Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat wave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Plasma heating by electron cyclotron wave and the temperature effects on lower hybrid current drive on EAST

This paper presents the progress in the long—pulse operation of the electron cyclotron (EC) system and the achievements in high—electron temperature plasmas by the combined EC and lower hybrid (LH) waves heating since the EC system was built in 2015. An electron temperature of up to 12 keV with a duration over 100 s was realized by the simultaneous heating of EC and LH waves at the line-averaged density ${\bar n_{\text{e}}}$ ~1.8 × 10 19 m –3 . The plasma heating effect strongly depends on the location of EC power deposition. H-mode plasmas with solely EC wave auxiliary heating have been obtained on EAST for the first time. These H-mode discharges show an enhanced confinement factor H 98(y,2) around 1.0, which is higher than the previous H-mode using LH power alone (Xu et al 2011 Nucl. Fusion 51 072001). The total heating power is very close to the threshold value for L–H transition according to the international tokamak scaling. In addition to the temperature effects inside the separatrix, higher electron temperature produced by EC wave is found to reduce the LH power loss in the scrape-off layer due to collisional absorption, which is beneficial to further increase the LH current drive efficiency. Ray-tracing/Fokker–Planck modeling results indicate that higher electron temperature can shorten the LH wave propagation on EAST in a multiple-pass regime, thus decreasing the collisional dissipation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THEMIS Observations of the Magnetopause Electron Diffusion Region: Large Amplitude Waves and Heated Electrons

We present the first observations of large amplitude waves in a well-defined electron diffusion region based on the criteria described by Scudder et al at the subsolar magnetopause using data from one Time History of Events and Macroscale Interactions during Substorms (THEMIS) satellite. These waves identified as whistler mode waves, electrostatic solitary waves, lower hybrid waves, and electrostatic electron cyclotron waves, are observed in the same 12 s waveform capture and in association with signatures of active magnetic reconnection. The large amplitude waves in the electron diffusion region are coincident with abrupt increases in electron parallel temperature suggesting strong wave heating. The whistler mode waves, which are at the electron scale and which enable us to probe electron dynamics in the diffusion region were analyzed in detail. The energetic electrons (approx. 30 keV) within the electron diffusion region have anisotropic distributions with T(sub e(right angle))/T(sub e(parallel)) > 1 that may provide the free energy for the whistler mode waves. The energetic anisotropic electrons may be produced during the reconnection process. The whistler mode waves propagate away from the center of the "X-line" along magnetic field lines, suggesting that the electron diffusion region is a possible source region of the whistler mode waves.

magnetopause and boundary layers↗

Ion heating by waves with frequencies below the ion gyrofrequency

Ion heating by broadband and coherent waves with relatively small amplitude and frequencies below the ion gyrofrequency is examined. The theoretical results, verified by test particle calculations, show that such waves can heat ions to high energies, and in particular produce the ion conic distributions observed in the earth's magnetosphere. The model utilized differs from other approaches in that neither quasi-linear theory nor stochastic acceleration in a large amplitude wave are used to heat ions. This heating mechanism may be significant in other geophysical and astrophysical environments.

Temerin, M.↗

Development and Testing of a Refractory Millimeter-Wave Absorbent Heat Exchanger

Central to the Millimeter-Wave Thermal Launch System (MTLS) is the millimeter-wave absorbent heat exchanger. We have developed metallic and ceramic variants, with the key challenge being the millimeter-wave absorbent coatings for each. The ceramic heat exchanger came to fruition first, demonstrating for the first time 1800 K peak surface temperatures under illumination by a 110 GHz Gaussian beam. Absorption efficiencies of up to 80 are calculated for mullite heat exchanger tubes and up to 50 are calculated for alumina tubes. These are compared with estimates based on stratified layer and finite element analyses. The problem of how to connect the 1800 K end of the ceramic tubes to a graphite outlet manifold and nozzle is solved by press fitting, or by threading the ends of the ceramic tubes and screwing them into place. The problem of how to connect the ceramic tubes to a metallic or nylon inlet pipe is solved by using soft compliant PTFE and PVC tubes that accommodate thermal deformations of the ceramic tubes during startup and operation. We show the resulting heat exchangers in static tests using argon and helium as propellants.

propulsion↗

Impacts of Snow Darkening by Absorbing Aerosols on Eurasian Climate

The deposition of absorbing aerosols on snow surfaces reduces snow-albedo and allows snowpack to absorb more sunlight. This so-called snow darkening effect (SDE) accelerates snow melting and leads to surface warming in spring. To examine the impact of SDE on weather and climate during late spring and early summer, two sets of NASA GEOS-5 model simulations with and without SDE are conducted. Results show that SDE-induced surface heating is particularly pronounced in Eurasian regions where significant depositions of dust transported from the North African deserts, and black carbon from biomass burning from Asia and Europe occur. In these regions, the surface heating due to SDE increases surface skin temperature by 3-6 degrees Kelvin near the snowline in spring. Surface energy budget analysis indicates that SDE-induced excess heating is associated with a large increase in surface evaporation, subsequently leading to a significant reduction in soil moisture, and increased risks of drought and heat waves in late spring to early summer. Overall, we find that rainfall deficit combined with SDE-induced dry soil in spring provide favorable condition for summertime heat waves over large regions of Eurasia. Increased frequency of summer heat waves with SDE and the region of maximum increase in heat-wave frequency are found along the snow line, providing evidence that early snowmelt by SDE may increase the risks of extreme summer heat wave. Our results suggest that climate models that do not include SDE may significantly underestimate the effect of global warming over extra-tropical continental regions.

GEOS-5↗

Thermal Resilience of Residential Building with Thermally Anisotropic Building Envelope Connected to Geothermal Sources

Heat waves and cold snaps have become more frequent and more intense because of climate change. A heat wave and a cold snap are a period of excessively hot and cold weather, respectively, that poses severe risks to building occupants’ health, especially for vulnerable people. They increase electrical energy consumption and put high stress on the grid which leads to potential power outages. Therefore, it is critical to assess and actively improve the thermal resilience of buildings to cope with heat waves, cold snaps, and power outages. The thermally anisotropic building envelope (TABE) is a novel active building envelope that can save energy while maintaining thermal comfort in buildings by redirecting heat and coolness from building envelopes to hydronic loops. When connecting to a ground thermal loop (GL), TABE can utilize the relatively stable temperature of the ground to protect the indoor environment during heat waves and cold snaps. This study assesses the thermal resilience of residential buildings that installed TABE and used ground thermal energy to supply the hydronic loops, abbreviated as ground thermal loop or TABE+GL. The simulation and analysis are conducted for the US Department of Energy prototype single-family detached residential building in the hot climate of Miami, Florida and Tucson, Arizona, and the cold climate of Denver, Colorado, and Rochester, Minnesota. Heat waves and cold snaps were obtained from the historical weather data of 1998-2020 for the studied regions. Three thermal resilience metrics, including the standard effective temperature (SET) degree-hours, the Heat Index, and the Hours of Safety (HOS) were used to quantify the effect of TABE+GL. The results showed that buildings installed TABE+GL could significantly reduce the average SET degree-hours above 30°C, increase HOS, and greatly improve thermal resilience.

Shen, Zhenglai↗

The possible role of MHD waves in heating the solar corona

The possible role of waves in the heating of the solar corona has been investigated. A general dispersion relation has been derived for waves propagating in a homogeneous plasma subject to dissipation by viscosity and thermal conduction. The dissipation mechanisms have been incorporated self-consistently into the equations, and no assumptions about the strength of the damping have been made. Solutions of the sixth-order dispersion relation provide information on how the damping of both slow and fast mode waves depends upon the plasma density, temperature, field strength, and angle of propagation relative to the background magnetic field. We provide a detailed comparison to the standard approach, which is to solve for the wave quantities in the absence of dissipation and then to use these quantities in expressions for the heating due to viscosity and thermal conduction.

Porter, Lisa J.↗

Experimental Study of Shock Wave Interference Heating on a Cylindrical Leading Edge

An experimental study of shock wave interference heating on a cylindrical leading edge representative of the cowl of a rectangular hypersonic engine inlet at Mach numbers of 6.3, 6.5, and 8.0 is presented. Stream Reynolds numbers ranged from 0.5 x 106 to 4.9 x 106 per ft. and stream total temperature ranged from 2100 to 3400 R. The model consisted of a 3" dia. cylinder and a shock generation wedge articulated to angles of 10, 12.5, and 15 deg. A fundamental understanding was obtained of the fluid mechanics of shock wave interference induced flow impingement on a cylindrical leading edge and the attendant surface pressure and heat flux distributions. The first detailed heat transfer rate and pressure distributions for two dimensional shock wave interference on a cylinder was provided along with insight into the effects of specific heat variation with temperature on the phenomena. Results show that the flow around a body in hypersonic flow is altered significantly by the shock wave interference pattern that is created by an oblique shock wave from an external source intersecting the bow shock wave produced in front of the body.

Wieting, Allan R.↗

The possible role of high-frequency waves in heating solar coronal loops

We investigate the role of high-frequency waves in the heating of solar active region coronal loops. We assume a uniform background magnetic field, and we introduce a density stratification in a direction perpendicular to this field. We focus on ion compressive viscosity as the damping mechanism of the waves. We incorporate viscosity self-consistently into the equations, and we derive a dispersion relation by adopting a slab model, where the density inside the slab is greater than that outside. Such a configuration supports two types of modes: surface waves and trapped body waves. In order to determine under what conditions these waves may contribute to the heating of active regions, we solve our dispersion relation for a range of densities, temperatures, magnetic field strengths, density ratios, wavevector magnitudes, wavevector ratios, and slab widths. We find that surface waves exhibit very small damping, but body waves can potentially damp at rates needed to balance radiative losses. However, the required frequencies of these body waves are very high. For example, the wave frequency must be at least 5.0/s for a slab density of 10(exp 9,5)/cc, a slab temperature of 10(exp 6,5) K, a field strength of 100 G, and a density ratio of 5. For a slab density of 10(exp 10)/cc, this frequency increases to 8.8/s. Although these frequencies are very high, there in no observational evidence to rule out their existence, and they may be generated both below the corona and at magnetic reconnection sites in the corona. However, we do find that, for slab densities of 10(exp 10)/cc or less, the dissipation of high-frequency waves will be insufficient to balance the radiative losses if the magnetic field strength exceeds roughly 200 G. Because the magnetic field is known to exceed 200 G in many active region loops, particularly low-lying loops and loops emanating from sunspots, it is unlikely that high-frequency waves can provide sufficient heating in these regions.

Porter, Lisa J.↗

The solar probe and coronal dynamics

The discovery of coronal holes led to basic changes in ideas about the structure of the low corona and its expansion into the solar wind. The nature of the energy flux is not understood. Current ideas include enhanced thermal conductivities, extended MHD wave heating, and wave momentum transfer, all in rapidly diverging geometries. There is little feel for the relative importance of these processes. The Solar Probe, with its penetration deep into the solar corona, could lead to observational constraints on their relative importance, and thus to an understanding of the origin of the solar wind. Observations from the Solar Probe will also bear on such questions as to whether small scale "intrastream" structure is common close to the Sun in open field-line regions, whether the properties of the wind are pronouncedly different over closed and open field-line regions at five solar radii, and many others. The resolution of these questions requires measurements of the magnetic field and of the proton and electron distribution functions.

Belcher, J.↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

A new way to convert Alfven waves into heat in solar coronal holes - Intermittent magnetic levitation

In our recent analysis of Alfven wave reflection in solar coronal holes, we found evidence that coronal holes are heated by reflected Alfven waves. This result suggests that the reflection is inherent to the process that dissipates these Alfven waves into heat. We propose a novel dissipation process that is driven by the reflection, and that plausibly dominates the heating in coronal holes.

Moore, R. L.↗

The Source of Alfven Waves That Heat the Solar Corona

We suggest a source for high-frequency Alfven waves invoked in coronal heating and acceleration of the solar wind. The source is associated with small-scale magnetic loops in the chromospheric network.

Alfven Waves Heat Solar Corona solar wind solar wi↗

Pressure Fluctuations due to ‘Trapped Waves’ in Heated Jets

An experimental study was conducted to investigate the presence and characteristics of ‘trapped waves’ in the near field of a small axisymmetric jet at heated conditions. Trapped waves occur within the potential core of compressible jets and manifest as distinct peaks in the unsteady pressure spectra measured just outside the jet near the nozzle exit. The existence and properties of the trapped wave spectral peaks in round and rectangular jets of various sizes in subsonic and supersonic conditions were studied in our recent experiments, at cold conditions [7]. The current work extends the study to heated jets. Pressure fluctuation spectra near the nozzle exit are analyzed for a small (D = 6.35 mm) axisymmetric jet at stagnation temperature ratios up to 1.6. It is shown that trapped waves continue to persist in heated jets. At sufficiently high Mach numbers, one of the trapped wave harmonics emerges as screech tone, a behavior consistent with that observed in cold jets. For a given Mach number, the frequencies of both trapped waves and screech increase with jet temperature with no significant change occurring in their amplitudes. The Strouhal numbers based on jet diameter for the trapped waves and screech continue to follow similar scaling laws as observed previously with cold jets.

aeroacoustics↗

Experimental study of shock wave interference heating on a cylindrical leading edge at Mach 6 and 8

This paper presents the details of an experimental study of shock wave interference heating on a cylindrical leading edge representative of the cowl of a rectangular hypersonic engine inlet. The study was conducted at Mach numbers of 6.3, 6.5 and 8.0. This study has provided the first (1) detailed pressure and heat transfer rate distributions for a two-dimensional shock wave interference on a cylinder and (2) insight into the effects of temperature dependent specific heats on the phenomena. The peak pressure and heat transfer rates were 10 times the undisturbed flow stagnation point levels. The peak levels and their gradients increased with Mach number. Variation in specific heats and hence the ratio of specific heats with temperature manifest in slightly lower loads and amplification factors than for corresponding perfect gas conditions.

Wieting, Allan R.↗

Disentangling the mechanism of temperature and water vapor modulation on ozone under a warming climate

Temperature and water vapor have been considered as important factors affecting ozone concentrations, however, their synergistic effect on ozone, as well as its response to a warming climate remains unclear. Here, numerical experiments with different combinations of climate and emissions highlighted opposite changes of annual ozone over the contiguous U.S. under scenarios with high vs. low ozone precursor emissions in the future with warming. Comparing the occurrence of heat waves on higher vs. lower ozone days, we found significant suppression of the heat wave exacerbation of ozone by anthropogenic emissions reductions. Variations of ozone with temperature (T) and water vapor (Q) over the western U.S. and southeastern U.S. in the simulations are clearly revealed through the construction of an O 3 -T-Q diagram. Based on the diagram, we further identified a T-dominant regime at higher temperatures where ozone increases with temperature increase, and a Q-dominant regime at lower temperatures where ozone decreases with temperature increase due to the negative effect of water vapor. With larger anthropogenic emission reductions, ozone may increase at a lower rate with temperature in the T-dominant regime, or even decrease with temperature in the Q-dominant regime. Our results show that with large emission reductions, substantial ozone pollution due to warming and increasing heat waves may be counteracted by water vapor, partly turning the ‘climate penalty’ on ozone into ‘climate benefit’. Hence controlling anthropogenic emissions may be an increasingly important strategy in a warmer and wetter climate to improve air quality and public health.

54 ENVIRONMENTAL SCIENCES↗

Climate Variability and Impact at NASA's Marshal Space Flight Center

Climate analysis for the Southeast U. S. has indicated that inland regions have experienced an average temperature increase of 2F since 1970. This trend is generally characterized by warmer winters with an indication of increased precipitation in the Fall season. Extended periods of limited rainfall in the Spring and Summer periods have had greater areal coverage and, at other times the number of precipitation events has been increasing. Climate model projections for the next 10-70 years indicate warmer temperatures for the Southeast U.S., particularly in the Spring and Summer, with some indication of more extremes in temperature and precipitation as shown in the table below. The realization of these types of regional climate changes in the form of extended heat waves and droughts and their subsequent stress on facilities, infrastructure, and workforce could have substantial impact on the activities and functions of NASA's Marshall Space Flight Center (MSFC) in Huntsville, Alabama. This presentation will present the results of an examination of the 100 year temperature and precipitation record for MSFC. Local warming has cause an increase in daily maximum and minimum temperatures by nearly 3F, with a substantial increase in the number of maximum temperatures exceeding 90F and a decrease in the number of days with minimum temperatures below freezing. These trends have substantial impact of the number of heating / cooling degree days for the area. Yearly precipitation totals are inversely correlated with the change in mean temperature and the frequency of heavy rain events has remain consistent with the changes in yearly totals. An extended heat wave index was developed which shows an increase in frequency of heat waves over the last 35 years and a subsequent reduction in precipitation during the heat waves. This trend will contribute to more intense drought conditions over the northern Alabama region, increasing the potential of destructive wildfires in and around the Center. MSFC has begun using this climate change information to adapt short-term and long-term plans for Center operations.

Smoot, James L.↗