ACOUSTOELECTRIC SURFACE ACOUSTIC WAVE SWITCH IN AN EPITAXIAL INGAAS ON LITHIUM NIOBATE HETEROSTRUCTURE.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
ECS 239th Meeting, Virtual, May 30-June 3, 2021
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Updated aging data for SAW oscillators with aluminum transducers on ST-cut quartz, for gold transducers on ST-cut quartz, and for aluminum transducers on SiO2/LiTaO3. Devices with gold transducers age differently (both and shape of curve) from those having a aluminum transducers indicating the transducer metallization can represent an important aging mechanism.
Two 2.2 GHz SAW oscillators using aluminum nitride on sapphire (AlN/Al2O3) delay lines were fabricated. The oscillators were electronically temperature compensated and characterized. One of the oscillators was used as the frequency reference for the Ku band source; the second oscillator is available for continued evaluation. A 15 GHz frequency source was designed and fabricated. The 15 GHz source consists of a Ku band FET oscillator which is phase locked to the frequency multiplied (X7) output of the 2.2 GHz SAW reference source. The Ku band source was built using microstrip circuit designs, which are hybrid compatible. Two wafer runs of 2.2 GHz TED devices were fabricated and evaluated. The devices were mounted on microstrip test substrates and evaluated as 15 GHz divide by 7 circuits. The device evaluation indicated that in their present form the TED is not a practical circuit element.
Explore the source record for details and available documents.
The development of a 200 MHz SAW instrument based on an SAW resonator instead of a conventional delay line is reported. The instrument is small, compact, and uses two separate 200 MHz resonataor crystals which operate in the dual difference mode. The difference frequency stability is better than 5 x 10 to the -9th (+ or - 1 Hz) which is comparable to a 10 MHz bulk crystal and at least an order of magnitude better than other commercially available SAW delay lines that operate at comparable frequencies. The mass sensitivity is about 9 x 10 to the 10th Hz sq cm/g. Response to temperature change is found to be about 20 Hz/C from -30 C to 30 C. Response to pressure is found to be linear from 760 to 415 Torr at 3 Hz/Torr. Detection limits for HCl vapors were determined to be in the low ppb range using an SAW resonator coated with triethanolamine.
This Final Report for the PSAW/MicroSWIS Program is provided in compliance with contract number NAS3-01118. This report documents the overall progress of the program and presents project objectives, work carried out, and results obtained. Program Conceptual Design Package stated the following objectives: To develop a sensor/transceiver network that can support networking operations within spacecraft with sufficient bandwidth so that (1) flight control data, (2) avionics data, (3) payload/experiment data, and (4) prognostic health monitoring sensory information can flow to appropriate locations at frequencies that contain the maximum amount of information content but require minimum interconnect and power: a very high speed, low power, programmable modulation, spread-spectrum radio sensor/transceiver.
Explore the source record for details and available documents.
The present invention provides a delay line SAW device fabricated on a lithium niobate substrate and coated with a bilayer of nanocrystalline or other nanomaterials such as nanoparticles or nanowires of palladiumn and metal free pthalocyanine which will respond to hydrogen gas in near real time, at low (room) temperature, without being affected by CO, O.sub.2, CH.sub.4 and other gases, in air ambient or controlled ambient, providing sensitivity to low ppm levels.
No abstract provided
Presented by LRST at the Monthly Colloquium, University of South Alabama, 11/12
Presented by LRST at the IEEE IUS 2020, Las Vegas (Virtual), September 6-7, 2020, 9/7
<p style="text-align: justify;"><span style="font-family: Arial; font-size: 10pt;">• </span><span style="color: black; font-family: Arial; font-size: 10pt;">SAW reflective delay line devices were designed and successfully fabricated on Langasite by patterning platinum electrodes.</span><p style="text-align: justify;"><span style="font-family: Arial; font-size: 10pt;">• </span><span style="color: black; font-family: Arial; font-size: 10pt;">Fabricated devices successfully tested up to 500°C for temperature sensing applications.</span><p style="text-align: justify;"><span style="font-family: Arial; font-size: 10pt;">• </span><span style="color: black; font-family: Arial; font-size: 10pt;">Indium oxide (IO) and indium tin oxide (ITO) sensing layers were developed on the SAW devices using sputtering and sol-gel method.</span><p style="text-align: justify;"><span style="font-family: Arial; font-size: 10pt;">• </span><span style="color: black; font-family: Arial; font-size: 10pt;">IO- and ITO-functionalized langasite SAW reflective delay line devices were used for sensing H2 and O2 at 350°C. </span><br>
Monthly Colloquium, University of South Alabama, Mobile, Alabama, Nov 12, 2020