Search NASA⌕ Search

DOE OSTI · 1506806

Nuclear Data and Benchmarking Program: Nuclear Data Performance Assessment for Advanced Reactors

Abstract

Over the last several Evaluated Nuclear Data File (ENDF)/B releases, many updates have been introduced to the nuclear data libraries that can significantly change computational results. These changes can be particularly important for advanced reactor concepts, which are not as thoroughly investigated as those used in light water reactor (LWR) systems. Therefore, a performance assessment of the ENDF/B libraries using the SCALE 6.2.3 code package was conducted under the auspices of the U.S., Department of Energy Office of Nuclear Energy (DOE-NE). The following systems relevant to the advanced reactor community were chosen as subject for investigation in this report: sodium cooled fast reactor systems, graphite moderated high temperature gas-cooled reactors, and several molten salt reactor models. At first, the similarity of the integral performance of the ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear data libraries caused by compensating errors in important differential data was demonstrated. In calculations for a shipping container of high-assay low enriched uranium, the data of individual isotopes were systematically swapped between the two ENDF/B libraries. An eigenvalue difference of up to 450 pcm was found due to the use of 235 U and 238 U from one library and 1 H and 16 O from the other library. This clearly demonstrates a cross-correlation between reaction data sets of different isotopes within a library that should be reported in the evaluations. For sodium-cooled fast reactor (SFR) fuel assemblies, significant eigenvalue (k inf ) differences (200– 450 pcm) were found between calculations using the 2011 ENDF/B-VII.1 data and 2018 ENDF/B-VIII.0 data. These differences were mainly caused by updates of 238 U and 239 Pu neutron cross sections. Results from the multigroup (MG) calculations further revealed that the group structure of the applied MG library strongly influences the MG bias due to the importance of an appropriate energy resolution of the resonances in higher energy ranges. The application of previously used MG libraries requires new verification for advanced reactor simulation in comparisons with reference continuous-energy calculations. Nuclear data uncertainty analyses of these SFR systems resulted in eigenvalue uncertainties between 1,400 and 1,800 pcm, which are three to four times higher than corresponding uncertainties in light water reactor (LWR) systems. The main contributor to this uncertainty was found to be inelastic scattering on 238 U, which shows an uncertainty of up to 50% in the fast energy range. Other important contributors are the scattering reactions of 56 Fe and 23 Na which have so far not appeared in LWR analysis. Since the largest contribution to the eigenvalue uncertainty of SFR systems is coming from scattering reactions, it is expected that uncertainties in the angular scattering distributions also have a significant impact. Those uncertainties are, however, not available for the majority of nuclides, and the capabilities to determine sensitivities to this data are currently underdeveloped. For two graphite moderated high temperature gas-cooled reactor (HTGR) benchmarks, only the ENDF/BVII. 1 calculations resulted in consistent eigenvalues (k eff ) with the corresponding experimental measurements. Eigenvalue differences of about 1,000 pcm were found between the 2006 ENDF/B-VII.0 data and the 2011 ENDF/B-VII.1 data, primarily due to an updated carbon capture cross section in the thermal energy range in the later ENDF/B release. The ENDF/B-VIII.0 eigenvalue was larger than the ENDF/B-VII.1 eigenvalue by about 300 pcm mainly due to updates in multiple 235 U neutron cross sections, with offsetting updates in the 238 U cross sections. With ENDF/B-VIII.0, graphite can be modeled as perfect crystal or with two different porosities. The choice of the graphite evaluation can have a significant influence of the eigenvalue. For a HTGR benchmark, maximum eigenvalue differences as high as 650 pcm due to different porosities were observed. More detailed studies of the impact of the porosity are necessary while considering that the graphite porosity can vary between the used materials and changes as a function of neutron fluence. xii The uncertainty of the HTGR eigenvalues due to nuclear data uncertainties was found between 500 and 600 pcm, with the top contributor being the neutron multiplicity of 235 U. A gap in the form of missing uncertainties in graphite thermal scattering data, that might have significant impact on HTGR reactors, was identified. This gap is being investigated by the DOE-NE Nuclear Data and Benchmarking Program, as documented in a separate report The fast spectrum molten salt reactor calculations revealed similar comparisons as for the SFR assemblies. The eigenvalue uncertainties were significantly influenced by inelastic scattering on 238 U, while the impact of angular scattering distributions is unknown. For the graphite and zirconium hydride moderated system, eigenvalue uncertainties of up to 700 pcm were observed, requiring in depth analyses of the cross sections and corresponding uncertainties of the included materials. In general, it was observed that the flux spectra of the various molten salt reactor systems show significant differences, even between a fresh state and a depleted state. The choice of the energy group structure of MG calculations is therefore highly relevant; the applicability of previously used MG libraries needs to be verified. Due the unavailability of pin power measurements of advanced reactor systems, pin power calculations with both ENDF/B-VII.1 and VIII.0 data were performed for a light water reactor and compared to corresponding measurements. Both calculations show good agreement with the measurements. A comparison between the ENDF/B-VII.1 and VIII.0 results revealed small differences, mostly in the range of about 0.2%.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bostelmann, Friederike, Holcomb, Andrew M., Clarity, Justin B., Marshall, William B.J., Sobes, Vladimir, Rearden, Bradley T.. 2019-03-01. Nuclear Data and Benchmarking Program: Nuclear Data Performance Assessment for Advanced Reactors. https://doi.org/10.2172/1506806

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Pulsed-Neutron Experiments at the Inherently Safe Subcritical Assembly

The pulsed neutron technique is a powerful, dynamic method to assay the reactivity of a multiplying system. This work presents the novel application of the pulsed neutron technique to the Inherently Safe Subcritical Assembly, an experimental configuration accepted by the International Criticality Safety Benchmark Evaluation Project Handbook. The experiments were replicated with COG11.3, a continuous-energy Monte Carlo code. The pulsed neutron data were analyzed using the Sjöstrand and Gozani area-ratio methods and by extracting the prompt neutron decay constant. Subsequent static k-eigenvalue and 𝛼-eigenvalue simulations were also performed for the same configurations. Neutron detector dead-time effects from the experiments were corrected using the Backwards Extrapolation Method and shown to have a negligible impact on the estimated reactivities. The results highlight that capturing time-dependent effects like delayed neutron precursor buildup are essential to accurately reproduce experimental results. They also highlight the importance of shielding the detectors from generator source neutrons in deeply subcritical configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Machine Learning–Based Condition Monitoring of a Circulating Water System of a Canadian Nuclear Plant

With the need to maintain long-term reliable energy using nuclear power plants, there is an underlying demand to ensure that the maintenance of plant components and systems is also done in an efficient and cost-effective manner. One way to achieve this is by moving from time-based maintenance to condition-based maintenance. The research presented in this paper focuses on applying statistical and machine-learning-based methods to capture anomalies within data for fault detection to further develop into condition monitoring. This paper focuses on system data for a circulating water system (CWS) of a pressurized heavy-water reactor for detecting anomalies. The different methodologies used for detecting and capturing anomalies in the CWS data are matrix profile, density-based spatial clustering of applications with noise (DBSCAN), and support vector machines (SVMs). Matrix profile and DBSCAN are used to distinguish between normal data and anomalous data. This paper presents a hybrid method using DBSCAN and SVM when a portion of the data is used for DBSCAN to generate clusters. This portion of data is then used to train the SVM along with the clusters generated by DBSCAN as output. SVM is then tested on unseen data as a predictive tool, which can work in real time to categorize data points as either normal or anomalous. This paper presents results that show the high accuracies of DBSCAN and SVM in capturing anomalies within the data for a CWS for fault detection. Thus, the maintenance plan would be focused on component condition rather than a time-based schedule by switching to an automated system to identify and predict faults within a CWS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SCALE HTR-PROTEUS Benchmark Model

This dataset contains input and result files of computational simulations of HTR-PROTEUS benchmark with the latest version of SCALE code system. The simulations cover criticality control rod worth calculations as well as sensitivity analysis and uncertainty quantification. Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗