Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned electrode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Fast, Large-Area, Wide-Bandgap UV Photodetector for Cherenkov Light Detection

Due to limited resources available for power and space for payloads, miniaturizing and integrating instrumentation is a high priority for addressing the challenges of manned and unmanned deep space missions to high Earth orbit (HEO), near Earth objects (NEOs), Lunar and Martian orbits and surfaces, and outer planetary systems, as well as improvements to high-altitude aircraft safety. New, robust, and compact detectors allow future instrumentation packages more options in satisfying specific mission goals. A solid-state ultraviolet (UV) detector was developed with a theoretical fast response time and large detection area intended for application to Cherenkov detectors. The detector is based on the wide-bandgap semiconductor zinc oxide (ZnO), which in a bridge circuit can detect small, fast pulses of UV light like those required for Cherenkov detectors. The goal is to replace the role of photomultiplier tubes in Cherenkov detectors with these solid-state devices, saving on size, weight, and required power. For improving detection geometry, a spherical detector to measure high atomic number and energy (HZE) ions from any direction has been patented as part of a larger space radiation detector system. The detector will require the development of solid-state UV photodetectors fast enough (2 ns response time or better) to detect the shockwave of Cherenkov light emitted as the ions pass through a quartz, sapphire, or acrylic ball. The detector must be small enough to fit in the detector system structure, but have an active area large enough to capture enough Cherenkov light from the sphere. The detector is fabricated on bulk single-crystal undoped ZnO. Inter - digitated finger electrodes and contact pads are patterned via photolithography, and formed by sputtered metal of silver, platinum, or other high-conductivity metal.

Wrbanek, John D.↗

Optimizing Fast Charging and Wetting in Lithium-Ion Batteries with Optimal Microstructure Patterns Identified by Genetic Algorithm

To sustain the high-rate current required for fast charging electric vehicle batteries, electrodes must exhibit sufficiently high effective ionic diffusion. Additionally, to reduce battery manufacturing costs, wetting time must decrease. Both of these issues can be addressed by structuring the electrodes with mesoscale pore channels. However, their optimal spatial distribution, or patterns, is unknown. Herein, a genetic algorithm has been developed to identify these optimal patterns using a CPU-cheap proxy distance-based model to evaluate the impact of the added pore networks. Both coin-cell and pouch cell form factors have been considered for the wetting analysis, with their respective electrolyte infiltration mode. Regular hexagonal and mud-crack-like patterns, respectively, for fast charging and fast wetting were found to be optimal and have been compared with pre-determined, easier to manufacture, patterns. The model predicts that using cylindrical channels arranged in a regular hexagonal pattern is ∼6.25 times more efficient for fast charging as compared to grooved lines with both structuring strategies being restricted to a 5% electrode total volume loss. The model also shows that only a very limited electrode volume loss (1%–2%) is required to dramatically improve the wetting (5–20 times) compared to an unstructured electrode.

25 ENERGY STORAGE↗

Synchrotron small-angle X-ray scattering technique for battery electrode study

Structure dependent stability is a concern for the achievement of high energy density electrode with long cycling lifetime, especially for alloying-type and conversion-type anodes. Substantial alterations in volume upon discharge-discharge process leads to particle pulverization and continuous consumption of electrolyte. Moreover, the nucleation and growth mechanism of Li 2 O and Li 2 S, which determines the rate performance of Li-O 2 and Li-S batteries, are still understudy. Microstructure characterization techniques have been applied to disclose the structural changes of active material at different charge/discharge states. Synchrotron small-angle X-ray scattering (SAXS) attracts considerable attention because of the high flux, high time resolution and nondestructive characteristics. In addition, SAXS patterns provide statistics structural information of electrode at micrometer scale. The commonly used coin cell with punched holes simplifies the application of in situ/operando SAXS measurement. Here, this review discusses the research about the SAXS technique in the characterization of electrode in different batteries.

25 ENERGY STORAGE↗

Spatially Patterned Architectures to Modulate CO 2 Reduction Cascade Catalysis Kinetics

Electrochemical CO 2 reduction using renewable sources of electrical energy holds promise for converting CO 2 into fuels and chemicals. The complex interactions among chemical/electrochemical reactions and mass transport make it difficult to analyze the effect of an individual process on electrode performance based only on experimental methods. Here, we developed a generalized steady-state simulation to describe an electrode surface in which sequential cascade catalysts are patterned in a periodic trench design. If appropriately constructed, this trench geometry is hypothesized to be able to yield a higher net current density for a CO 2 reduction (CO 2 R) cascade reaction. We have used realistic experimental reaction kinetics to investigate the role of trench geometry in mass transport, local microenvironments, and selectivity for a model CO 2 R cascade reaction. The model considers local concentration gradients of bicarbonate species at quasi-equilibrium and catalytic surface reactions based on concentration-dependent Butler–Volmer kinetics. Our results suggest that varying the spatial distribution of active sites plays a significant role in facilitating effective mass transport between active sites, modulating selectivity for the cascade reaction, and enhancing the yield of desirable cascade products. Moreover, we observe that this trench geometry significantly alters the cascade reaction rate by affecting the local pH, which can cause inadvertent depletion of available aqueous CO 2 to limit the CO 2 R cascade kinetics and modest suppression of the hydrogen evolution reaction (HER). The results highlight the trade-offs between mass transport, pH, and reaction kinetics that become apparent only when considering the coupled physics of all processes at the electrode surface. Here, this model can thus serve as a primary tool to build more selective and efficient patterned architectures for the CO 2 R cascade catalysis.

CO2 reduction↗

Fast, Large Area, Wide Band GAP UV Photodetector for Cherenkov Light Detection

A solid-state radiation detector includes a pattern of conductive metal on a zinc oxide substrate. The pattern provides an arrangement of interdigitated electrode fingers. The wide band gap substrate is sensitive to UV light, which can cause a conductivity change in the substrate. The electrode fingers are configured to sense a difference in substrate conductivity resulting from UV light. The detector has a fast response time, which enables it to detect Cherenkov light. The compact detector provides savings on size, weight, and required power. Thus, the solid-state detector can be used to replace photomultiplier tubes in Cherenkov detectors. The features of the novel detector allow for an improved system to detect and monitor UV radiation, especially during deep space missions.

Wrbanek, John D.↗

Multielectrode electrochemical cell for in situ structural characterization of amorphous thin-film catalysts using high-energy X-ray scattering

A multielectrode-based electrochemical cell allows the structural characterization of an amorphous thin-film water oxidation catalyst under various electrochemical potentials using high-energy X-ray scattering and atomic pair distribution function (PDF) techniques. A multielectrode with five electrodes provides a sufficiently low background signal to enable high-energy X-ray scattering (HEXS) measurements and amplifies the extremely low HEXS signals from samples for high-resolution PDF analysis of in situ data from thin-film catalysts. Glassy carbon (GC) creates a relatively low intensity HEXS pattern and is used as a working electrode. Instead of a three-dimensional (3D) porous electrode architecture, the flat geometry of the electrode enables various deposition techniques to be used for the preparation of a highly conductive metal oxide layer. PDF analysis demonstrates high spatial resolution for a 230 nm thick amorphous iridium oxide film deposited on two roughened 60 µm thick GC electrodes. The PDF analysis resolves the domain size and distinguishes changes in fine structure which are directly correlated with the structure and function of the catalysts. In conclusion, the results bring the opportunity to analyze the structure of nanometre-scale amorphous thin-film catalysts in an electrolyte-compatible and compact 3D-printed electrochemical cell in a three-electrode configuration.

36 MATERIALS SCIENCE↗

A computational modeling framework for pre-clinical evaluation of cardiac mapping systems

There are a variety of difficulties in evaluating clinical cardiac mapping systems, most notably the inability to record the transmembrane potential throughout the entire heart during patient procedures which prevents the comparison to a relevant “gold standard”. Cardiac mapping systems are comprised of hardware and software elements including sophisticated mathematical algorithms, both of which continue to undergo rapid innovation. The purpose of this study is to develop a computational modeling framework to evaluate the performance of cardiac mapping systems. The framework enables rigorous evaluation of a mapping system’s ability to localize and characterize (i.e., focal or reentrant) arrhythmogenic sources in the heart. The main component of our tool is a library of computer simulations of various dynamic patterns throughout the entire heart in which the type and location of the arrhythmogenic sources are known. Our framework allows for performance evaluation for various electrode configurations, heart geometries, arrhythmias, and electrogram noise levels and involves blind comparison of mapping systems against a “silver standard” comprised of computer simulations in which the precise transmembrane potential patterns throughout the heart are known. A feasibility study was performed using simulations of patterns in the human left atria and three hypothetical virtual catheter electrode arrays. Activation times (AcT) and patterns (AcP) were computed for three virtual electrode arrays: two basket arrays with good and poor contact and one high-resolution grid with uniform spacing. The average root mean squared difference of AcTs of electrograms and those of the nearest endocardial action potential was less than 1 ms and therefore appears to be a poor performance metric. In an effort to standardize performance evaluation of mapping systems a novel performance metric is introduced based on the number of AcPs identified correctly and those considered spurious as well as misclassifications of arrhythmia type; spatial and temporal localization accuracy of correctly identified patterns was also quantified. This approach provides a rigorous quantitative analysis of cardiac mapping system performance. Proof of concept of this computational evaluation framework suggests that it could help safeguard that mapping systems perform as expected as well as provide estimates of system accuracy.

59 BASIC BIOLOGICAL SCIENCES↗

Recent Advances in Scalable, High‐Mass Loaded Electrodes for Grid‐Scale Energy Storage

Abstract The increasing electrification of daily life as well as the intermittent characteristic of renewable energy sources require viable solutions for grid‐scale energy storage. Critical considerations for grid storage applications are electrode mass loading and electrode thickness as these features govern battery pack energy density, an important factor in determining manufacturing costs. For this reason, there is increased interest in finding new ways of creating electrodes with high mass loading. In this review, various high‐mass loading fabrication approaches are considered for positive electrode materials used in batteries. The benchmark used for high mass loading is above 20 mg cm −2 , which is higher than the practical limit of conventional tape‐cast electrodes. Several different electrode approaches are described including templating, laser patterning, direct ink writing, and electrodeposition. A variety of materials are covered with the most prominent being LiFe(PO 4 ) (LFP), LiCoO 2 (LCO), and MnO 2 . In research to date, scalable electrochemical performance has been achieved with mass loadings over 100 mg cm −2 . Areal capacities as high as 14.7 mAh cm −2 at 1.82 mA cm −2 have been achieved in non‐aqueous electrolytes and 9.8 mAh cm −2 at 10 mA cm −2 in aqueous electrolytes. These results establish that the mass loading of electrodes can be scaled up without compromising their electrochemical properties.

White, Makena [Department of Materials Science and↗

Electrochemistry-Induced Direct Deposition of Nanoscale Thin Zeolitic Imidazolate Framework-8 Films on Insulator Substrates

Electrochemical approaches have been explored as controlled means to prepare thin films of metal–organic frameworks (MOFs) on electrodes but have rarely been used to form insulator films on insulator surfaces. Herein, we report an electrochemistry-based approach to direct deposition of a thin film of zeolitic imidazolate framework-8 (ZIF-8) onto an insulator surface. The film deposition was induced by a cathodic reaction at an electrode that was placed above the insulator with a separation of ≈100 μm in a methanol solution containing ZnCl 2 and 2-methylimidizole. The effects of the electrode and insulator material, applied potential, electrode–substrate distance, deposition time, and the number of deposition cycles were systematically investigated to gain insight into the deposition mechanism. The results of these measurements were consistent with a hypothesized mechanism involving cathodic base generation at the working electrode for ligand deprotonation, formation of intermediate species, their diffusion toward the substrate, and the formation of ZIF-8 on the substrate. Interestingly, the size, shape, and position of the film on the substrate replicated those of the working electrode, showing the applicability of this approach to the patterned deposition of a ZIF-8 film. In addition, film thickness could be easily controlled in the range of tens to hundreds of nanometers by adjusting the potential application conditions. Furthermore, this electrochemistry-induced method will provide a simple means for the patterned formation of a MOF film of controlled thickness on an insulator without metal precoating and thus will open the possibility of designing unique devices for various applications including chemical sensing and separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Currents between tethered electrodes in a magnetized laboratory plasma

Laboratory experiments on important plasma physics issues of electrodynamic tethers were performed. These included current propagation, formation of wave wings, limits of current collection, nonlinear effects and instabilities, charging phenomena, and characteristics of transmission lines in plasmas. The experiments were conducted in a large afterglow plasma. The current system was established with a small electron-emitting hot cathode tethered to an electron-collecting anode, both movable across the magnetic field and energized by potential difference up to V approx.=100 T(sub e). The total current density in space and time was obtained from complete measurements of the perturbed magnetic field. The fast spacecraft motion was reproduced in the laboratory by moving the tethered electrodes in small increments, applying delayed current pulses, and reconstructing the net field by a linear superposition of locally emitted wavelets. With this technique, the small-amplitude dc current pattern is shown to form whistler wings at each electrode instead of the generally accepted Alfven wings. For the beam electrode, the whistler wing separates from the field-aligned beam which carries no net current. Large amplitude return currents to a stationary anode generate current-driven microinstabilities, parallel electric fields, ion depletions, current disruptions and time-varying electrode charging. At appropriately high potentials and neutral densities, excess neutrals are ionized near the anode. The anode sheath emits high-frequency electron transit-time oscillations at the sheath-plasma resonance. The beam generates Langmuir turbulence, ion sound turbulence, electron heating, space charge fields, and Hall currents. An insulated, perfectly conducting transmission line embedded in the plasma becomes lossy due to excitation of whistler waves and magnetic field diffusion effects. The implications of the laboratory observations on electrodynamic tethers in space are discussed.

Stenzel, R. L.↗

Structural Changes during the Conversion Reaction of Tungsten Oxide Electrodes with Tailored, Mesoscale Porosity

In-plane tungsten oxide nanostructures, including hexagonally patterned cylinders and holes in a matrix, were fabricated via sequential infiltration synthesis (SIS) on self-assembled block copolymer templates. Using the tailored morphology and porosity of these model electrodes with in situ grazing incidence small angle X-ray scattering, the intrinsic structural change of nanoscale active materials during the conversion reaction of WO 3 + 6Li ↔ W + 3 Li 2 O was investigated at controlled electrochemical conditions. Reversible electrode volume expansion and contraction was observed during lithiation and delithiation cycles, respectively. The potential where electrode’s thickness expansion started was ~1.6 V, which is close to thermodynamically expected one for conversion reaction of WO 3 with lithium (1.65 V). The temporal evolution of the electrode volume at constant electrode potentials revealed high overpotential for bulk lithiation and slow conversion reaction kinetics, despite the tailored porosity of the SIS electrodes. Oxide cylinders showed smaller overall electrode thickness change, likely due to unconstrained lateral volume change, as compared to a matrix with holes. On the other hand, better connectivity and guided volume change of the latter electrode morphology provided improved cycling stability. Additionally, heterogeneity in an electrode, from internal pores and density gradients, was found to aggravate the fragmentation of the electrode during conversion reaction. Insights into oxide conversion reaction kinetics and the relationship between electrode mesostructure and cycling behavior obtained from this study can help guide the more rational design of conversion electrode for high performing batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary Investigation of an Active PLZT Lens

The design, analysis and preliminary testing of a prototype Adjustable Focus Optical Correction Lens (AFOCL) is described. The AFOCL is an active optical component composed of solid state lead lanthanum-modified zirconate titanate (PLZT) ferroelectric ceramic with patterned indium tin oxide (ITO) transparent surface electrodes that modulate the refractive index of the PLZT to function as an electro-optic lens. The AFOCL was developed to perform optical re-alignment and wavefront correction to enhance the performance of Ultra-Lightweight Structures and Space Observatories (ULSSO). The AFOCL has potential application as an active optical component within a larger optical system. As such, information from a wavefront sensor would be processed to provide input to the AFOCL to drive the sensed wavefront to the desired shape and location. While offering variable and rapid focussing capability (controlled wavefront manipulation) similar to liquid crystal based spatial light modulators (SLM), the AFOCL offers some potential advantages because it is a solid-state, stationary, low-mass, rugged, and thin optical element that can produce wavefront quality comparable to the solid refractive lens it replaces. The AFOCL acts as a positive or negative lens by producing a parabolic phase-shift in the PLZT material through the application of a controlled voltage potential across the ITO electrodes. To demonstrate the technology, a 4 mm diameter lens was fabricated to produce 5-waves of optical power operating at 2.051 micrometer wavelength. Optical metrology was performed on the device to measure focal length, optical quality, and efficiency for a variety of test configurations. The data was analyzed and compared to theoretical data available from computer-based models of the AFOCL.

Lightsey, W. D.↗

Applications of Gas Imaging Micro-Well Detectors to an Advanced Compton Telescope

We present a concept for an Advanced Compton Telescope (ACT) based on the use of pixelized gas micro-well detectors to form a three-dimensional electron track imager. A micro-well detector consists of an array of individual micro-patterned proportional counters opposite a planar drift electrode. When combined with thin film transistor array readouts, large gas volumes may be imaged with very good spatial and energy resolution at reasonable cost. The third dimension is determined by timing the drift of the ionization electrons. The primary advantage of this approach is the excellent tracking of the Compton recoil electron that is possible in a gas volume. Such good electron tracking allows us to reduce the point spread function of a single incident photon dramatically, greatly improving the imaging capability and sensitivity. The polarization sensitivity, which relies on events with large Compton scattering angles, is particularly enhanced. We describe a possible ACT implementation of this technique, in which the gas tracking volume is surrounded by a CsI calorimeter, and present our plans to build and test a small prototype over the next three years.

Bloser, P. F.↗

Carbon Nanotube-Based Structural Health Monitoring Sensors

Carbon nanotube (CNT)-based sensors for structural health monitoring (SHM) can be embedded in structures of all geometries to monitor conditions both inside and at the surface of the structure to continuously sense changes. These CNTs can be manipulated into specific orientations to create small, powerful, and flexible sensors. One of the sensors is a highly flexible sensor for crack growth detection and strain field mapping that features a very dense and highly ordered array of single-walled CNTs. CNT structural health sensors can be mass-produced, are inexpensive, can be packaged in small sizes (0.5 micron(sup 2)), require less power than electronic or piezoelectric transducers, and produce less waste heat per square centimeter than electronic or piezoelectric transducers. Chemically functionalized lithographic patterns are used to deposit and align the CNTs onto metallic electrodes. This method consistently produces aligned CNTs in the defined locations. Using photo- and electron-beam lithography, simple Cr/Au thin-film circuits are patterned onto oxidized silicon substrates. The samples are then re-patterned with a CNT-attracting, self-assembled monolayer of 3-aminopropyltriethoxysilane (APTES) to delineate the desired CNT locations between electrodes. During the deposition of the solution-suspended single- wall CNTs, the application of an electric field to the metallic contacts causes alignment of the CNTs along the field direction. This innovation is a prime candidate for smart skin technologies with applications ranging from military, to aerospace, to private industry.

Wincheski, Russell↗

Graphene Transparent Conductive Electrodes for Next- Generation Microshutter Arrays

Graphene is a single atomic layer of graphite. It is optically transparent and has high electron mobility, and thus has great potential to make transparent conductive electrodes. This invention contributes towards the development of graphene transparent conductive electrodes for next-generation microshutter arrays. The original design for the electrodes of the next generation of microshutters uses indium-tin-oxide (ITO) as the electrode material. ITO is widely used in NASA flight missions. The optical transparency of ITO is limited, and the material is brittle. Also, ITO has been getting more expensive in recent years. The objective of the invention is to develop a graphene transparent conductive electrode that will replace ITO. An exfoliation procedure was developed to make graphene out of graphite crystals. In addition, large areas of single-layer graphene were produced using low-pressure chemical vapor deposition (LPCVD) with high optical transparency. A special graphene transport procedure was developed for transferring graphene from copper substrates to arbitrary substrates. The concept is to grow large-size graphene sheets using the LPCVD system through chemical reaction, transfer the graphene film to a substrate, dope graphene to reduce the sheet resistance, and pattern the film to the dimension of the electrodes in the microshutter array. Graphene transparent conductive electrodes are expected to have a transparency of 97.7%. This covers the electromagnetic spectrum from UV to IR. In comparison, ITO electrodes currently used in microshutter arrays have 85% transparency in mid-IR, and suffer from dramatic transparency drop at a wavelength of near-IR or shorter. Thus, graphene also has potential application as transparent conductive electrodes for Schottky photodiodes in the UV region.

Li, Mary↗

DFT simulation of the X-ray diffraction pattern of aluminum-ion-intercalated graphite used as the cathode material of the aluminum-ion battery

Many breakthroughs have been achieved in rechargeable aluminum-ion battery technologies in recent years. Most recently, operando X-ray diffraction (XRD) combined with density functional theory (DFT) calculations was reported to study the chloroaluminate anion (AlCl 4 -)-intercalated graphite cathode of the battery. However, there are quite a few discrepancies between the measured and simulated XRD patterns. This work is focused on the simulation of XRD patterns of graphite intercalation compounds (GICs) with DFT calculations. Our results reveal that both the geometry of AlCl 4 - in graphite and the gallery height of GICs are dependent on the intercalant density. At low intercalant density, the gallery height keeps constant, but at high intercalant densities, the gallery height is linearly related to the intercalant density. Our simulated XRD patterns are highly consistent with the measured operando XRD patterns. Not only do the angles of the peaks match very well, but also the relative intensities and the corresponding electrode capacities show reasonable agreement with the experimental results. The DFT simulation of the XRD pattern provides significant information on the stage index and the charge capacity of the GIC electrode.

25 ENERGY STORAGE↗

Electrostatic powder spreading for metal powder bed fusion applications

Typical powder bed fusion processes spread each layer of powder by pushing it across the build area with a spreader bar or roller. While simple, these methods require good flowing powder and do not have the ability to place more than one powder type per layer. This naturally limits the ability to incorporate more than one material onto each powder layer in powder bed additive manufacturing processes. Here we demonstrate electrostatic powder spreading, a method to deposit a powder layer without mechanical contact with the previous layers. Electrostatic powder spreading (ESPS) uses an electric field formed between a powder container and a counter electrode to move powder particles from the container to the powder bed. We show that the rate at which powder is deposited can be controlled by adjusting the strength of the electric field. Correspondingly, the deposited layer thickness is controlled by the strength of the electric field and the recoating speed. To demonstrate the feasibility of ESPS for laser powder bed fusion powder spreading, nearly fully dense (> 99.8%) coupons were built in a commercial L-PBF machine using the ESPS setup. Finally, we achieve 2D patterning of a single layer by using an array of electrodes and switching the applied electric field on and off. ESPS represents a method to produce an arbitrary patterned multi-material powder bed without complicated powder removal steps and easy implementation into existing L-PBF machines. Furthermore, ESPS presents an opportunity to build parts with 3D gradients in material properties.

36 MATERIALS SCIENCE↗