Search NASA⌕ Search

SEARCH · Search NASA

Results for “low temperature detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

FET's Perform Well At Cryogenic Temperatures

New metal-oxide-semiconductor field-effect transistors designed for source-follower preamplifiers operating at liquid-helium temperatures in conjunction with infrared detectors. Lower thresholds and offset give CryoFET's greater dynamic range and linearity than conventional MOSFET's at low temperatures and facilitates pair balancing to reduce offsets in output. Reduces heat loading of cryogenic system, extending life, reliability, and performance of cryogenic infrared instruments.

Sclar, N.↗

High field CdS detector for infrared radiation

New and highly sensitive method of detecting infrared irradiation makes possible solid state infrared detector which is more sensitive near room temperature than usual photoconductive low band gap semiconductor devices. Reconfiguration of high field domains in cadmium sulphide crystals provides basis for discovery.

Tyagi, R. C.↗

Thin-Film Air-Mass-Flow Sensor of Improved Design Developed

Researchers at the NASA Glenn Research Center have developed a new air-mass-flow sensor to solve the problems of existing mass flow sensor designs. NASA's design consists of thin-film resistors in a Wheatstone bridge arrangement. The resistors are fabricated on a thin, constant-thickness airfoil to minimize disturbance to the airflow being measured. The following photograph shows one of NASA s prototype sensors. In comparison to other air-mass-flow sensor designs, NASA s thin-film sensor is much more robust than hot wires, causes less airflow disturbance than pitot tubes, is more accurate than vane anemometers, and is much simpler to operate than thermocouple rakes. NASA s thin-film air-mass-flow sensor works by converting the temperature difference seen at each leg of the thin-film Wheatstone bridge into a mass-flow rate. The following figure shows a schematic of this sensor with air flowing around it. The sensor operates as follows: current is applied to the bridge, which increases its temperature. If there is no flow, all the arms are heated equally, the bridge remains in balance, and there is no signal. If there is flow, the air passing over the upstream legs of the bridge reduces the temperature of the upstream legs and that leads to reduced electrical resistance for those legs. After the air has picked up heat from the upstream legs, it continues and passes over the downstream legs of the bridge. The heated air raises the temperature of these legs, increasing their electrical resistance. The resistance difference between the upstream and downstream legs unbalances the bridge, causing a voltage difference that can be amplified and calibrated to the airflow rate. Separate sensors mounted on the airfoil measure the temperature of the airflow, which is used to complete the calculation for the mass of air passing by the sensor. A current application for air-mass-flow sensors is as part of the intake system for an internal combustion engine. A mass-flow sensor is used to provide accurate information about the amount of air entering the engine so that the amount of fuel can be adjusted to give the most efficient combustion. The ideal mass-flow sensor would be a rugged design that minimizes the disturbance to the flow stream and provides an accurate reading of both smooth and turbulent flows; NASA's design satisfies these requirements better than any existing design. Most of the mass-flow sensors used today are the hot wire variety. Hot wires can be fragile and cannot accurately measure a turbulent or reversing flow, which is often encountered in an intake manifold. Other types of mass-flow sensors include pitot tubes, vane anemometers, and thermocouple rakes-all of which suffer from some type of performance problem. Because it solves these performance problems while maintaining a simple design that lends itself to low-cost manufacturing techniques, NASA s thin-film resistance temperature detector air-mass-flow sensor should lead to more widespread use of mass-flow sensors.

Fralick, Gustave C.↗

Compact Midwave Imaging System: Results from an Airborne Demonstration

The Compact Midwave Imaging System (CMIS) is a wide field of view, multi-angle, multi-spectral push frame imager that relies on the forward motion of the satellite to create a two-dimensional (2D) image swath. An airborne demonstration of CMIS was successfully completed in January-February 2021 on the NASA Langley Research Center Gulfstream III. The primary objective of the four-flight campaign was to demonstrate the capability of this unique instrument to perform stereo observations of clouds and other particulates (e.g. smoke) in the atmosphere. It is shown that the midwave infrared (MWIR) spectral bands of CMIS provide a unique 24/7 capability with high resolution for accurate stereo sensing.The instrument relies on new focal plane array (FPA) technology, which provides excellent sensitivity at much warmer detector temperatures than traditional technologies. This capability enabled a compact, low-cost design that can provide atmospheric motion vectors and cloud heights to support requirements for atmospheric winds in the 2017-2027 Earth Science Decadal Survey. Applications include day/night observations of the planetary boundary layer, severe weather, and wildfires. A comparison with current space-based earth science instruments demonstrates that the SWIR/MWIR multi-spectral capability of CMIS is competitive with larger, more expensive instrumentation. Imagery obtained over a controlled burn and operating nuclear power plant demonstrated the sensitivity of the instrument to temperature variations. The system relies on a mature stereoscopic imaging technique applied to the same scene from two independent platforms to unambiguously retrieve atmospheric motion vectors (AMVs) with accurate height assignment.This capability has been successfully applied to geostationary and low-earth orbit satellites to achieve excellent accuracy. When applied to a ground-point validation case, the accuracy for the CMIS aircraft observations was 20 m and 0.3 m/s for cloud heights and motion vectors, respectively. This result was confirmed by a detailed error analysis with analytical and covariance models. The results for CMIS cases with under flights of Aeolus, CALIPSO and Aqua provided a good validation of expected accuracies. The paper also showed the feasibility of accommodating CMIS on CubeSats to enable multiple instruments to be flown in a leader-follower mode.

stereo winds↗

Detector Assembly and the Ultralow-Temperature Refrigerator for XRS

The X-ray spectrometer (XRS) on the Japanese Astro-E Spacecraft is the first ultra low temperature space borne instrument. The system utilizes a 900g Ferric Ammonium Alum (FAA) Adiabatic Demagnetization Refrigerator (ADR) with a helium-3 gas gap heat switch to cool the detector assembly to 0.060K. The system operates in a "single shot" configuration allowing the system to remain at its operating temperature for about 40 hours in the lab. The on-orbit performance is expected to be about 35 hours with a 97% duty cycle. The detector assembly for XRS consists of a 32 channel microcalorimeter array bias electronics, thermometry, and an anti-coincidence detector that are attached to the cold stage of the ADR. To thermally Isolate the detector system from the superfluid helium reservoir, the detector system is suspended by Kevlar cords and electrical connection in made by L30, 17-micron diameter, tensioned NbTi leads. The detectors are read out in a source-follower arrangement using FET amplifiers operating at 130K mounted in multiply-thermally-isolated assemblies that also use Kevlar and stainless steel wiring. The design and thermal performance of this system will be discussed and compared to the theoretical limits.

Porter, F. S.↗

Spaceflight performance of silver coated FEP Teflon as a thermal control surface on the IMP-1 spacecraft

A second surface mirror type coating, vapor deposited silver on FEP Teflon, was used as a thermal control surface for one of the experiments aboard the Imp-I spacecraft. This coating was selected to obtain the low operating temperature required for this experiment. Initial flight temperature of this thermal control surface was -70.5 C, very close to the predicted value of -73 C and at a very satisfactory level. Since temperatures within the spacecraft interior are not at this desired low level, the detectors had to be mounted exterior to the spacecraft with a good view of space, preferably in an area shaded from sunlight. When this latter preference proved unobtainable, the detectors were mounted on an aluminum plate located on the exterior of the spacecraft, parallel to the spin axis but rotating about the solar vector. The mounting plate was approximately 6.5 inches by 7.5 inches by 0.125 inches thick. To achieve the desired temperature level with the mounting plate in such a location, the thermal design had to minimize not only the effects of the relatively warm spacecraft environment but also the effects of the incident solar energy.

Hoffman, R. H.↗

The Dielectric Bolometer, A New Type of Thermal Radiation Detector

Thermal detectors for the infrared, such as thermocouples and bolometers, are limited in their ultimate sensitivity predominantly by Johnson noise rather than temperature noise. Low noise figures are hard to achieve since Johnson noise preponderates temperature noise, which is the only essential noise for thermal detectors. The dielectric constants of some materials are sufficiently temperature dependent to make a new type of bolometer feasible. The basic theory of a dielectric bolometer, as shown here, promises noise figures below 3 decibels even at chopper frequencies well above the 1/tau value of the detector. Ferroelectrics such as barium-strontium titanate and others seem to be well suited for radiation-cooled dielectric bolometers.

Hanel, R. A.↗

Vapor Growth of Indium Monoiodide

Indium (I) iodide, InI, is part of a group of heavy metal iodides that can be used as room temperature radiation detectors. Other examples are HgI2, PbI2, BiI3, or TlPbI3. InI has several advantages, such as low toxicity, no solid phase transition (such as in HgI2), and no tendency to form polytypes (PbI2, BiI3 ). All binary iodides have layered structures and are quite soft, but InI is also the mechanically most stable compound of the binary compounds. Table 1 shows the main properties of InI in comparison with the other iodides and the most common room temperature radiation detector material, (Cd, Zn)Te. InI is typically grown by the unseeded Bridgman method using a nucleation tip, but Czochralski (CZ) growth has also been demonstrated. The resulting crystals have been used successfully for radiation detection, but both resistivity and mobility are usually well below theoretically predicted values. Physical vapor transport (PVT), although much slower than melt growth, is an alternative method and has been used to grow e.g. HgI2, PbI2, BiI3, CdTe. PVT growth should eliminate or reduce inclusions and impurities since it is based on sublimation, reduce intrinsic defects due to the lower growth temperature, and reduce dislocation densities due to reduced thermal and mechanical stress. As an example, PVT-grown CdTe showed a much improved structural quality compared to Bridgman- or THM-grown material.

Cröll, Arne↗

Sensor requirements for Earth and planetary observations

Future generations of Earth and planetary remote sensing instruments will require extensive developments of new long-wave and very long-wave infrared detectors. The upcoming NASA Earth Observing System (EOS) will carry a suite of instruments to monitor a wide range of atmospheric and surface parameters with an unprecedented degree of accuracy for a period of 10 to 15 years. These instruments will observe Earth over a wide spectral range extending from the visible to nearly 17 micrometers with a moderate to high spectral and spacial resolution. In addition to expected improvements in communication bandwidth and both ground and on-board computing power, these new sensor systems will need large two-dimensional detector arrays. Such arrays exist for visible wavelengths and, to a lesser extent, for short wavelength infrared systems. The most dramatic need is for new Long Wavelength Infrared (LWIR) and Very Long Wavelength Infrared (VLWIR) detector technologies that are compatible with area array readout devices and can operate in the temperature range supported by long life, low power refrigerators. A scientific need for radiometric and calibration accuracies approaching 1 percent translates into a requirement for detectors with excellent linearity, stability and insensitivity to operating conditions and space radiation. Current examples of the kind of scientific missions these new thermal IR detectors would enhance in the future include instruments for Earth science such as Orbital Volcanological Observations (OVO), Atmospheric Infrared Sounder (AIRS), Moderate Resolution Imaging Spectrometer (MODIS), and Spectroscopy in the Atmosphere using Far Infrared Emission (SAFIRE). Planetary exploration missions such as Cassini also provide examples of instrument concepts that could be enhanced by new IR detector technologies.

Chahine, Moustafa T.↗

Chamber For Testing Infrared Imaging Detectors

Chamber provides cold, vacuum, low-background-radiation environment and optical and electrical feedthroughs needed for testing and calibration of planar arrays of long-wavelength infrared photodetectors. Equipped with multiple ports for vacuum pumps, vacuum gauges, cryogenic fluids, sources of radiation, and camera heads. Accommodates variety of infrared sources, detectors, and associated equipment for testing at temperatures down to about 4.2 K in low-background-radiation environment.

Staller, Craig O.↗

From the Cluster Temperature Function to the Mass Function at Low Z

This XMM project consisted of three observations of the nearby, hot galaxy cluster Triangulum Australis, one of the cluster center and two offsets. The goal was to measure the radial gas temperature profile out to large radii and derive the total gravitating mass within the radius of average mass overdensity 500. The central pointing also provides data for a detailed two-dimensional gas temperature map of this interesting cluster. We have analyzed all three observations. The derivation of the temperature map using the central pointing is complete, and the paper is soon to be submitted. During the course of this study and of the analysis of archival XMM cluster observations, it became apparent that the commonly used XMM background flare screening techniques are often not accurate enough for studies of the cluster outer regions. The information on the cluster's total masses is contained at large off-center distances, and it is precisely the temperatures for those low-brightness regions that are most affected by the detector background anomalies. In particular, our two offset observations of the Triangulum have been contaminated by the background flares ("bad cosmic weather") to a degree where they could not be used for accurate spectral analysis. This forced us to expand the scope of our project. We needed to devise a more accurate method of screening and modeling the background flares, and to evaluate the uncertainty of the XMM background modeling. To do this, we have analyzed a large number of archival EPIC blank-field and closed-cover observations. As a result, we have derived stricter background screening criteria. It also turned out that mild flares affecting EPIC-pn can be modeled with an adequate accuracy. Such modeling has been used to derive our Triangulum temperature map. The results of our XMM background analysis, including the modeling recipes, are presented in a paper which is in final preparation and will be submitted soon. It will be useful not only for our future analysis but for other XMM cluster observations as well.

Mushotzky, Richard↗

Advanced Components for Spaceborne Infrared Astronomy

Basic improvements in the technology of low noise read-out systems for low background detectors were demonstrated. Using discrete JFET integrating amplifiers at their optimum temperature of 55 K, read noise less than 7.5 electrons in 128 seconds of integration was obtained. Two models of single channel integrators are now available, the JF-77 for use between 50 and 80 K and the JF-4 for lower temperatures. A 1 x 15 linear array of complete integrators on a single integrated circuit was developed and will be made available in the near future. The successful operation of a superconducting stepper motor was demonstrated. The motor shows a three fold increase in torque over conventional motors operating at room temperature. The success of the motor stems from the use of superconducting coils in conjunction with developments in bearings for cryogenic use, rare-earth rotors, and motor cooling techniques. The current state of development will allow the rapid development of motors optimized for specific applications. An electronic switch capable of resetting cooled JFET integrating amplifiers was developed. The JFET integrating amplifiers that use this switch have demonstrated read noise of less than 10 electrons. The JFET reset device exhibits an extremely high open impedance and low leakage current. Capacitance is sufficiently low so as not to impair amplifier sensitivity. The effects of transient switching charges are minimized by a compensation technique and variable transient current problems inherent to devices of this type are overcome by external circuity.

Davidson, Arnold W.↗

Dust environment of Comet Halley

Advances in the understanding of comet Halley's dust environment are highlighted. Spacecraft results on the dust composition, the detection of subfemtogram grains, and the particle-mass distribution; jets and the dust-emission pattern; the existence of discrete sources on the nucleus surface and the determination of their locations from day-to-day motions of coma features; CN jets; large-scale phenomena, including an antitail, streamers, and a sunward spike; infrared observations, such as the 3.4 microns emission feature, applications of array detectors, and rare far-infrared data; the chemical modification of low-temperature ices by UV and cosmic-ray irradiation processes, their laboratory simulations, and applications to the evolution of comets; the interstellar-connection models of comet origin; and the formation of a mantle made of refractory organic material on the nucleus surface.

Sekanina, Z.↗

Studies of thermal wave phenomena on the Jovian planets

Ground based and Voyager observations of Jupiter have provided evidence that the tropospheric temperature shows global scale longitudinal variations which are often wavelike in character. Voyager data are reported to exhibit the presence of slowly moving thermal features, wherein the jovian tropospheric temperature patterns are not advected by the equatorial zonal winds, but are not found to rotate at the System III (interior) rate. Ground based data in a broad infrared band (8 to 13 micron) show a wavelike structure whose amplitude and spatial scale are similar to the reported properties of the slowly moving thermal features. This study is directed toward obtaining additional ground based data in infrared spectral bands whose contribution functions are optimized for specific atmospheric regions (tropospheric at 20 micron, and stratospheric at 7.8 micron), in order to confirm the previous results, and to identify the nature and physical significance of wavelike longitudinal temperature fluctuations on the Jovian planets. A 2-D infrared array detector and low resolution cryogenic grating spectrometer is being adapted to obtain maps in approx. 2/cm bandpasses.

Deming, Drake↗

NASA Tech Briefs, December 2009

Topics include: A Deep Space Network Portable Radio Science Receiver; Detecting Phase Boundaries in Hard-Sphere Suspensions; Low-Complexity Lossless and Near-Lossless Data Compression Technique for Multispectral Imagery; Very-Long-Distance Remote Hearing and Vibrometry; Using GPS to Detect Imminent Tsunamis; Stream Flow Prediction by Remote Sensing and Genetic Programming; Pilotless Frame Synchronization Using LDPC Code Constraints; Radiometer on a Chip; Measuring Luminescence Lifetime With Help of a DSP; Modulation Based on Probability Density Functions; Ku Telemetry Modulator for Suborbital Vehicles; Photonic Links for High-Performance Arraying of Antennas; Reconfigurable, Bi-Directional Flexfet Level Shifter for Low-Power, Rad-Hard Integration; Hardware-Efficient Monitoring of I/O Signals; Video System for Viewing From a Remote or Windowless Cockpit; Spacesuit Data Display and Management System; IEEE 1394 Hub With Fault Containment; Compact, Miniature MMIC Receiver Modules for an MMIC Array Spectrograph; Waveguide Transition for Submillimeter-Wave MMICs; Magnetic-Field-Tunable Superconducting Rectifier; Bonded Invar Clip Removal Using Foil Heaters; Fabricating Radial Groove Gratings Using Projection Photolithography; Gratings Fabricated on Flat Surfaces and Reproduced on Non-Flat Substrates; Method for Measuring the Volume-Scattering Function of Water; Method of Heating a Foam-Based Catalyst Bed; Small Deflection Energy Analyzer for Energy and Angular Distributions; Polymeric Bladder for Storing Liquid Oxygen; Pyrotechnic Simulator/Stray-Voltage Detector; Inventions Utilizing Microfluidics and Colloidal Particles; RuO2 Thermometer for Ultra-Low Temperatures; Ultra-Compact, High-Resolution LADAR System for 3D Imaging; Dual-Channel Multi-Purpose Telescope; Objective Lens Optimized for Wavefront Delivery, Pupil Imaging, and Pupil Ghosting; CMOS Camera Array With Onboard Memory; Quickly Approximating the Distance Between Two Objects; Processing Images of Craters for Spacecraft Navigation; Adaptive Morphological Feature-Based Object Classifier for a Color Imaging System; Rover Slip Validation and Prediction Algorithm; Safety and Quality Training Simulator; Supply-Chain Optimization Template; Algorithm for Computing Particle/Surface Interactions; Cryogenic Pupil Alignment Test Architecture for Aberrated Pupil Images; and Thermal Transport Model for Heat Sink Design.

Source record↗

Thermal Vacuum/Balance Test Results of Swift BAT with Loop Heat Pipe Thermal System

The Swift Burst Alert Telescope (BAT) Detector Array is thermally well coupled to eight constant conductance heat pipes (CCHPs) embedded in the Detector Array Plate PAP), and two loop heat pipes (LHPs) transport heat from the CCHPs to a radiator. The CCHPs have ammonia as the working fluid and the LHPs have propylene as the working fluid. Precision heater controllers, which have adjustable set points in flight, are used to control the LHP compensation chamber and Detector Array xA1 ASIC temperatures. The radiator has AZ-Tek's AZW-LA-II low solar absorptance white paint as the thermal coating, and is located on the anti-sun side of the spacecraft. A thermal balance (T/B) test on the BAT was successfully completed. It validated that the thermal design satisfies the temperature requirements of the BAT in the flight thermal environments. Instrument level and observatory level thermal vacuum (TN) cycling tests of the BAT Detector Array by using the LHP thermal system were successfully completed. This paper presents the results of the T/B test and T N cycling tests.

Choi, Michael K.↗

SiC Charged Particle Telescope GRC Independent Research and Development (IRAD) Program End of Project Final Report

In an advancement over the state-of-the art, NASA Glenn Research Center (GRC) has developed a large area silicon carbide (SiC)-based charged particle telescope through an Independent Research and Development (IRAD) project. The telescope has been demonstrated to have improved noise characteristics and resolution than previous SiC detectors. This improvement will meet the challenges of compact multidirectional robust radiation detector systems to study a wide range of elementary particle mass and energies. In order to provide a complete understanding of how energetic processes internal and external to the solar system shape magnetospheres, atmospheres, and surfaces, in situ particle observations should include measurements of Solar Energetic Particles (SEP) and Galactic Cosmic Rays (GCR), along with solar wind and plasma. The potential temperature stability, tolerance to high radiation environments, and low noise characteristics expected in SiC-based detectors can have advantages over the state-of-the-art silicon detectors. These advantages will allow the detectors to be deployed in small compact systems on a variety of platforms, enabling compact structures for small satellite platforms with improved data quality.

Field and particle detectors↗

Review and Performance Testing of the Optical Power Monitor (PMON)

The LISA mission requires a high precision optical power monitoring and control system that combines high reliability and measurement accuracy with extremely low disturbance to the core interferometric detection system. NASA is working with Avo Photonics to design and build this optical power monitor, known as PMON. The high-level design requirements take into account detector redundancy, mechanical rigidity, stability against temperature and input alignment changes, parasitic scatter and reflection artifacts, as well as low magnetic field. Gamma and Proton radiation tests have been performed on the photodiodes from a few vendors to verify radiation tolerance. Engineering development units of the PMON have been fabricated, delivered and evaluated at NASA.

Hua Jiao↗