Search NASA⌕ Search

SEARCH · Search NASA

Results for “grating array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Imaging spectrometer/camera having convex grating

An imaging spectrometer has fore-optics coupled to a spectral resolving system with an entrance slit extending in a first direction at an imaging location of the fore-optics for receiving the image, a convex diffraction grating for separating the image into a plurality of spectra of predetermined wavelength ranges; a spectrometer array for detecting the spectra; and at least one concave sperical mirror concentric with the diffraction grating for relaying the image from the entrance slit to the diffraction grating and from the diffraction grating to the spectrometer array. In one embodiment, the spectrometer is configured in a lateral mode in which the entrance slit and the spectrometer array are displaced laterally on opposite sides of the diffraction grating in a second direction substantially perpendicular to the first direction. In another embodiment, the spectrometer is combined with a polychromatic imaging camera array disposed adjacent said entrance slit for recording said image.

Reininger, Francis M.↗

Spectrometer Technology Development for Far-Infrared Line Surveys

The objective of this proposal was to build and demonstrate a new direct-detection diffraction grating concept and couple it to an array of bolometers. The spectrometer was to be built around a parallel-plate waveguide diffraction grating, WaFIRS: Waveguide Far-InfraRed Spectrometer. The grating is two dimensional in nature, which provides a compact configuration to suit NASA s needs for cryogenic spectrometers for future opportunities, such as infrared/submillimeter spectrometers for a suborbital balloon platform, for SOFIA, for SPICA (a Japanese satellite), and for SAFIR. Our goal was to build a spectrometer (Z-Spec) for 1.0 - 1.5 mm and demonstrate spectral resolution, throughput, and background-limited performance. This grant would partially cover the expenses and we were subsequently awarded a second grant, NAGS-12788, to complete the project. We have one-year received a no-cost extension on NAG.5-12788, to be completed in 3/31/06.

Glenn, Jason↗

HiRES - High Resolution Extreme Ultraviolet Spectroheliometer toroidal diffraction grating performance evaluation

The ray-tracing results presented characterize the theoretically achievable EUV performance of the HiRES instrument. The effects of optical system misalignment on spectrograph images, and the laboratory results for two f/15 toroidal diffraction gratings that employ a multianode microchannel array, are also presented. Interferometric studies of toroidal figure accuracy, as well as optical and electron microscopy investigations of surface quality, are discussed. While the current toroidal gratings are noted to furnish good imaging across a wide wavelength range, they exhibit excessive EUV scatter, as well as spectral ghosting.

Berger, Thomas E.↗

UV-Enabled Defect Engineering in Multilayer GaSe and InSe and UV Writing of the Grating Pattern

III–VI post-transition-metal chalcogenides are layered semiconductor materials that exhibit direct band gaps in multilayers. Defect engineering is essential in 2D layered semiconductors for functional devices. Here, in this work, we report defect engineering in multilayer gallium selenide (GaSe) and indium selenide (InSe), where defects generated by ultraviolet (UV, 325 nm) laser irradiation result in an additional photoluminescence (PL) line. The additional PL line is due to defect-bound excitons. Characteristics of the defect emission are similar in GaSe and InSe samples subjected to UV irradiation, air annealing, and hydrostatic pressure. Two-beam UV interference was applied to create grating patterns with a periodic array of low and high densities of defects in GaSe. Density functional theory has identified the defect type in GaSe. The results provide valuable insights into defect generation and UV scribing of photonic circuits in 2D Se-based multilayers for optical integration in a 2D platform.

2D multilayered materials↗

Prototyping of 2D and 3D photonic nanodevices by Electron Beam Lithography (CRADA Final Report)

Team developed a large area and fast electron beam lithographic for patterning visible wavelength optical materials to create 2 or 3 dimensional gratings and metasurfaces. Metasurfaces,are arrays of nanoantennas or optical resonators, are dielectric or plasmonic structures that allow control of the amplitude, phase, and polarization of light by locally modulating its wavefront The team was able to write a 1cm2 pattern with resolution better than 30 nm without visible discontinuities in the pattern. Performance to this specification allowed prototyping of optical lenses for production applications such as augmented reality goggles (optical displays) and other applications for visible light manipulations

36 MATERIALS SCIENCE↗

The Imaging Spectrometric Observatory

Design and performance features of the Imaging Spectrometric Observatory (ISO) first flown on Spacelab 1 for atmospheric, earth surface and stellar monitoring are outlined. The ISO has five grating spectrometers fitted with CCD arrays for simultaneously gathering spectral and spatial data. The instrument covered the 300-12,700 A range on the Spacelab 1 flight, when it was mounted on a pallet and used for atmospheric scans at high solar zenith angles. A future mission is planned which will include limb-viewing of OH, NO, ClO and NO2 radicals in the middle atmosphere to complement the data collected in the Upper Atmosphere Research Satellite program. Technical details are presented of the instrument components and ground- and balloon-borne test results.

Torr, D. G.↗

Dispersive spectroscopy on AXAF

The designs of two transmission grating spectrometers and a Bragg crystal spectrometer that are being developed for the Advanced X-ray Astrophysics Facility (AXAF) are described. The gratings, which are composed of arrays of small facets mounted on plates which can be inserted immediately behind the AXAF telescope, divide the AXAF energy band (80 eV-10 keV) into three regions and attain very high resolving powers for point sources. The Bragg Crystal Spectrometer (BCS) is a focal plane instrument, in which X-rays that satisfy the Bragg law are reflected from a curved crystal which refocuses the beam onto an imaging detector. The BCS achieves the highest spectral resolutions of the AXAF spectrometers: for E values between 500 and 1600 eV, the FWHM of a narrow line is less than 1 eV.

Markert, T. H.↗

Raman Spectroscopic Characterization of the Feldspars: Implications for Surface Mineral Characterization in Planetary Exploration

The availability in the last decade of improved Raman instrumentation using small, stable, intense lasers, sensitive CCD array detectors, and advanced fast grating systems enabled us to develop the Mars Microbeam Raman Spectrometer (MMRS), a field-portable Raman spectrometer with precision and accuracy capable of identifying minerals and their different compositions. For example, we can determine Mg cation ratios in pyroxenes and olivines to +/-0.1 on the basis of Raman peak positions. Feldspar is another major mineral formed in igneous systems whose characterization is important for determining rock petrogenesis and alteration. From their Raman spectral pattern, feldspars can be readily distinguished from ortho- and chain-silicates and from other tecto-silicates such as quartz and zeolites. We show here how well Raman spectral analysis can distinguish among members within the feldspar group.

Freeman, J. J.↗

Simultaneous NuSTAR/Chandra Observations of the Bursting Pulsar GRO J1744-28 During its Third Reactivation

We report on a 10 ks simultaneous Chandra/High Energy Transmission Grating (HETG)-Nuclear Spectroscopic Telescope Array (NuSTAR) observation of the Bursting Pulsar, GRO J1744-28, during its third detected outburst since discovery and after nearly 18 yr of quiescence. The source is detected up to 60 keV with an Eddington persistent flux level. Seven bursts, followed by dips, are seen with Chandra, three of which are also detected with NuSTAR. Timing analysis reveals a slight increase in the persistent emission pulsed fraction with energy (from 10% to 15%) up to 10 keV, above which it remains constant. The 0.5-70 keV spectra of the persistent and dip emission are the same within errors and well described by a blackbody (BB), a power-law (PL) with an exponential rolloff, a 10 keV feature, and a 6.7 keV emission feature, all modified by neutral absorption. Assuming that the BB emission originates in an accretion disk, we estimate its inner (magnetospheric) radius to be about 4 x 10(exp 7) cm, which translates to a surface dipole field B approximately 9 x 10(exp 10) G. The Chandra/HETG spectrum resolves the 6.7 keV feature into (quasi-)neutral and highly ionized Fe XXV and Fe XXVI emission lines. XSTAR modeling shows these lines to also emanate from a truncated accretion disk. The burst spectra, with a peak flux more than an order of magnitude higher than Eddington, are well fit with a PL with an exponential rolloff and a 10 keV feature, with similar fit values compared to the persistent and dip spectra. The burst spectra lack a thermal component and any Fe features. Anisotropic (beamed) burst emission would explain both the lack of the BB and any Fe components.

pulsars: general aEuro" stars: individual (GRO J17↗

Compact LWIR Polarimeter for Cirrus Ice Properties

A miniaturized long-wave InfraRed (LWIR) spectro-polarimeter is being developed as a prototype for the Compact Submm-Wave and LWIR Polarimeters (SWIRP) project. The polarimeter in development is a compact (20x20x40 cm) conical-scan instrument to measure the polarimetric radiation from ice cloud scattering at mm-submm (220 and 680 GHz) and IR (8.6, 11, and 12 m) bands. The LWIR polarimeter will provide a series of polarization measurements across the 8.5 - 12.5 micron band, measuring the full set of linear Stokes parameters (I, Q, U) as a function of wavelength. The spectro-polarimeter uses a combination of birefringent crystals, a Wollaston prism, a diraction grating, and an uncooled microbolometer array to measure both the degree and angle of linear polarization across the spectral bandwidth by modulating the polarization ux in wavelength with a high order retarder.

LWIR↗

Surface plasmon polariton pulse shaping via two-dimensional Bragg grating pairs

Abstract We demonstrate control over the spatial and temporal properties of surface plasmon polaritons (SPPs) launched from nanohole arrays in silver. The arrays provide wave vector matching to allow the conversion of free-space photons into counter-propagating SPPs. SPPs launched from multiple arrays interfere at well-defined spatial positions, and the interference fringes form an all-SPP periodic nano-optical grating which evolves in space and time as the SPPs propagate. The spatio-temporal characteristics of the optical grating can be tuned through various nanohole array parameters such as tilt angle, separation, and array width. In addition, we examine multiperiodic arrays (MPAs) consisting of arrays with different pitches placed adjacent to one another. This platform allows the temporal interference of SPPs with different central wavelengths to be tailored through the MPA geometric and structural parameters. The temporal interference serves as an encoded signal, whereby the frequency components can be controlled by the array properties.

79 ASTRONOMY AND ASTROPHYSICS↗

Focal plane scanner with reciprocating spatial window

A focal plane scanner having a front objective lens, a spatial window for selectively passing a portion of the image therethrough, and a CCD array for receiving the passed portion of the image. All embodiments have a common feature whereby the spatial window and CCD array are mounted for simultaneous relative reciprocating movement with respect to the front objective lens, and the spatial window is mounted within the focal plane of the front objective. In a first embodiment, the spatial window is a slit and the CCD array is one-dimensional, and successive rows of the image in the focal plane of the front objective lens are passed to the CCD array by an image relay lens interposed between the slit and the CCD array. In a second embodiment, the spatial window is a slit, the CCD array is two-dimensional, and a prism-grating-prism optical spectrometer is interposed between the slit and the CCD array so as to cause the scanned row to be split into a plurality of spectral separations onto the CCD array. In a third embodiment, the CCD array is two-dimensional and the spatial window is a rectangular linear variable filter (LVF) window, so as to cause the scanned rows impinging on the LVF to be bandpass filtered into spectral components onto the CCD array through an image relay lens interposed between the LVF and the CCD array.

Mao, Chengye↗

Femtosecond photoemission electron microscopy of surface plasmon polariton beam steering via nanohole arrays

Directional control over surface plasmon polariton (SPP) waves is a prerequisite for the development of miniaturized optical circuitry. Here, the efficacy of single and dual component SPP steering elements is explored through photoemission electron microscopy. Our imaging scheme relies on two-color photoemission and counter-propagating SPP generation, which collectively allow SPPs to be visualized in real space. Wave-vector difference mixing between two-dimensional arrays of nanoholes and photon momenta enables SPP steering with directionality governed by the array lattice constant. The magnitude of grating momentum required to achieve counter-propagation guarantees efficient steering over the full range of the negative half-space. In our dual component configuration, separate SPP generation and Bragg diffraction based steering optics are employed. We find that array Bragg planes principally influence the SPP angles through the array band structure, which allows us to visualize both positive and negative refractory waves.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gratings and Random Reflectors for Near-Infrared PIN Diodes

Crossed diffraction gratings and random reflectors have been proposed as means to increase the quantum efficiencies of InGaAs/InP positive/intrinsic/ negative (PIN) diodes designed to operate as near-infrared photodetectors. The proposal is meant especially to apply to focal-plane imaging arrays of such photodetectors to be used for near-infrared imaging. A further increase in quantum efficiency near the short-wavelength limit of the near-infrared spectrum of such a photodetector array could be effected by removing the InP substrate of the array. The use of crossed diffraction gratings and random reflectors as optical devices for increasing the quantum efficiencies of quantum-well infrared photodetectors (QWIPs) was discussed in several prior NASA Tech Briefs articles. While the optical effects of crossed gratings and random reflectors as applied to PIN photodiodes would be similar to those of crossed gratings and random reflectors as applied to QWIPs, the physical mechanisms by which these optical effects would enhance efficiency differ between the PIN-photodiode and QWIP cases: In a QWIP, the multiple-quantum-well layers are typically oriented parallel to the focal plane and therefore perpendicular or nearly perpendicular to the direction of incidence of infrared light. By virtue of the applicable quantum selection rules, light polarized parallel to the focal plane (as normally incident light is) cannot excite charge carriers and, hence, cannot be detected. A pair of crossed gratings or a random reflector scatters normally or nearly normally incident light so that a significant portion of it attains a component of polarization normal to the focal plane and, hence, can excite charge carriers. A pair of crossed gratings or a random reflector on a PIN photodiode would also scatter light into directions away from the perpendicular to the focal plane. However, in this case, the reason for redirecting light away from the perpendicular is to increase the length of the optical path through the detector to increase the probability of absorption of photons and thereby increase the resulting excitation of charge carriers. A pair of crossed gratings or a random reflector according to the proposal would be fabricated as an integral part of photodetector structure on the face opposite the focal plane (see figure). In the presence of crossed gratings, light would make four passes through the device before departing. In the presence of a random reflector, a significant portion of the light would make more than four passes: After each bounce, light would be scattered at a different random angle, and would have a chance to escape only when it was reflected, relative to the normal, at an angle less than the critical angle for total internal reflection. Given the indices of refraction of the photodiode materials, this angle would be about 17 . This amounts to a very narrow cone for escape of trapped light.

Gunapala, Sarath↗

Fiber-coupled high resolution infrared array spectrometer for the Kuiper Airborne Observatory

A novel cryogenic grating spectrometer (FCAS) is being designed for observations of volatiles in cometary and planetary atmospheres, and in newly forming planetary systems. The instrument features two-dimensional detector arrays coupled to a high-dispersion echelle by infrared fibers, and will achieve a spectral resolving power of about 40,000. The primary observational platform for this instrument will be the Kuiper Airborne Observatory, but it will also be configured for use at ground-based observatories. Initially, the spectrometer will use a 58 x 62, 1- to 5-micron InSb array. Larger-format IR arrays and arrays of different composition, will later be incorporated as they become available. The instrument will be used in two modes. The first uses a large format IR array in the spectral image plane for the customary one-dimensional spectral-one-dimensional spatial coverage. In the second mode, a massive, coherent bundle of infrared transmitting ZrF4 fibers will be installed after the dispersive element, to reformat the two-dimensional array into an elongated one-dimensional array for wide spectral coverage, allowing multiple lines to be measured in a single integration with high sensitivity. The overall instrument design is discussed, and the system sensitivity is estimated.

Glenar, D. A.↗

Mars Array Technology Experiment Developed to Test Solar Arrays on Mars

Solar arrays will be the power supply for future missions to the planet Mars, including landers, rovers, and eventually human missions to explore the Martian surface. Until Mars Pathfinder landed in July 1997, no solar array had been used on the surface. The MATE package is intended to measure the solar energy reaching the surface, characterize the Martian environment to gather the baseline information required for designing power systems for long-duration missions, and to quantify the performance and degradation of advanced solar cells on the Martian surface. To measure the properties of sunlight reaching the Martian surface, MATE incorporates two radiometers and a visible/NIR spectrometer. The radiometers consist of multiple thermocouple junctions using thin-film technology. These devices generate a voltage proportional to the solar intensity. One radiometer measures the global broadband solar intensity, including both the direct and scattered sunlight, with a field of view of approximately 130. The second radiometer incorporates a slit to measure the direct (unscattered) intensity radiation. The direct radiometer can only be read once per day, with the Sun passing over the slit. The spectrometer measures the global solar spectrum with two 256-element photodiode arrays, one Si sensitive in the visible range (300 to 1100 nm), and a second InGaAs sensitive to the near infrared (900 to 1700 nm). This range covers 86 percent of the total energy from the Sun, with approximately 5-nm resolution. Each photodiode array has its own fiber-optic feed and grating. Although the purpose of the MATE is to gather data useful in designing solar arrays for Mars surface power systems, the radiometer and spectrometer measurements are expected to also provide important scientific data for characterizing the properties of suspended atmospheric dust. In addition to measuring the solar environment of Mars, MATE will measure the performance of five different individual solar cell types and two different solar cell strings, to qualify advanced solar cell types for future Mars missions. The MATE instrument, designed for the Mars-2001 Surveyor Lander mission, contains a capable suite of sensors that will provide both scientific information as well as important engineering data on the operation of solar power systems on Mars. MATE will characterize the intensity and spectrum of the solar radiation on Mars and measure the performance of solar arrays in the Mars environment. MATE flight hardware was built and tested at the NASA Glenn Research Center and is ready for flight.

Landis, Geoffrey A.↗

Single laser beam of spatial coherence from an array of GaAs lasers - Free-running mode

Spatially coherent radiation from a monolithic array of three GaAs lasers in a free-running mode is reported. The lasers, with their mirror faces antireflection coated, are operated in an external optical cavity built of spherical lenses and plane mirrors. The spatially coherent-beam formation makes use of the Fourier-transformation property of the internal lenses. Transverse mode control is accomplished by a spatial filter. The optical cavity is similar to that used for the phase-controlled mode of spatially coherent-beam formation; only the spatial filters are different. In the far field (when restored by an external lens), the intensities of the lasers in the array are concentrated in a single laser beam of spatial coherence, without any grating lobes. The far-field distribution of the laser array in the free-running mode differs significantly from the interference pattern of the phase-controlled mode. The modulation characteristics of the optical waveforms of the two modes are also quite different because modulation is related to the interaction of the spatial filter with the longitudinal modes of the laser array within the optical cavity. The modulation of the optical waveform of the free-running mode is nonperiodic, confirming that the fluctuations of the optical fields of the lasers are random.

Philipp-Rutz, E. M.↗

Mathematical Simulation for Integrated Linear Fresnel Spectrometer Chip

A miniaturized solid-state optical spectrometer chip was designed with a linear gradient-gap Fresnel grating which was mounted perpendicularly to a sensor array surface and simulated for its performance and functionality. Unlike common spectrometers which are based on Fraunhoffer diffraction with a regular periodic line grating, the new linear gradient grating Fresnel spectrometer chip can be miniaturized to a much smaller form-factor into the Fresnel regime exceeding the limit of conventional spectrometers. This mathematical calculation shows that building a tiny motionless multi-pixel microspectrometer chip which is smaller than 1 cubic millimter of optical path volume is possible. The new Fresnel spectrometer chip is proportional to the energy scale (hc/lambda), while the conventional spectrometers are proportional to the wavelength scale (lambda). We report the theoretical optical working principle and new data collection algorithm of the new Fresnel spectrometer to build a compact integrated optical chip.

Park, Yeonjoon↗