Search NASA⌕ Search

SEARCH · Search NASA

Results for “circulation test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

HTGR Multiphysics Application Drivers FY26 Updates

This report summarizes FY26 progress under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program's high-temperature gas-cooled reactor (HTGR) application driver work, covering a wide range of activities such as code validation and multi-physics code assessment. 1) A detailed SAM model of the High-Temperature Engineering Test Reactor (HTTR) was developed using a unique-block grouping approach, with an extended parallel thermal network method to capture block-to-block conduction and radiation heat transfer, and applied to steady-state simulations of the HTTR 30~MW and 9~MW cases. 2) In another activity, SAM's newly implemented multi-component gas flow model was validated against the Natural convection Shutdown heat removal Test Facility (NSTF) argon ingress experiment, correctly capturing the density-driven suppression and thermal recovery of natural circulation observed when argon is introduced into the air-cooled Reactor Cavity Cooling System (RCCS) loop. 3) For the OECD/NEA High Temperature Test Facility (HTTF) benchmark, we co-led the international benchmark activities as well as the OECD/NEA final benchmark report to be released at the end of this year. 4) Finally, the coupled Griffin-SAM modeling capability for pebble-bed HTGRs was advanced by verifying the Griffin neutronics solution against Serpent Monte Carlo for a realistic non-uniform temperature distribution, resolving several deficiencies in the SAM-to-Griffin temperature transfer scheme, and enabling distinct fuel kernel, moderator, and coolant temperatures for cross section feedback. These new features were demonstrated in a PBR load-following transient.

Lee, Alvin↗

Convolutional Neural Network–Aided Temperature Field Reconstruction: An Innovative Method for Advanced Reactor Monitoring

In this study, the capabilities of a physics-informed convolutional neural network (CNN) for reconstructing the temperature field from a limited set of measurements taken at the boundaries of internal flows are demonstrated. Such an approach enables the development of less invasive monitoring methods for real-time plant diagnostics. As a test case, a Molten Salt Fast Reactor (MSFR) design was selected. This circulating fuel reactor has received interest from both scientific and industrial communities due to its intrinsic safety and sustainability. Molten salt flows in such reactors, however, can present highly localized temperature peaks that can induce significant thermal stresses onto the vessel walls. At these local maxima, the salt temperature may exceed a thousand kelvins, which makes a direct measurement challenging or even unfeasible. The proposed CNN algorithm allows one to detect indirectly such discontinuities through an accurate, albeit indirect, temperature measurement method during reactor operation. The datasets employed to train and test the machine learning models in the present work were generated with Nek5000, a computational fluid dynamics (CFD) code developed at Argonne National Laboratory. The CNN algorithm is trained with CFD results that span a set of MSFR operational power and flow ranges. Here, to demonstrate the efficacy of the algorithm, predictions are made for test cases contained within the training range but for which the CFD data were not used when training. Results demonstrate that the proposed technique properly characterizes temperature peaks and distributions within the domain for a broad range of scenarios.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Baseline for Global Weather and Climate Simulations at 1 km Resolution

In an attempt to advance the understanding of the Earth's weather and climate by representing deep convection explicitly, we present a global, four-month simulation (November 2018 to February 2019) with ECMWF's hydrostatic Integrated Forecasting System (IFS) at an average grid spacing of 1.4 km. The impact of explicitly simulating deep convection on the atmospheric circulation and its variability is assessed by comparing the 1.4 km simulation to the equivalent well-tested and calibrated global simulations at 9 km grid spacing with and without parametrized deep convection. The explicit simulation of deep convection at 1.4 km results in a realistic large-scale circulation, better representation of convective storm activity, and stronger convective gravity wave activity when compared to the 9 km simulation with parametrized deep convection. Comparison of the 1.4 km simulation to the 9 km simulation without parametrized deep convection shows that switching off deep convection parametrization at a too coarse resolution (i.e., 9 km) generates too strong convective gravity waves. Based on the limited statistics available, improvements to the Madden-Julian Oscillation or tropical precipitation are not observed at 1.4 km, suggesting that other Earth system model components and/or their interaction are important for an accurate representation of these processes and may well need adjusting at deep convection resolving resolutions. Overall, the good agreement of the 1.4 km simulation with the 9 km simulation with parametrized deep convection is remarkable, despite one of the most fundamental parametrizations being turned off at 1.4 km resolution and despite no adjustments being made to the remaining parametrizations.

54 ENVIRONMENTAL SCIENCES↗

Testing and Simulation of an Updated Cartridge Loop Vehicle

The Versatile Test Reactor (VTR) is a sodium-cooled, fast-spectrum test reactor that is being developed in the United States and will support a variety of irradiation test vehicle configurations, including cartridge loops. This work includes out-of-pile experimental results from a single-phase, natural circulation cartridge loop vehicle with geometry relevant to VTR irradiation sites, as well as comparisons between the experimental results and results predicted using the TRAC/RELAP Advanced Computational Engine (TRACE) modeling tool. The experiments were conducted in the thermosyphon test loop (TSTL) facility at Oak Ridge National Laboratory. Comparisons are also made between the current experimental data and results from natural circulation experiments previously conducted in the TSTL in a cartridge vehicle that is similar in design but has smaller flow areas. This cartridge vehicle and the experimental program were developed to add to the single-phase, natural circulation data collected in the previous iteration of the cartridge loop design, which supports future irradiation experiments and adds to a database that is useful for validating computer models. Comparisons of experimental results to TRACE model predictions is a pertinent step in validating the computational tool for supporting future irradiation experiment design and safety calculations, and comparisons to previous cartridge loop results highlight the impact of the design changes made to the test vehicle. The experiments conducted include several steady state tests and transients, including power ramp, loss of offsite power, and loss of external flow scenarios. This work shows that TRACE can accurately predict temperatures and flow conditions in the cartridge loop and the updated vehicle design achieves higher mass flow rates at the same steady state power levels.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evidence of a South Asian Proto‐Monsoon During the Oligocene‐Miocene Transition

Abstract The geological history of the South Asian monsoon (SAM) before the Pleistocene is not well‐constrained, primarily due to a lack of available continuous sediment archives. Previous studies have noted an intensification of SAM precipitation and atmospheric circulation during the middle Miocene (∼14 Ma), but no records are available to test how the monsoon changed prior to this. In order to improve our understanding of monsoonal evolution, geochemical and sedimentological data were generated for the Oligocene‐early Miocene (30–20 Ma) from Indian National Gas Hydrate Expedition 01 Site NGHP‐01‐01A in the eastern Arabian Sea, at 2,674 m water depth. We find the initial glaciation phase (23.7–23.0 Ma) of the Oligocene‐Miocene transition (OMT) to be associated with an increase in water column ventilation and water mass mixing, suggesting an increase in winter monsoon type atmospheric circulation, possibly driven by a relative southward shift of the intertropical convergence zone. During the latter part of the OMT, or “deglaciation” phase (23.0–22.7 Ma), a long‐term decrease in Mn (suggestive of deoxygenation), increase in Ti/Ca and dissolution of the biogenic carbonate fraction suggest an intensification of a proto‐summer SAM system, characterized by the formation of an oxygen minimum zone in the eastern Arabian Sea and a relative increase of terrigenous material delivered by runoff to the site. With no evidence at this site for an active SAM prior to the OMT we suggest that changes in orbital parameters, as well as possibly changing Tethyan/Himalayan tectonics, caused this step change in the proto‐monsoon system at this intermediate‐depth site.

Beasley, C.↗

Design Status and Experimental Strategy for Initial Molten Salt Irradiation Experiments in HFIR

The development and deployment of molten salt reactor (MSR) technologies require experimental capabilities that can evaluate molten fuel salt behavior and structural material performance under representative irradiation conditions. Although modeling and separate effects testing provide important insight, there remains a critical lack of in-pile data that capture the coupled effects of neutron irradiation, temperature, salt chemistry, and time. Informed by lessons learned from historical MSR programs and recent international irradiation efforts, this report presents a structured approach to addressing existing gaps in molten salt irradiation testing using the High Flux Isotope Reactor (HFIR). A phased irradiation strategy is presented that incrementally increases experimental complexity while managing cost, risk, and facility constraints. The framework progresses from passive, nonfueled static capsule experiments to fueled, instrumented, and ultimately circulating molten salt systems, providing a pathway for materials screening, mechanistic understanding, and qualification-relevant testing. The report defines a near-term Phase 1 passive capsule concept, associated irradiation conditions, and a conceptual post-irradiation examination strategy. Ongoing modeling, out-of-pile testing, and safety analysis activities are described to support continued capability maturation and to enable future phases of molten salt irradiation testing in support of MSR technology deployment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Differential laboratory passaging of SARS-CoV-2 viral stocks impacts the in vitro assessment of neutralizing antibodies

Viral populations in natural infections can have a high degree of sequence diversity, which can directly impact immune escape. However, antibody potency is often tested in vitro with a relatively clonal viral populations, such as laboratory virus or pseudotyped virus stocks, which may not accurately represent the genetic diversity of circulating viral genotypes. This can affect the validity of viral phenotype assays, such as antibody neutralization assays. To address this issue, we tested whether recombinant virus carrying SARS-CoV-2 spike (VSV-SARS-CoV-2-S) stocks could be made more genetically diverse by passage, and if a stock passaged under selective pressure was more capable of escaping monoclonal antibody (mAb) neutralization than unpassaged stock or than viral stock passaged without selective pressures. We passaged VSV-SARS-CoV-2-S four times concurrently in three cell lines and then six times with or without polyclonal antiserum selection pressure. All three of the monoclonal antibodies tested neutralized the viral population present in the unpassaged stock. The viral inoculum derived from serial passage without antiserum selection pressure was neutralized by two of the three mAbs. However, the viral inoculum derived from serial passage under antiserum selection pressure escaped neutralization by all three mAbs. Deep sequencing revealed the rapid acquisition of multiple mutations associated with antibody escape in the VSV-SARS-CoV-2-S that had been passaged in the presence of antiserum, including key mutations present in currently circulating Omicron subvariants. These data indicate that viral stock that was generated under polyclonal antiserum selection pressure better reflects the natural environment of the circulating virus and may yield more biologically relevant outcomes in phenotypic assays. Thus, mAb assessment assays that utilize a more genetically diverse, biologically relevant, virus stock may yield data that are relevant for prediction of mAb efficacy and for enhancing biosurveillance.

60 APPLIED LIFE SCIENCES↗

Are Atmospheric Models Too Cold in the Mountains? The State of Science and Insights from the SAIL Field Campaign

Mountains play an outsized role in water resource availability, and the amount and timing of water they provide depend strongly on temperature. To that end, we ask the question: How well are atmospheric models capturing mountain temperatures? We synthesize results showing that high-resolution, regionally relevant climate models produce 2-m air temperature (T2m) measurements colder than what is observed (a “cold bias”), particularly in snow-covered midlatitude mountain ranges during winter. We find common cold biases in 44 studies across global mountain ranges, including single-model and multimodel ensembles. We explore the factors driving these biases and examine the physical mechanisms, data limitations, and observational uncertainties behind T2m. Our analysis suggests that the biases are genuine and not due to observation sparsity or resolution mismatches. Cold biases occur primarily on mountain peaks and ridges, whereas valleys are often warm biased. Our literature review suggests that increasing model resolution does not clearly mitigate the bias. By analyzing data from the Surface Atmosphere Integrated Field Laboratory (SAIL) field campaign in the Colorado Rocky Mountains, we test various hypotheses related to cold biases and find that local wind circulations, longwave (LW) radiation, and surface-layer parameterizations contribute to the T2m biases in this particular location. We conclude by emphasizing the value of coordinated model evaluation and development efforts in heavily instrumented mountain locations for addressing the root cause(s) of T2m biases and improving predictive understanding of mountain climates.

54 ENVIRONMENTAL SCIENCES↗

Are Atmospheric Models Too Cold in the Mountains? The State of Science and Insights from the SAIL Field Campaign

Mountains play an outsized role in water resource availability, and the amount and timing of water they provide depend strongly on temperature. To that end, we ask the question: How well are atmospheric models capturing mountain temperatures? We synthesize results showing that high-resolution, regionally relevant climate models produce 2-m air temperature (T2m) measurements colder than what is observed (a “cold bias”), particularly in snow-covered midlatitude mountain ranges during winter. We find common cold biases in 44 studies across global mountain ranges, including single-model and multimodel ensembles. We explore the factors driving these biases and examine the physical mechanisms, data limitations, and observational uncertainties behind T2m. Our analysis suggests that the biases are genuine and not due to observation sparsity or resolution mismatches. Cold biases occur primarily on mountain peaks and ridges, whereas valleys are often warm biased. Our literature review suggests that increasing model resolution does not clearly mitigate the bias. By analyzing data from the Surface Atmosphere Integrated Field Laboratory (SAIL) field campaign in the Colorado Rocky Mountains, we test various hypotheses related to cold biases and find that local wind circulations, longwave (LW) radiation, and surface-layer parameterizations contribute to the T2m biases in this particular location. We conclude by emphasizing the value of coordinated model evaluation and development efforts in heavily instrumented mountain locations for addressing the root cause(s) of T2m biases and improving predictive understanding of mountain climates.

54 ENVIRONMENTAL SCIENCES↗

Single-phase, natural circulation annular flow measurements for cartridge loop irradiation experiments

The nuclear industry is increasingly considering cartridge-style experiments for irradiation testing of advanced reactor fuels and materials under flowing conditions. Cartridge loops do not require the extensive support infrastructure that are necessary for external flow loops and minimize the possibility of coolant solidification over the long distance from the reactor to the external facilities. However, there is a general lack of quality flow data for internally heated fluids in an annular configuration representative of a cartridge-type irradiation experiment, particularly one with natural circulation. To address this data need, a series of experiments was conducted to measure the natural circulation flow rates of pressurized water in a sealed, internally heated vessel with annular flow conditions that represent a molten salt or sodium cartridge loop. Temperatures and flow rates were measured under steady-state and transient conditions. Here, this paper describes the facility, methods, and results of the experiments, including the determination of nondimensional parameters. A simple 1D model of the natural convection flow rates agrees well with the experimental results. Applying this model to simulate a liquid salt cartridge experiment predicts that natural circulation flow might be able to provide liquid salt Reynolds numbers similar to those of some molten salt reactor concepts at relevant power densities.

42 ENGINEERING↗

High-Temperature Heat Transfer Fluid Circulator for Concentrating Solar Power Systems

Concentrating Solar Power (CSP) plants with Thermal Energy Storage (TES), require compressors capable of circulating supercritical carbon dioxide (sCO2) heat transfer fluids (HTFs) at temperatures from 500 to 700+°C and pressures from 8 to 25 MPa (80 to 250 Bar or 1160 to 3626 psia) in order to achieve thermal-to-electric efficiencies >50%. A review of papers relating to SCO2 compressors reveals that in almost every case the conditions being considered either allow for cooling of the SCO2 working fluid or are considering operating conditions close to the critical point at a temperature and pressure of approximately 31°C and 1070 psi). While the technology reported in these papers is relevant to most turbomachinery, the current CSP gas pathway circulator operating pressures are well above the CO2 critical point and do not allow for cooling of the main HTF flow. The purpose of this paper was to describe the key system issues affecting the design of a HTF circulator that could be scaled from a small size research and proof of concept circulator compressor to sizes supporting power plants producint upwards of 100 to 300 Mega Watts of electrical power. Due to the high temperatures and pressures the research scale HTF circulator was designed to be hermetically sealed to prevent leakage of the super critical carbon dioxide to the environment. In order to achieve hermetic sealing the drive motor and centrifugal impeller were fully integrated in a single shaft system configuration. From a preliminary assessment of compression power as a function of operating speed and impeller diameter it was determined that a smaller, higher speed impeller would result in a more efficient circulator. However, due to the high pressure and corresponding density of the sCO2 coupled with high operating speeds, large windage losses (i.e., viscous drag on the high speed rotating shaft) would occur which could result in a substantial reduction in efficiency of the system. Therefore tradoff studies were complerted to identify the operating speeds and system component sizes to achieve high efficiency. Based on the trade studies, the final design was a 55 mm diamter compressor impeller operating at speeds to 85,000 rpm. The unit will be built and tested in the future. Key Words: Super Critical Carbon Dioxide, Heat Transfer Fluid, Turbomachinery, Compressor, Circulator, Critical Point, Concentrating Solar Power, Solar Energy

Super Critical Carbon Dioxide, Heat Transfer Fluid↗

High-Temperature Heat Transfer Fluid Circulator for Concentrating Solar Power Systems

A high temperature Heat Transfer Fluid circulator compressor with wide turn down ratio aerodynamic performance was designed, fabricated and tested for application with high pressure super Critical CO2 fluid capable of temperatures and pressures to >750°C and 25 MPa respectively. The modular system decoupled the drive motor system from an independent compressor shaft to provide thermal isolation between the high temperature compressor shaft and the lower temperature capable motor elements. While the thermal management approach appears to be viable there are potential losses in the secondary cooling flows that need to be taken into account and fine-tuned during operation in order to achieve desired overall system efficiencies. The system was also shown to be viable and dynamically stable throughout the entire operating speed range, thereby validating the overall system configuration and structural design approach used. Finally, while it was not possible to achieve specific PTC-10 test points, the compressor performance tests provide sufficient data to indicate that the compressor has the ability to achieve the required performance in practice. The two key factors affecting compressor design and cost are the maximum expected temperature and pressure. The maximum allowable temperatures for current state-of-the-art (SOA) motor driven compressor technology is limited to of approximately 150-200°C, but inlet temperatures >750 °C may be encountered. While the optimal efficiency of compression is in the transcritical region, some concepts require inlet pressures to 225 bar.

14 SOLAR ENERGY↗

High-Temperature Heat Transfer Fluid Circulator for Concentrating Solar Power Systems How Mohawk and Velo3Dare Printing the Future of Energy

A high temperature Heat Transfer Fluid circulator compressor with wide turn down ratio aerodynamic performance was designed, fabricated and tested for application with high pressure super Critical CO2 fluid capable of temperatures and pressures to >750°C and 25 MPa respectively. The modular system decoupled the drive motor system from an independent compressor shaft to provide thermal isolation between the high temperature compressor shaft and the lower temperature capable motor elements. While the thermal management approach appears to be viable there are potential losses in the secondary cooling flows that need to be taken into account and fine-tuned during operation in order to achieve desired overall system efficiencies. The system was also shown to be viable and dynamically stable throughout the entire operating speed range, thereby validating the overall system configuration and structural design approach used. Finally, while it was not possible to achieve specific PTC-10 test points, the compressor performance tests provide sufficient data to indicate that the compressor has the ability to achieve the required performance in practice. The two key factors affecting compressor design and cost are the maximum expected temperature and pressure. The maximum allowable temperatures for current state-of-the-art (SOA) motor driven compressor technology is limited to of approximately 150-200°C, but inlet temperatures >750 °C may be encountered. While the optimal efficiency of compression is in the transcritical region, some concepts require inlet pressures to 225 bar.

14 SOLAR ENERGY↗

Corrosion of 316 L stainless steel under the natural circulation of molten NaCl-MgCl 2 salt

The corrosion behavior of 316 L stainless steel (SS) was studied via the natural circulation of molten eutectic NaCl-MgCl 2 salt through a microloop. The post-corrosion tested 316 L SS microloop sections were characterized with microscopy techniques to determine the microstructural and microchemical changes that occurred at the alloy/salt interface. It was found that 316 L SS showed heterogeneous dissolution at the hot-leg, whereas deposition of corrosion products occurred at the cold-leg. For the first time, experimentally obtained molten salt flow-induced corrosion of 316 L SS results were combined with computational thermodynamic-kinetic models to validate the dissolution and deposition in terms of elemental compositional changes at the alloy/salt interface. The thermodynamic-kinetic modeling predicted that the heterogeneous dissolution of Cr and Fe from the hot-leg section of 316 L SS persisted throughout the salt circulation. The model also estimated that, despite Cr deposition starting earlier than Fe, the total redeposition of Fe is expected to be significantly greater than that of Cr over the circulation of salt. Furthermore, the modeling accurately predicted the subsurface enrichment of Mo which is attributed to the reduced Cr activity and the relatively higher diffusion rate of Mo within the alloy matrix. Here, the agreement between modeling and experimental results confirms that Fe chlorides dissolve at the hot-leg and subsequently deposit at the cold-leg due to activity changes driven by the thermal gradient. By contrast, Cr was not detected in the cold-leg deposits, which is attributed to its weaker temperature dependence on activity, limiting its redeposition under these conditions.

36 - MATERIALS SCIENCE↗

EGS Collab Experiment 2: Earth Model Datasets

The EGS Collab Project performed a series of tests to increase the understanding the response of crystalline rock mass to stimulations and fluid circulation to efficiently implement enhanced geothermal systems (EGS) technologies. The EGS Collab team created two underground testbeds at the Sanford Underground Research Facility (SURF) in Lead SD at a depth of approximately 1.5 km (4850 level) and 1.25 km (4100 level) to examine hydraulic fracturing and hydraulic shearing, respectively. Experiment 2 was designed to examine hydraulic shearing and fluid flow in testbed 2 in amphibolite under a controlled set of stress and fracture conditions. This document summarizes the general geology, natural fractures, and conceptual model(s) of stimulated fracture networks in the testbed 2. The dataset package included here are input and output products associated with Earth Models for the EGS Collab Testbed 2. The earth model datasets are included in the whole package (project) in Leapfrog file format. Also, datasets are given in primary input file format (csv).

15 GEOTHERMAL ENERGY↗

Validation Testing for Molten Chloride Reactor Experiment Equipment Removal and Disposal Techniques

The Molten Chloride Reactor Experiment (MCRE) will be the first reactor featuring a fast-spectrum molten chloride circulating nuclear fuel system in the world. Planning for equipment removal and disposal (ERD) of MCRE has identified several technology gaps due to the unique environment of this nuclear experiment. Some of the gaps arise from the application of existing disassembly and/or sizing methods to novel material forms or in novel configurations. Others arise from unknown material behavior. This paper summarizes proposed test plans for ERD validation experiments to address these complicated or unknown equipment removal procedures. At the Waste Management Symposia in 2024, the Idaho National Laboratory (INL) MCRE ERD team presented the challenges associated with hosting multiple nuclear experiments in series with only brief transition periods between systems. Such difficulties include higher dose rates, the presence of radioisotopes infrequently encountered in reactor decommissioning and radioactive waste management, lack of intrinsic remote-operations infrastructure in the test bed, space constraints in the test bed, and contamination minimization requirements. To address these challenges, remote or semi-remote technologies are planned to be implemented in a non-hot cell environment with limited space availability. The team also discussed how a systems engineering approach is being used for conceptual development and design of equipment removal systems to address these challenges. For example, to reduce constraints for the removal of more difficult components, non-activated, noncontaminated elements are planned to be taken out first where possible. Still, there are complexities associated with the remaining components. In this work, the operational framework for MCRE ERD was reviewed for technical gaps and open questions, and test plans were drafted to address these areas. The tests plans were written for the following categories: vision systems, pipe cutting, drill/grout/filler, flush salt, and miscellaneous, with the miscellaneous group consisting of tests like techniques for removing bearings and reflector bricks. The test plans explore material, infrastructure, and staffing requirements needed for test execution. The test plans additionally focus on the evaluation of success. Determining the outcome of a test is imperative - as these explorative actions have the potential to rearrange or re-scope planned ERD activities. Success criteria identified thus far include required tool output, required area(s), debris production and mitigation, and repeatability. Test plans are an essential aspect of the systems engineering approach to MCRE ERD. They are used as the beginning steps in defining use cases for the ERD system. Performance of the validation tests is expected to begin in the summer of 2025 and will take approximately 9 to 12 months to complete. Execution of these plans will be expedited by specifying test needs ahead of time, facilitating efficient interactions with any subcontractors tasked with running the requested tests. Evaluating the outcomes of these tests will inform MCRE ERD procedures and timing and will also identify additional technical constraints for the MCRE ERD System. This upfront process optimization effort will help the project save time and resources at the end of the experiment.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Eddy covariance towers as sentinels of abnormal radioactive material releases

Ensuring accurate detection and attribution of abnormal releases of radioactive material is critical for protecting human health and safety. Most commonly, such detection is accomplished via active monitoring approaches involving the collection of physical samples. Further, this is labor intensive and limits the temporal and spatial resolution of any detected events to a relatively coarse level. As an alternative first step towards passive monitoring, we developed an approach using eddy flux tower data records to identify signals from a known abnormal release and quantify the extent to which that signal also occurs at other times in the data record. Through two case studies, one of which targeted the Fukushima nuclear disaster and the other targeting an abnormal release event at a radioisotope production facility in Fleurus, Belgium, we tested our approach and identified several potential heretofore unidentified abnormal events that were consistent with atmospheric circulation patterns and/or wind direction from known release sites. Because our approach is relatively simple and is resistant to systematic errors in the observational record, it has broad applicability beyond specific constituents and ecosystem types to identify a wide variety of limited-duration anomalies in flux tower data to ensure human health and industrial safety.

54 ENVIRONMENTAL SCIENCES↗

Code Validation of SAM Using Forced and Natural Circulation Data from NACIE-UP Benchmark

Heavy liquid metals (HLMs) are promising candidates as coolants of Generation IV fast reactors due to their thermophysical properties. In the last decade, experimental work has been proposed as part of research and development efforts to develop such systems. In this context, researchers from the Brasimone Research Center have conducted many experiments using the Natural Circulation Experiment Upgrade (NACIE-UP) facility to study the thermofluid dynamic behavior of HLMs in rod bundle configurations with or without wire wrappers. This facility consists of a rectangular loop operated with lead-bismuth eutectic. Sensors across the loop monitor relevant parameters, i.e. temperatures, heat transfer, and flow conditions. Here, in the present work, we carefully select published data from NACIE-UP to validate the System Analysis Module (SAM), a modern system analysis code developed at Argonne National Laboratory. We developed one SAM model using specifications of the facility geometry and materials existing in relevant papers and reports. On top of that, these references provided the boundary conditions for simulating natural circulation and forced convection experiments in either steady or transient conditions. The SAM model simulates five test cases with diverse operating conditions. Ultimately, the code is proven to predict temperatures and mass flow rates that closely match the experiments. The discrepancies between numerical predictions and diverse transients are limited to a few degrees Celsius, showcasing that SAM is well suited for analyzing nuclear systems relying on HLM coolants.

advanced reactors↗