Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

2024 Annual Technology Baseline (ATB) Cost and Performance Data for Electricity Generation Technologies

These data provide the 2024 update of the Electricity Annual Technology Baseline (ATB). Starting in 2015 NREL has presented the ATB, consisting of detailed cost and performance data, both current and projected, for electricity generation and storage technologies. The ATB products now include data (Excel workbook, Tableau workbooks, and structured summary csv files), as well as documentation and user engagement via a website, presentation, and webinar. Starting in 2021, the data are cloud optimized and provided in the OEDI data lake. The data for 2015 - 2020 are can be found on the NREL Data Search Page. The website documentation can be found on the ATB Website.

Array↗

Delta VLBI data performance in the Galileo spacecraft Earth flyby of December 1990

The performance of the delta very long baseline interferometry (Delta VLBI) data type during the recent Earth flyby of the Galileo spacecraft is presented. First, the data are given significance by showing why the mission design requires an accurate flyby. Then, the data's performance is analyzed, including its operational features, as well as its accuracy. Finally, the effectiveness of these data in improving the accuracy of flyby is shown. Comparisons are made between the expected and actual performances of the data. The processing time, reliability, and accuracy of these data were very good, and a solid gain was made in the encounter accuracy.

Gray, D. L.↗

Performance data for a terrestrial solar photovoltaic/water electrolysis experiment

A description is presented of the equipment used in the experiment, taking into account the surplus solar panel from the Mariner 4 spacecraft which was used as a solar array source and an electrolytic hydrogen generator. Attention is also given to operational considerations and performance data, system considerations and aspects of optimization, and large-scale hydrogen production considerations.

Costogue, E. N.↗

Building Battery Energy Storage System Performance Data into an Economic Assessment

Economic assessments of battery energy storage systems (BESSs) rely on optimal dispatch methods to capture temporal interdependency of BESS operations and coupling among different grid applications. Many existing BESS economic assessment studies are based on a simplified first-order scalar model using BESS nameplate numbers. Such a method cannot accurately capture varying capabilities and nonlinear dynamics of a BESS, leading to inaccurate assessment results. This paper presents a practical implementation of performance data into the economic assessment of the BESSs recently developed within the Snohomish Public Utility District system in Washington State. Extensive testing conducted over multiple seasons is used to assess the technical performance and develop high-fidelity models of the BESSs. A dynamic programming algorithm is proposed to optimally dispatch the BESSs and assess the potential benefits from stacked value streams. The proposed method can be adapted for the economic assessment of other BESSs with different applications.

Wu, Di↗

A Summary Of: Collecting Sleep, Circadian, Fatigue, and Performance Data in Complex Operational Environments

Sleep loss and circadian misalignment contribute to a meaningful proportion of operational accidents and incidents. Countermeasures and work scheduling designs aimed at mitigating fatigue are typically evaluated in controlled laboratory environments, but the effectiveness of translating such strategies to operational environments can be challenging to assess. This manuscript summarizes an approach for collecting sleep, circadian, fatigue, and performance data in a complex operational environment. We studied 44 airline pilots over 34 days while they flew a fixed schedule, which included a baseline data collection with 5 days of mid-morning flights, four early flights, four high-workload mid-day flights, and four late flights that landed after midnight. Each work block was separated by 3-4 days of rest. To assess sleep, participants wore a wrist-worn research-validated activity monitor continuously and completed daily sleep diaries. To assess the circadian phase, pilots were asked to collect all urine produced in four or eight hourly bins during the 24 h after each duty block for the assessment of 6-sulfatoxymelatonin (aMT6s), which is a biomarker of the circadian rhythm. To assess subjective fatigue and objective performance, participants were provided with a touchscreen device used to complete the Samn-Perelli Fatigue Scale and Psychomotor Vigilance Task (PVT) during and after each flight, and at wake-time, mid-day, and bedtime. Using these methods, it was found that sleep duration was reduced during early starts and late finishes relative to baseline. Circadian phase shifted according to duty schedule, but there was a wide range in the aMT6s peak between individuals on each schedule. PVT performance was worse on the early, high-workload, and late schedules relative to baseline. Overall, the combination of these methods was practical and effective for assessing the influence of sleep loss and circadian phase on fatigue and performance in a complex operational environment.

Arsintescu, Lucica↗

Uncertainty of Personnel Dosimetry Systems Using Performance Data Testing

While accreditation programs require a study of uncertainty for each dosimeter model for which accreditation is sought (Torres 2005, DOE 1986), no one method is specifically recommended by accrediting bodies. Typically, the methods used to determine uncertainty have included the partial differentiation method described in the U.S. Guide to Uncertainty in Measurements (ANSI 1997) or the use of Monte Carlo techniques and probability distribution functions to generate simulated dose results. Each of these techniques has particular strengths and should be employed when the areas of uncertainty are required to be understood in detail. However, the uncertainty of dosimeter results can also be determined using a Model II One-Way Analysis of Variance technique and accreditation testing data (Cummings and Flood 2010). The strengths of this method are (1) the method is based in robust and well-accepted statistical techniques; (2) the method is straightforward and easily applied to dose algorithms, which are so complex as to render the use of other methods unwieldy; and (3) the method uses dosimeter performance data obtained during accreditation. The general method and criteria of inclusion of radiation types and fields are discussed.

Cummings, Frederick (Rick) M.↗

Preliminary Transient Performance Data for Afterburner Operation of Westinghouse Electronic Power Regulator on XJ34-WE-32 Turbojet Engine in Altitude Wind Tunnel

At the request of the Bureau of Aeronautics, Department of the Navy, an investigation of the Westinghouse XJ34-WE-32 turbojet engine is being conducted in the NACA Lewis altitude wind tunnel to determine the steady-state and transient operating characteristics of the controlled and uncontrolled engine at various altitudes and ram pressure ratios. As part of this program, transient performance data that illustrate the operation of the engine is obtained in the form of oscillographic traces. Similar data for engine operation i n the afterburning range, covering a range of throttle settings from the minimum value giving rated speed (throttle position, 72 degrees) to full afterburning (throttle position, ll0 degrees), is presented herein. These data thus serve to indicate the transient characteristics of the engine when the throttle is advance into, withdrawn from, and moved within the afterburning range in a stepwise manner, as well as the steady-state stability of the engine during afterburning .

Vasu, George↗

Loads and Performance Data from a Wind-Tunnel Test of Generic Model Helicopter Rotor Blades

An investigation was conducted in the NASA Langley Transonic Dynamics Tunnel to acquire data for use in assessing the ability of current and future comprehensive analyses to predict helicopter rotating-system and fixed-system vibratory loads. The investigation was conducted with a generic model helicopter rotor system using blades with rectangular planform, no built-in twist, uniform radial distribution of mass and stiffnesses, and a NACA 0012 airfoil section. Rotor performance data, as well as mean and vibratory components of blade bending and torsion moments, fixed-system forces and moments, and pitch link loads were obtained at advance ratios up to 0.35 for various combinations of rotor shaft angle-of-attack and collective pitch. The data are presented without analysis.

Yeager, William T., Jr.↗

I/O through High Performance Data Services

The conclusions of this paper are that: (1) moving output data processing to a separate processing area has performance advantages; (2) management of data movement results in large performance gains; (3) the Data Service abstraction enables the development of data staging operations; and (4) using the data service model, we can create adaptive resource aware storage backends.

97 MATHEMATICS AND COMPUTING↗

High-performance data format for scientific data storage and analysis

Here, in this article, we present the High-Performance Output (HiPO) data format developed at Jefferson Laboratory for storing and analyzing data from Nuclear Physics experiments. The format was designed to efficiently store large amounts of experimental data, utilizing modern fast compression algorithms. The purpose of this development was to provide organized data in the output, facilitating access to relevant information within the large data files. The HiPO data format has features that are suited for storing raw detector data, reconstruction data, and the final physics analysis data efficiently, eliminating the need to do data conversions through the lifecycle of experimental data. The HiPO data format is implemented in C++ and JAVA, and provides bindings to FORTRAN, Python, and Julia, providing users with the choice of data analysis frameworks to use. In this paper, we will present the general design and functionalities of the HiPO library and compare the performance of the library with more established data formats used in data analysis in High Energy and Nuclear Physics (such as ROOT and Parquete). In columnar data analysis, HiPO surpasses established data formats in performance and can be effectively applied to data analysis in other scientific fields.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance data of the new free-piston shock tunnel T5 at GALCIT

A new free piston shock tunnel has been constructed at the Graduate Aeronautical Laboratories at Caltec. Compression tube length is 30 m and diameter 300 mm. Shock tube length is 12 m and diameter 90 mm. Piston mass is 150 kg and maximum diaphragm burst pressure is 130 MPa. Special features of this facility are that the pressure in the driver gas is monitored throughout the compression process until well after diaphragm rupture, and that the diaphragm burst pressure can be measured dynamically. An analysis of initial performance data including transient behavior of the flow over models is presented.

Hornung, H.↗

Performance Data from a Wind-Tunnel Test of Two Main-rotor Blade Designs for a Utility-Class Helicopter

An investigation was conducted in the NASA Langley Transonic Dynamics Tunnel to evaluate an advanced main rotor designed for use on a utility class helicopter, specifically the U.S. Army UH-60A Blackhawk. This rotor design incorporated advanced twist, airfoil cross sections, and geometric planform. For evaluation purposes, the current UH-60A main rotor was also tested and is referred to as the baseline blade set. A total of four blade sets were tested. One set of both the baseline and the advanced rotors were dynamically scaled to represent a full scale helicopter rotor blade design. The remaining advanced and baseline blade sets were not dynamically scaled so as to isolate the effects of structural elasticity. The investigation was conducted in hover and at rotor advance ratios ranging from 0.15 to 0.4 at a range of nominal test medium densities from 0.00238 to 0.009 slugs/cu ft. This range of densities, coupled with varying rotor lift and propulsive force, allowed for the simulation of several vehicle gross weight and density altitude combinations. Performance data are presented for all blade sets without analysis; however, cross referencing of data with flight condition may be useful to the analyst for validating aeroelastic theories and design methodologies as well as for evaluating advanced design parameters.

Singleton, Jeffrey D.↗

High-performance data management for whole slide image analysis in digital pathology

When dealing with giga-pixel digital pathology in whole-slide imaging, a notable proportion of data records holds relevance during each analysis operation. For instance, when deploying an image analysis algorithm on whole-slide images (WSI), the computational bottleneck often lies in the input-output (I/O) system. This is particularly notable as patch-level processing introduces a considerable I/O load onto the computer system. However, this data management process could be further paralleled, given the typical independence of patch-level image processes across different patches. This paper details our endeavors in tackling this data access challenge by implementing the Adaptable IO System version 2 (ADIOS2). Our focus has been constructing and releasing a digital pathology-centric pipeline using ADIOS2, which facilitates streamlined data management across WSIs. Additionally, we’ve developed strategies aimed at curtailing data retrieval times. The performance evaluation encompasses two key scenarios: (1) a pure CPU-based image analysis scenario (“CPU scenario”), and (2) a GPU-based deep learning framework scenario (“GPU scenario”). Our findings reveal noteworthy outcomes. Under the CPU scenario, ADIOS2 showcases an impressive two-fold speed-up compared to the brute-force approach. In the GPU scenario, its performance stands on par with the cutting-edge GPU I/O acceleration framework, NVIDIA Magnum IO GPU Direct Storage (GDS). From what we know, this appears to be among the initial instances, if any, of utilizing ADIOS2 within the field of digital pathology. The source code has been made publicly available at https://github.com/hrlblab/adios.

Wang, Xiao↗

Nuclear Data and Benchmarking Program: Nuclear Data Performance Assessment for Advanced Reactors

Over the last several Evaluated Nuclear Data File (ENDF)/B releases, many updates have been introduced to the nuclear data libraries that can significantly change computational results. These changes can be particularly important for advanced reactor concepts, which are not as thoroughly investigated as those used in light water reactor (LWR) systems. Therefore, a performance assessment of the ENDF/B libraries using the SCALE 6.2.3 code package was conducted under the auspices of the U.S., Department of Energy Office of Nuclear Energy (DOE-NE). The following systems relevant to the advanced reactor community were chosen as subject for investigation in this report: sodium cooled fast reactor systems, graphite moderated high temperature gas-cooled reactors, and several molten salt reactor models. At first, the similarity of the integral performance of the ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear data libraries caused by compensating errors in important differential data was demonstrated. In calculations for a shipping container of high-assay low enriched uranium, the data of individual isotopes were systematically swapped between the two ENDF/B libraries. An eigenvalue difference of up to 450 pcm was found due to the use of 235 U and 238 U from one library and 1 H and 16 O from the other library. This clearly demonstrates a cross-correlation between reaction data sets of different isotopes within a library that should be reported in the evaluations. For sodium-cooled fast reactor (SFR) fuel assemblies, significant eigenvalue (k inf ) differences (200– 450 pcm) were found between calculations using the 2011 ENDF/B-VII.1 data and 2018 ENDF/B-VIII.0 data. These differences were mainly caused by updates of 238 U and 239 Pu neutron cross sections. Results from the multigroup (MG) calculations further revealed that the group structure of the applied MG library strongly influences the MG bias due to the importance of an appropriate energy resolution of the resonances in higher energy ranges. The application of previously used MG libraries requires new verification for advanced reactor simulation in comparisons with reference continuous-energy calculations. Nuclear data uncertainty analyses of these SFR systems resulted in eigenvalue uncertainties between 1,400 and 1,800 pcm, which are three to four times higher than corresponding uncertainties in light water reactor (LWR) systems. The main contributor to this uncertainty was found to be inelastic scattering on 238 U, which shows an uncertainty of up to 50% in the fast energy range. Other important contributors are the scattering reactions of 56 Fe and 23 Na which have so far not appeared in LWR analysis. Since the largest contribution to the eigenvalue uncertainty of SFR systems is coming from scattering reactions, it is expected that uncertainties in the angular scattering distributions also have a significant impact. Those uncertainties are, however, not available for the majority of nuclides, and the capabilities to determine sensitivities to this data are currently underdeveloped. For two graphite moderated high temperature gas-cooled reactor (HTGR) benchmarks, only the ENDF/BVII. 1 calculations resulted in consistent eigenvalues (k eff ) with the corresponding experimental measurements. Eigenvalue differences of about 1,000 pcm were found between the 2006 ENDF/B-VII.0 data and the 2011 ENDF/B-VII.1 data, primarily due to an updated carbon capture cross section in the thermal energy range in the later ENDF/B release. The ENDF/B-VIII.0 eigenvalue was larger than the ENDF/B-VII.1 eigenvalue by about 300 pcm mainly due to updates in multiple 235 U neutron cross sections, with offsetting updates in the 238 U cross sections. With ENDF/B-VIII.0, graphite can be modeled as perfect crystal or with two different porosities. The choice of the graphite evaluation can have a significant influence of the eigenvalue. For a HTGR benchmark, maximum eigenvalue differences as high as 650 pcm due to different porosities were observed. More detailed studies of the impact of the porosity are necessary while considering that the graphite porosity can vary between the used materials and changes as a function of neutron fluence. xii The uncertainty of the HTGR eigenvalues due to nuclear data uncertainties was found between 500 and 600 pcm, with the top contributor being the neutron multiplicity of 235 U. A gap in the form of missing uncertainties in graphite thermal scattering data, that might have significant impact on HTGR reactors, was identified. This gap is being investigated by the DOE-NE Nuclear Data and Benchmarking Program, as documented in a separate report The fast spectrum molten salt reactor calculations revealed similar comparisons as for the SFR assemblies. The eigenvalue uncertainties were significantly influenced by inelastic scattering on 238 U, while the impact of angular scattering distributions is unknown. For the graphite and zirconium hydride moderated system, eigenvalue uncertainties of up to 700 pcm were observed, requiring in depth analyses of the cross sections and corresponding uncertainties of the included materials. In general, it was observed that the flux spectra of the various molten salt reactor systems show significant differences, even between a fresh state and a depleted state. The choice of the energy group structure of MG calculations is therefore highly relevant; the applicability of previously used MG libraries needs to be verified. Due the unavailability of pin power measurements of advanced reactor systems, pin power calculations with both ENDF/B-VII.1 and VIII.0 data were performed for a light water reactor and compared to corresponding measurements. Both calculations show good agreement with the measurements. A comparison between the ENDF/B-VII.1 and VIII.0 results revealed small differences, mostly in the range of about 0.2%.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗