Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Uncertainty relation revisited from quantum estimation theory

We use quantum estimation theory to formulate bounds of errors in quantum measurement for arbitrary quantum states and observables in a finite-dimensional Hilbert space. We prove that the measurement errors of two noncommuting observables satisfy Heisenberg-type uncertainty relation, find the achievable bound, and propose a strategy to achieve it.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the application of the expected log-likelihood gain to decision making in molecular replacement

Molecular-replacement phasing of macromolecular crystal structures is often fast, but if a molecular-replacement solution is not immediately obtained the crystallographer must judge whether to pursue molecular replacement or to attempt experimental phasing as the quickest path to structure solution. The introduction of the expected log-likelihood gain has given the crystallographer a powerful new tool to aid in making this decision. The eLLG is the log-likelihood gain on intensity expected from a correctly placed model. It is calculated as a sum over the reflections of a function dependent on the fraction of the scattering for which the model accounts, the estimated model coordinate error and the measurement errors in the data. It is shown how the eLLG may be used to answer the question 'can I solve my structure by molecular replacement?'. However, this is only the most obvious of the applications of the eLLG. It is also discussed how the eLLG may be used to determine the search order and minimal data requirements for obtaining a molecular-replacement solution using a given model, and for decision making in fragment-based molecular replacement, single-atom molecular replacement and likelihood-guided model pruning.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of Distributive Consensus Algorithms for AnomalyDetection on the Power-Grid

As an increasing number of devices in the power-grid rely on high-precision clocks to measure electrical properties and time stamp data, GPS receivers have become a vulnerability on the power-grid. GPS spoofing attacks, in which a fake signal is transmitted, can cause sensor measurement errors that can misinform protective equipment and grid operators for both the transmission and distribution grid. The technology being developed to secure precision clocks in the transmission grid are not appropriate for the distribution grid. Thus, there is a need to developed anomaly detection algorithms that are suitable for the hardware available on the distribution grid. Traditionally, a distributed detection framework is comprised of spatially distributed nodes which acquire observations about a quantity of interest and sends the data to the fusion center, where a global decision is made. Instead the distribution grid has low-power devices, such as smart inverters and microPMUs, that could be used to perform highly parallelized calculations. Having on node calculations is beneficial since it is more network and computation efficient, as the more calculations can be performed where the data is being captured instead of communicating across a slow network to a centralized fusion center. Instead, we could employ an alternate peer-to-peer type of information exchange on the distribution grid that can still reach a global decision. A decentralized approach to anomaly detection makes efficient use of the computational and network bandwidth that exists, and it also lacks the single point of failure of a centralized approach. Thus, a decentralized local information exchange and/or inference is preferred. Lastly, the unreliability of the distribution grid network connections and potential noise or error in the measurements must be considered. In order to produce an effective detection tool, a Byzantine-fault tolerant and asynchronous algorithm must be developed. Thus, the first phase of our project is to develop a distributed, decentralized, asynchronous, Byzantine-fault tolerant, collaborative autonomy-based anomaly detection algorithm to collectively analyze clusters of data for signs of a malicious attack.

97 MATHEMATICS AND COMPUTING↗

Non-disruptive error field measurement in DIII-D low safety factor plasmas and projection to ITER

Previous experiments in DIII-D (Paz-Soldan et al 2022 Nucl. Fusion 62 126007) introduced a method to identify intrinsic error fields (EFs) in tokamaks with minimal disruption risk by promptly healing driven magnetic islands during the conventional 'compass scan'. This paper presents recent experimental and numerical advancements in extending this approach to low q 95 plasmas, and projects its applicability to ITER. Non-disruptive EF measurement is achieved at q 95 = 4.5 and 3.9 without any initial EF correction (EFC) by reducing the time between the occurrence of the locked mode (LM) and control action to 10 ms and increasing the density 50%–100%. However, 50% correction of the intrinsic EF is required to achieve island healing at q 95 = 3.2 with 10 ms delay for the control action. Nonlinear two-fluid modeling with the TM1 code reproduces the DIII-D experimental observations, indicating that promptly turning off the 3D coil current reduces both magnetic island width and electromagnetic force, while raising the density increases plasma viscosity, facilitating magnetic island healing. The simulations show that for scenarios with q 95 = 3.2, lowering the control action time to 5 ms will lead to island healing without EFC. TM1 simulations are extended to future ITER scenarios with 5 MA and 7.5 MA plasma currents, predicting the dependence of required density rise on action time and EF amplitude. These simulations indicate that, benefiting from the much longer resistive time, island healing can be successfully achieved in ITER when taking control action 100–500 ms after a LM occurrence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Error field measurements with rotating RMP fields for DIII-D H-mode

3D magnetic sensors are employed to identify the amplitude and toroidal phase of error fields (EF) by analyzing the torque balance for magnetic islands entrained by rotating resonant magnetic perturbations (RMPs) in DIII-D H-mode plasmas. This technique of torque balance allows for efficient error field identification, offering a valuable tool for scenario-specific and optimized error field compensation (EFC) and requires only magnetic diagnostics. The torque balance used in this work includes the contribution from electromagnetic torque due to error fields, wall response, RMP fields, and viscous. Results show that viscous torque plays a crucial role, particularly during locked modes and H-mode plasmas, ensuring accurate data fits with lower residuals. The torque balance technique reveals that the L- and H-mode plasmas have distinct EF configurations, and consistent with a model-based EF analysis including MHD response in IPEC and the SURFMN EF simulation. This technique shows great robustness in measuring the intrinsic EF amplitude regardless of its amplitude or toroidal phase. Repeated discharges with EFC disparities exhibit consistent results of intrinsic error field within a reasonable range near the “standard” error field compensation. Additionally, the use of a rotating n = 1 resonant magnetic perturbation offers the advantage of reducing disruption risks by entraining saturated magnetic islands. These findings are instrumental for optimizing EF correction in fusion devices, thereby enhancing tearing mode suppression and overall plasma stability.

3D magnetic sensors↗

LIDAR Wind Speed Measurements of Evolving Wind Fields

Light Detection and Ranging (LIDAR) systems are able to measure the speed of incoming wind before it interacts with a wind turbine rotor. These preview wind measurements can be used in feedforward control systems that are designed to reduce turbine loads. However, the degree to which such preview-based control techniques can reduce loads by reacting to turbulence depends on how accurately the incoming wind field can be measured. Past studies have assumed the validity of physicist G.I. Taylor's 1938 frozen turbulence hypothesis, which implies that turbulence remains unchanged as it advects downwind at the mean wind speed. With Taylor's hypothesis applied, the only source of wind speed measurement error is distortion caused by the LIDAR. This study introduces wind evolution, characterized by the longitudinal coherence of the wind, to LIDAR measurement simulations using the National Renewable Energy Laboratory's (NREL's) 5-megawatt turbine model to create a more realistic measurement model. A simple model of wind evolution was applied to a frozen wind field that was used in previous studies to investigate the effects of varying the intensity of wind evolution. LIDAR measurements were also evaluated using a large eddy simulation (LES) of a stable boundary layer that was provided by the National Center for Atmospheric Research. The LIDAR measurement scenario investigated consists of a hub-mounted LIDAR that scans a circle of points upwind of the turbine in order to estimate the wind speed component in the mean wind direction. Different combinations of the preview distance that is located upwind of the rotor and the radius of the scan circle were analyzed. It was found that the dominant source of measurement error for short preview distances is the detection of transverse and vertical wind speeds from the line-of-sight LIDAR measurement. It was discovered in previous studies that, in the absence of wind evolution, the dominant source of error for large preview distances is the spatial averaging caused by the LIDAR's sampling volume. However, by introducing wind evolution, the dominant source of error for large preview distances was found to be the coherence loss caused by evolving turbulence. Different measurement geometries were compared using the bandwidth for which the measurement coherence remained above 0.5 and also the area under the measurement coherence curve. Results showed that, by increasing the intensity of wind evolution, the measurement coherence decreases. Using the coherence bandwidth metric, the optimal preview distance for a fixed-scan radius remained almost constant for low and moderate amounts of wind evolution. For the wind field with the simple wind evolution model introduced, the optimal preview distance for a scan radius of 75% blade span (47.25 meters) was found to be 80 meters. Using the LES wind field, the optimal preview distance was 65 meters. When comparing scan geometries using the area under the coherence curve, results showed that, as the intensity of wind evolution increases, the optimal preview distance decreases.

17 WIND ENERGY↗

Breast Patient Setup Error Assessment: Comparison of Electronic Portal Image Devices and Cone-Beam Computed Tomography Matching Results

Purpose: To quantify the differences in setup errors measured with the cone-beam computed tomography (CBCT) and electronic portal image devices (EPID) in breast cancer patients. Methods and Materials: Repeat CBCT scan were acquired for routine offline setup verification in 20 breast cancer patients. During the CBCT imaging fractions, EPID images of the treatment beams were recorded. Registrations of the bony anatomy for CBCT to planning CT and EPID to digitally reconstructed-radiographs (DRRs) were compared. In addition, similar measurements of an anthropomorphic thorax phantom were acquired. Bland-Altman and linear regression analysis were performed for clinical and phantom registrations. Systematic and random setup errors were quantified for CBCT and EPID-driven correction protocols in the EPID coordinate system (U, V), with V parallel to the cranial-caudal axis and U perpendicular to V and the central beam axis. Results: Bland-Altman analysis of clinical EPID and CBCT registrations yielded 4 to 6-mm limits of agreement, indicating that both methods were not compatible. The EPID-based setup errors were smaller than the CBCT-based setup errors. Phantom measurements showed that CBCT accurately measures setup error whereas EPID underestimates setup errors in the cranial-caudal direction. In the clinical measurements, the residual bony anatomy setup errors after offline CBCT-based corrections were {Sigma}{sub U} = 1.4 mm, {Sigma}{sub V} = 1.7 mm, and {sigma}{sub U} = 2.6 mm, {sigma}{sub V} = 3.1 mm. Residual setup errors of EPID driven corrections corrected for underestimation were estimated at {Sigma}{sub U} = 2.2mm, {Sigma}{sub V} = 3.3 mm, and {sigma}{sub U} = 2.9 mm, {sigma}{sub V} = 2.9 mm. Conclusion: EPID registration underestimated the actual bony anatomy setup error in breast cancer patients by 20% to 50%. Using CBCT decreased setup uncertainties significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SRF Cavity Testing Using a FPGA Self Excited Loop

This document provides a detailed description of procedures for very-high precision calibration and testing of superconducting RF cavities using digital Low-Level RF (LLRF) electronics based on Field Programmable Gate Arrays (FPGA). The use of a Self-Excited Loop with an innovative procedure for fast turn-on allows the measurement of the forward, reflected and transmitted power from a single port of the directional coupler in front of the cavity, thus eliminating certain measurement errors. Various procedures for measuring the quality factor as a function of cavity fields are described, including a single RF pulse technique. Errors are estimated for the measurements.

43 PARTICLE ACCELERATORS↗

Open Source Fault-tolerant Grid Frequency Measurement for Solar Inverters

The Discrete Fourier transform (DFT) based measurement algorithms are one of the most common measurement algorithms for grid parameter estimation such as rms, phase angle, frequency. Over the past few years, many DFT based algorithms have been developed to enhance its measurement accuracy under steady-state and/or dynamic grid conditions. For example, an adaptive band-pass filter utilizing exponential modulation filter has been proposed to reduce measurement errors at the presence of large frequency deviations. Measurement accuracy of different algorithms including FIR filter, extended Kalman filtering (EKF), and enhanced DFT method have been compared in detail under different grid conditions. Two artificial signals that have 90-degree phase difference were constructed by the Clarke transformation to address the frequency spectrum leakage of DFT. A multi-module approach was developed to enhance both steady-state and dynamic measurement accuracies, in which each module was developed to eliminate some specific errors. Besides DFT-based measurement algorithms, some signal model-based algorithms have been developed to further improve the accuracy under dynamic conditions. However, a key drawback of the state-of-the-art algorithms is that they cannot perform measurements accurately during system transient faults. In the Blue Cut Fire event, there was a phase angle jump of about 26 degrees in the voltage waveform during the transient fault. The phase angle jump fault will cause waveform discontinuity, and these algorithms will fail to provide reliable measurements during this period because they typically assume the waveform to be measured is continuous, no matter what method (DFT, PLL, EKF, FIR, or Taylor WLS) is used for estimation. In fact, the measurement errors during the system transient faults like phase-jump is not required in the IEEE Standard. As a result, although a measurement instrument can pass the strict IEEE Standard, it could still be the source of the problem in the future if we have similar system transient faults, which could happen again. Therefore, developing the fault-tolerant measurement technology is the key to solve the problem.

14 SOLAR ENERGY↗

SU-E-T-482: In Vivo Dosimetry of An Anthropomorphic Phantom by Using the RADPOS System for Proton Beam Therapy

Purpose: Delivered doses in an anthropomorphic phantom were evaluated by using the RADPOS system for proton beam therapy. Methods: The RADPOS in vivo dosimetry system combines an electromagnetic positioning sensor with MOSFET dosimetry, allowing simultaneous online measurements of dose and spatial position. Through the RADPOS system, dose evaluation points can be determined. In vivo proton dosimetry was evaluated by using the RADPOS system and anthropomorphic head and neck phantom. MOSFET doses measured at 3D positions obtained with the RADPOS were compared to the treatment plan values that were calculated by a simplified Monte Carlo (SMC) method. Although the MOSFET response depends strongly on the linear energy transfer (LET) of proton beam, the MOSFET responses to proton beams were corrected with the SMC. Here, the SMC calculated only dose deposition determined by the experimental depth–dose distribution and lateral displacement of protons due to both multiple scattering effect in materials and incident angle. As a Result, the SMC could quickly calculate accurate doses in even heterogeneities. Results: In vivo dosimetry by using the RADPOS, as well as the MOSFET doses agreed in comparison with calculations by the SMC in the range of −3.0% to 8.3%. Most measurement errors occurred because of the uncertainties of dose calculations due to the position error of 1 mm. Conclusion: We evaluated the delivered doses in the anthropomorphic phantom by using the RADPOS system for proton beam therapy. The MOSFET doses agreed in comparison with calculations by the SMC within the measurement error. Therefore, we could successfully control the uncertainties of the measurement positions by using the RADPOS system within 1 mm in in vivo proton dosimetry. We aim for the clinical application of in vivo proton dosimetry with this RADPOS system.

60 APPLIED LIFE SCIENCES↗

An Ultra-Precise System for Electrical Resistivity Tomography Measurements

The objective of this research was to determine the feasibility of building and operating an ERT system that will allow measurement precision that is an order of magnitude better than existing systems on the market today and in particular if this can be done without significantly greater manufacturing or operating costs than existing commercial systems. Under this proposal, we performed an estimation of measurement errors in galvanic resistivity data that arise as a consequence of the type of electrode material used to make the measurements. In our laboratory, measurement errors for both magnitude and induced polarization (IP) were estimated using the reciprocity of data from an array of electrodes as might be used for electrical resistance tomography using 14 different metals as well as one non-metal - carbon. In a second phase of this study, using archival data from two long-term ERT surveys, we examined long-term survivability of electrodes over periods of several years. The survey sites were: the Drift Scale Test at Yucca Mountain, Nevada (which was sponsored by the U. S. Department of Energy as part of the civilian radioactive waste management program), and a water infiltration test at a site adjacent to the New Mexico Institute of Mines and Technology in Socorro, New Mexico (sponsored by the Sandia/Tech vadose program). This enabled us to compare recent values with historical values and determine electrode performance over the long-term as well as the percentage of electrodes that have failed entirely. We have constructed a prototype receiver system, made modifications and revised the receiver design. The revised prototype uses a new 24 bit analog to digital converter from Linear Technologies with amplifier chips from Texas Instruments. The input impedance of the system will be increased from 107 Ohms to approximately 1010 Ohms. The input noise level of the system has been decreased to approximately 10 Nanovolts and system resolution to about 1 Nanovolt at the highest gain range of 125 to 1. The receiver also uses very high precision and high temperature stability components. The goal is to improve the accuracy to better than 0.1%. The system has more receiver channels, eight, to allow efficient data collection at lower base frequencies. We are also implementing a frequency-domain acquisition mode in addition to the time-domain acquisition mode used in the earlier systems. Initial field tests were started in the fall of 2008. We conducted tests on a number of types of cable commonly used for resistivity surveys. A series of different tests were designed to determine if the couplings were primarily resistive, capacitive, or inductive in nature and to ascertain that the response was due to the cable cross-talk and did not depend on the receiver electronics. The results show that the problem appears to be primarily capacitive in nature and does not appear to be due to problems in the receiver electronics. Thus a great deal of emphasis has been placed on finding appropriate cables as well as stable electrodes that have low contact impedance at the very low current flows observed at the receiver. One of the issues in survey design and data collection has been determining how long one must wait before using the same electrode as a transmitter and as a receiver. A series of tests was completed in the laboratory sand tank where four-electrode measurements were made using the same dipole transmitters and dipole receivers (the dipoles used adjacent electrodes). For each data series, a single set of normal measurements were collected with no reciprocals and electrodes were never reused as a receiver after being used as a transmitter. After waiting a specified length of time, the reciprocal measurements were collected using a schedule of measurements. The order of this second schedule was rearranged such that if this second set of measurements were performed without first using the normal schedule, no electrode would be used as a receiver after being used as a transmitter. For this study, we cannot conclude that increasing the wait time increased or decreased the reciprocal errors, only that there was not a dramatic change in results with different wait times. Another issue in ERT data collection is the potential for the transmitter as well as the receiver end of an ERT system to create problems with reciprocity readings. Existing ERT systems typically use a constant voltage source. For the transmitter dipole, a constant voltage source has low output impedance, whereas a constant current source has high output impedance. Therefore, we devised an experiment to determine if a constant current source transmitter might produce smaller errors than a constant voltage source. These preliminary results suggest there is little or no difference in either resistivity or chargeability reciprocal errors using a constant voltage or constant current dipole drive source.

47 OTHER INSTRUMENTATION↗

PDE-constrained high-order mesh optimization

Here, we present a novel framework for PDE-constrained r-adaptivity of high-order meshes. The proposed method formulates mesh movement as an optimization problem, with an objective function defined as a convex combination of a mesh quality metric and a measure of the accuracy of the PDE solution obtained via finite element discretization. The proposed formulation achieves optimized, well-defined high-order meshes by integrating mesh quality control, PDE solution accuracy, and robust gradient regularization. We adopt the Target-Matrix Optimization Paradigm to control geometric properties across the mesh, independent of the PDE of interest. To incorporate the accuracy of the PDE solution, we introduce error measures that control the finite element discretization error. The implicit dependence of these error measures on the mesh nodal positions is accurately captured by adjoint sensitivity analysis. Additionally, a convolution-based gradient regularization strategy is used to ensure stable and effective adaptation of high-order meshes. We demonstrate that the proposed framework can improve mesh quality and reduce the error by up to 10 times for the solution of Poisson and linear elasto-static problems. The approach is general with respect to the dimensionality, the order of the mesh, the types of mesh elements, and can be applied to any PDE that admits well-defined adjoint operators.

Computer science↗

Novel Lightweight, Low-Cost Heliostat for Concentrating Solar Power (SBIR Phase I Final Report)

The overall goal of this Department of Energy (DOE) SBIR Phase I project was to demonstrate the feasibility of the L.Garde, Inc. heliostat mirror facet for use in concentrated solar power applications. Prior to this Phase I project, L.Garde, Inc. developed a design for a lightweight and low cost mirror facet and successfully fabricated small scale (0.667 m 2 ) with a mirror surface flatness of 0.7 mrad. Therefore, the focus of the Phase I effort was to (1) demonstrate scalability by fabricating larger size mirrors while retaining the same mirror surface flatness, (2) demonstrate the design can withstand operating environment conditions through field testing, and (3) perform cost analysis to show the heliostat mirror facet design can meet DoE goals of < 12 kg/m2 and <$30/m 2 . During the Phase I project, L.Garde successfully fabricated large area (1.395 m 2 ) heliostat mirror facets, with a mass per unit area of 8 kg/m 2 and a cost of $29.80/m 2 . Surface flatness measurements (using contact probe technique) were performed on the mirror surface and results showed a flatness of 0.68 mrad, which were in agreement with previously fabricated small scale mirror facets. Slope error measurements was also performed on the mirror surface and results showed a slope error of 0.77 mrad which also was in agreement with previously fabricated small scale mirror facets. One large area mirror facet was subjected to a three (3) month field test. Surface flatness and slope error measurements were performed on the mirror surface after the field test and results were 0.663 mrad and 0.58 mrad respectively. The large scale heliostat mirror facets were also subjected to accelerated aging. However, during this exposure we observed failure due to the breaking of the mirror facets. Further investigation into the source of the failure showed that the mirror component alone showed signs of degradation during the same accelerated aging test. We believe that moisture ingress is occurring when subjected to high humidity, leading to buildup of water with the layers of protective paints and resulting in mirror breakage when water expands in freezing conditions. In order to mitigate or eliminate this issue, a new weatherproofing strategy may be implemented or a new mirror component may be used that is able to survive accelerated aging conditions.

14 SOLAR ENERGY↗

Development of Readily Available & Robust High Heat Flux Gardon Gauges

Concentrated solar power (CSP) technologies deliver concentrated solar energy as a heat source to industrial processes, power generation cycles, and chemical cycles. CSP systems require accurate and reliable high flux measurements, and next generation CSP systems will require flux measurement up to 1000 W/cm2. Existing flux measurement devices do not comprehensively meet the flux rating, cycle life, cost, and lead-time needs of stakeholders, necessitating the development of an improved flux sensor. In this study, Sandia National Laboratories (SNL) partnered with Hukseflux Thermal Sensors to develop a low-cost, short lead-time, and robust flux sensor rated to 250 W/cm2. Three prototype circular foil gauge designs were assessed for performance at the National Solar Thermal Test Facility (NSTTF) at SNL. Each gauge design measured flux up to 250 W/cm2 with <5% measurement error. Following baseline error quantification, gauges were exposed to flux above 500 W/cm2 to assess gauge failure mechanisms. Gauges physically survived >500 W/cm2 flux exposure, but measurement error was found to increase after foil coatings reached 400 °C. The results of this study suggest that coating optical properties change at excessive temperatures and that foil coating temperature, rather than heat flux level, dictates the acceptable gauge measurement range.

McLaughlin, Luke (ORCID:0000000303711310)↗

MAPPING THE GAS TURBULENCE IN THE COMA CLUSTER: PREDICTIONS FOR ASTRO-H

Astro-H will be able for the first time to map gas velocities and detect turbulence in galaxy clusters. One of the best targets for turbulence studies is the Coma cluster, due to its proximity, absence of a cool core, and lack of a central active galactic nucleus. To determine what constraints Astro-H will be able to place on the Coma velocity field, we construct simulated maps of the projected gas velocity and compute the second-order structure function, an analog of the velocity power spectrum. We vary the injection scale, dissipation scale, slope, and normalization of the turbulent power spectrum, and apply measurement errors and finite sampling to the velocity field. We find that even with sparse coverage of the cluster, Astro-H will be able to measure the Mach number and the injection scale of the turbulent power spectrum—the quantities determining the energy flux down the turbulent cascade and the diffusion rate for everything that is advected by the gas (metals, cosmic rays, etc.). Astro-H will not be sensitive to the dissipation scale or the slope of the power spectrum in its inertial range, unless they are outside physically motivated intervals. We give the expected confidence intervals for the injection scale and the normalization of the power spectrum for a number of possible pointing configurations, combining the structure function and velocity dispersion data. Importantly, we also determine that measurement errors on the line shift will bias the velocity structure function upward, and show how to correct this bias.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic Errors in measurement of b1

A class of spin observables can be obtained from the relative difference of or asymmetry between cross sections of different spin states of beam or target particles. Such observables have the advantage that the normalization factors needed to calculate absolute cross sections from yields often divide out or cancel to a large degree in constructing asymmetries. However, normalization factors can change with time, giving different normalization factors for different target or beam spin states, leading to systematic errors in asymmetries in addition to those determined from statistics. Rapidly flipping spin orientation, such as what is routinely done with polarized beams, can significantly reduce the impact of these normalization fluctuations and drifts. Target spin orientations typically require minutes to hours to change, versus fractions of a second for beams, making systematic errors for observables based on target spin flips more difficult to control. Such systematic errors from normalization drifts are discussed in the context of the proposed measurement of the deuteron b(1) structure function at Jefferson Lab.

Wood, S A↗

Study of radial potential fluctuations by using a gold neutral beam probe system

A study of fluctuation is one of the main issues in fusion plasma researches. The potential and its fluctuation are measured by a gold neutral beam probe (GNBP) in the tandem mirror GAMMA10. Since there is no stable isotope ({sup 197}Au{approx}100%), there are little measurement errors. GNBP system can measure the potential with about {+-}30 V of error. The time and spatial resolutions are estimated to be about 3 {mu}s and 5 mm, respectively. During the formation of axial confining potentials, the radial profiles of the potential and its fluctuation were successfully measured in GAMMA10. GNBP is a useful tool for the study of radial potential fluctuation directly in plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗