Search NASA⌕ Search

SEARCH · Search NASA

Results for “cost projections”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Impacts of PV Module Connector Failures on Cost and Performance of Utility Scale Photovoltaic Systems

The reliability, cost and performance of electrical connectors are a concern in all types of electrical systems, and demands on connectors used on photovoltaic (PV) systems include that connectors maintain electrical conductivity and physical strength, endure ultraviolet sunlight and high ambient temperature, and resist moisture and chemical intrusion over a very long (>25 year) performance period. Connector failures increase operation and maintenance (O&M) costs and reduce plant production, but connector failure can also cause safety and liability problems, which are of greater concern. This work results from a three-year collaboration between Sandia National Laboratories (SNL), the Electric Power Research Institute (EPRI), and the National Renewable Energy Laboratory (NREL) and funded by the U.S. Department of Energy (DOE) Solar Energy Technology Office (SETO) under Agreements #39035 and #38531 "Connector Reliability Across the US Solar Sector." a multi-pronged investigation of PV connector health across the US (see https://energy.sandia.gov/pvconnectors/). This report presents derivation of a Techno-Economic Analysis (TEA) that models failure modes and frequencies (how often failure occurs), estimates O&M costs and lost production associated with connector failures, and then calculates the effect that PV module connectors can have on Levelized Cost of Energy (LCOE). The model is informed with initial data from quantitative assessment of failure rates, root causes and mechanisms, in-situ diagnostics and data collection, lab-based forensics, and interviews with PV connector manufacturers and plant operators. SNL conducted site inspections at multiple utility-scale sites in different climates and subjected field samples of new, used, and degraded connectors to visual and electrical characterization. EPRI conducted metallurgical analysis of the pin and sleeve conductors to study failure-induced morphological and compositional changes. There is in general a shortage of statistically valid data, but data from PVROM database maintained by SNL was sufficient to ascertain failure rates and lost production as well as provide qualitative insight in its curated maintenance records. This report details the structure of the mathematical model but the sources of data to inform the model will continue to evolve. Analysis of a 100 MW PV plant is provided as an example of the use of the model, with results indicating that connectors are responsible for Annualized O&M Costs of $\$$71,933/year; Annualized Unit O&M Costs of $\$$0.72/kW/year; that a Reserve Account of $\$$187,220 should be available to fund repairs related to connectors; that connectors add $\$$1,494,004 to the Net Present Value of the O&M Costs (project life); and that O&M related to connectors adds about $\$$0.00088/kWh to the Levelized Cost of Energy. The impact of this model is to provide a tool to make the US solar sector more robust by quantifying and monetizing the reliability risks to utility-scale PV systems posed by poorly installed, mismatched and/or poorly designed and manufactured connectors. The TEA provides a model incorporating failure statistics, O&M cost data, and lost production into a single figure of merit, informing decisions and enabling practitioners to optimize cost and performance trade-offs. Stakeholders include connector manufacturers, system designers and equipment specifiers, standards bodies, installers and O&M providers, investors and insurance underwriters. This report supports continued growth of PV predicated on assurances that properly installed and maintained PV system connectors are safe and reliable. The project team is proposing future work including accelerated testing of connectors and expanding the approach taken here to other PV system components, such as TEA for rapid shut-down devices.

14 SOLAR ENERGY↗

Restoring Pre-Industrial CO2 Levels While Achieving Sustainable Development Goals

Unless humanity achieves United Nations Sustainable Development Goals (SDGs) by 2030 and restores the relatively stable climate of pre-industrial CO2 levels (as early as 2140), species extinctions, starvation, drought/floods, and violence will exacerbate mass migrations. This paper presents conceptual designs and techno-economic analyses to calculate sustainable limits for growing high-protein seafood and macroalgae-for-biofuel. We review the availability of wet solid waste and outline the mass balance of carbon and plant nutrients passing through a hydrothermal liquefaction process. The paper reviews the availability of dry solid waste and dry biomass for bioenergy with CO2 capture and storage (BECCS) while generating Allam Cycle electricity. Sufficient wet-waste biomass supports quickly building hydrothermal liquefaction facilities. Macroalgae-for-biofuel technology can be developed and straightforwardly implemented on SDG-achieving high protein seafood infrastructure. The analyses indicate a potential for (1) 0.5 billion tonnes/yr of seafood; (2) 20 million barrels/day of biofuel from solid waste; (3) more biocrude oil from macroalgae than current fossil oil; and (4) sequestration of 28 to 38 billion tonnes/yr of bio-CO2. Carbon dioxide removal (CDR) costs are between 25–33% of those for BECCS with pre-2019 technology or the projected cost of air-capture CDR.

54 ENVIRONMENTAL SCIENCES↗

Technoeconomic Evaluation of Microreactor Using Detailed Bottom-up Estimate (Rev.1)

Microreactors are a novel class of nuclear reactors that are expected to be factory produced, transportable, and self-regulating. They are expected to be several orders of magnitude smaller in size than traditional reactors (with power outputs in the 1–20 MWe range typically). They are primarily envisaged to target niche, remote markets that are difficult to access and where energy costs are high. There has been a scarcity of technoeconomic assessment for these types of reactors due to the scarcity of designs without proprietary restraints (e.g., those that include balance of plants and building layouts) and cost estimates. The primary objective of this report was to develop a transparent, detailed, bottom-up cost estimate for a microreactor. While there is a high degree of uncertainty associated with the projected costs, this work provides a foundation that can built upon and improved to better model the economics of microreactors. The Microreactor Applications Research, Validation, and Evaluation (MARVEL) microreactor was selected for this analysis. This Department of Energy–sponsored demonstration was chosen because (1) its final design was recently completed and (2) a detailed class-3 cost-and-schedule estimation was conducted for it. This provided a strong technical basis for further analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a high capacity bubble domain memory element and related epitaxial garnet materials for application in spacecraft data recorders. Item 1: Development of a high capacity memory element

Several versions of the 100K bit chip, which is configured as a single serial loop, were designed, fabricated and evaluated. Design and process modifications were introduced into each succeeding version to increase device performance and yield. At an intrinsic field rate of 150 KHz the final design operates from -10 C to +60 C with typical bias margins of 12 and 8 percent, respectively, for continuous operation. Asynchronous operation with first bit detection on start-up produces essentially the same margins over the temperature range. Cost projections made from fabrication yield runs on the 100K bit devices indicate that the memory element cost will be less than 10 millicents/bit in volume production.

Besser, P. J.↗

Amateur Cleanrooms: Costs May Not Offset Benefits

Contamination and Coatings Branch During my career at NASA, I have encountered a variety of cleanroom systems. With many projects, cost pressures and lack of adequate facilities have forced the managers to resort to amateur cleanrooms to manufacture spacecraft and instruments. These rooms are usually spaces that have been used for other purposes that are converted to cleanroom, usually without the assistance of a contamination control specialist. Often, scientists and engineers are successful in converting an area for experimental use. However, when the area is used for production, countless difficulties are encountered. This paper will document some of the disasters that I have personally witnessed and offer some guidelines for contamination professionals to follow if you are called upon to assist in the development of new cleanrooms. Cleanroom come in all shapes and sizes from special purpose mini-environments (such as flow benches) to large, expansive production facilities. These areas may require a variety of unit operations to be carried out within a short range of each other. The design of the cleanroom should account for compatibilities of these operations to protect the product and personnel. The level of cleanliness has traditionally been associated with the method of ventilation. However, just because and =ea has HEPA filters and greater that 20 air changes per hour does not mean that it is a cleanroom. Airflow is extremely complex; the only way to properly design a cleanroom is through the use of a computer based model. In the aerospace industry, few engineered cleanrooms are modeled. Modeling has been perceived as expensive; however, modern programs and fast computers are changing perception. It is the lack of appreciation for how air flow and location within a cleanroom affects the product that causes most of the problems I have experienced. Currently, the rules defining the best air flow design practices are based on simplistic historical data that are often wrong. The performance of a cleanroom is defined by a set of complex interactions between the airflow, sources of contamination and heat, position of the air terminals and exhausts as well as the objects occupying the space in question. These subtleties are almost never appreciated in the setup of amateur cleanrooms (and sadly, in some engineered cleanroom as well). Experience with the room, measurement of air flows in the room, and black light inspections can be used to

Ramsey, W. Lawrence↗

Cost estimates for flat plate and concentrator collector arrays

The current module and installation costs for the U.S. National Photovoltaic Program's grid-connected systems are significantly higher than required for economic viability of this alternative. Attention is accordingly given to the prospects for installed module cost reductions in flat plate, linear focus Fresnel concentrator, and point focus Fresnel concentrator candidate systems. Cost projections indicate that all three systems would meet near-term and midterm goals, provided that module costs of $2.80/W(p) and $0.70/W(p), respectively, are met. The point focus Fresnel system emerges as the most viable for the near term.

Shimada, K.↗

Effects of raster terrain representation on GIS shortest path analysis

Spatial analysis extracts meaning and insights from spatially referenced data, where the results are highly dependent on the quality of the data used and the manipulations on the data when preparing it for analysis. Users should understand the impacts that data representations may have on their results in order to prevent distortions in their outcomes. We study the consequences of two common data preparations when locating a linear feature performing shortest path analysis on raster terrain data: 1) the connectivity of the network generated by connecting raster cells to their neighbors, and 2) the range of the attribute scale for assigning costs. Such analysis is commonly used to locate transmission lines, where the results could have major implications on project cost and its environmental impact. Experiments in solving biobjective shortest paths show that results are highly dependent on the parameters of the data representations, with exceedingly variable results based on the choices made in reclassifying attributes and generating networks from the raster. Based on these outcomes, we outline recommendations for ensuring geographic information system (GIS) data representations maintain analysis results that are accurate and unbiased.

Medrano, F. Antonio (ORCID:000000025913632X)↗

Encapsulant materials for $2/watt terrestrial photovoltaic arrays

Materials properties, cost data, and strawman designs are presented relative to materials for $2/watt terrestrial photovoltaic arrays to meet LSA Project cost goals for 1982. It is shown that encapsulation materials can be categorized in six basic elements: top covers, super-strates, pottants, adhesives, substrates, and bottom covers. The roles of the six basic encapsulant material elements in the encapsulant system are discussed and candidate materials presented.

Maxwell, H.↗

Low Carbon Intensity Formic Acid Chemical Synthesis from Direct Air Captured CO 2 Utilizing Chemical Plant Waste Heat - Final Technical Report

The primary objective of Low Carbon Intensity Formic Acid Chemical Synthesis from Direct Air Captured CO 2 Utilizing Chemical Plant Waste Heat (ChemFADAC) is to execute and complete a FEED study for an integrated direct air capture (DAC) and carbon conversion system (together, the DACUS system) co-located at a Nutrien nitric acid production facility in Kennewick, WA capable of capturing and converting a minimum of 5,000 MT/year net atmospheric CO 2 to low carbon intensity formic acid (FA) using industrial waste heat and renewable electricity. The goal will be achieved through the completion of four objectives using a collaborative approach with community stakeholders. Objective 1. Conduct a FEED study and Class 3 project cost estimate for the proposed DACUS system that maximizes use of thermal energy from the Nutrien KFO host site to produce low carbon intensity FA from atmospheric CO 2 . Objective 2. Perform a cradle-to-gate life-cycle analysis of the DACUS system to determine the environmental sustainability and carbon intensity (CI) of the proposed project and product from the results of the FEED study. Objective 3. Perform a business case analysis from results of the LCA, FEED study and cost estimate to justify investment to build the DACUS project at the Nutrien KFO site. Objective 4. Quantify how deployment of the proposed technology will promote and prepare a ready workforce for clean energy and manufacturing jobs and coordinate with community stakeholders to perform an environmental justice and a preliminary economic revitalization and job creation outcomes analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Storage Futures Study - Distributed Solar and Storage Outlook: Methodology and Scenarios

This presentation discusses the fourth report in NREL’s Storage Futures Study (SFS) publications. The SFS is a multiyear research project that explores the role and impact of energy storage in the evolution and operation of the U.S. power sector. The SFS is designed to examine the potential impact of energy storage technology advancement on the deployment of utility-scale storage and the adoption of distributed storage, and the implications for future power system infrastructure investment and operations. This report describes the expanded capabilities of the Distributed Generation Market Demand (dGen) model to analyze the economics of distributed (behind-the-meter) PV paired with battery storage systems and presents projections of adoption for the contiguous United States out to 2050 under a range of scenarios. These scenarios use technology cost and performance assumptions consistent with the National Renewable Energy Laboratory’s 2020 Standard Scenarios paired with updated battery cost projections and existing policies. Additional scenarios evaluate sensitivities to the value of backup power and DER compensation mechanisms, collectively characterizing the future potential for behind-the-meter storage and identifying key drivers of adoption. Adoption projections of DER and battery storage at high spatial and temporal resolution, as presented in this report, can enable informed planning of technical infrastructure that can help planners capture the benefits and mitigate challenges to support the ongoing trend toward distributed electricity generation.

backup power↗

Inexpensive Cable Space Launcher of High Capability

This paper proposes a new method and transportation system to fly into space, to the Moon, Mars, and other planets. This transportation system uses a mechanical energy transfer and requires only minimal energy so that it provides a 'Free Trip' into space. The method uses the rotary and kinetic energy of planets, asteroids, moons, satellites and other natural space bodies. computations for the following projects: 1. Non-Rocket Method for free launch of payload in Space and to other planets. The low cost project will accommodate one hundred thousand tourists annually. 2. Free Trips to the Mars for two thousand annually. 3. Free Trips to the Moon for ten thousand people annually. The projects use artificial materials like nanotubes and whiskers that have a ratio of tensile strength to density equal 4 million meters. In the future, nanotubes will be produced that can reach a specific stress up 100 millions meter and will significantly improve the parameters of suggested projects. The author is prepared to discuss the problems with serious organizations that want to research and develop these inventions.

Bolonkin, Alexander↗

Application of quantitative risk assessment to address stakeholder questions in geologic carbon storage

Ambitious international greenhouse gas emissions reduction targets demand a rapid transformation to a low-carbon economy. This transformation includes the accelerated adoption of carbon dioxide (CO2) capture and storage (CCS) technology. However, as with any large-scale engineering enterprise, the widespread commercial-scale deployment of geologic carbon storage (GCS) raises important questions about technology and cost-effectiveness, safety, environmental risk, and long-term liability. Effectively assessing and managing risks and liability associated with GCS projects is a key technical need throughout the project life cycle-from site selection and permitting to monitoring design, operational risk management, and post-operational site closure. This presentation highlights recent advancements in tools for quantitative risk assessment, being developed by the National Risk Assessment Partnership (NRAP). NRAP is a multi-year, multinational laboratory research collaboration sponsored by the U.S. Department of Energy's Office of Fossil Energy and Carbon Management. Our focus will be on these tools' applications in addressing critical stakeholder questions related to supporting permitting to ensure secure and environmentally protective storage; designing effective and efficient monitoring plans; evaluating the effectiveness of remedial actions and risk management alternatives; and informing liability assessment and investment decisions. This paper will detail the key functionality of NRAP’s Open-Source Integrated Assessment Model (NRAP-Open-IAM), a computational framework for assessing leakage risk and containment assurance. This model features streamlined workflows for calculating leakage risk profiles, delineating risk-based area of review, and assessing contingency plans and post-injection site care requirements. ORION is an open-source, observation-based ensemble forecasting toolkit to help operators assess the seismic hazard at a carbon storage site. The State of Stress Analysis Tool (SOSAT), designed to assess subsurface stress conditions and evaluate geomechanical risk resulting from CO2 injection in an area of interest will also be presented. We will also introduce a prototype model to evaluate storage project costs and liability associated with risk management. The Technoeconomic and Liability Evaluation for Storage (TALES) model uses results from forecasts of leakage and induced seismicity risk to estimate the lifecycle cost of managing risk. Finally, a preliminary example of how the NRAP Risk-based Adaptive Monitoring Plan (RAMP) tool can be used to design efficient and effective site monitoring plans and estimate the detectability of fluid leakage will be provided. The relevance of these tools for addressing key stakeholder questions amidst uncertainty will be emphasized.

decision support↗

Cost analysis of new and retrofit hot-air type solar assisted heating systems

A detailed cost analysis/cost improvement study was performed on two Department of Energy/National Aeronautics and Space Administration operational test sites to determine actual costs and potential cost improvements of new and retrofit hot air type, solar assisted heating and hot water systems for single family sized structures. This analysis concentrated on the first cost of a system which included procurement, installation, and integration of a solar assisted heating and hot water system on a new or retrofit basis; it also provided several cost projections which can be used as inputs to payback analyses, depending upon the degree of optimism or future improvements assumed. Cost definitions were developed for five categories of cost, and preliminary estimates were developed for each. The costing methodology, approach, and results together with several candidate low cost designs are described.

Stewart, R. D.↗

Quantifying Investment Risk: Analysis of the Purchase Decision of a Nuclear Power Plant (Presentation)

Cost overruns are an ill-fated part of the deployment history of nuclear power plants (NPPs) in the United States, and yet studies increasingly show the important role nuclear technologies must play in decarbonizing the U.S. economy. Paradoxically, then, a key piece of a coherent decarbonization strategy depends on attracting investor action to a purchase where historical cost overruns have been sizable. To address this challenge, this study aims to develop a financial model that quantifies the risk of cost overruns in the decision-making process for purchasing advanced reactor concepts. Using the concept of value at risk (VaR), the model is built to evaluate financial risk nuclear construction with the aim to identify risk mitigation strategies. The objective is to identify strategies to mitigate cost-risk challenges and assess the potential reduction in investor risk exposure. This paper presents the initial development and preliminary verification of the financial risk analysis model. The development of this model involved a comprehensive approach to estimating financial risk over the operating life of NPP that stems from construction uncertainties. By utilizing net present value (NPV) with discounted cash flows, the model captures the complex interconnections of project costs, construction timelines, revenue, and uncertainties. Verifying the model involved testing historical data from previous reactor construction projects against the construction project of Vogtle 3 and 4. This paper’s results present the comparison of the preconstruction cost overrun prediction with the current cost estimates from a nearly complete Vogtle 3 and 4.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spacelab development and its operational verification

This paper gives a brief status report on the current Spacelab program and describes how the results of ground and flight tests will be combined to provide the operational verification of the system. For the on-going project, data on design, testing and fabrication plans are presented. In particular, recent changes to meet the constraints of a 'build-to-cost' project are described. In the operational verification of Spacelab, ground and flight tests which ESA and NASA will perform are addressed. The installation of test instrumentation and the performance of integrated tests will be accomplished in the US. Experiments for the first flight will be integrated into Spacelab racks and pallets and simulated mission tests performed. On-orbit, system thermal surveys are planned and stress data will be obtained during launch and re-entry.

Bignier, M.↗

Solar thermal technologies benefits assessment: Objectives, methodologies and results for 1981

The economic and social benefits of developing cost competitive solar thermal technologies (STT) were assessed. The analysis was restricted to STT in electric applications for 16 high insolation/high energy price states. Three fuel price scenarios and three 1990 STT system costs were considered, reflecting uncertainty over fuel prices and STT cost projections. After considering the numerous benefits of introducing STT into the energy market, three primary benefits were identified and evaluated: (1) direct energy cost savings were estimated to range from zero to $50 billion; (2) oil imports may be reduced by up to 9 percent, improving national security; and (3) significant environmental benefits can be realized in air basins where electric power plant emissions create substantial air pollution problems. STT research and development was found to be unacceptably risky for private industry in the absence of federal support. The normal risks associated with investments in research and development are accentuated because the OPEC cartel can artificially manipulate oil prices and undercut the growth of alternative energy sources.

Gates, W. R.↗

Quantifying Investment Risk: Analysis of the Purchase Decision of a Nuclear Power Plant

Cost overruns are an ill-fated part of the deployment history of nuclear power plants (NPPs) in the United States, and yet studies increasingly show the important role nuclear technologies must play in decarbonizing the U.S. economy. Paradoxically, then, a key piece of a coherent decarbonization strategy depends on attracting investor action to a purchase where historical cost overruns have been sizeable. To address this challenge, this study aims to develop a financial model that quantifies risk of cost overruns in the decision-making process for purchasing advanced reactor concepts. Using the concept of Value at Risk (VaR), the model is built to evaluate financial risk nuclear construction with the aim to identify risk mitigation strategies. The objective is to identify strategies to mitigate cost-risk challenges and to assess the potential reduction in investor risk exposure. The paper presents the initial development and preliminary verification of the financial risk analysis model. The development of this model involved a comprehensive approach to estimating financial risk over the operating life of NPP that stems from construction uncertainties. By utilizing net present value (NPV) with discounted cash flows, the model captures the complex interconnections of project costs, construction timelines, revenue, and uncertainties. Verification of the model involved testing historical data from previous reactor construction projects against the construction project of Vogtle 3 and 4. The results of this paper present the comparison of the preconstruction cost overrun prediction with the current cost estimates from a nearly complete Vogtle 3 and 4.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Value of Geothermal Energy Storage for Supply-Side and Demand-Side Applications

This report presents the results of a study examining the value potential for geothermal energy storage (GES), a long-duration energy storage resource that stores thermal and/or geomechanical energy in the subsurface. GES could benefit the overall U.S. power system by temporally shifting electricity generation (supply-side) or meeting building heating and cooling load (demand-side). This report analyzes supply-side and demand-side opportunities independently because of differences in applications and models. Currently there is significant uncertainty about the development costs for GES, with only a limited number of demonstration plants for electric energy storage and building heating and cooling storage developments. In this report, we estimate the value of supply-side and demand-side GES to the bulk power system in the contiguous United States. Because of the significant uncertainty about GES development costs, this analysis does not consider GES deployment costs but instead focuses on the value of GES to the U.S. electricity system. The estimated values of GES provide reference points for economically competitive commercial cost targets. Supply-side GES is modeled as part of an enhanced geothermal system (EGS) generation plant in NREL's Regional Energy Deployment System (ReEDS) capacity expansion model (Ho et al. 2021). In contrast to conventional geothermal plants, which generate constant power, EGS plants have unique features that may allow for in-reservoir energy storage for flexible generation. Demand-side GES for heating and cooling, including seasonal hot and cold storage and short-duration heat pump storage, is incorporated into a price-taker model using Cambium electricity marginal cost projections. To establish an upper bound for the value of GES, analysis focused on favorable scenarios for storage with high generation from zero marginal cost, variable renewable energy resources. High penetrations of variable renewable energy generation can increase hourly electricity price variability, which increases the value of temporal energy arbitrage for storage technologies like GES.

15 GEOTHERMAL ENERGY↗