Search NASA⌕ Search

SEARCH · Search NASA

Results for “degradation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A study of environmental characterization of conventional and advanced aluminum alloys for selection and design. Phase 2: The breaking load test method

A technique is demonstrated for accelerated stress corrosion testing of high strength aluminum alloys. The method offers better precision and shorter exposure times than traditional pass fail procedures. The approach uses data from tension tests performed on replicate groups of smooth specimens after various lengths of exposure to static stress. The breaking strength measures degradation in the test specimen load carrying ability due to the environmental attack. Analysis of breaking load data by extreme value statistics enables the calculation of survival probabilities and a statistically defined threshold stress applicable to the specific test conditions. A fracture mechanics model is given which quantifies depth of attack in the stress corroded specimen by an effective flaw size calculated from the breaking stress and the material strength and fracture toughness properties. Comparisons are made with experimental results from three tempers of 7075 alloy plate tested by the breaking load method and by traditional tests of statistically loaded smooth tension bars and conventional precracked specimens.

Sprowls, D. O.↗

Life Limiting Behavior in Interlaminar Shear of Continuous Fiber-Reinforced Ceramic Matrix Composites at Elevated Temperatures

Interlaminar shear strength of four different fiber-reinforced ceramic matrix composites was determined with doublenotch shear test specimens as a function of test rate at elevated temperatures ranging from 1100 to 1316 C in air. Life limiting behavior, represented as interlaminar shear strength degradation with decreasing test rate, was significant for 2-D crossplied SiC/MAS-5 and 2-D plain-woven C/SiC composites, but insignificant for 2-D plain-woven SiC/SiC and 2-D woven Sylramic (Dow Corning, Midland, Michigan) SiC/SiC composites. A phenomenological, power-law delayed failure model was proposed to account for and to quantify the rate dependency of interlaminar shear strength of the composites. Additional stress rupture testing in interlaminar shear was conducted at elevated temperatures to validate the proposed model. The model was in good agreement with SiC/MAS-5 and C/SiC composites, but in poor to reasonable agreement with Sylramic SiC/SiC. Constant shear stress-rate testing was proposed as a possible means of life prediction testing methodology for ceramic matrix composites subjected to interlaminar shear at elevated temperatures when short lifetimes are expected.

Choi, Sung R.↗

Evaluation of reusable surface insulation for space shuttle over a range of heat-transfer rate and surface temperature

Reusable surface insulation materials, which were developed as heat shields for the space shuttle, were tested over a range of conditions including heat-transfer rates between 160 and 620 kW/sq m. The lowest of these heating rates was in a range predicted for the space shuttle during reentry, and the highest was more than twice the predicted entry heating on shuttle areas where reusable surface insulation would be used. Individual specimens were tested repeatedly at increasingly severe conditions to determine the maximum heating rate and temperature capability. A silica-base material experienced only minimal degradation during repeated tests which included conditions twice as severe as predicted shuttle entry and withstood cumulative exposures three times longer than the best mullite material. Mullite-base materials cracked and experienced incipient melting at conditions within the range predicted for shuttle entry. Neither silica nor mullite materials consistently survived the test series with unbroken waterproof surfaces. Surface temperatures for a silica and a mullite material followed a trend expected for noncatalytic surfaces, whereas surface temperatures for a second mullite material appeared to follow a trend expected for a catalytic surface.

Chapman, A. J.↗

Total Ionizing Dose Effects in Bipolar and BiCMOS Devices

This paper describes total ionizing dose (TID) test results performed at JPL. Bipolar and BiCMOS device samples were tested exhibiting significant degradation and failures at different irradiation levels. Linear technology which is susceptible to low-dose dependency (ELDRS) exhibited greater damage for devices tested under zero bias condition.

radiation effects↗

High Current ESD Test of Advanced Triple Junction Solar Array Coupon

Testing was conducted on an Advanced Triple Junction (ATJ) coupon that was part of a risk reduction effort in the development of a high-powered solar array design by Space Systems Loral, LLC (SSL). The ATJ coupon was a small, 4-cell, two-string configuration of flight-type design that has served as the basic test coupon design used in previous SSL environmental aging campaigns. The objective of the present test was to evaluate the performance of the coupon after being subjected to induced electrostatic discharge (ESD) testing at two string voltages (100 V, 150 V) and four string currents (1.65 A, 2.0 A, 2.475 A, and 3.3 A). An ESD test circuit, unique to SSL solar array design, was built that simulates the effect of missing cells and strings in a full solar panel with special primary arc flashover circuitry. A total of 73 primary arcs were obtained that included 7 temporary sustained arcs (TSA) events. The durations of the TSAs ranged from 50 micro-seconds to 2.75 milli-seconds. All TSAs occurred at a string voltage of 150 V. Post-ESD functional testing showed that no degradation occurred due to the TSA events. These test results point to a robust design for application to a high-current, high-power mission.

Wright, Kenneth H., Jr.↗

Thermal Cycling of Mir Cooperative Solar Array (MCSA) Test Panels

The Mir Cooperative Solar Array (MCSA) project was a joint US/Russian effort to build a photovoltaic (PV) solar array and deliver it to the Russian space station Mir. The MCSA is currently being used to increase the electrical power on Mir and provide PV array performance data in support of Phase 1 of the International Space Station (ISS), which will use arrays based on the same solar cells used in the MCSA. The US supplied the photovoltaic power modules (PPMs) and provided technical and programmatic oversight while Russia provided the array support structures and deployment mechanism and built and tested the array. In order to ensure that there would be no problems with the interface between US and Russian hardware, an accelerated thermal life cycle test was performed at NASA Lewis Research Center on two representative samples of the MCSA. Over an eight-month period (August 1994 - March 1995), two 15-cell MCSA solar array 'mini' panel test articles were simultaneously put through 24,000 thermal cycles (+80 C to -100 C), equivalent to four years on-orbit. The test objectives, facility, procedure and results are described in this paper. Post-test inspection and evaluation revealed no significant degradation in the structural integrity of the test articles and no electrical degradation, not including one cell damaged early as an artifact of the test and removed from consideration. The interesting nature of the performance degradation caused by this one cell, which only occurred at elevated temperatures, is discussed. As a result of this test, changes were made to improve some aspects of the solar cell coupon-to-support frame interface on the flight unit. It was concluded from the results that the integration of the US solar cell modules with the Russian support structure would be able to withstand at least 24,000 thermal cycles (4 years on-orbit).

Hoffman, David J.↗

Evaluation of AMSOIL® -ANT PGW Coolant Formula Change and Super Space AMSOIL Development

AMSOIL ® Propylene Glycol Water (PGW), is the baselined internal thermal control fluid for multiple manned spacecraft including Gateway (HALO, IHAB, and ALM modules) and Orion. The use of AMSOIL-ANT PGW was originally validated through extensive NASA/Collins materials-compatibility testing (circa 2008–2015). However, in late 2019, AMSOIL implemented an unannounced change in its PG inhibitor package. Because of this reformulation, concerns around materials compatibility arose. Therefore, NASA initiated corrosion rate and coolant stability testing in 2024. Results showed that the reformulated AMSOIL PG produced substantially elevated corrosion rates in aluminum alloys (about two times when compared to the original AMSOIL PG formula) accompanied by visible surface degradation. Coolant stability testing indicated accelerated propylene-glycol breakdown as well, with glycolate levels about nine times higher than the original formulation. Based on these findings, NASA Materials & Processes and Thermal Control Systems groups have baselined the use of the original PGW chemistry for all spacecraft use. In response, AMSOIL produced a reformulated variant, “Super Space AMSOIL” (ANT-SSA), compliant with MPCV 70156.This paper documents the reformulation testing completed, details on the formulation change, and the development of Super Space AMSOIL.

Woody Beringer↗

Evaluation of AMSOIL ® -ANT PGW Coolant Formula Change and Super Space AMSOIL ® Development

AMSOIL ® Propylene Glycol Water (PGW), is the baselined internal thermal control fluid for multiple manned spacecraft including Gateway (HALO, IHAB, and ALM modules) and Orion. The use of AMSOIL-ANT PGW was originally validated through extensive NASA/Collins materials-compatibility testing (circa 2008–2015). However, in late 2019, AMSOIL implemented an unannounced change in its PG inhibitor package. Because of this reformulation, concerns around materials compatibility arose. Therefore, NASA initiated corrosion rate and coolant stability testing in 2024. Results showed that the reformulated AMSOIL PG produced substantially elevated corrosion rates in aluminum alloys (about two times when compared to the original AMSOIL PG formula) accompanied by visible surface degradation. Coolant stability testing indicated accelerated propylene-glycol breakdown as well, with glycolate levels about nine times higher than the original formulation. Based on these findings, NASA Materials & Processes and Thermal Control Systems groups have baselined the use of the original PGW chemistry for all spacecraft use. In response, AMSOIL produced a reformulated variant, “Super Space AMSOIL” (ANT-SSA), compliant with MPCV 70156.This paper documents the reformulation testing completed, details on the formulation change, and the development of Super Space AMSOIL.

David Brockett↗

Effects of simulated space environment on Skylab parasol material

A material consisting of ripstop nylon bonded to the Mylar side of aluminized Mylar film was used to construct the first Skylab parasol. The mechanical properties of elongation and tensile strength and the radiative properties of solar absorptance and thermal emittance were measured before and after exposure to simulated solar radiation at intensities of 1.0 and 3.5 solar constants for exposure times as long as 947 hours or 3316 equivalent solar hours. The accelerated testing indicated more severe degradation than was experienced in the real-time test (1 solar constant). The results predicted that this material could have given satisfactory performance throughout the planned lifetime of the Skylab workshop.

Slemp, W. S.↗

Characterization of degraded nickel cadmium cells

Various cells were cycled until degradation and then tested to determine the electrochemical characterization of the cells with regard to charge control. A constant voltage charged to a temperature-biased voltage, using up to an 8-voltage limit was used for the evaluation. Graphs show severe discharge voltage degradation with cycling and periodic capacity discharge; voltage extremes for cells with and without periodic capacity discharges; voltage extremes for cells with high rate discharge; voltage-temperature levels used for charge control; end of charge current and discharge voltage for 5 percent DOD cycling; cell capacity following 5 percent DOD cycling; and the end of discharge voltage and typical charge current profiles for the 20 percent DOD cycling.

Gross, S.↗

Accelerated testing for synchronous orbits

Degradation of batteries during synchronous orbits is analyzed. Discharge and recharge rates are evaluated. The functional relationship between charge rate and degradation is mathematically determined.

Mcdermott, P.↗

RCA SATCOM Battery in Orbit Performance Update and Accelerated Life Test Results

No significant degradation of nickel cadmium battery performance in SATCOM F1 and F2 after almost 8 and 7-3/4 years in orbit was shown. Battery minimum discharge voltage data are presented for these spacecraft. In addition, 2 groups of nickel cadmium cells which are representative of those in orbit are undergoing real time eclipse-reduced suntime cycling in the laboratory. These groups of cells, which are being cycled at a maximum of 53% and 62% depth of discharge (based on actual capacity), have completed 14 and 15 eclipse seasons, respectively. Data for these groups of cells are presented and are compared with the in-orbit battery data.

Gaston, S. J.↗

Assessing photovoltaic module degradation and lifetime from long term environmental tests

The photovoltaic module failure mechanisms related to temperature, humidity, and electrical bias are analyzed using the data collected over a period of 20 years from various sites in the U.S. The approach is based on measuring the rate dependence of the mechanisms on site stress levels, and then using the rate data to analytically estimate the field life by means of computer models of the site environment. A correlation is established between the accelerated constant-stress testing and the time-varying field exposures. Test results are presented for two failure mechanisms for a module design featuring polyvinyl butyral encapsulant for the temperature range of 85 to 100 C and 85-percent relative humidity.

Otth, D. H.↗

Development of a high-temperature durable catalyst for use in catalytic combustors for advanced automotive gas turbine engines

Durable catalytic reactors for advanced gas turbine engines were developed. Objectives were: to evaluate furnace aging as a cost effective catalytic reactor screening test, measure reactor degradation as a function of furnace aging, demonstrate 1,000 hours of combustion durability, and define a catalytic reactor system with a high probability of successful integration into an automotive gas turbine engine. Fourteen different catalytic reactor concepts were evaluated, leading to the selection of one for a durability combustion test with diesel fuel for combustion conditions. Eight additional catalytic reactors were evaluated and one of these was successfully combustion tested on propane fuel. This durability reactor used graded cell honeycombs and a combination of noble metal and metal oxide catalysts. The reactor was catalytically active and structurally sound at the end of the durability test.

Tong, H.↗

Environmental testing of a Q-switched Nd:YLF laser and a Nd:YAG ring laser

A Q-switched Nd:YLF laser (model 110-02) and a Nd:YAG ring laser (model 120-04) from Lightwave Electronics were subjected to thermal and vibration tests similar to what can be expected during launch and flight on a spacecraft. Even though these lasers were not designed for space flight, environmental tests were performed to identify major design weaknesses. Laser performance (output power, energy, pulsewidth, lasing threshold etc.) were measured prior to and after thermal vibration tests. Average output power of the Q-switched laser degraded 15-20 percent after thermal tests and an additional 20-25 percent after vibration tests. Post diagnostic tests revealed that degradation of the Q-switched laser was due to misalignment of pump focusing optics and the laser cavity.

Robinson, D. L.↗

Real-time Hardware-in-the-Loop Evaluation of a Partially Turboelectric Propulsion Control Design

In support of aviation fuel burn and emission reduction goals, NASA is pursuing high-payoff research investments that promise to transform aviation. This includes investments in Electrified Aircraft Propulsion (EAP). Multiple technology challenges must be addressed to unlock the full potential of EAP. This includes addressing challenges related to propulsion controls, which will be vital for ensuring efficient coordinated operation of EAP subsystems. This paper presents results from real-time hardware-in-the-loop testing of a control design for a single aisle partially-turboelectric aircraft propulsion concept conducted at the NASA Electric Aircraft Testbed (NEAT) facility. The control system under test is designed for a propulsion concept consisting of two wing-mounted turbofan engines that produce thrust and generate electrical power to drive a boundary layer ingesting tailfan propulsor via an electrical motor. An integrated control strategy is applied to ensure coordinated operation of the turbofan and tailfan subsystems during steady-state and transient operation throughout the flight envelope. The NEAT test of this integrated control design consists of a partially hardware-in-the-loop, partially simulated configuration. A subscale representation of the electrical system design is implemented in hardware and mechanically coupled to electric machines that emulate turbomachinery and propulsor shaft dynamics. The hardware configuration is then operated under the control of a real-time computer application that runs a simulation of the propulsion system and the developed control logic. The NEAT facility test campaign includes a series of experiments that subject the control design to throttle transients conducted throughout the flight envelope and full-flight mission profiles. Testing under simulated performance degradation is also conducted to evaluate control design robustness. This includes constant and abrupt changes in degradation levels. Results from the hardware-in-the-loop test are presented and shown to be in good agreement with pre-test simulation predictions demonstrating the efficacy of the integrated control design approach.

Electrified Aircraft Propulsion↗

Real-time Hardware-in-the-Loop Evaluation of a Partially Turboelectric Propulsion Control Design

In support of aviation fuel burn and emission reduction goals, NASA is pursuing high-payoff research investments that promise to transform aviation. This includes investments in Electrified Aircraft Propulsion (EAP). Multiple technology challenges must be addressed to unlock the full potential of EAP. This includes addressing challenges related to propulsion controls, which will be vital for ensuring efficient coordinated operation of EAP subsystems. This paper presents results from real-time hardware-in-the-loop testing of a control design for a single aisle partially-turboelectric aircraft propulsion concept conducted at the NASA Electric Aircraft Testbed (NEAT) facility. The control system under test is designed for a propulsion concept consisting of two wing-mounted turbofan engines that produce thrust and generate electrical power to drive a boundary layer ingesting tailfan propulsor via an electrical motor. An integrated control strategy is applied to ensure coordinated operation of the turbofan and tailfan subsystems during steady-state and transient operation throughout the flight envelope. The NEAT test of this integrated control design consists of a partially hardware-in-the-loop, partially simulated configuration. A subscale representation of the electrical system design is implemented in hardware and mechanically coupled to electric machines that emulate turbomachinery and propulsor shaft dynamics. The hardware configuration is then operated under the control of a real-time computer application that runs a simulation of the propulsion system and the developed control logic. The NEAT facility test campaign includes a series of experiments that subject the control design to throttle transients conducted throughout the flight envelope and full-flight mission profiles. Testing under simulated performance degradation is also conducted to evaluate control design robustness. This includes constant and abrupt changes in degradation levels. Results from the hardware-in-the-loop test are presented and shown to be in good agreement with pre-test simulation predictions demonstrating the efficacy of the integrated control design approach.

Electrified Aircraft Propulsion↗

Study of toluene stability for an Organic Rankine Cycle (ORC) space-based power system

The design, fabrication, assembly, and endurance operation of a dynamic test loop, built to evaluate the thermal stability of a proposed Organic Rankine Cycle (ORC) working fluid, is discussed. The test fluid, toluene, was circulated through a heater, simulated turbine, regenerator, condenser and pump to duplicate an actual ORC system. The maximum nominal fluid temperature, 750 F, was at the turbine simulator inlet. Samples of noncondensible gases and liquid toluene were taken periodically during the test. The samples were analyzed to identify the degradation products formed and the quantity of these products. From these data it was possible to determine the degradation rate of the working fluid and the generation rate of noncondensible gases. A further goal of this work was to relate the degradation observed in the dynamic operating loop to degradation obtained in isothermal capsule tests. This relationship was the basis for estimating the power loop degradation in the Space Station Organic Rankine Cycle system.

Havens, Vance↗