Search NASA⌕ Search

SEARCH · Search NASA

Results for “pixel array detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Continuous full-resolution two-color infrared detector

An apparatus is provided for nanoantenna-enhanced detection of infrared radiation. The apparatus includes one or more detector pixels. A plurality of detector pixels can constitute a focal plane array (FPA). Each detector pixel carries at least a first and a second subpattern of nanoantenna elements, with elements of the second subpattern interpolated between elements of the first subpattern. Each detector pixel also includes separate collection electrodes for collecting photogenerated current from the respective subpatterns.

Goldflam, Michael↗

Mid-infrared detector development for the Origins Space Telescope

Mid-infrared detector arrays operating from 2.8 to 20 μm are baselined in the design of the Origins Space Telescope Mid-Infrared Spectrometer Instrument. This instrument is designed to detect and measure the spectral signatures of gases of biogenic origin in the atmospheres of exoplanets as they transit their host stars. In order to make these detections, the detector array’s pixels need to have high-signal stability when exposed to a constant flux in multiple time-series integration over a typical transit time of a few hours. With the use of a densified pupil spectrometer design, pointing effects can be mitigated because pointing variations do not displace spectra on the detector and each wavelength of light is averaged over a large number of pixels, giving good spectrophotometric stabilities. The current state-of-the-art detector arrays do not achieve these stabilities, although with a feasible development program this level of performance should be achievable. Three detector technologies are under consideration for this development, HgCdTe arrays, Si:As impurity band conduction arrays, and transition edge super-conductor bolometer arrays. We primarily treat the HgCdTe technology development, but also introduce the paths forward for the other two technologies. After a few years-long investigative programs, a down-select will be undertaken to select the flight technology.

Astronomy↗

Downsampling Photodetector Array with Windowing

In a photon counting detector array, each pixel in the array produces an electrical pulse when an incident photon on that pixel is detected. Detection and demodulation of an optical communication signal that modulated the intensity of the optical signal requires counting the number of photon arrivals over a given interval. As the size of photon counting photodetector arrays increases, parallel processing of all the pixels exceeds the resources available in current application-specific integrated circuit (ASIC) and gate array (GA) technology; the desire for a high fill factor in avalanche photodiode (APD) detector arrays also precludes this. Through the use of downsampling and windowing portions of the detector array, the processing is distributed between the ASIC and GA. This allows demodulation of the optical communication signal incident on a large photon counting detector array, as well as providing architecture amenable to algorithmic changes. The detector array readout ASIC functions as a parallel-to-serial converter, serializing the photodetector array output for subsequent processing. Additional downsampling functionality for each pixel is added to this ASIC. Due to the large number of pixels in the array, the readout time of the entire photodetector is greater than the time between photon arrivals; therefore, a downsampling pre-processing step is done in order to increase the time allowed for the readout to occur. Each pixel drives a small counter that is incremented at every detected photon arrival or, equivalently, the charge in a storage capacitor is incremented. At the end of a user-configurable counting period (calculated independently from the ASIC), the counters are sampled and cleared. This downsampled photon count information is then sent one counter word at a time to the GA. For a large array, processing even the downsampled pixel counts exceeds the capabilities of the GA. Windowing of the array, whereby several subsets of pixels are designated for processing, is used to further reduce the computational requirements. The grouping of the designated pixel frame as the photon count information is sent one word at a time to the GA, the aggregation of the pixels in a window can be achieved by selecting only the designated pixel counts from the serial stream of photon counts, thereby obviating the need to store the entire frame of pixel count in the gate array. The pixel count se quence from each window can then be processed, forming lower-rate pixel statistics for each window. By having this processing occur in the GA rather than in the ASIC, future changes to the processing algorithm can be readily implemented. The high-bandwidth requirements of a photon counting array combined with the properties of the optical modulation being detected by the array present a unique problem that has not been addressed by current CCD or CMOS sensor array solutions.

Patawaran, Ferze D.↗

Design, Fabrication, and Testing of a TiN Ti TiN Trilayer KID Array for 3mm CMB Observations

Kinetic inductance detectors (KIDs) are a promising technology for astronomical observations over a wide range of wavelengths in the mm and sub-mm regime. Simple fabrication, in as little as one lithographic layer, and passive frequency-domain multiplexing, with readout of up to 1000 pixels on a single line with a single cold amplifier, make KIDs an attractive solution for high-pixel-count detector arrays. We are developing an array that optimizes KIDs for optical frequencies near 100GHz to expand their usefulness in mm-wave applications, with a particular focus on CMBB-mode measurement efforts in association with the QUBIC telescope. We have designed, fabricated, and tested a 20-pixel prototype array using a simple quasi lumped microstrip design and pulsed DC reactive magnetron-sputtered TiNTiTiN trilayer resonators, optimized for detecting 100GHz (3mm) signals. Here we present a discussion of design considerations for the array, as well as preliminary detector characterization measurements and results from a study of TiN trilayer properties.

passive frequency-domain multiplexing↗

Magnetic Microcalorimeter Gamma Detectors for High-Precision Non-Destructive Analysis

Cryogenic gamma (γ) detectors with operating temperatures of ~0.1 K offer 10× better energy resolution than conventional high-purity germanium detectors that are currently used for non-destructive analysis (NDA) of nuclear materials. This can greatly increase the accuracy of NDA, especially at low-energies where gamma rays often have similar energies and cannot be resolved by Ge detectors. Among the different cryogenic detector types, Magnetic Micro-Calorimeters (MMCs) have the potential of faster count rates and better linearity. High linearity is essential to add spectra from different pixels in detector arrays that are needed for high sensitivity. MMC gamma detectors measure the energy of absorbed gamma rays form the resulting change in magnetization of an erbium-doped gold (Au:Er) sensor. The signal is read out with a SQUID preamplifier and processed digitally with room temperature electronics (see inset figure 2). The objective of this project is to develop ultra-high energy resolution γ-detectors based on magnetic micro-calorimeters (MMCs) for accurate non-destructive isotope analysis (NDA). Since MMCs, like other cryogenic γ-detector technologies with operating temperatures <0.1 K, are intrinsically slow and have to be small for high resolution, special emphasis will be placed on questions that determine sensitivity and the potential for scaling to arrays. Objectives for FY14 were therefore to fabricate an improved version of MMC γ-detectors and test their energy resolution, maximum count rate, readout noise, crosstalk between pixels and linearity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MagMicro with Ultra-High Energy Resolution (FY19 Q3 Progress Report)

The fabrication of the MMC detector arrays involves two photolithographic procedures. The first is to fabricate the Nb magnetization coil and pick-up coils, the SQUID preamplifiers and the associated wiring. This is done on a full 4” Si wafer, which is subsequently diced into ~0.5 cm2 SQUID chips and ~1 cm2 detector chips. The detector chips are then processed separately by depositing and patterning the paramagnetic Ag:Er sensor and support structures and then electroplating the Au absorber. In Q3, we have successfully completed the full wafer processing for the 32-pixel MMC detector arrays, diced the 4” wafer into the smaller chips and tested the individual components. The coils have the required critical current, the heat switches have a critical temperature in the desired range, and the SQUIDs have the required low noise. Unfortunately, the sputter deposition of the paramagnetic Ag:Er sensor failed several times. We spent considerable time to trace the problem to contaminations of the purifier for the Ar sputtering gas that had been exposed to atmosphere for an extended time during an earlier clean room upgrade. We then determined that the purifier is not essential for high-quality Ag:Er sensor films (Fig. 1), and successfully deposited the Ag:Er sensor film on the ~1 cm 2 detector chip.

42 ENGINEERING↗

A 4 x 4 array module of position-sensitive virtual Frisch-grid CdZnTe detectors for gamma-ray imaging spectrometers

Arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors offer an economical approach to making high efficiency and high energy resolution gamma cameras for spectroscopy and imaging of radioactive sources. There are many application areas for such instruments including gamma-rays astronomy, medical and industrial imaging, nonproliferation and nuclear safeguards. We present the test results from a 4x4 array module coupled to the front-end ASIC. The array houses 16 detectors made of 6x6x20 mm 3 CZT crystals. Each crystal is encapsulated inside an ultrathin polyester shell and furnished with four 5-mm-wide charge-sensing pads placed near the anode on each side of the detector. The pad’s signals are used to measure X-Y coordinates while the cathode signals give the interaction depths (Z coordinates). Combined together the signals provide 3D position information of the interaction points which can be used to correct the detector response non-uniformity. This allows developers to use standard grade (unselected) CZT crystals while retaining high spectroscopic performance comparable with that of the H3D pixelated detectors. The array’s design provides flexibility to replace individual detectors and extend their sizes, potentially increasing upwards of 4 cm in height. We started development of position-sensitive VFG detectors several years ago and today this technology has reached a high-maturity level and is ready to use in practical applications.

3D charge-loss correction↗

Characterization of the Ion Beam Focusing in a Mass Spectrometer using an IonCCD™ Detector

A position sensitive pixel-based detector array, referred to as the IonCCDTM, has been employed to characterize the ion optics and ion beam focusing in a custom built mass spectrometer designed for soft and reactive landing of mass-selected ions onto surfaces. The IonCCDTM was placed at several stages along the path of the ion beam to determine the focusing capabilities of the various ion optics which include an electrodynamic ion funnel, two radiofrequency (RF) only collision quadrupoles, a mass resolving quadrupole, a quadrupole bender, and two Einzel lens assemblies. The focusing capabilities of the RF-only collision quadrupoles and Einzel lenses are demonstrated by large decreases in the diameter of the ion beam. In contrast, the mass resolving quadrupole is shown to significantly defocus the mass-selected ion beam resulting in an expansion of the measured ion beam diameter. Combined with SIMION simulations we demonstrate that the IonCCDTM can identify minor errors in the alignment of charged-particle optics that result in erratic trajectories and significant deflections of the ion beam.. This information can be used to improve the design assembly and maintenance of custom-built mass spectrometry instrumentation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

BrachyView, a novel in-body imaging system for HDR prostate brachytherapy: Experimental evaluation

Purpose: This paper presents initial experimental results from a prototype of high dose rate (HDR) BrachyView, a novel in-body source tracking system for HDR brachytherapy based on a multipinhole tungsten collimator and a high resolution pixellated silicon detector array. The probe and its associated position estimation algorithms are validated and a comprehensive evaluation of the accuracy of its position estimation capabilities is presented. Methods: The HDR brachytherapy source is moved through a sequence of positions in a prostate phantom, for various displacements in x, y, and z. For each position, multiple image acquisitions are performed, and source positions are reconstructed. Error estimates in each dimension are calculated at each source position and combined to calculate overall positioning errors. Gafchromic film is used to validate the accuracy of source placement within the phantom. Results: More than 90% of evaluated source positions were estimated with an error of less than one millimeter, with the worst-case error being 1.3 mm. Experimental results were in close agreement with previously published Monte Carlo simulation results. Conclusions: The prototype of HDR BrachyView demonstrates a satisfactory level of accuracy in its source position estimation, and additional improvements are achievable with further refinement of HDR BrachyView’s image processing algorithms.

60 APPLIED LIFE SCIENCES↗

Magnetic Microcalorimeter Gamma Detectors for High-Precision Non-Destructive Analysis, FY14 Extended Annual Report

Cryogenic gamma (γ) detectors with operating temperatures of ~0.1 K or below offer 10× better energy resolution than conventional high-purity germanium detectors that are currently used for non-destructive analysis (NDA) of nuclear materials. This can greatly increase the accuracy of NDA, especially at low-energies where gamma rays often have similar energies and cannot be resolved by Ge detectors. We are developing cryogenic γ–detectors based on metallic magnetic calorimeters (MMCs), which have the potential of higher resolution, faster count rates and better linearity than other cryogenic detector technologies. High linearity is essential to add spectra from different pixels in detector arrays that are needed for high sensitivity. Here we discuss the fabrication of a new generation of MMC γ–detectors in FY2014, and the resulting improvements in energy resolution and linearity of the new design. As an example of the type of NDA that cryogenic detectors enable, we demonstrate the direct detection of Pu-242 emissions with our MMC γ–detectors in the presence of Pu-240, and show that a quantitative NDA analysis agrees with the mass spectrometry

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Evaluation of a Pixelated PSD-capable Scintillator Detector with SiPM Readout

We present the detector response comparison between a 10x10 pixellated array of scintillator read out with Anger logic using four 2" Hamamatsu R7724-100 super bialkali photomultiplier tubes (PMT) and a custom Silicon photomultiplier (SiPM) board consisting of 100 C-series 6x6 mm SiPMs from SensL. An array of these pixellated detectors are currently used in the Neutron Coded Aperture (NCA) imaging system. The energy, timing and pulse shape discrimination response using both readout schemes are presented, along with an analysis of multiple scatter events occurring within the block. An evaluation of the impact of photodetector readout on the overall detection efficiency and imaging accuracy is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The AstroBiology Explorer (ABE) MIDEX Mission Concept: Identifying Organic Molecules in Space

The Astrobiology Explorer (ABE) is a MIDEX mission concept, currently under Concept Phase A study at NASA's Ames Research Center in collaboration with Ball Aerospace & Technologies, Corp., and managed by NASA's Jet Propulsion Laboratory. ABE will conduct infrared spectroscopic observations to address important problems in astrobiology, astrochemistry, and astrophysics. The core observational program would make fundamental scientific progress in understanding the distribution, identity, and evolution of ices and organic matter in dense molecular clouds, young forming stellar systems, stellar outflows, the general diffuse ISM, HII regions, Solar System bodies, and external galaxies. The ABE instrument concept includes a 0.6 m aperture Ritchey-Chretien telescope and three moderate resolution (R = 2000-3000) spectrometers together covering the 2.5-20 micron spectral region. Large format (1024 x 1024 pixel) IR detector arrays will allow each spectrometer to cover an entire octave of spectral range per exposure without any moving parts. The telescope will be cooled below 50 K by a cryogenic dewar shielded by a sunshade. The detectors will be cooled to approx. 7.5 K by a solid hydrogen cryostat. The optimum orbital configuration for achieving the scientific objectives of the ABE mission is a low background, 1 AU Earth driftaway orbit requiring a Delta II launch vehicle. This configuration provides a low thermal background and allows adequate communications bandwidth and good access to the entire sky over the approx. 1.5 year mission lifetime.

Ennico, Kimberly↗

Kepler Instrument Performance: An In-Flight Update

The Kepler Mission is designed to detect the 80 parts per million (ppm) signal from an Earth-Sun equivalent transit. Such precision requires superb instrument stability on time scales up to 2 days and systematic error removal to better than 20 ppm. The sole scientic instrument is the Photometer, a 0.95 m aperture Schmidt telescope that feeds the 94.6 million pixel CCD detector array, which contains both Science and Fine Guidance Sensor (FGS) CCDs. Since Kepler's launch in March 2009, we have been using the commissioning and science operations data to characterize the instrument and monitor its performance. We find that the in-flight detector properties of the focal plane, including bias levels, read noise, gain, linearity, saturation, FGS to Science crosstalk,and video crosstalk between Science CCDs, are essentially unchanged from their pre-launch values. Kepler'sunprecedented sensitivity and stability in space have allowed us to measure both short- and long- term effects from cosmic rays, see interactions of previously known image artifacts with starlight, and uncover several unexpected systematics that affect photometric precision. Based on these results, we expect to attain Kepler's planned photometric precision over 90% of the field of view.

CCD↗

System, apparatus, and method for determining elemental composition using 4D STEM

The present disclosure relates to transmission electron microscopy for evaluation of biological matter. According to an embodiment, the present disclosure further relates to an apparatus for determining the structure and/or elemental composition of a sample using 4D STEM, comprising a direct bombardment detector operating with global shutter readout, processing circuitry configured to acquire images of bright-field disks using either a contiguous array or non-contiguous array of detector pixel elements, correct distortions in the images, align each image of the images based on a centroid of the bright-field disk, calculate a radial profile of the images, normalize the radial profiles by a scaling factor, calculate the rotationally-averaged edge profile of the bright-field disk, and determine elemental composition within the specimen based on the characteristics of the edge profile of the bright-field disk corresponding to each specimen location.

Bammes, Benjamin↗

Nuclear resonant scattering measurements on {sup 57}Fe by multichannel scaling with a 64-pixel silicon avalanche photodiode linear-array detector

We developed a silicon avalanche photodiode (Si-APD) linear-array detector for use in nuclear resonant scattering experiments using synchrotron X-rays. The Si-APD linear array consists of 64 pixels (pixel size: 100 × 200 μm{sup 2}) with a pixel pitch of 150 μm and depletion depth of 10 μm. An ultrafast frontend circuit allows the X-ray detector to obtain a high output rate of >10{sup 7} cps per pixel. High-performance integrated circuits achieve multichannel scaling over 1024 continuous time bins with a 1 ns resolution for each pixel without dead time. The multichannel scaling method enabled us to record a time spectrum of the 14.4 keV nuclear radiation at each pixel with a time resolution of 1.4 ns (FWHM). This method was successfully applied to nuclear forward scattering and nuclear small-angle scattering on {sup 57}Fe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗