Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacitor sizing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Feasibility of Electrostriction for Measurement of the Critical Temperature in the Critical Viscosity Experiment

The large compressibility of a pure fluid near its critical point is a potential means of measuring the critical temperature. At the suggestion of Prof. Ferrell we observed electrostriction in xenon by applying a large voltage across a small, open capacitor immersed in the sample and then measuring the capacitance change caused by the subsequent increase in the xenon's local density. This scheme was attractive because the compressibility is a large, well-understood effect and because we were already familiar with low-voltage capacitance measurements. We found qualitative agreement with our initial expectations based on the fluid's compressibility. However, we also found an additional effect comparable in size to the expected electrostriction but proportional to the applied voltage. We have no explanation for this effect. Thus, given the Science Panel's recommendation against investing extensive effort in this direction, we are abandoning further development of an alternate means for measuring the critical temperature.

Berg, Robert F.↗

A comparison of screening techniques for ceramic capacitors

The techniques involved are ultrasonic scanning, neutron radiography, scanning laser acoustic microscopy, and voltage conditioning. The test capacitor, for this first phase, is a 0.47 uF, 50V capacitor style CKR06. Eighteen of 768 devices failed in voltage conditioning with elapsed times from 15 minutes to 1239 hours. Eleven of the failures were detected by ultrasonic scanning. Four failures were found by neutron radiography. Fourteen failures showed up in the acoustic microscopy test. Three failures in voltage conditioning were not detected by any of the techniques. Failures were confirmed by destructive physical analysis. There is no direct relationship between the size of the defect and electrical failure.

Kiernan, G. F.↗

Low-Temperature Electronic Components Being Developed

In many future NASA missions, such as deep space planetary exploration and the Next Generation Space Telescope, electrical components and systems must operate reliably and efficiently in extremely low temperature environments. Most modern electronic components cannot operate below moderately low operating temperatures (-40 to -55 C). The low-temperature electronics program at the NASA Lewis Research Center is focusing on the development and characterization of low-temperature components and the integration of the developed devices into demonstrable very low-temperature (-200 C) power systems such as dc-dc converters. Such low-temperature electronics will not only tolerate hostile environments but also will reduce system size and weight by eliminating radioisotope heating units, thereby reducing launch cost, improving reliability and lifetime, and increasing energy densities. Low-temperature electronic components will also have a great influence on terrestrial applications such as medical instrumentation, magnetic levitation transportation systems, and arctic and antarctic exploration. Lewis researchers are now performing extensive evaluations of commercially available as well as custom-made devices. These include various types of energy storage and signal capacitors, power switching devices, magnetic and superconducting materials, and primary lithium batteries, to name a few.

Patterson, Richard L.↗

Properties of large nearly perfect crystals at very low temperatures

A liquid helium cryostat of a size and construction unavailable commercially, was built for use in measuring the Q of several materials at milli-Kelvin temperatures. The design and testing of the cryostat is described as well as the design of the experiment vacuum chamber and adaptor for the dilution refrigerator insert. Theory, design, and testing are also discussed for the magnetic coils built to levitate the materials so as to isolate them and increase the measured Q. A four point suspension with capacitor end plates as the transducer was used to obtain preliminary Q measurements of 6061 aluminum alloy and single crystal silicon. Results are tabulated.

Davis, W.↗

Distorted Perovskites for High Voltage Dielectric Capacitors

There are several mechanisms which have been proposed for the existence of colossal dielectric constant in the class of perovskite calcium copper titanate (CaCu3Ti4O12 or CCTO) materials. Researches indicate that existence of twinning parallel to (100) (001) and (010) planes causes planar defects and causes changes in local electronic structure. This change can cause insulating barriers locally which contribute to the large dielectric values irrespective of processing. The combination of insulating barriers, defects and displacements caused by twinning have been attributed to the generation of large dielectric constant in CCTO. To examine some of these arguments some researchers replaced Ca with other elements and evaluated this concept. In this study we present the synthesis and characterization of Ga2/3Cu3Ti4O12-xNx (GCTON) material. This provides both distortion due to atomic size difference and defects due to insertion of nitrogen. The morphology of the compound was determined to show that processing has tremendous effect on the dielectric values. The resistivity of GCTON was several order higher than CCTO and dielectric constant was higher than 10,000.

Gill, Puneet↗

Power Electronics Being Developed for Deep Space Cryogenic Applications

Electronic circuits and systems designed for deep space missions need to operate reliably and efficiently in harsh environments that include very low temperatures. Spacecraft that operate in such cold environments carry a large number of heaters so that the ambient temperature for the onboard electronics remains near 20 C. Electronics that can operate at cryogenic temperatures will simplify system design and reduce system size and weight by eliminating the heaters and their associated structures. As a result, system development and launch cost will be reduced. At the NASA Glenn Research Center, an ongoing program is focusing on the development of power electronics geared for deep space low-temperature environments. The research and development efforts include electrical components design, circuit design and construction, and system integration and demonstration at cryogenic temperatures. Investigations are being carried out on circuits and systems that are targeted for use in NASA missions where low temperatures will be encountered: devices such as ceramic and tantalum capacitors, metal film resistors, semiconductor switches, magnetics, and integrated circuits including dc/dc converters, operational amplifiers, voltage references, and motor controllers. Test activities cover a wide range of device and circuit performance under simple as well as complex test conditions, such as multistress and thermal cycling. The effect of low-temperature conditions on the switching characteristics of an advanced silicon-on-insulator field effect transistor is shown. For gate voltages (VGS) below 2.6 V, drain currents at -190 C are lower than drain currents at room temperature (20 C).

Patterson, Richard L.↗

Micro-Horn Arrays for Ultrasonic Impedance Matching

Thin-layered structures containing arrays of micromachined horns, denoted solid micro-horn arrays (SMIHAs), have been conceived as improved means of matching acoustic impedances between ultrasonic transducers and the media with which the transducers are required to exchange acoustic energy. Typically, ultrasonic transducers (e.g., those used in medical imaging) are piezoelectric or similar devices, which produce small displacements at large stresses. However, larger displacements at smaller stresses are required in the target media (e.g., human tissues) with which acoustic energy is to be exchanged. Heretofore, efficiencies in transmission of acoustic energy between ultrasonic transducers and target media have been severely limited because substantial mismatches of acoustic impedances have remained, even when coupling material layers have been interposed between the transducers and the target media. In contrast, SMIHAs can, in principle, be designed to effect more nearly complete acoustic impedance matching, leading to power transmission efficiencies of 90 percent or even greater. The SMIHA concept is based on extension, into the higher-frequency/ lower-wavelength ultrasonic range, of the use of horns to match acoustic impedances in the audible and lower-frequency ultrasonic ranges. In matching acoustic impedance in transmission from a higher-impedance acoustic source (e.g., a piezoelectric transducer) and a lowerimpedance target medium (e.g., air or human tissue), a horn acts as a mechanical amplifier. The shape and size of the horn can be optimized for matching acoustic impedance in a specified frequency range. A typical SMIHA would consist of a base plate, a face plate, and an array of horns that would constitute pillars that connect the two plates (see figure). In use, the base plate would be connected to an ultrasonic transducer and the face plate would be placed in contact with the target medium. As at lower frequencies, the sizes and shapes of the pillars could be tailored for impedance matching in a specified ultrasonic frequency range. In a design that would be simplest to implement by micromachining, the horns would have constant cross-sectional areas as shown in the upper part of the figure. In this case, the dimensions of the horns could be chosen on the basis of a Mason equivalent-circuit model (a simplified model, well-known in the piezoelectric-transducer art, in which the electrical and mechanical dynamics, including electromechanical couplings, are expressed as electrical circuit elements that can include inductors, capacitors, and lumped-parameter complex impedances.) In a more complex, more nearly optimum design, the cross-sectional area of each horn would be either stepped or made to vary as a continuous function of through-the thickness position, as shown in the lower part of the figure.

Rao, Shanti↗

Accelerated Aging in Electrolytic Capacitors for Prognostics

The focus of this work is the analysis of different degradation phenomena based on thermal overstress and electrical overstress accelerated aging systems and the use of accelerated aging techniques for prognostics algorithm development. Results on thermal overstress and electrical overstress experiments are presented. In addition, preliminary results toward the development of physics-based degradation models are presented focusing on the electrolyte evaporation failure mechanism. An empirical degradation model based on percentage capacitance loss under electrical overstress is presented and used in: (i) a Bayesian-based implementation of model-based prognostics using a discrete Kalman filter for health state estimation, and (ii) a dynamic system representation of the degradation model for forecasting and remaining useful life (RUL) estimation. A leave-one-out validation methodology is used to assess the validity of the methodology under the small sample size constrain. The results observed on the RUL estimation are consistent through the validation tests comparing relative accuracy and prediction error. It has been observed that the inaccuracy of the model to represent the change in degradation behavior observed at the end of the test data is consistent throughout the validation tests, indicating the need of a more detailed degradation model or the use of an algorithm that could estimate model parameters on-line. Based on the observed degradation process under different stress intensity with rest periods, the need for more sophisticated degradation models is further supported. The current degradation model does not represent the capacitance recovery over rest periods following an accelerated aging stress period.

Celaya, Jose R.↗

Progress in Development of Improved Ion-Channel Biosensors

Further improvements have recently been made in the development of the devices described in Improved Ion-Channel Biosensors (NPO-30710), NASA Tech Briefs, Vol. 28, No. 10 (October 2004), page 30. As discussed in more detail in that article, these sensors offer advantages of greater stability, greater lifetime, and individual electrical addressability, relative to prior ion-channel biosensors. In order to give meaning to a brief description of the recent improvements, it is necessary to recapitulate a substantial portion of the text of the cited previous article. The figure depicts one sensor that incorporates the recent improvements, and can be helpful in understanding the recapitulated text, which follows: These sensors are microfabricated from silicon and other materials compatible with silicon. Typically, the sensors are fabricated in arrays in silicon wafers on glass plates. Each sensor in the array can be individually electrically addressed, without interference with its neighbors. Each sensor includes a well covered by a thin layer of silicon nitride, in which is made a pinhole for the formation of a lipid bilayer membrane. In one stage of fabrication, the lower half of the well is filled with agarose, which is allowed to harden. Then the upper half of the well is filled with a liquid electrolyte (which thereafter remains liquid) and a lipid bilayer is painted over the pinhole. The liquid contains a protein that forms an ion channel on top of the hardened agarose. The combination of enclosure in the well and support by the hardened agarose provides the stability needed to keep the membrane functional for times as long as days or even weeks. An electrode above the well, another electrode below the well, and all the materials between the electrodes together constitute a capacitor. What is measured is the capacitive transient current in response to an applied voltage pulse. One notable feature of this sensor, in comparison with prior such sensors, is a relatively thick dielectric layer between the top of the well and the top electrode. This layer greatly reduces the capacitance of an aperture across which the ion channels are formed, thereby increasing the signal-to-noise ratio. The use of a relatively large aperture with agarose support makes it possible to form many ion channels instead of only one, thereby further increasing the signal-to-noise ratio and effectively increasing the size of the available ionic reservoir. The relatively large reservoir makes it possible to measure AC rather than DC. This concludes the recapitulation from the cited previous article.

Nadeau, Jay L.↗

Disruptive Chemical Approach to Modify Perovskites for Chemical and Biological Sensors

We have been investigating CaCu3Ti4O12 class of perovskites for variety of applications due to its very large dielectric constant. Several mechanisms have been proposed for the existence of the high dielectric constant based on grain boundaries and oxygen deficiencies. We will report the results of the effects of monovalent substitution to replace calcium. This will alter the size to distort the perovskite structure. In addition, we used this system as a sensor for organic agents. There were very large changes in dielectric constant and resistivity indicating this system as a very good sensor material.

Perovskites↗

Development of a Battery-Free Solar Refrigerator

Recent technology developments and a systems engineering design approach have led to the development of a practical battery-free solar refrigerator as a spin-off of NASA's aerospace refrigeration research. Off-grid refrigeration is a good application of solar photovoltaic (PV) power if thermal storage is incorporated and a direct connection is made between the cooling system and the PV panel. This was accomplished by integrating water as a phase-change material into a well insulated refrigerator cabinet and by developing a microprocessor based control system that allows direct connection of a PV panel to a variable speed compressor. This second innovation also allowed peak power-point tracking from the PV panel and elimination of batteries from the system. First a laboratory unit was developed to prove the concept and then a commercial unit was produced and deployed in a field test. The laboratory unit was used to test many different configurations including thermoelectric, Stirling and vapor compression cooling systems. The final configuration used a vapor compression cooling cycle, vacuum insulation, a passive condenser, an integral evaporator/ thermal storage tank, two 77 watt PV panels and the novel controller mentioned above. The system's only moving part was the variable speed BD35 compressor made by Danfoss. The 365 liter cabinet stayed cold with as little as 274 watt-hours per day average PV power. Battery-free testing was conducted for several months with very good results. The amount of thermal storage, size of compressor and power of PV panels connected can all be adjusted to optimize the design for a given application and climate. In the commercial unit, the high cost of the vacuum insulated refrigerator cabinet and the stainless steel thermal storage tank were addressed in an effort to make the technology commercially viable. This unit started with a 142 liter, mass-produced chest freezer cabinet that had the evaporator integrated into its inner walls. Its compressor was replaced with a Danfoss DC compressor slightly larger than the one used in the laboratory unit. The control system was integrated onto a single electronics card and packaged with its starting capacitors. The water for thermal storage was placed behind a liner that was made to fit inside the original factory liner. The original condenser was also augmented with additional surface area to improve performance. PV panels with a total rated power of 180 watts were used. The unit was tested with very successful results in an outside ambient environment, demonstrating its potential for widespread use in many off-grid applications for solar refrigeration.

Ewert, Michael K.↗

Method and Circuit for In-Situ Health Monitoring of Solar Cells in Space

This innovation represents a method and circuit realization of a system designed to make in-situ measurements of test solar-cell operational parameters on orbit using readily available high-temperature and high-ionizing-radiation- tolerant electronic components. This innovation enables on-orbit in-situ solar-array health monitoring and is in response to a need recognized by the U.S. Air Force for future solar arrays for unmanned spacecraft. This system can also be constructed out of commercial-grade electronics and can be embedded into terrestrial solar power system as a diagnostics instrument. This innovation represents a novel approach to I-V curve measurement that is radiation and temperature hard, consumes very few system resources, is economical, and utilizes commercially available components. The circuit will also operate at temperatures as low as 55 C and up to +225 C, allowing it to reside close to the array in direct sunlight. It uses a swept mode transistor functioning as a resistive load while utilizing the solar cells themselves as the biasing device, so the size of the instrument is small and there is no danger of over-driving the cells. Further, this innovation utilizes nearly universal spacecraft bus resources and therefore can be readily adapted to any spacecraft bus allowing for ease of retrofit, or designed into new systems without requiring the addition of infrastructure. One unique characteristic of this innovation is that it effects the measurement of I-V curves without the use of large resistor arrays or active current sources normally used to characterize cells. A single transistor is used as a variable resistive load across the cell. This multi-measurement instrument was constructed using operational amplifiers, analog switches, voltage regulators, MOSFETs, resistors, and capacitors. The operational amplifiers, analog switches, and voltage regulators are silicon-on-insulator (SOI) technology known for its hardness to the effects of ionizing radiation. The SOI components used can tolerate temperatures up to 225 C, which gives plenty of thermal headroom allowing this circuit to perhaps reside in the solar cell panel itself where temperatures can reach over 100 C.

Krasowski, Michael J.↗

Low Cost Micro-Spectrometer for Resource Mapping on Mars

Scientific measurements within craters and along steep embankments on Mars pose extreme challenges since astronauts and rovers cannot access them. However, these areas offer the potential for thegreatest scientific return. NASA Langley Research Center (LaRC) has invented a deployable wireless micro-spectrometer [1-13] capable of accessing thosechallenging areas and, using telemetry, send measurements to a receiver safely outside those extreme environments. A prototype of the micro-spectrometer concept was fabricated and successfullytested for measurement of dopamine as a neural probe [14]. The bullet-sized micro-spectrometer concept can be designed for deployment by an astronaut, a rover, an aerial drone, or a lander, and the measurements broadcasted back to a receiver [13,15,16]. This device can also be installed on rovertires, under the astronaut’s boots, or a cane stick. The bullet-like consumable micro-spectrometer can penetrate soil to spectrally identify the components ofthe soil, such as water or minerals. The signals of the soil assay data are transmitted to a mother station through a telemetry system. The LaRC developed micro-spectrometer bullet consists of micro-spectrometer optics with an all imbedded burst-mode LED UV light source, a super-capacitor with control electronics, and telemetry electronics. Prototypes have been fabricated to demonstrate spectral assay of soil components. Further maturation of this technology would be necessary for demonstration on Mars. Future work includes a potential R&D program that includes other NASA Centers and industry partners interested in developing a business case that requires knowledge of the locations of extraterrestrial ice, for instance.

micro-spectrometer, mineral assay, resource mappin↗

Hypervelocity impact facility for simulating materials exposure to impact by space debris

The Space Power Institute at Auburn University has constructed an electromagnetically driven particle accelerator for simulating the effects of space debris on the materials for use in advanced spacecraft. The facility consists of a capacitively driven accelerator section, a drift tube and a specimen impact chamber. The drift tube is sufficiently long that all electrical activity has ceased prior to impact in the specimen chamber. The impact chamber is large enough to allow a wide range of specimen geometries, ranging from small coupons to active portions of advanced spacecraft. The electric drive for the accelerator consists of a 67 kJ, 50 k capacitor bank arranged in a low inductance configuration. The bank is discharged through an aluminum armature/plastic ablator plate/projectile load in roughly 1.2 microsec. The evaporation of the ablaitor plate produces an expanding gas slug, mostly H2, traveling at a velocity of some 60 km/sec. Because of the pressure and local density, the expanding gas cloud accelerates projectiles due to plasma drag. To date, we have utilized projectiles consisting of 100 micron SiC, 100 and 400 micron Al2O3, 100 and 145 micron olivines. Since many particles are accelerated in a given experiment, there is a range of velocities for each shot as well as some particle breakup. Advanced diagnostics techniques allow determination of impact coordinates, velocity, and approximate size for as many as 50 individual impacts in a given experiment. We routinely measure velocities in the range 1-15 km/sec. We have used this facility to study a variety of impact generated phenomena on coated surfaces, both paint and plastic, thermal blanket material, solar cell arrays, and optical materials such as glass and quartz lenses. The operating characteristics of the gun, the advanced diagnostic scheme, and the results of studies of crater morphology are described in detail. Projectile residue analysis, as a function of impact velocity for the materials listed above, is also discussed. Wherever possible, these results are compared to those obtained by LDEF investigators and future experiments suggested which could help to explain unique features associated with LDEF impacts.

Rose, M. Frank↗

Long term microparticle impact fluxes on LDEF determined from optical survey of Interplanetary Dust Experiment (IDE) sensors

Many of the IDE metal-oxide-silicon (MOS) capacitor-discharge impact sensors remained active during the entire Long Duration Exposure Facility (LDEF) mission. An optical survey of impact sites on the active surfaces of these sensors has been extended to include all sensors from the low-flux sides of LDEF (i.e. the west or trailing side, the earth end, and the space end) and 5-7 active sensors from each LDEF's high-flux sides (i.e. the east or leading side, the south side, and the north side). This survey was facilitated by the presence of a relatively large (greater than 50 micron diameter) optical signature associated with each impact site on the active sensor surfaces. Of the approximately 4700 impacts in the optical survey data set, 84% were from particles in the 0.5 to 3 micron size range. An estimate of the total number of hypervelocity impacts on LDEF from particles greater than 0.5 micron diameter yields a value of approximately 7 x 10(exp 6). Impact feature dimensions for several dozen large craters on MOS sensors and germanium witness plates are also presented. Impact fluxes calculated from the IDE survey data closely matched surveys of similar size impacts (greater than or equal to 3 micron diameter craters in Al, or marginal penetrations of a 2.4 micron thick Al foil) by other LDEF investigators. Since the first year IDE data were electronically recorded, the flux data could be divided into three long term time periods: the first year, the entire 5.8 year mission, and the intervening 4.8 years (by difference). The IDE data show that there was an order of magnitude decrease in the long term microparticle impact flux on the trailing side of LDEF, from 1.01 to 0.098 x 10(exp -4) m(exp 2)/s, from the first year in orbit compared to years 2-6. The long term flux on the leading edge showed an increase from 8.6 to 11.2 x 10(exp -4) m(exp -2)/s over this same time period. (Short term flux increases up to 10,000 times the background rate were recorded on the leading side during LDEF's first year in orbit.) The overall east/west ratio was 44, but during LDEF's first year in orbit the ratio was 8.5, and during years 2-6 the ratio was 114. Long term microparticle impact fluxes on the space end decreased from 1.12 to 0.55 x 10(exp -4) m(exp -2)/s from the first year in orbit compared to years 2-6. The earth end showed the opposite trend with an increase from 0.16 to 0.38 x 10(exp -4) m(exp -2)/s. Fluxes on rows 6 and 12 decreased from 6.1 to 3.4 and 6.7 to 3.7 x 10(exp -4) m(exp -2)/s, respectively, over the same time periods. This resulted in space/earth microparticle impact flux ratios of 7.1 during the first year and 1.5 during years 2-6, while the south/north, space/north and space/south ratios remained constant at 1.1, 0.16 and 0.17, respectively, during the entire mission. This information indicates the possible identification of long term changes in discrete microparticle orbital debris component contributions to the total impact flux experienced by LDEF. A dramatic decrease in the debris population capable of striking the trailing side was detected that could possibly be attributed to the hiatus of western launch activity experienced from 1986-1989. A significant increase in the debris population that preferentially struck the leading side was also observed and could possibly be attributed to a single breakup event that occurred in September of 1986. A substantial increase in the microparticle debris population that struck the earth end of LDEF, but not the space end, was also detected and could possibly be the result of a single breakup event at low altitude. These results point to the importance of including discrete orbital debris component contribution changes in flux models in order to achieve accurate predictions of the microparticle environment that a particular spacecraft will experience in earth orbit. The only reliable, verified empirical measurements of these changes are reported in this paper. Further time-resolved in-situ measurements of these debris populations are needed to accurately assess model predictions and mitigation practices.

Simon, C. G.↗

Improved Signal Chains for Readout of CMOS Imagers

An improved generic design has been devised for implementing signal chains involved in readout from complementary metal oxide/semiconductor (CMOS) image sensors and for other readout integrated circuits (ICs) that perform equivalent functions. The design applies to any such IC in which output signal charges from the pixels in a given row are transferred simultaneously into sampling capacitors at the bottoms of the columns, then voltages representing individual pixel charges are read out in sequence by sequentially turning on column-selecting field-effect transistors (FETs) in synchronism with source-follower- or operational-amplifier-based amplifier circuits. The improved design affords the best features of prior source-follower-and operational- amplifier-based designs while overcoming the major limitations of those designs. The limitations can be summarized as follows: a) For a source-follower-based signal chain, the ohmic voltage drop associated with DC bias current flowing through the column-selection FET causes unacceptable voltage offset, nonlinearity, and reduced small-signal gain. b) For an operational-amplifier-based signal chain, the required bias current and the output noise increase superlinearly with size of the pixel array because of a corresponding increase in the effective capacitance of the row bus used to couple the sampled column charges to the operational amplifier. The effect of the bus capacitance is to simultaneously slow down the readout circuit and increase noise through the Miller effect.

Pain, Bedabrata↗

Assessment of velocity/trajectory measurement technologies during a particle capture event

Since the early 1960s, the means to measure the time of flight (TOF) of dust grain within a mechanical detection array has existed, first in the laboratory and then in space experiments. Laboratory hypervelocity dust particle accelerators have used electrostatic detection of charge on accelerated particles for TOF and particle mass detections. These laboratory studies have led to the development of ultra-thin-film sensors that have been used for TOF measurements in dust particle space experiments. The prototypes for such devices were ultra-thin-film capacitors that were used in the OGO series of satellites. The main goal of the experimental work to be described is the development of the capability to determine the velocity vector or trajectory of a dust grain traversing an integrated dust detection array. The results of these studies have shown that the capability of detecting the charge liberated by hypervelocity dust grains with diameters in the micrometer range can be detected. Based on these results, detection systems have been designed to provide a precise analysis of the physical and dynamic properties of micrometer and submicrometer dust grains, namely the design verification unit (DVU). Through unique combinations of in situ detection systems, direct measurements of particle surface charge, velocity, momentum, kinetic energy, and trajectory have been achieved. From these measurements, the remaining physical parameters of mass, size, and density can be determined.

Tanner, William G.↗

Electronic Components and Circuits for Extreme Temperature Environments

Planetary exploration missions and deep space probes require electrical power management and control systems that are capable of efficient and reliable operation in very low temperature environments. Presently, spacecraft operating in the cold environment of deep space carry a large number of radioisotope heating units in order to maintain the surrounding temperature of the on-board electronics at approximately 20 C. Electronics capable of operation at cryogenic temperatures will not only tolerate the hostile environment of deep space but also reduce system size and weight by eliminating or reducing the radioisotope heating units and their associate structures; thereby reducing system development as well as launch costs. In addition, power electronic circuits designed for operation at low temperatures are expected to result in more efficient systems than those at room temperature. This improvement results from better behavior and tolerance in the electrical and thermal properties of semiconductor and dielectric materials at low temperatures. The Low Temperature Electronics Program at the NASA Glenn Research Center focuses on research and development of electrical components, circuits, and systems suitable for applications in the aerospace environment and deep space exploration missions. Research is being conducted on devices and systems for reliable use down to cryogenic temperatures. Some of the commercial-off-the-shelf as well as developed components that are being characterized include switching devices, resistors, magnetics, and capacitors. Semiconductor devices and integrated circuits including digital-to-analog and analog-to-digital converters, DC/DC converters, operational amplifiers, and oscillators are also being investigated for potential use in low temperature applications. An overview of the NASA Glenn Research Center Low Temperature Electronic Program will be presented in this paper. A description of the low temperature test facilities along with selected data obtained through in-house component and circuit testing will also be discussed. Ongoing research activities that are being performed in collaboration with various organizations will also be presented.

Patterson, Richard L.↗