Search NASASearch

SEARCH · Search NASA

Results for “Technology Readiness Level”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

469 records · Page 6

Integrated Inverter And Battery Charger

Circuit combines functions of dc-to-ac inversion (for driving ac motor in battery-powered vehicle) and ac-to-dc conversion (for charging battery from ac line when vehicle not in use). Automatically adapts to either mode. Design of integrated inverter/charger eliminates need for duplicate components, saves space, reduces weight and cost of vehicle. Advantages in other applications : load-leveling systems, standby ac power systems, and uninterruptible power supplies.

Rippel, Wally E.

Gateway Element and Payload Materials Outgassing Analyses: HALO, HERMES, and ERSA

Gateway was intended to be humanity’s first space station around the Moon, but its development has been paused as the National Aeronautics and Space Administration (NASA) shifts focus to achieving the United States’ National Space Policy goals. Instead of an orbiting lunar outpost, NASA will now pursue the development of a lunar surface base to support a sustained human presence on the Moon. Before the program’s pause, Gateway’s Induced Environments team worked to ensure payloads and elements (i.e., modules) complied with induced environment requirements. Methods developed and insights gained from this work will have applicability to NASA’s Moon Base and the potential repurposing of Gateway elements and payloads, as well as to induced environments modeling for future space stations. The Gateway program’s induced environment included molecular contamination, electric thruster plume sputter and redeposition, and lunar dust transfer from the Human Landing System (HLS). Primary sources of external molecular contamination included materials outgassing, chemical thruster plume contamination, and vacuum venting. The focus of this paper will be on element- and payload-level materials outgassing analyses performed for Gateway Configuration 1, extending the previously-developed framework for Gateway system-level external molecular contamination modeling. Gateway Configuration 1 consisted of the Power and Propulsion Element (PPE) and the Habitation and Logistics Outpost (HALO). It also included payloads like the European Radiation Sensor Array (ERSA) attached to PPE and the Heliophysics Environmental and Radiation Measurement Experiment Suite (HERMES) attached to HALO. The element- and payload-level analyses to be introduced in this paper for HALO, HERMES, and ERSA enabled high-fidelity descriptions of Gateway’s external molecular contamination environment. Approaches to geometric modeling, meshing, outgassing rate assignment, molecular transport modeling, and analysis methodology will be presented. Element and payload contaminant deposition onto sensitive Gateway receiver surfaces will be summarized and results compared to induced environment requirements. While these results incorporate refinements made over the course of the program, they were not intended to be final. Therefore, modeling assumptions and inputs, potential improvements, and lessons-learned will be documented to inform future work on Moon Base, repurposed elements and payloads, and other space stations.

Gateway

Vaporization Would Cool Primary Battery

Temperature of discharging high-power-density primary battery maintained below specified level by evaporation of suitable liquid from jacket surrounding battery, according to proposal. Pressure-relief valve regulates pressure and boiling temperature of liquid. Less material needed in cooling by vaporization than in cooling by melting. Technique used to cool batteries in situations in which engineering constraints on volume, mass, and location prevent attachment of cooling fins, heat pipes, or like.

Bhandari, Pradeep

Practical Tips for Setting Up an LS-DYNA MAT_213 Analysis

Since 2012, NASA has actively contributed to the development and application of the LS-DYNA MAT_213 material model to predict responses under dynamic loading events. This presentation provides a high-level overview of MAT_213 and captures practical tips and suggestions for using it.

MAT_213

3D Woven Mid-Density Carbon Phenolic (3MDCP) Full-Scale Heatshield Development for Mars Sample Return (MSR) Earth Entry System (EES)

The Mars Sample Return (MSR) mission will be returning samples of Martian soil to Earth. The samples will be returned in the Earth Entry System (EES). The EES capsule is protected by a new thermal protection system; the 3-Dimensionally Woven, Mid-Density, Carbon Phenolic (3MDCP) material which is derived from the Heatshield for Extreme Entry Environment Technology (HEEET). The baseline 3MDCP design is a single piece thermal protection system that avoids the manufacturing and certification challenges associated with a tiled configuration. A 3MDCP heatshield begins as a flat woven preform that is formed to the final heatshield shape and then infused with phenolic resin. A NASA Ames lead team, in collaboration with Spirit Textiles (formerly TEAM Inc.), Fiber Materials Inc. (FMI, a Spirit AeroSystems Company), and Kratos SRE, has been developing and demonstrating the processes to fabricate the 3MDCP heatshield and characterize the resulting properties. The process of forming the flat woven preform into the final heatshield shape, a sphere-cone geometry with a 52.5° cone angle, involves local but substantial movement of the yarns in the weave. This results in continuous fibers across the single piece heatshield, albeit with property variations between different regions of the heatshield. This presentation will provide a high-level status of 3MDCP development for the MSR EES heatshield. This will include an overview of the manufacturing processes with an emphasis on the impact of forming on fiber orientation, material properties, and performance. Results comparing preliminary formed and flat materials will be shown. Additionally, the presentation will layout the broader plan for property testing and tie-in to aerothermal performance.

Peter Edward Marshall

A method for battery activation

A technique to activate nickel cadmium batteries is described. The method shortened the time required for activation, eliminated the temperature rise in the batteries, and produced a voltage on the discharge that was better than when the C/20 was run for 48 hours during tests. Various methods of activation are described and evaluated. Results of alternate conditioning charge schemes are presented along with voltage/temperature characteristics for multiple level nickel cadmium battery chargers.

Halpert, G.

Performance of Li-Ion Cells Under Battery Voltage Charge Control

A study consisting of electrochemical characterization and Low-Earth-Orbit (LEO) cycling of Li-Ion cells from three vendors was initiated in 1999 to determine the cycling performance and to infuse the new technology in the future NASA missions. The 8-cell batteries included in this evaluation are prismatic cells manufactured by Mine Safety Appliances Company (MSA), cylindrical cells manufactured by SAFT and prismatic cells manufactured by Yardney Technical Products, Inc. (YTP). The three batteries were cycle tested in the LEO regime at 40% depth of discharge, and under a charge control technique that consists of battery voltage clamp with a current taper. The initial testing was conducted at 20 C; however, the batteries were cycled also intermittently at low temperatures. YTP 20 Ah cells consisted of mixed-oxide (Co and Ni) positive, graphitic carbon negative, LIPF6 salt mixed with organic carbonate solvents. The battery voltage clamp was 32 V. The low temperature cycling tests started after 4575 cycles at 20 C. The cells were not capable of cycling. at low temperature since the charge acceptance at battery level was poor. There was a cell in the battery that showed too high an end-of-charge (EOC) voltage thereby limiting the ability to charge the rest of the cells in the battery. The battery has completed 6714 cycles. SAFT 12 Ah cells consisted of mixed-oxide (Co and NO positive, graphitic carbon negative, LiPF6 salt mixed with organic carbonate solvents. The battery voltage clamp was for 30.8 V. The low temperature cycling tests started after 4594 cycles at 20 C. A cell that showed low end of discharge (EOD) and EOC voltages and three other cells that showed higher EOC voltages limited the charge acceptance at the selected voltage limit during charge. The cells were capable of cycling at 10 C and 0 C but the charge voltage limit had to be increased to 34.3 V (4.3 V per cell). The low temperature cycling may have induced poor chargeability since the voltage had to be increased to achieve the required charge input. The battery has completed 6226 cycles. MSA 10 Ah cells consisted of Co oxide positive, graphitic carbon negative, LiPF6 salt mixed with organic carbonate solvents. The battery voltage clamp was 30.8 V. The low temperature cycling tests were started after 2182 cycles at 20 C. The cells were capable of cycling at 10 C and 0 C. Like SAFT, the voltage limit on charge had to be increased to 36 V (4.5 V per cell). There was a cell (cell S/N 13) in the battery that showed poor performance features such as low EOD voltage and high EOC voltage. The battery has completed 3441 cycles. A reconditioning procedure that consisted of C15 charge to a taper current of C/100 and C/20 discharge improved the voltage behavior of SAFT and MSA cells with no significant effect on YTP cells. We have demonstrated that the charge operation with VT clamp at battery rather than at cell level is feasible for onboard Li-Ion battery operation.

Rao, Gopalakrishna M.

MSFC Thermal Testing Lessons Learned Course. Section 3: Lessons Learned from Protoflight StarBurst Instrument Thermal Vacuum Test

MSFC thermal engineers will be presenting lessons learned while preparing and conducting thermal tests. This course will cover practical real world examples of thermal chamber and vacuum chamber testing from engineering development units to system level testing on flight hardware. Special topics include large scale testing preparation, requirement tailoring from parent documents, and cryogenic development testing.

thermal discipline

High Capacity Battery Cell Flight Qualified

The High Capacity Battery Cell project is an effort equally funded by the NASA Lewis Research Center and Hughes Space and Communications Company (a unit of Hughes Aircraft Company) to develop and flight qualify a higher capacity nickel hydrogen battery for continuing use on commercial spacecraft. The larger diameter, individual pressure vessel cell will provide approximately twice the power, while occupying the same volume, as the current state-of-the-art nickel hydrogen cell. These cells are also anticipated to reduce battery cost by 20 percent. The battery is currently booked for use on 26 spacecraft, with the first flight scheduled in 1997. A strong requirement for batteries with higher power levels (6 to 12 kW), long life, and reduced cost was identified in studies of the needs of commercial communications spacecraft. With the design developed in this effort, the higher power level was accommodated without having to modify the rest of the existing spacecraft bus. This design scaled-up the existing state-of-the-art nickel hydrogen battery cell from a 3.5-in., 50-Ahr cell to a 5.5-in., 350-Ahr cell. An improvement in cycle life was also achieved by the use of the 26-percent KOH electrolyte design developed by NASA Lewis. The cell design was completed, and flight batteries were built and flight qualified by Hughes Space and Communications Company with input from NASA Lewis. Two batteries were shipped in September 1996 to undergo life cycle testing under the purview of NASA Lewis.

McKissock, Barbara I.

Designing a Propylene-Glycol Coolant Servicer System for Gateway’s Internal Active Thermal Control System

A human spacecraft ATCS—especially one using single-phase coolant loops exposed to cabin atmospheric conditions—requires periodic degassing and refilling to support long-duration missions of 15 to 30 years. During initial fill operations, system maintenance, gas permeation, and quick-disconnect mating or de-mating, small amounts of gas can gradually enter the coolant system over time. This can lead to degraded heat transfer performance, pump cavitation, and potentially pump vapor lock if a significant gas volume accumulates over time. Additionally, system leaks and routine fluid sampling can gradually reduce accumulator volumes to unacceptable levels, requiring periodic refills. In more severe cases, catastrophic changes in fluid composition may necessitate emergency draining, refilling, and degassing to ensure continued system functionality. These risks were identified and mitigated on the ISS ITCS through the development of a dual-membrane degasser ORU and a Fluid Servicer System ORU for coolant refilling. These systems were developed for the fully water-based ISS ITCS Coolant[1]. The Gateway space station, the first permanent human habitat in lunar orbit, uses a propylene-glycol/water coolant mixture, which has significantly different fluid properties compared to pure water. Because microgravity degassing technologies are sensitive to fluid surface tension and viscosity, existing ISS hardware is not suitable for servicing a propylene-glycol-based TCS. Unlike the ISS, the Gateway will operate in a higher-radiation environment and must meet stricter mass constraints due to its location outside of low earth orbit. This Government Furnished Equipment (GFE) flight hardware project aims to develop a lightweight, radiation-resistant Coolant Servicer System (CSS) capable of degassing and refilling Gateway’s propylene-glycol water-based IATCS.

Propylene Glycol Water

Designing a Propylene-Glycol Coolant Servicer System for Gateway’s Internal Active Thermal Control System

A human spacecraft ATCS—especially one using single-phase coolant loops exposed to cabin atmospheric conditions—requires periodic degassing and refilling to support long-duration missions of 15 to 30 years. During initial fill operations, system maintenance, gas permeation, and quick-disconnect mating or de-mating, small amounts of gas can gradually enter the coolant system over time. This can lead to degraded heat transfer performance, pump cavitation, and potentially pump vapor lock if a significant gas volume accumulates over time. Additionally, system leaks and routine fluid sampling can gradually reduce accumulator volumes to unacceptable levels, requiring periodic refills. In more severe cases, catastrophic changes in fluid composition may necessitate emergency draining, refilling, and degassing to ensure continued system functionality. These risks were identified and mitigated on the ISS ITCS through the development of a dual-membrane degasser ORU and a Fluid Servicer System ORU for coolant refilling. These systems were developed for the fully water-based ISS ITCS Coolant[1]. The Gateway space station, the first permanent human habitat in lunar orbit, uses a propylene-glycol/water coolant mixture, which has significantly different fluid properties compared to pure water. Because microgravity degassing technologies are sensitive to fluid surface tension and viscosity, existing ISS hardware is not suitable for servicing a propylene-glycol-based TCS. Unlike the ISS, the Gateway will operate in a higher-radiation environment and must meet stricter mass constraints due to its location outside of low earth orbit. This Government Furnished Equipment (GFE) flight hardware project aims to develop a lightweight, radiation-resistant Coolant Servicer System (CSS) capable of degassing and refilling Gateway’s propylene-glycol water-based IATCS.

Propylene Glycol Water

Transient Studies of G-Induced Capillary Dryout and Rewet

A transient, one-dimensional numerical code is developed to model the liquid motion in an axial groove with square cross section. Axial variation in liquid level, shear stress and heat transfer between the groove wall and the liquid, evaporation and transient body forces are accounted for in the model. Dryout and rewet of the groove are allowed; the front location is determined numerically using conservation of mass and linear extrapolation. Several numerical test results are presented and discussed.

M K Reagan

Comparison Testing and Analysis of Braided Cords Constructed from Varying Kevlar Fiber Types

Material advancements move quickly, resulting in material obsolescence issues that require parachute engineers to understand how the material properties change with a material upgrade and if there are expected impacts to overall performance of the parachute. The objective of this test was to measure the elongation of different Kevlar types at both the cord-level and at the yarn-level to determine if a change in Kevlar type impacted parachute performance. An Instron machine with a pin-to-pin connection was used to measure load and displacement time histories for various Kevlar cord and yarn samples in a cyclic load profile. Twenty-four cord samples and twenty-four yarn samples were tested; each sample was cycled five times to the relevant maximum load (either to breaking strength or to the 30% peak load expected in flight). In addition to the Instron measurements, a photogrammetric technique was also implemented to measure elongation of the samples using button targets. Modulus test data shows approximately a 10% difference in elongation between Kevlar 29AP and Kevlar 129, and another 10% difference in elongation between Kevlar 29 and Kevlar 29AP. Although this is a measurable change in modulus, the effect on parachute performance is likely small, particularly for non-primary structure elements of relatively small length. This test campaign provides an example of the type of testing and analysis that parachute engineers could do to understand how material upgrades affect performance of their systems.

Modulus Testing

Selecting an Encapsulant for an Aerospace Superconducting Machine

Achieving larger benefits from electrified propulsion in single aisle aircraft (the largest commercial aircraft market segment) necessitates that a significant fraction of their 20 MW or greater propulsion system be electrified. 5 to possibly 20 of the MW-scale electric machines investigated by NASA would be required to meet this need. Approximately 10-20 of NASA’s MW-scale electric machines would be required to reach the necessary power levels. Therefore, electric machines of 5 MW or greater are of interest. However, conventionally cooled high power density MW-scale electric machines still produce a significant amount of waste heat, which makes obtaining these power levels problematic. Highly efficient fully superconducting electric machines (or those with a cryogenically cooled, high purity copper or aluminum stator) are a possible solution but have multiple barriers to be overcome. One such barrier is the durability of superconducting windings. Superconductors are typically brittle, and encapsulants used to hold windings in place are a significant source of stress because of the mismatches in coefficient of thermal expansion at temperatures between room temperature and operational temperatures (20 to 77 K). These encapsulants also form a thermal barrier that can be detrimental to cooling the superconductors. This paper describes an initial study of commercially available encapsulants as it relates to superconducting machine applications along with initial modeling of thermal stress in superconducting windings for a superconducting or cryogenically cooled stator in a 5 MW electric machine.

encapsulant

Comparison Testing and Analysis of Braided Cords Constructed from Varying Kevlar Fiber Types

Material advancements move quickly, resulting in material obsolescence issues that require parachute engineers to understand how the material properties change with a material upgrade and if there are expected impacts to overall performance of the parachute. The objective of this test was to measure the elongation of different Kevlar types at both the cord-level and at the yarn-level to determine if a change in Kevlar type impacted parachute performance. An Instron machine with a pin-to-pin connection was used to measure load and displacement time histories for various Kevlar cord and yarn samples in a cyclic load profile. Twenty-four cord samples and twenty-four yarn samples were tested; each sample was cycled five times to the relevant maximum load (either to breaking strength or to the 30% peak load expected in flight). In addition to the Instron measurements, a photogrammetric technique was also implemented to measure elongation of the samples using button targets. Modulus test data shows approximately a 10% difference in elongation between Kevlar 29AP and Kevlar 129, and another 10% difference in elongation between Kevlar 29 and Kevlar 29AP. Although this is a measurable change in modulus, the effect on parachute performance is likely small, particularly for non-primary structure elements of relatively small length. This test campaign provides an example of the type of testing and analysis that parachute engineers could do to understand how material upgrades affect performance of their systems.

Parachutes

Synthetic battery cycling

The use of interactive computer graphics is suggested as an aid in battery system development. Mathematical representations of simplistic but fully representative functions of many electrochemical concepts of current practical interest will permit battery level charge and discharge phenomena to be analyzed in a qualitative manner prior to the assembly and testing of actual hardware. This technique is a useful addition to the variety of tools available to the battery system designer as he bridges the gap between interesting single cell life test data and reliable energy storage subsystems.

Thaller, L. H.

GOPEX at the Starfire Optical Range

The Starfire Optical Range successfully conducted laser upink experiments to the Galileo spacecraft during the early morning hours of December 9, 10, 11, and 12, 1992, when the spacecraft was at ranges between 700,000 and 3 million km from Earth. Analysts at JPL have reported as many as 79 pulse detections by the spacecraft. The best weather conditions occurred on the second night when 37 pulses were detected with as many as five on one frame. Signal levels at the spacecraft generally agree with predictions.

R Q Fugate

Radio Noise Problems in Arctic Regions

Three main types of radio noise should be considered when establishing noise levels for communication purposes or in experiments utilizing radio techniques in Arctic regions. These are atmospheric and man-made noise, and precipitation static. National Bureau of Standards radio noise data obtained hourly at Arctic and Antarctic stations on eight .fixed frequencies between 51 kc and 20 Mc/s are analyzed to show the characteristics of the three types. The diurnal and seasonal variations of atmospheric radio noise at high latitudes are explainable in terms of changes in propagation factors and in the distribution of world thunderstorm activity. In both northern and southern Arctic regions atmospheric noise decreases during polar cap absorption (PCA), most markedly in the h.f. band. The probable magnitude of man-made noise in the h.f. band is estimated from data taken during PCA, when atmospheric noise is absent. At Thule man-made noise on 2.5 and 5 Mc/s appears to be 57 and 49 dB above kTB (where kTB is antenna thermal noise power), respectively, while at Byrd Station the values are about 20 and 12 dB respectively. Precipitation static is generated on exposed antennas during periods of blowing snow (blizzards). The noise power magnitude can be at least 50 dB above man-made and atmospheric levels, but the maximum enhancement cannot be ascertained because of missing data. In winter and spring months at Byrd Station radio data dependent upon exposed antennas may be lost 10-30 per cent of the time due to precipitation static alone.

Radio Noise