Search NASA⌕ Search

SEARCH · Search NASA

Results for “contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Spectral gratings-based phase-contrast imaging for materials characterization

Spectral X-ray detectors provide a direct observation of the energy spectrum of a transmitted X-ray beam, both for typical and phase-contrast gratings-based systems. The sensitivity of a gratings-based X-ray system to small-angle deflections from a given particle size is dependent on X-ray energy. Therefore, spectral (energy-sensitive) detectors could be sensitive to particle size, even with a broad spectrum from a commercial X-ray generator. Furthermore, these detectors allow direct observation of how the X-ray spectrum is changing as the beam is passing through an object and gratings, and how this affects grating visibilities used to determine the presence of small-angle deflections. This is a particular issue for higher-energy systems where artifacts from beam hardening are common. We present results exploring the particle-size dependent signatures that are available from a spectral gratings-based phase-contrast X-ray imaging system, and the feasibility of observing them with lab-based, broad-spectrum X-ray generators.

Gilbert, Andrew J.↗

Deep-ultraviolet ptychographic pocket-scope (DART): mesoscale lensless molecular imaging with label-free spectroscopic contrast

The mesoscale characterization of biological specimens has traditionally required compromises between resolution, field-of-view, depth-of-field, and molecular specificity, with most approaches relying on external labels. Here we present the Deep-ultrAviolet ptychogRaphic pockeT-scope (DART), a handheld platform that transforms label-free molecular imaging through intrinsic deep-ultraviolet spectroscopic contrast. By leveraging biomolecules’ natural absorption fingerprints and combining them with lensless ptychographic microscopy, DART resolves down to 308-nm linewidths across centimeter-scale areas while maintaining millimeter-scale depth-of-field. The system’s virtual error-bin methodology effectively eliminates artifacts from limited temporal coherence and other optical imperfections, enabling high-fidelity molecular imaging without lenses. Through differential spectroscopic imaging at deep-ultraviolet wavelengths, DART quantitatively maps nucleic acid and protein distributions with femtogram sensitivity, providing an intrinsic basis for explainable virtual staining. We demonstrate DART’s capabilities through imaging of tissue sections, cytopathology specimens, blood cells, and neural populations, revealing detailed molecular contrast without external labels. The combination of high-resolution molecular mapping and broad mesoscale imaging in a portable platform opens new possibilities from rapid clinical diagnostics, tissue analysis, to biological characterization in space exploration.

60 APPLIED LIFE SCIENCES↗

Increased range and contrast in fog with circularly polarized imaging

Fogs, low lying clouds, and other highly scattering environments pose a challenge for many commercial and national security sensing systems. Current autonomous systems rely on optical sensors for navigation whose performance is degraded by highly scattering environments. In our previous simulation work, we have shown that polarized light can penetrate through a scattering environment such as fog. We have demonstrated that circularly polarized light maintains its initial polarization state better than linearly polarized light, even through large numbers of scattering events and thus ranges. This has recently been experimentally verified by other researchers. In this work, we present the design, construction, and testing of active polarization imagers at short-wave infrared and visible wavelengths. We explore multiple polarimetric configurations for the imagers, focusing on linear and circular polarization states. The polarized imagers were tested at the Sandia National Laboratories Fog Chamber under realistic fog conditions. Here, we show that active circular polarization imagers can increase range and contrast in fog better than linear polarization imagers. We show that when imaging typical road sign and safety retro-reflective films, circularly polarized imaging has enhanced contrast throughout most fog densities/ranges compared to linearly polarized imaging and can penetrate over 15 to 25 m into the fog beyond the range limit of linearly polarized imaging, with a strong dependence on the interaction of the polarization state with the target materials.

47 OTHER INSTRUMENTATION↗

Neutron Imaging Using Grating Interferometry: Exploiting phase contrast and dark-field imaging for <1μm feature detection in bulk materials (Summary Report)

Radiography is an important non-destructive characterization tool for many LANL missions. Contrast in conventional radiography results from attenuation of the incoming x-ray or neutron beam by the object. Neutrons have a great benefit in detecting light elements (e.g. hydrogen) in the presence of heavier elements and penetrate deeper than X-rays into many materials, but neutron radiography resolution is typically limited to ~50 μm. Cracks, voids, pores and a variety of other features smaller than this resolution are therefore undetectable in attenuation based neutron imaging. However, novel neutron imaging modalities leveraging off of interferometric methods, so-called neutron grating interferometry (NGI), are able to spatially map sub-micron features and interfacial features while also exploiting the neutron’s sensitivity to light elements and isotope specific contrast to enable material characterization otherwise impossible.

36 MATERIALS SCIENCE↗

Measurement report: A comparison of ground-level ice-nucleating-particle abundance and aerosol properties during autumn at contrasting marine and terrestrial locations

Abstract. Ice-nucleating particles (INPs) are an essential class of aerosols found worldwide that have far-reaching but poorly quantified climate feedback mechanisms through interaction with clouds and impacts on precipitation. These particles can have highly variable physicochemical properties in the atmosphere, and it is crucial to continuously monitor their long-term concentration relative to total ambient aerosol populations at a wide variety of sites to comprehensively understand aerosol–cloud interactions in the atmosphere. Hence, our study applied an in situ forced expansion cooling device to measure ambient INP concentrations and test its automated continuous measurements at atmospheric observatories, where complementary aerosol instruments are heavily equipped. Using collocated aerosol size, number, and composition measurements from these sites, we analyzed the correlation between sources and abundance of INPs in different environments. Toward this aim, we have measured ground-level INP concentrations at two contrasting sites, one in the Southern Great Plains (SGP) region of the United States with a substantial terrestrially influenced aerosol population and one in the Eastern North Atlantic Ocean (ENA) region with a primarily marine-influenced aerosol population. These measurements examined INPs mainly formed through immersion freezing and were performed at a ≤ 12 min resolution and with a wide range of heterogeneous freezing temperatures (Ts above −31 °C) for at least 45 d at each site. The associated INP data analysis was conducted in a consistent manner. We also explored the additional offline characterization of ambient aerosol particle samples from both locations in comparison to in situ data. From our ENA data, on average, INP abundance ranges from ≈ 1 to ≈ 20 L−1 (−30 °C ≤ T ≤ −20 °C) during October–November 2020. Backward air mass trajectories reveal a strong marine influence at ENA with 75.7 % of air masses originating over the Atlantic Ocean and 96.6 % of air masses traveling over open water, but analysis of particle chemistry suggests an additional INP source besides maritime aerosols (e.g., sea spray aerosols) at ENA. In contrast, 90.8 % of air masses at the SGP location originated from the North American continent, and 96.1 % of the time, these air masses traveled over land. As a result, organic-rich SGP aerosols from terrestrial sources exhibited notably high INP abundance from ≈ 1 to ≈ 100 L−1 (−30 °C ≤ T ≤ −15 °C) during October–November 2019. The probability density function of aerosol surface area-scaled immersion freezing efficiency (ice nucleation active surface site density; ns) was assessed for selected freezing temperatures. While the INP concentrations measured at SGP are higher than those of ENA, the ns(T) values of SGP (≈ 105 to ≈ 107 m−2 for −30 °C ≤ T ≤ −15 °C) are reciprocally lower than ENA for approximately 2 orders of magnitude (≈ 107 to ≈ 109 m−2 for −30 °C ≤ T ≤ −15 °C). The observed difference in ns(T) mainly stems from varied available aerosol surface areas, Saer, from two sites (Saer,SGP > Saer,ENA). INP parameterizations were developed as a function of examined freezing temperatures from SGP and ENA for our study periods.

54 ENVIRONMENTAL SCIENCES↗

High-contrast, convergent x-ray imaging with laser-Compton sources

Techniques are provided for the production of high-contrast, x-ray and/or gamma-ray radiographic images. The images have minimal contributions from object-dependent background radiation. The invention utilizes the low divergence, quasi-monoenergetic, x-ray or gamma-ray output from a laser-Compton source in combination with x-ray optical technologies to produce a converging x-ray or gamma-ray beam with which to produce a high-contrast, shadowgraph of a specific object. The object to be imaged is placed within the path of the converging beam between the x-ray optical assembly and the focus of the x-ray beam produced by that assembly. The beam is then passed through an optically thick pinhole located at the focus of the beam. Downstream of the pinhole, the inverted shadowgraph of the object is then recorded by an appropriate 2D detector array.

Barty, Christopher P. J.↗

Coded-mask-based X-ray phase-contrast and dark-field imaging

Phase contrast and dark-field X-ray imaging enable imaging of objects that absorb or reflect very little X-ray light. Disclosed is a method and systems for performing coded-mask-based multi-contrast imaging (CMMI). The method includes providing radiation to a coded mask that has a known phase and absorption profile according to a pre-determined pattern. The radiation is then impingent upon a sample, and the radiation is detected to perform phase-reconstruction and image processing. The method and associated systems allow for the use of maximum-likelihood and machine learning methods for reconstruction images of the sample from the detected radiation.

Shi, Xianbo↗

Investigation of near-field jet stability of a single-hole injector based on fast X-ray phase contrast imaging and image feature matching

Fuel spray is very effective in controlling the combustion process to improve engine performance and reduce emissions. Understanding the spray unstability during the injection process is of importance to improve the control of spray characteristics and engine operation. In this study, near-field biodiesel jets were recorded using fast X-ray phase contrast imaging and the flow features inside the jet were extracted using Speeded Up Robust Features (SURF) method. Here, the image similarity by feature matching was successfully used to represent the near-field jet stability. Based on the jet stability, an injection process can be divided into five stages: an unstable stage at needle opening, a partially stable transition stage at needle opening, a stable stage, a stable transition stage at needle closing and an unstable stage at needle closing. The ranges of needle lift for five stages were also determined. The jet unstability is highly related to the cavitation formation and gas purging process during needle opening. The variation of stable jet feature is dependent on the needle lift at needle closing. Higher needle lift for the similar jet feature at needle opening indicates a hydraulic delay compared to needle closing. Finally, the possible reasons of jet feature formation and feature detection used on the multi-hole injector are discussed.

33 ADVANCED PROPULSION SYSTEMS↗

Reduced volume of diabetic pancreatic islets in rodents detected by synchrotron X-ray phase-contrast microtomography and deep learning network

The pancreatic islet is a highly structured micro-organ that produces insulin in response to rising blood glucose. Here we develop a label-free and automatic imaging approach to visualize the islets in situ in diabetic rodents by the synchrotron radiation X-ray phase-contrast microtomography (SRμCT) at the ID17 station of the European Synchrotron Radiation Facility. The large-size images (3.2 mm × 15.97 mm) were acquired in the pancreas in STZ-treated mice and diabetic GK rats. Each pancreas was dissected by 3000 reconstructed images. The image datasets were further analysed by a self-developed deep learning method, AA-Net. All islets in the pancreas were segmented and visualized by the three-dimension (3D) reconstruction. After quantifying the volumes of the islets, we found that the number of larger islets (=>1500 μm 3 ) was reduced by 2-fold (wt 1004 ± 94 vs GK 419 ± 122, P < 0.001) in chronically developed diabetic GK rat, while in STZ-treated diabetic mouse the large islets were decreased by half (189 ± 33 vs 90 ± 29, P < 0.001) compared to the untreated mice. Our study provides a label-free tool for detecting and quantifying pancreatic islets in situ. It implies the possibility of monitoring the state of pancreatic islets in vivo diabetes without labelling.

59 BASIC BIOLOGICAL SCIENCES↗

Using electron channeling contrast imaging to inform and improve the growth of high-efficiency GaAs solar cells on nanopatterned GaAs substrates

Patterned substrates provide opportunities for reducing the cost of high-efficiency III-V devices by incorporating mechanically weak layers beneficial for substrate reuse (e.g. by spalling). In this work, the functionality of electron channeling contrast imaging (ECCI) as a tool to efficiently understand and mitigate defect formation is exemplified by developing a process in which high-quality III-V material can be grown on nanopatterned GaAs substrates. Reactive ion etching used in the patterning process was found to damage the GaAs substrate surface, leading to the formation of stacking faults in the epitaxial material as observed by ECCI. Etching the patterned substrates in a 1 NH4OH: 1 H2O2: 50 DI H2O solution for 10 s prior to growth removed the substrate surface damage and stacking faults were no longer present. Growth of solar cell device structures initially produced samples with many macroscale flaws creating shunts in the devices, which complicated the assessment of material quality by device measurements. However, ECCI revealed that the epitaxial material surrounding macroscale flaws was free from any crystallographic defects such as stacking faults and threading dislocations. With this knowledge, we focused on refining the patterning process to eliminate the macroscale flaws. Solar cells were then grown on the improved nanopatterned substrates and exhibited device structures with defect densities less than 5 x 105 cm -2 and average conversion efficiency of 24.8%, nearly identical to devices grown on unpatterned epi-ready substrates (25.0%).

14 SOLAR ENERGY↗

Wetting mechanism and alteration of nano-sized shale pores: Insights from contrast variation small angle neutron scattering

Wettability of tight shale is crucial for fluid flow and mass transport process in energy geosciences. However, understanding the interfacial chemistry and wetting mechanisms at sub-nano-pore scales remains a formidable challenge. Here, in this study, the Contrast Variation technique of Small Angle Neutron Scattering (CV-SANS) is employed to investigate shale’s interfacial chemistry using reagents that possess a range of different polarities, including water, n-decane, toluene, and dimethyl methanamide. Through five different experimental strategies, we have demonstrated a successful modification of shale wettability, ranging from enhancement, weakening, to reversal. Delving into the mechanisms, we illustrated the crucial role of pre-existing liquid films in these changes, where the uniquely co-existing polar and non-polar functional groups in dimethyl methanamide acted as a conduit for interfacial chemistry adjustments. Furthermore, a solvent immersion led to matrix dilation as well as liberation of residual oil-occupied pores, resulting in altered pore size distributions, with hydrogen bonding playing a significant role in the polar groups. Interestingly, despite shale exhibiting a stronger affinity for oil over water, hydrophilic solvents induced more substantial dilation than lipophilic ones. Collectively, this work elucidates the dynamic change of interfacial chemistry via the configuration of polarity using chemical reagents, and the CV-SANS technique underscores its invaluable utilities in decoding the interfacial wettability traits in nanopore space of shale.

58 GEOSCIENCES↗

Multiscale dynamic experiments on fiber-reinforced composites with damage assessment using high-speed synchrotron X-ray phase-contrast imaging

We report fiber-reinforced composites (FRCs) have been widely used as protection materials to replace heavier metals. However, predictive capabilities for the impact-induced failure of FRCs have not been well-developed. In this work, we introduced an integrated technique to visualize the dynamic failure of FRCs, with the modified Kolsky bar loading and the high-speed synchrotron X-ray phase-contrast imaging (PCI). We summarize our experimental studies across the FRCs’ structural levels by using this integrated technique, including single-fiber tensile experiments, fiber/matrix debonding experiments, and single-edge notched bending experiments on composite laminates. It is revealed that the high-speed synchrotron X-ray PCI technique possesses sufficient spatial resolution to identify the failure behavior of a single fiber in the 10-μm scale level, as well as temporal resolution to identify the time sequence of internal dynamic damage evolution. The technique can penetrate through the opaque composite sample and provide real-time visualization of small-scale damaging mechanisms such as the embedded fiber’s sliding in the matrix and the fiber’s transverse debonding with the matrix. At an expanding scale, the technique can identify the crack initiation and track the cracking behavior inside a single ply or between different plies of a composite laminate. High-speed visualization inside the material by this integrated technique provides critical deformation and failure information to develop physical understanding of the damage inside composites under impact.

47 OTHER INSTRUMENTATION↗

Contrast Mechanisms in Secondary Electron e-Beam-Induced Current (SEEBIC) Imaging

Abstract Over the last few years, a new mode for imaging in the scanning transmission electron microscope (STEM) has gained attention as it permits the direct visualization of sample conductivity and electrical connectivity. When the electron beam (e-beam) is focused on the sample in the STEM, secondary electrons (SEs) are generated. If the sample is conductive and electrically connected to an amplifier, the SE current can be measured as a function of the e-beam position. This scenario is similar to the better-known scanning electron microscopy-based technique, electron beam-induced current imaging, except that the signal in the STEM is generated by the emission of SEs, hence the name secondary electron e-beam-induced current (SEEBIC), and in this case, the current flows in the opposite direction. Here, we provide a brief review of recent work in this area, examine the various contrast generation mechanisms associated with SEEBIC, and illustrate its use for the characterization of graphene nanoribbon devices.

47 OTHER INSTRUMENTATION↗

Paramagnetic Mn 8 Fe 4 -co-Polystyrene Nanobeads as a Potential T 1 –T 2 Multimodal Magnetic Resonance Imaging Contrast Agent with In Vivo Studies

In developing a cluster-nanocarrier design, as a magnetic resonance imaging contrast agent, we have investigated the enhanced relaxivity of a manganese and iron-oxo cluster grafted within a porous polystyrene nanobead with increased relaxivity due to a higher surface area. The synthesis of the cluster-nanocarrier for the cluster Mn 8 Fe 4 O 12 (O 2 CC 6 H 4 CH=CH 2 ) 16 (H 2 O) 4 , cross-linked with polystyrene (the nano-carrier), under miniemulsion conditions is described. By including a branched hydrophobe, iso-octane, the resulting nanobeads are porous and similar to 70 nm in diameter. The increased surface area of the nanobeads compared to nonporous nanobeads leads to an enhancement in relaxivity; r 1 increases from 3.8 to 5.2 ± 0.1 mM -1 s -1 , and r 2 increases from 11.9 to 50.1 ± 4.8 mM -1 s -1 , at 9.4 teslas, strengthening the potential for T 1 and T 2 imaging. Several metrics were used to assess stability, and the porosity produced no reduction in metal stability. Synchrotron X-ray fluorescence microscopy was used to demonstrate that the nanobeads remain intact in vivo . In depth, physicochemical characteristics were determined, including extensive pharmacokinetics, in vivo imaging, and systemic biodistribution analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Equation-of-state measured via x-ray phase contrast imaging for Epon 828/DEA epoxy

Epoxies are a broad class of polymer materials often used as adhesive, structural or binding materials. Epon 828 is an epoxy resin that can be polymerized with a variety of curing agents with the choice of curing agent potentially having an effect on the resulting epoxy polymer’s material properties. In this study, the dynamic behavior of Epon 828 epoxy resin cured with diethanolamine (DEA) is investigated through a series of tamped Richtmyer-Meshkov instability (RMI) experiments measured with x-ray phase-contrast imaging. The measured shock and particle velocities are combined with data in the literature to calibrate Mie-Grüneisen equations-of-state (EOS) for portions and combinations of the collective dataset. The calibrated Mie-Grüneisen EOS are validated against particle velocity profiles extracted from published literature using the Eulerian hydrocode CTH. Here, the Mie-Grüneisen EOS fit to only the tamped RMI experimental data presented here most closely follows the particle velocity profile in the published literature.

36 MATERIALS SCIENCE↗

High-speed x-ray phase contrast imaging and digital image correlation analysis of microscale shock response of an additively manufactured energetic material simulant

The performance of energetic materials subjected to dynamic loading significantly depends on their micro- and meso-scale structural morphology. The geometric versatility offered by additive manufacturing opens new pathways to tailor the performance of these materials. Additively manufactured energetic materials (AMEMs) have a wide range of structural characteristics with a hierarchy of length scales and process-inherent heterogeneities, which are hitherto difficult to precisely control. It is important to understand how these features affect AMEMs’ response under dynamic/shock loading. Therefore, temporally and spatially resolved measurements of both macroscopic behavior and micro- and meso-level processes influencing macroscopic behavior are required. In this paper, we analyze the shock compression response of an AMEM simulant loaded under several impact conditions and orientations. Furthermore, x-ray phase contrast imaging (PCI) is used to track features across the observed shock front and determine the linear shock velocity vs particle velocity equation of state, as well as to quantify the interior deformation fields via digital image correlation (DIC) analyses. Photon Doppler velocimetry is simultaneously used to measure the particle velocities of the specimens, which are consistent with those obtained from x-ray PCI. The DIC analyses provide an assessment of the average strain fields inside the material, showing that the average axial strain depends on the loading intensity and reaches as high as 0.23 for impact velocities up to 1.5 km/s. The overall results demonstrate the utility of x-ray PCI for probing “in-material” equation of state and interior strains associated with dynamic shock compression behavior of the AMEM simulant.

3D printing↗

A Pockels cell enabled heterodyne phase contrast imaging diagnostic for detection of ion cyclotron emission

This work describes a novel optical heterodyne detection scheme that significantly extends the frequency response of the phase contrast imaging method to detect electron density fluctuations in tens of megahertz frequency range. The system employs a variable frequency electro-optic modulator to allow operation at any frequency in the range 10–40 MHz without the need to realign the system. The frequency coverage of the system makes it suitable to measure the radial structure of the electron density component of ion cyclotron emission on devices having confining magnetic field of a few tesla, thus extending the purely temporal measurements provided so far by magnetic probes.

47 OTHER INSTRUMENTATION↗

X-ray phase-contrast imaging of strong shocks on OMEGA EP

The ongoing improvement in laser technology and target fabrication is opening new possibilities for diagnostic development. An example is x-ray phase-contrast imaging (XPCI), which serves as an advanced x-ray imaging diagnostic in laser-driven experiments. In this work, we present the results of the XPCI platform that was developed at the OMEGA EP Laser-Facility to study multi-Mbar single and double shocks produced using a kilojoule laser driver. Two-dimensional radiation-hydrodynamic simulations agree well with the shock progression and the spherical curvature of the shock fronts. It is demonstrated that XPCI is an excellent method to determine with high accuracy the front position of a trailing shock wave propagating through an expanding CH plasma that was heated by a precursor Mbar shock wave. Furthermore, the interaction between the rarefaction wave and the shock wave results in a clear signature in the radiograph that is well reproduced by radiation-hydrodynamic simulations.

47 OTHER INSTRUMENTATION↗