Search NASASearch

SEARCH · Search NASA

Results for “Sodium-ion batteries”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

536 records · Page 6

Lyotropic Liquid Crystalline Phase Behavior of Boron Nitride Nanotube Aqueous Dispersions

Boron nitride nanotubes (BNNTs) are gaining significant interest due to their outstanding mechanical and thermal properties, as well as their potential to serve as a model nanorod system. Processing BNNT liquid crystalline (LC) dispersions enables precise control over BNNT orientation in macroscopic assemblies, while their low absorption in the visible spectrum facilitates studying LCs at exceptionally high concentrations. Here, we investigate the behavior of BNNTs in aqueous solutions stabilized by the surfactant sodium deoxycholate (SDC), examining the effect of BNNT purity and BNNT−SDC concentrations on lyotropic LC formation. We disperse up to 15wt% BNNT in SDC solutions and use polarized light microscopy to detail the transition from an isotropic state to a biphasic regime, where isotropic and nematic domains coexist due to phase separation, to a single fully nematic phase. Cryogenic electron microscopy provides direct evidence of BNNT alignment within nematic domains. Our results show that enhanced depletion-induced attractions, driven by increased surfactant concentration, lower the threshold concentration of BNNT required to form nematic domains. In contrast, low surfactant concentrations relative to BNNT result in insufficiently coated nanotube surfaces, leading to poor dispersions and BNNT aggregation. Additionally, we fabricate well-aligned BNNT films from aqueous LC dispersions. Our findings advance the understanding of BNNT LCs, offering insight into controlling their orientation and highlighting their potential for high-performance materials.

Joe Khoury

Recommended Practice for Use of ExB Probes in Electric Propulsion Testing

An ExB probe is an electric propulsion plume diagnostic that has at its core a Wien filter. Ions entering the instrument experience perpendicular electric and magnetic fields and are filtered based on their velocity. While the ExB probe can be used to estimate the ion velocity distribution function, in the electric propulsion community, it is commonly used to measure species fractions. There are numerous probe designs, implementation and operation procedures, and data analysis approaches described and in use across the community. This paper provides recommendations and descriptions of best practices for design, implementation, and data analysis for the ExB probe, with a particular emphasis on Hall and ion thrusters. This work contributes to the broader community goal to standardize the use of diagnostics in electric propulsion testing.

ExB probe

Second LDEF Post-Retrieval Symposium Abstracts

These abstracts from the symposium represent the data analysis of the 57 experiments flown on the LDEF. The experiments include materials, coatings, thermal systems, power and propulsion, science, (cosmic ray, interstellar gas, heavy ions, micrometeoroids, etc.), electronics, optics, and life science.

Arlene S. Levine

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD

Spacecraft Fire Safety Predictions using Verified Saffire Model

A model developed using Fire Dynamics Simulator (FDS) that aimed to determine the effect of a fire in a spacecraft was validated by data collected during the Saffire campaign. The model used inlet and outlet temperatures and CO 2 concentrations of the Saffire payload where fire spread was taking place to determine the amount of heat and combustion products that made it into Northrop Grumman’s Cygnus vehicle. The model was then validated using six remote sensors in various places in the vehicle, as well as a far field device (FFD) in the open zenith section that was representative of average vehicle values. The current work focuses on using the model to predict fire safety scenarios. One simulation aimed to determine the fate of HCl, which sticks to surfaces. The model prediction showed that the HCl was removed from the atmosphere rapidly. This compared well against the FFD data in the Saffire VI campaign event where a bottle of 5% HCl was released into the vehicle. An additional simulation where the Environmental Control and Life Support System (ECLSS) was shut off once the FFD reached 5 ppm of HCl showed that HCl stayed in the atmosphere considerably longer. Continuing the simulation with the ECLSS activated and after temperatures returned to their initial conditions, resulted in a rapid removal of HCL similar to that observed in the original HCl release scenario model. Finally, a simulation that used the heat release rate from a lithium-ion battery test to determine the effect it would have on a spacecraft was performed. This simulation used a heat addition rate that is considerably higher than what was determined from the burning of solid fuels in the Saffire campaign and hence produced a non-trivial temperature increase in more locations within the vehicle.

Fire Safety