Search NASA⌕ Search

SEARCH · Search NASA

Results for “kernel reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Statistical model based iterative reconstruction (MBIR) in clinical CT systems: Experimental assessment of noise performance

Purpose: To reduce radiation dose in CT imaging, the statistical model based iterative reconstruction (MBIR) method has been introduced for clinical use. Based on the principle of MBIR and its nonlinear nature, the noise performance of MBIR is expected to be different from that of the well-understood filtered backprojection (FBP) reconstruction method. The purpose of this work is to experimentally assess the unique noise characteristics of MBIR using a state-of-the-art clinical CT system. Methods: Three physical phantoms, including a water cylinder and two pediatric head phantoms, were scanned in axial scanning mode using a 64-slice CT scanner (Discovery CT750 HD, GE Healthcare, Waukesha, WI) at seven different mAs levels (5, 12.5, 25, 50, 100, 200, 300). At each mAs level, each phantom was repeatedly scanned 50 times to generate an image ensemble for noise analysis. Both the FBP method with a standard kernel and the MBIR method (Veo{sup ®}, GE Healthcare, Waukesha, WI) were used for CT image reconstruction. Three-dimensional (3D) noise power spectrum (NPS), two-dimensional (2D) NPS, and zero-dimensional NPS (noise variance) were assessed both globally and locally. Noise magnitude, noise spatial correlation, noise spatial uniformity and their dose dependence were examined for the two reconstruction methods. Results: (1) At each dose level and at each frequency, the magnitude of the NPS of MBIR was smaller than that of FBP. (2) While the shape of the NPS of FBP was dose-independent, the shape of the NPS of MBIR was strongly dose-dependent; lower dose lead to a “redder” NPS with a lower mean frequency value. (3) The noise standard deviation (σ) of MBIR and dose were found to be related through a power law of σ ∝ (dose){sup −β} with the component β ≈ 0.25, which violated the classical σ ∝ (dose){sup −0.5} power law in FBP. (4) With MBIR, noise reduction was most prominent for thin image slices. (5) MBIR lead to better noise spatial uniformity when compared with FBP. (6) A composite image generated from two MBIR images acquired at two different dose levels (D1 and D2) demonstrated lower noise than that of an image acquired at a dose level of D1+D2. Conclusions: The noise characteristics of the MBIR method are significantly different from those of the FBP method. The well known tradeoff relationship between CT image noise and radiation dose has been modified by MBIR to establish a more gradual dependence of noise on dose. Additionally, some other CT noise properties that had been well understood based on the linear system theory have also been altered by MBIR. Clinical CT scan protocols that had been optimized based on the classical CT noise properties need to be carefully re-evaluated for systems equipped with MBIR in order to maximize the method's potential clinical benefits in dose reduction and/or in CT image quality improvement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Software optimization for electrical conductivity imaging in polycrystalline diamond cutters

We previously reported on an electrical conductivity imaging instrument developed for measurements on polycrystalline diamond cutters. These cylindrical cutters for oil and gas drilling feature a thick polycrystalline diamond layer on a tungsten carbide substrate. The instrument uses electrical impedance tomography to profile the conductivity in the diamond table. Conductivity images must be acquired quickly, on the order of 5 sec per cutter, to be useful in the manufacturing process. This paper reports on successful efforts to optimize the conductivity reconstruction routine, porting major portions of it to NVIDIA GPUs, including a custom CUDA kernel for Jacobian computation.

36 MATERIALS SCIENCE↗

TU-F-18A-09: CT Number Stability Across Patient Sizes Using Virtual-Monoenergetic Dual-Energy CT

Purpose: Virtual-monoenergetic imaging uses dual-energy CT data to synthesize images corresponding to a single photon energy, thereby reducing beam-hardening artifacts. This work evaluated the ability of a commercial virtual-monoenergetic algorithm to achieve stable CT numbers across patient sizes. Methods: Test objects containing a range of iodine and calcium hydroxyapatite concentrations were placed inside 8 torso-shaped water phantoms, ranging in lateral width from 15 to 50 cm, and scanned on a dual-source CT system (Siemens Somatom Force). Single-energy scans were acquired from 70-150 kV in 10 kV increments; dual-energy scans were acquired using 4 energy pairs (low energy: 70, 80, 90, and 100 kV; high energy: 150 kV + 0.6 mm Sn). CTDIvol was matched for all single- and dual-energy scans for a given phantom size. All scans used 128×0.6 mm collimation and were reconstructed with 1-mm thickness at 0.8-mm increment and a medium smooth body kernel. Monoenergetic images were generated using commercial software (syngo Via Dual Energy, VA30). Iodine contrast was calculated as the difference in mean iodine and water CT numbers from respective regions-of-interest in 10 consecutive images. Results: CT numbers remained stable as phantom width varied from 15 to 50 cm for all dual-energy data sets (except for at 50 cm using 70/150Sn due to photon starvation effects). Relative to the 15 cm phantom, iodine contrast was within 5.2% of the 70 keV value for phantom sizes up to 45 cm. At 90/150Sn, photon starvation did not occur at 50 cm, and iodine contrast in the 50-cm phantom was within 1.4% of the 15-cm phantom. Conclusion: Monoenergetic imaging, as implemented in the evaluated commercial system, eliminated the variation in CT numbers due to patient size, and may provide more accurate data for quantitative tasks, including radiation therapy treatment planning. Siemens Healthcare.

07 ISOTOPE AND RADIATION SOURCES↗

TEMPORAL EVOLUTION AND SPATIAL DISTRIBUTION OF WHITE-LIGHT FLARE KERNELS IN A SOLAR FLARE

On 2011 September 6, we observed an X2.1-class flare in continuum and H α with a frame rate of about 30 Hz. After processing images of the event by using a speckle-masking image reconstruction, we identified white-light (WL) flare ribbons on opposite sides of the magnetic neutral line. We derive the light curve decay times of the WL flare kernels at each resolution element by assuming that the kernels consist of one or two components that decay exponentially, starting from the peak time. As a result, 42% of the pixels have two decay-time components with average decay times of 15.6 and 587 s, whereas the average decay time is 254 s for WL kernels with only one decay-time component. The peak intensities of the shorter decay-time component exhibit good spatial correlation with the WL intensity, whereas the peak intensities of the long decay-time components tend to be larger in the early phase of the flare at the inner part of the flare ribbons, close to the magnetic neutral line. The average intensity of the longer decay-time components is 1.78 times higher than that of the shorter decay-time components. If the shorter decay time is determined by either the chromospheric cooling time or the nonthermal ionization timescale and the longer decay time is attributed to the coronal cooling time, this result suggests that WL sources from both regions appear in 42% of the WL kernels and that WL emission of the coronal origin is sometimes stronger than that of chromospheric origin.

79 ASTRONOMY AND ASTROPHYSICS↗

Partially Collapsed Gibbs Samplers for Linear Inverse Problems and Applications to X-ray Imaging

Deblurring is one of the most common linear inverse problems in imaging, and most methods for deblurring an image assume that the convolution kernel, the so-called point spread function (PSF), is known or attempt to reconstruct the PSF simultaneously with the image. For many experimental imaging systems, like high energy X-ray radiography systems, the PSF must be computed from calibration imagery. The associated inverse problem is large-scale, so, in order to compute meaningful uncertainties with the reconstruction, it is common to use hierarchical Bayesian models and Markov chain Monte Carlo methods for sampling from the posterior. Classical Gibbs samplers can suffer from long autocorrelation lengths in the Markov chain when the reconstructed quantity in the inverse problem is finely discretized, resulting in poor computational efficiency of the Markov chain. In this work we present partially collapsed Gibbs samplers for linear inverse problems that greatly decrease correlations in the Markov chain, thus increasing the computational efficiency of the algorithms, and we present the results of the enhanced samplers on the problem of reconstructing the point spread function for an X-ray imaging system at the U.S. Department of Energy's Nevada National Security Site.

97 MATHEMATICS AND COMPUTING↗

Reconstruction from Uniformly Attenuated SPECT Projection Data Using the DBH Method

An algorithm was developed for the two-dimensional (2D) reconstruction of truncated and non-truncated uniformly attenuated data acquired from single photon emission computed tomography (SPECT). The algorithm is able to reconstruct data from half-scan (180o) and short-scan (180?+fan angle) acquisitions for parallel- and fan-beam geometries, respectively, as well as data from full-scan (360o) acquisitions. The algorithm is a derivative, backprojection, and Hilbert transform (DBH) method, which involves the backprojection of differentiated projection data followed by an inversion of the finite weighted Hilbert transform. The kernel of the inverse weighted Hilbert transform is solved numerically using matrix inversion. Numerical simulations confirm that the DBH method provides accurate reconstructions from half-scan and short-scan data, even when there is truncation. However, as the attenuation increases, finer data sampling is required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correction for patient table-induced scattered radiation in cone-beam computed tomography (CBCT)

Purpose: In image-guided radiotherapy, an artifact typically seen in axial slices of x-ray cone-beam computed tomography (CBCT) reconstructions is a dark region or ''black hole'' situated below the scan isocenter. The authors trace the cause of the artifact to scattered radiation produced by radiotherapy patient tabletops and show it is linked to the use of the offset-detector acquisition mode to enlarge the imaging field-of-view. The authors present a hybrid scatter kernel superposition (SKS) algorithm to correct for scatter from both the object-of-interest and the tabletop. Methods: Monte Carlo simulations and phantom experiments were first performed to identify the source of the black hole artifact. For correction, a SKS algorithm was developed that uses separate kernels to estimate scatter from the patient tabletop and the object-of-interest. Each projection is divided into two regions, one defined by the shadow cast by the tabletop on the imager and one defined by the unshadowed region. The region not shadowed by the tabletop is processed using the recently developed fast adaptive scatter kernel superposition (fASKS) method which employs asymmetric kernels that best model scatter transport through bodylike objects. The shadowed region is convolved with a combination of slab-derived symmetric SKS kernels and asymmetric fASKS kernels. The composition of the hybrid kernels is projection-angle-dependent. To test the algorithm, pelvis phantom and in vivo data were acquired using a CBCT test stand, a Varian Acuity simulator, and a Varian On-Board Imager, all of which have similar geometries and components. Artifact intensities and Hounsfield unit (HU) accuracies in the reconstructions were assessed before and after the correction. Results: The hybrid kernel algorithm provided effective correction and produced substantially better scatter estimates than the symmetric SKS or asymmetric fASKS methods alone. HU nonuniformities in the reconstructed pelvis phantom were reduced from 220 to 50 HU (i.e., 22%-5%). In the in vivo scans, the black hole artifact was reduced by up to 147 HU, a 73% improvement, and anatomical details in the prostate and rectum areas were made considerably more visible. Conclusions: Radiotherapy tabletops, which are generally flatter and larger than those used for diagnostic CT, can produce significant scatter-related artifacts. The proposed hybrid SKS algorithm accurately estimates scatter from both the object-of-interest and the patient tabletop, and resulting image uniformities and HU accuracies are greatly improved.

60 APPLIED LIFE SCIENCES↗

Signal Processing in SBND with Calibrated and Validated Electronics and Field Responses

SBND is a liquid argon time projection chamber in Fermilab’s Short-Baseline Neutrino Program, located 110 m from the neutrino source and operating in a high-rate environment with unprecedented statistics. Charged particles from neutrino interactions ionize the argon, and the resulting electrons drift to the anode wires, inducing current signals recorded as raw waveforms. These waveforms are a convolution of deposited charge with the electronics and TPC field responses, making accurate signal processing essential for recovering the true charge distribution. Signal processing forms the starting point for SBND reconstruction, directly impacting hit finding, charge calibration, clustering, and the reconstruction of tracks and showers, and therefore playing a key role in energy reconstruction and particle identification. In this poster, we present an overview of the SBND signal processing chain, including noise removal, channel-by-channel electronics correction, signal identification, and deconvolution using measured electronics and TPC field responses. We demonstrate that the two kernel functions—electronics and field responses—achieve high precision when compared to data, ensuring that the SBND signal processing chain provides a robust and accurate foundation for event reconstruction and precision physics measurements.

Singh, Prabhjot [Louisiana State U.] (ORCID:000000↗

Dictionary Learning with Accumulator Neurons

The Locally Competitive Algorithm (LCA) uses local competition between non-spiking leaky integrator neurons to infer sparse representations, allowing for potentially real-time execution on massively parallel neuromorphic architectures such as Intel's Loihi processor. Here, we focus on the problem of inferring sparse representations from streaming video using dictionaries of spatiotemporal features optimized in an unsupervised manner for sparse reconstruction. Non-spiking LCA has previously been used to achieve unsupervised learning of spatiotemporal dictionaries composed of convolutional kernels from raw, unlabeled video. We demonstrate how unsupervised dictionary learning with spiking LCA (\hbox{S-LCA}) can be efficiently implemented using accumulator neurons, which combine a conventional leaky-integrate-and-fire (\hbox{LIF}) spike generator with an additional state variable that is used to minimize the difference between the integrated input and the spiking output. We demonstrate dictionary learning across a wide range of dynamical regimes, from graded to intermittent spiking, for inferring sparse representations of both static images drawn from the CIFAR database as well as video frames captured from a DVS camera. On a classification task that requires identification of the suite from a deck of cards being rapidly flipped through as viewed by a DVS camera, we find essentially no degradation in performance as the LCA model used to infer sparse spatiotemporal representations migrates from graded to spiking. We conclude that accumulator neurons are likely to provide a powerful enabling component of future neuromorphic hardware for implementing online unsupervised learning of spatiotemporal dictionaries optimized for sparse reconstruction of streaming video from event based DVS cameras.

artificial intelligence↗

Kernel Manifolds: Nonlinear‐Augmentation Dimensionality Reduction Using Reproducing Kernel Hilbert Spaces

This paper generalizes recent advances on quadratic manifold (QM) dimensionality reduction by developing kernel methods-based nonlinear-augmentation dimensionality reduction. QMs, and more generally feature map-based nonlinear corrections, augment linear dimensionality reduction with a nonlinear correction term in the reconstruction map to overcome approximation accuracy limitations of purely linear approaches. While feature map-based approaches typically learn a least squares optimal polynomial correction term, we generalize this approach by learning an optimal nonlinear correction from a user-defined reproducing kernel Hilbert space. Our approach allows one to impose arbitrary nonlinear structure on the correction term, including polynomial structure, and includes feature map and radial basis function-based corrections as special cases. Furthermore, our method has relatively low training cost and has monotonically decreasing error as the latent space dimension increases. In conclusion, we compare our approach to proper orthogonal decomposition and several recent QM approaches on data from several example problems.

kernel methods↗

TwoFold: Highly accurate structure and affinity prediction for protein-ligand complexes from sequences

We describe our development of ab initio protein-ligand binding pose prediction models based on transformers and binding affinity prediction models based on the neural tangent kernel (NTK). Folding both protein and ligand, the TwoFold models achieve efficient and quality predictions matching state-of-the-art implementations while additionally reconstructing protein structures. In conclusion, solving NTK models points to a new use case for highly optimized linear solver benchmarking codes on HPC.

60 APPLIED LIFE SCIENCES↗

SU-C-BRD-07: Three-Dimensional Dose Reconstruction in the Presence of Inhomogeneities Using Fast EPID-Based Back-Projection Method

Purpose: Three-dimensional dose verification can detect errors introduced by the treatment planning system (TPS) or differences between planned and delivered dose distribution during the treatment. The aim of the study is to extend a previous in-house developed three-dimensional dose reconstructed model in homogeneous phantom to situtions in which tissue inhomogeneities are present. Methods: The method was based on the portal grey images from an electronic portal imaging device (EPID) and the relationship between beamlets and grey-scoring voxels at the position of the EPID. The relationship was expressed in the form of grey response matrix that was quantified using thickness-dependence scatter kernels determined by series of experiments. From the portal grey-value distribution information measured by the EPID the two-dimensional incident fluence distribution was reconstructed based on the grey response matrix using a fast iterative algorithm. The accuracy of this approach was verified using a four-field intensity-modulated radiotherapy (IMRT) plan for the treatment of lung cancer in anthopomorphic phantom. Each field had between twenty and twenty-eight segments and was evaluated by comparing the reconstructed dose distribution with the measured dose. Results: The gamma-evaluation method was used with various evaluation criteria of dose difference and distance-to-agreement: 3%/3mm and 2%/2 mm. The dose comparison for all irradiated fields showed a pass rate of 100% with the criterion of 3%/3mm, and a pass rate of higher than 92% with the criterion of 2%/2mm. Conclusion: Our experimental results demonstrate that our method is capable of accurately reconstructing three-dimensional dose distribution in the presence of inhomogeneities. Using the method, the combined planning and treatment delivery process is verified, offing an easy-to-use tool for the verification of complex treatments.

60 APPLIED LIFE SCIENCES↗

Quantitative Monte Carlo-based holmium-166 SPECT reconstruction

Purpose: Quantitative imaging of the radionuclide distribution is of increasing interest for microsphere radioembolization (RE) of liver malignancies, to aid treatment planning and dosimetry. For this purpose, holmium-166 ({sup 166}Ho) microspheres have been developed, which can be visualized with a gamma camera. The objective of this work is to develop and evaluate a new reconstruction method for quantitative {sup 166}Ho SPECT, including Monte Carlo-based modeling of photon contributions from the full energy spectrum.Methods: A fast Monte Carlo (MC) simulator was developed for simulation of {sup 166}Ho projection images and incorporated in a statistical reconstruction algorithm (SPECT-fMC). Photon scatter and attenuation for all photons sampled from the full {sup 166}Ho energy spectrum were modeled during reconstruction by Monte Carlo simulations. The energy- and distance-dependent collimator-detector response was modeled using precalculated convolution kernels. Phantom experiments were performed to quantitatively evaluate image contrast, image noise, count errors, and activity recovery coefficients (ARCs) of SPECT-fMC in comparison with those of an energy window-based method for correction of down-scattered high-energy photons (SPECT-DSW) and a previously presented hybrid method that combines MC simulation of photopeak scatter with energy window-based estimation of down-scattered high-energy contributions (SPECT-ppMC+DSW). Additionally, the impact of SPECT-fMC on whole-body recovered activities (A{sup est}) and estimated radiation absorbed doses was evaluated using clinical SPECT data of six {sup 166}Ho RE patients.Results: At the same noise level, SPECT-fMC images showed substantially higher contrast than SPECT-DSW and SPECT-ppMC+DSW in spheres ≥17 mm in diameter. The count error was reduced from 29% (SPECT-DSW) and 25% (SPECT-ppMC+DSW) to 12% (SPECT-fMC). ARCs in five spherical volumes of 1.96–106.21 ml were improved from 32%–63% (SPECT-DSW) and 50%–80% (SPECT-ppMC+DSW) to 76%–103% (SPECT-fMC). Furthermore, SPECT-fMC recovered whole-body activities were most accurate (A{sup est}= 1.06 × A − 5.90 MBq, R{sup 2}= 0.97) and SPECT-fMC tumor absorbed doses were significantly higher than with SPECT-DSW (p = 0.031) and SPECT-ppMC+DSW (p = 0.031).Conclusions: The quantitative accuracy of {sup 166}Ho SPECT is improved by Monte Carlo-based modeling of the image degrading factors. Consequently, the proposed reconstruction method enables accurate estimation of the radiation absorbed dose in clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sharp front tracking with geometric interface reconstruction

Here, this paper presents a novel sharp front-tracking method designed to address limitations in classical front-tracking approaches, specifically their reliance on smooth interpolation kernels and extended stencils for coupling the front and fluid mesh. In contrast, the proposed method employs exclusively sharp, localized interpolation and spreading kernels, restricting the coupling to the interfacial fluid cells–those containing the interface/front. This localized coupling is achieved by integrating a divergence-preserving velocity interpolation method with a piecewise parabolic interface calculation (PPIC) and a polyhedron intersection algorithm to compute the indicator function and local interface curvature. Surface tension is computed using the Continuum Surface Force (CSF) method, maintaining consistency with the sharp representation. Additionally, we propose an efficient local roughness smoothing implementation to account for surface mesh undulations, which is easily applicable to any triangulated surface mesh. Building on our previous work, the primary innovation of this study lies in the localization of the coupling for both the indicator function and surface tension calculations. By reducing the interface thickness on the fluid mesh to a single cell, as opposed to the 4–5 cell spans typical in classical methods, the proposed sharp front-tracking method achieves a highly localized and accurate representation of the interface. This sharper representation mitigates parasitic currents and improves force balancing, making it particularly suitable for scenarios where the interface plays a critical role, such as microfluidics, fluid-fluid interactions, and fluid-structure interactions. The proposed method is comprehensively validated and tested on canonical interfacial flow problems, including stationary and translating Laplace equilibria, oscillating droplets, and rising bubbles. The presented results demonstrate that the sharp front-tracking method significantly outperforms the classical approach in terms of accuracy, stability, and computational efficiency. Notably, parasitic currents are reduced by approximately two orders of magnitude and stable results are obtained for parameter ranges where classical front tracking fails to converge.

42 ENGINEERING↗

Gaussian processes for inferring parton distributions

The extraction of parton distribution functions (PDFs) from experimental or lattice QCD data is an ill-posed inverse problem, where regularization strongly impacts both systematic uncertainties and the reliability of the results. We study a framework based on Gaussian Process Regression (GPR) to reconstruct PDFs from lattice QCD matrix elements. Within a Bayesian framework, Gaussian processes serve as flexible priors that encode uncertainties, correlations, and constraints without imposing rigid functional forms. We investigate a wide range of kernel choices, mean functions, and hyperparameter treatments. We quantify information gained from the data using the Kullback-Leibler divergence. Synthetic data tests demonstrate the consistency and robustness of the method. Our study establishes GPR as a systematic and non-parametric approach to PDF reconstruction, offering controlled uncertainty estimates and reduced model bias in lattice QCD analyses.

hadronic spectroscopy↗

Portable HCAL reconstruction in the CMS detector using the Alpaka library

CMS has deployed a number of different GPU algorithms at the High-Level Trigger (HLT) in Run 3. As the code base for GPU algorithms continues to grow, the burden for developing and maintaining separate implementations for GPU and CPU becomes increasingly challenging. To mitigate this, CMS has adopted the Alpaka (Abstraction Library for Parallel Kernel Acceleration) library as the performance portability solution to provide a single-code base for parallel execution on both GPUs and CPUs in CMS software (CMSSW). A direct CUDA version of HCAL energy reconstruction, called Minimization At Hcal, Iteratively (MAHI), has been deployed at the HLT in the 2022-2023 data taking period. This contribution will describe how the CUDA version is converted into a portable implementation using the Alpaka library. We will discuss the porting experience from CUDA to Alpaka, the validation process and the performance of the Alpaka version in CPU and GPU.

Kwok, Martin↗

Sparse Matrix-Based HPC Tomography

Tomographic imaging has benefited from advances in X-ray sources, detectors and optics to enable novel observations in science, engineering and medicine. These advances have come with a dramatic increase of input data in the form of faster frame rates, larger fields of view or higher resolution, so high performance solutions are currently widely used for analysis. Tomographic instruments can vary significantly from one to another, including the hardware employed for reconstruction: from single CPU workstations to large scale hybrid CPU/GPU supercomputers. Furthermore, flexibility on the software interfaces and reconstruction engines are also highly valued to allow for easy development and prototyping. This paper presents a novel software framework for tomographic analysis that tackles all aforementioned requirements. The proposed solution capitalizes on the increased performance of sparse matrix-vector multiplication and exploits multi-CPU and GPU reconstruction over MPI. Furthermore, the solution is implemented in Python and relies on CuPy for fast GPU operators and CUDA kernel integration, and on SciPy for CPU sparse matrix computation. As opposed to previous tomography solutions that are tailor-made for specific use cases or hardware, the proposed software is designed to provide flexible, portable and high-performance operators that can be used for continuous integration at different production environments, but also for prototyping new experimental settings or for algorithmic development. The experimental results demonstrate how our implementation can even outperform state-of-the-art software packages used at advanced X-ray sources worldwide.

97 MATHEMATICS AND COMPUTING↗

Relaxing Direct Ptychography Sampling Requirements via Parallax Imaging Insights

Direct ptychography enables the retrieval of information encoded in the phase of an electron wave passing through a thin sample by deconvolving the interference effects of a converged probe with known aberrations. Under the weak phase object approximation, this permits the optimal transfer of information using noniterative techniques. However, the achievable resolution of the technique is traditionally limited by the probe step size—setting stringent Nyquist sampling requirements. At the same time, parallax imaging has emerged as a dose-efficient phase technique which relaxes sampling requirements and enables scan-upsampling. Here, we formulate parallax imaging as a quadratic approximation to part of the direct ptychography kernel and use this insight to enable upsampling in direct ptychography. We validate our analytical results numerically using simulated and experimental reconstructions.

direct ptychography, parallax imaging, scan Nyquis↗