Fiber Isotope Experiment

This paper describes the Scintillating Optical Fiber Isotope Experiment (SOFIE) which is being developed by Washington University and the University of New Hampshire to study the abundances of cosmic ray isotopes in the iron charge region. This detector system is a Cerenkov-Range-dE/dx experiment and utilizes range and trajectory detectors made of scintillating optical fibers, a fused silica Cerenkov counter, and plastic scintillator dE/dx counters to determine the charge and mass of cosmic ray nuclei. A brief description of the balloon flight instrument presently being developed will be given followed by initial results of an engineering model calibration at the LBL Bevalac heavy ion accelerator. In addition a brief discussion of the potential of scintillating fiber trajectory detectors for use in experiments requiring precise trajectory determination such as those being planned for the NASA Particle Astrophysics Magnet Facility (Astromag) program is presented.

Binns, W. Robert

Mitigation of Laser Beam Scintillation in Free-Space Optical Communication Systems Through Coherence-Reducing Optical Materials

Free-space optical communication systems (also known as lasercom systems) offer several performance advantages over traditional radio frequency communication systems. These advantages include increased data rates and reduced operating power and system weight. One serious limiting factor in a lasercom system is Optical turbulence in Earth's atmosphere. This turbulence breaks up the laser beam used to transmit the information into multiple segments that interfere with each other when the beam is focused onto the receiver. This interference pattern at the receiver changes with time causing fluctuations in the received optical intensity (scintillation). Scintillation leads to intermittent losses of the signal and an overall reduction in the lasercom system's performance. Since scintillation is a coherent effect, reducing the spatial and temporal coherence of the laser beam will reduce the scintillation. Transmitting a laser beam through certain materials is thought to reduce its coherence. Materials that were tested included: sapphire, BK7 glass, fused silica and others. The spatial and temporal coherence of the laser beam was determined by examining the interference patterns (fringes) it formed when interacting with various interferometers and etalons.

Renner, Christoffer J.

Dual-Frequency Observations of 140 Compact, Flat-Spectrum Active Galactic Nuclei for Scintillation-Induced Variability

The 4.9 GHz Micro-Arcsecond Scintillation-Induced Variability (MASIV) Survey detected a drop in Interstellar Scintillation (ISS) for sources at red shifts z > or approx. 2, indicating an apparent increase in angular diameter or a decrease in flux density of the most compact components of these sources, relative to their extended emission. This can result from intrinsic source size effects or scatter broadening in the Intergalactic Medium (IGM) , in excess of the expected (1+z)1/2 angular diameter scaling of brightness temperature limited sources resulting from cosmological expansion. We report here 4.9 GHz and 8.4 GHz observations and data analysis for a sample of 140 compact, fiat-spectrum sources which may allow us to determine the origin of this angular diameter-redshift relation by exploiting their different wavelength dependences. In addition to using ISS as a cosmological probe, the observations provide additional insight into source morphologies and the characteristics of ISS. As in the MASIV Survey, the variability of the sources is found to be significantly correlated with line-of-sight H(alpha) intensities, confirming its link with ISS. For 25 sources, time delays of about 0.15 to 3 days are observed between the scintillation patterns at both frequencies, interpreted as being caused by a shift in core positions when probed at different optical depths. Significant correlation is found between ISS amplitudes and source spectral index; in particular, a large drop in ISS amplitudes is observed at alpha < -0.4 confirming that steep spectrum sources scintillate less. We detect a weakened redshift dependence of ISS at 8.4 GHz over that at 4.9 GHz, with the mean variance at 4-day timescales reduced by a factor of 1.8 in the z > 2 sources relative to the z < 2 sources, as opposed to the factor of 3 decrease observed at 4.9 GHz. This suggests scatter broadening in the IGM, but the interpretation is complicated by subtle selection effects that will be explored further in a follow-up paper.

Koay, J. Y.

Scintillating Quantum Dots for Imaging X-Rays (SQDIX) for Aircraft Inspection

Scintillation is the process currently employed by conventional X-ray detectors to create X-ray images. Scintillating quantum dots (StQDs) or nano-crystals are novel, nanometer-scale materials that upon excitation by X-rays, re-emit the absorbed energy as visible light. StQDs theoretically have higher output efficiency than conventional scintillating materials and are more environmentally friendly. This paper will present the characterization of several critical elements in the use of StQDs that have been performed along a path to the use of this technology in wide spread X-ray imaging. Initial work on the scintillating quantum dots for imaging X-rays (SQDIX) system has shown great promise to create state-of-the-art sensors using StQDs as a sensor material. In addition, this work also demonstrates a high degree of promise using StQDs in microstructured fiber optics. Using the microstructured fiber as a light guide could greatly increase the capture efficiency of a StQDs based imaging sensor.

Burke, E. R.

Fast and bright scintillators for ultrafast materials dynamics using 4th generation synchrotron

We present recent advances in fast and bright scintillators for ultrafast X-ray phase contrast imaging of dynamic materials experiments at the upgraded Advanced Photon Source (APS-U), a fourth generation synchrotron. APS-U enables hard X-ray imaging at frame rates of at least 13 MHz (corresponding to 77 ns or shorter interframe intervals), creating a new need for scintillators with faster response and higher light output than lutetium yttrium oxyorthosilicate (LYSO). For indirect imaging and diffraction with ultrafast cameras, commercial lanthanum bromide (LaBr3) and cerium bromide (CeBr3) are promising candidates. These materials exhibit decay times approximately a factor of two shorter than LYSO (around 40 ns) and lutetium oxyorthosilicate (LSO), while maintaining comparable light yield per incident X-ray photon. However, their implementation at APS-U requires addressing several challenges, including material limitations due to hygroscopicity, efficient optical coupling to imaging systems, and high quantum efficiency for conversion of scintillation light, predominantly at wavelengths below 400 nm, into detectable electronic signals. We report results from material characterization, detector integration and packaging, and beamline experiments of materials with impact. In addition, emerging scintillator classes, including perovskites and high-entropy materials, are discussed as potential alternatives for next-generation ultrafast X-ray diagnostics.

Wang, Zhehui [Los Alamos] (ORCID:0000000178264063)

Performance of large-scale 6 Li-doped pulse-shape discriminating plastic scintillators

A 6 Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ -299-50, has been developed and produced at the kilogram-scale. A total of 44 bars of dimensions 5.5 cm x 5.5 cm x 50 cm of this material have been characterized. Optical properties like light output and effective attenuation length have been found to be comparable to 6 Li-doped liquid scintillators. Further, the scintillator EJ -299-50 shows good neutron detection capabilities with an effective efficiency for capture on 6 Li of approximately 85%. Stability tests performed on two formulation variations showed no intrinsic degradation in the material or optical properties during several months of observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

The scintillator surface detector of the Pierre Auger observatory

Data collected so far by the Pierre Auger Observatory have enabled major advances in ultra-high energy cosmic ray physics and demonstrated that improved determination of masses of primary cosmic-ray particles, preferably on an event-by-event basis, is necessary for understanding their origin and nature. Improvement in primary mass measurements was the main motivation for the upgrade of the Pierre Auger Observatory, called AugerPrime. As part of this upgrade, scintillator detectors are added to the existing water-Cherenkov surface detector stations. By making use of the differences in detector response to the electromagnetic particles and muons between scintillator and water-Cherenkov detectors, the electromagnetic and muonic components of cosmic-ray air showers can be disentangled. Since the muonic component is sensitive to the primary mass, such combination of detectors provides a powerful way to improve primary mass composition measurements over the original Auger surface detector design. In this paper, the so-called Scintillator Surface Detectors are discussed, including their design characteristics, production process, testing procedure and deployment in the field.

Detector design and construction technologies and

Ionospheric S4 Scintillations From GNSS Radio Occultation (RO) at Slant Path

Ionospheric scintillation can significantly degrade the performance and the usability of space‐based communication and navigation signals. Characterization and prediction of ionospheric scintillation can be made from the Global Navigation Satellite System (GNSS) radio occultation (RO) technique using the measurement from a deep slant path where the RO tangent height (ht) is far below the ionospheric sources. In this study, the L–band S4 from the RO measurements at ht = 30 km is used to infer the amplitude scintillation on the ground. The analysis of global RO data at ht = 30 km shows that sporadic–E (Es), equatorial plasma bubbles (EPBs), and equatorial spread–F (ESF) produce most of the significant S4 enhancements, although the polar S4 is generally weak. The enhanced S4 is a strong function of local time and magnetic dip angle. The Es–induced daytime S4 tends to have a negative correlation with the solar cycle at low latitudes but a positive correlation at high latitudes. The nighttime S4 is dominated by a strong semiannual variation at low latitudes.

GPS radio occultation

Light output and neutron detection efficiency of boron-based neutron scintillator screens for neutron imaging

Recent research has explored the development of boron-based neutron scintillator screens, which potentially offer improved spatial resolution and neutron capture efficiency compared to traditional lithium-based screens. This work builds upon previous efforts to improve boron-based neutron scintillators by assessing a newer generation of boron-based scintillator screens fabricated using different compositions and fabrication approaches compared to previous generations of screens. Some of the test screens exhibit higher light output than previous efforts and higher neutron capture efficiency than lithium-based screens. This paper describes the current state of screen development, measurement results for the most recent generation of screens, and future activities.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Nonlinear light-output calibration of the oxygenated xylene scintillators used in OMEGA neutron time-of-flight spectrometers

Neutron time-of-flight (nTOF) spectrometers are essential instruments for measuring and evaluating the performance of inertial confinement fusion implosions. The neutron spectrometers utilized for the OMEGA laser include two liquid-based scintillators, each consisting of a large volume filled with xylene that is coupled to four photomultiplier tubes. Analysis of the signal from these detectors requires detailed knowledge of the scintillator’s light output, which is needed to fit the nTOF spectrum, from which the neutron energy spectrum is informed. The light output is nonlinearly proportional to the neutron energy, which, in turn, affects the interpretation of the neutron energy spectrum from a TOF signal. A recent campaign on OMEGA was performed to calibrate the xylene detectors and infer the shape of the light-output curve. The campaign utilized materials with increasing Z placed in the OMEGA target chamber to initiate scattering events with the 14 MeV fusion neutrons. This process leads to the production of backscatter neutrons of varying energies that appear as peaks in the nTOF data. Simulations using a neutron transport code were combined with the measured deuterium–tritium neutron yields to calculate the expected backscattered neutron yields from the well-known scattering cross sections of each material. Furthermore, the neutron-energy dependent light output of the scintillator inferred from the experiment is compared to the light-output curve simulated with a neutron transport code for the following neutron energies: 1.5, 2.5, 6, and 14 MeV.

47 OTHER INSTRUMENTATION

Scintillation light detection in polycrystalline diamond using single photon detectors

Here, this study investigates the scintillation properties of polycrystalline diamond for particle detection applications, particularly in neutron and alpha radiation environments. Polycrystalline diamonds provide a cost-effective alternative to monocrystalline diamonds while retaining essential detection properties. Photoluminescence measurements were performed to analyze emission spectra, revealing distinct characteristics based on impurity content and crystallinity. Scintillation responses were assessed using Silicon Photomultipliers (SiPMs), demonstrating the capability of polycrystalline diamond powders to respond to alpha irradiation, albeit with reduced resolution compared to traditional scintillators. A prototype neutron detector was developed by combining diamond powder with neutron-sensitive 6 LiF, and its performance was evaluated through experimental testing and Geant4 simulations. The findings indicate that polycrystalline diamond-based detectors can achieve significant detection efficiency while remaining insensitive to gamma radiation, offering potential for portable neutron detection applications.

47 OTHER INSTRUMENTATION

Detection of uranium-photofission neutrons with a 4 He scintillation detector

The use of photon active interrogation to detect special nuclear material has held significant theoretical promise, as the interrogating source particles, photons, are fundamentally different from one of the main signatures of special nuclear material: neutrons produced in nuclear fission. However, neutrons produced by photonuclear reactions in the accelerator target, collimator, and environment can obscure the fission neutron signal. These (γ, n) neutrons could be discriminated from fission neutrons by their energy spectrum, but common detectors sensitive to the neutron spectrum, like organic scintillators, are typically hampered by the intense photon background characteristic of photon-based active interrogation. In contrast, high-pressure 4 ⁢He-based scintillation detectors are well-suited to photon active interrogation, as they are similarly sensitive to fast neutrons and can measure their spectrum, but show little response to gamma rays. Here, in this work, a photon active interrogation system utilizing a 4 ⁢He scintillation detector and a 9 MeV linac-bremsstrahlung x-ray source was experimentally evaluated. The detector was shown to be capable of operating in intense gamma-ray environments and detecting photofission neutrons from 238 ⁢U when interrogated by this x-ray source. The photofission neutrons show clear spectral separation from (γ, n) neutrons produced in lead, a common shielding material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Proton Quenching in Rare-Earth Inorganic Scintillators: GAGG:Ce and YSO:Ce

Scintillator detectors are an integral component of radiation detection systems for a variety of applications such as medical imaging, accelerator diagnostics, and space science. Typically, a scintillator detector’s response is characterized using gamma sources to understand the detection response to different types of radiation, including charged particle detection. However, there exists a nonlinearity of the amount of light produced from an incident gamma ray of specific energy and the light produced from an incident charged particle of the same energy. This important effect, known as quenching, must be accounted for to interpret energies from charged particles incident on detectors. In this article, we present results of quenching parameterization for two types of cerium-doped inorganic scintillators, Y2SiO5:Ce (YSO:Ce) and Gd3Al2Ga3O12:Ce (GAGG:Ce). We measured the light output from incident proton energies from 1 to 25 MeV using a 3-MV tandem accelerator and two reactions: Au(p,p)Au and 3He(d,p)⁴He. Using gamma-ray sources to calibrate the detectors, we compared the measured electron-equivalent energy versus the incident energy expected. Using an adaptation of the Birks semi-empirical formula, we extracted the Birks parameter (kB) to understand quenching. For one of the GAGG:Ce samples, the kB parameter of 0.0072 [g cm-2 MeV-1] is comparable to a similar study where the value of kB was 0.0065 [g cm-2 MeV-1]. For YSO:Ce, no other kB values were found in the literature. Three different types of GAGG:Ce were used to collect measurements of kB as a function of dopant concentration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION