Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Effects of backlash and dead band on temperature control of the primary loop of a conceptual nuclear Brayton space powerplant

An analytical study was made of the stability of a closed-loop liquid-lithium temperature control of the primary loop of a conceptual nuclear Brayton space powerplant. The operating point was varied from 20 to 120 percent of design. A describing-function technique was used to evaluate the effects of temperature dead band and control coupling backlash. From the system investigation, it was predicted that a limit cycle will not exist with a temperature dead band, but a limit cycle will not exist when backlash is present. The results compare favorably with a digital computer simulation.

Petrick, E. J.↗

Variable conductance heat pipe technology for precise temperature control of the NASA/DDLT transmitter

The application of variable conductance heat pipe technology for achieving precise temperature control to + or - 0.1 C for a space-based laser diode transmitter is described. Heat pipe theory of operation and test data are presented along with a discussion of its applicability for NASA's Direct Detection Laser Transceiver (DDLT) program. This design for the DDLT transmitter features a reduction in space radiator size and up to 42 percent reduction in prime power requirements.

Vanevenhoven, D. E.↗

Water/glycol temperature control circuit failed in the automatic mode: Apollo 16

An anomaly report concerning failure of the water/glycol temperature control circuit during the Apollo 16 flight is presented. The anomaly is described and diagrams of the system are presented. The malfunction was caused by cracked semiconductor chips in the output silicon-controlled rectifier. Surface contamination in the crack allowed the device to self-gate on and remain on, resulting in a secondary failure of the feedback capacitor.

Source record↗

Auxiliary coil controls temperature of RF induction heater

Auxiliary coil controls the temperature of an RF induction furnace that is powered by a relatively unstable RF generator. Manual or servoed adjustments of the relative position of the auxiliary coil, which is placed in close proximity to the RF coil, changes the looseness of the RF coil and hence the corresponding heating effect of its RF field.

Source record↗

Transparent electrically conducting thin films for spacecraft temperature control applications

Thin transparent films of In2O3 or In2O3 + SnO2 prepared by evaporation or sputtering have been tested for use as surface layers for spacecraft temperature control coatings. The films are intended to prevent nonuniform electric charge buildup on the spacecraft exterior. Film thicknesses of 300 to 500 A were found to be optimal in terms of durability and minimum impact on the solar absorptance and the thermal emissivity of the underlayers. As a verification of their suitability for long-duration space missions, the films were subjected to simulated solar UV plus proton irradiation in a vacuum.

Hass, G.↗

A facility for precise temperature control applications in microgravity

The general design, main components, and operation of the isothermal dendritic growth apparatus (IDGA) designed for microgravity experimentation are described. The four major subsystems of the IDGA are a temperature controlled thermostatic bath capable of milli-kelvin stability, a photographic data collection system, a crystal growth chamber, and a growth detection system to initiate data collection. Some of the specific experiments that could utilize the capabilities of the IDGA are dendritic growth in alloys, monotectic systems, life science experiments, and technological applications.

Glicksman, M. E.↗

Holes help control temperature

Study of passive thermal control for the Solar Terrestrial Subsatellite (STSS) has found that array of "see through" holes substantially improves performance of system. Holes in payload mounting plates allow line of sight radiative heat transfer between hot and cold ends of spacecraft and between mounting plates and ends. Temperature gradients between plates are thereby reduced, as is temperature of each plate. Holes and selected exterior paints and finishes keep payload cool for all orientations and operating modes of STSS.

Chhatpar, C. K.↗

Using a temperature-controlled quartz crystal microbalance in a space equipment cleanroom to monitor molecular contamination

There is a need for continuous monitoring for molecular contamination in clean rooms where spaceflight equipment is assembled, integrated, and tested to insure that contamination budgets are met. The TQCM (temperature-controlled quartz crystal microbalance) can be used to provide both a real time warning and a cumulative measurement of molecular contamination. It has advantages over the other measurement methods such as witness mirrors, NVR (non-volatile residue) plates, and gas analyzers. A comparison of the TQCM sensitivity and ease of operations is made with the other methods. The surface acoustic wave microbalance (SAW), a newly developed instrument similar to TQCM, is considered in the comparison. An example is provided of TQCM use at Goddard Space Flight Center when the Wide Field Planetary Camera 2(WFPC-2) and the Corrective Optics Space Telescope Axial Replacement (COSTAR) were undergoing integrated testing prior to their installation in the Hubble Space Telescope on its first servicing mission. Areas for further investigation are presented.

Mitchell, William J.↗

Pressure-Sensitive System for Gas-Temperature Control

A thermodynamic relation is derived and simplified for use as a temperature-limiting control equation involving measurement of gas temperature before combustion and gas pressures before and after combustion. For critical flow in the turbine nozzles of gas-turbine engines, the control equation is further simplified to require only measurements upstream of the burner. Hypothetical control systems are discussed to illustrate application of the control equations.

Cesaro, Richard S↗

Temperature Control of Avalanche Photodiode Using Thermoelectric Cooler

Avalanche photodiodes (APDS) are quantum optical detectors that are used for visible and near infrared optical detection applications. Although APDs are compact, rugged, and have an internal gain mechanism that is suitable for low light intensity; their responsivity, and therefore their output, is strongly dependent on the device temperature. Thermoelectric coolers (TEC) offers a suitable solution to this problem. A TEC is a solid state cooling device, which can be controlled by changing its current. TECs are compact and rugged, and they can precisely control the temperature to within 0.1 C with more than a 150 C temperature gradient between its surfaces. In this Memorandum, a proportional integral (PI) temperature controller for APDs using a TEC is discussed. The controller is compact and can successfully cool the APD to almost 0 C in an ambient temperature environment of up to 27 C.

Refaat, Tamer F.↗

MEMS Device Being Developed for Active Cooling and Temperature Control

High-capacity cooling options remain limited for many small-scale applications such as microelectronic components, miniature sensors, and microsystems. A microelectromechanical system (MEMS) is currently under development at the NASA Glenn Research Center to meet this need. It uses a thermodynamic cycle to provide cooling or heating directly to a thermally loaded surface. The device can be used strictly in the cooling mode, or it can be switched between cooling and heating modes in milliseconds for precise temperature control. Fabrication and assembly are accomplished by wet etching and wafer bonding techniques routinely used in the semiconductor processing industry. Benefits of the MEMS cooler include scalability to fractions of a millimeter, modularity for increased capacity and staging to low temperatures, simple interfaces and limited failure modes, and minimal induced vibration.

Moran, Matthew E.↗

Heat pipe temperature control utilizing a soluble gas absorption reservior

A new gas-controlled heat pipe design is described which uses a liquid matrix reservior, or sponge, to replace the standard gas reservior. Reservior volume may be reduced by a factor of five to ten for certain gas-liquid combinations, while retaining the same level of temperature control. Experiments with ammonia, butane, and carbon dioxide control gases with methanol working fluid are discussed.

Saaski, E. W.↗

Winter to Spring Transition in Europe 48-45 degrees N: From Temperature Control by Advection to Control by Insolation

As established in previous studies, and analyzed further herein for the years 1988-1998, warm advection from the North Atlantic is the predominant control of the surface-air temperature in northern-latitude Europe in late winter. This thesis is supported by the substantial correlation Cti between the speed of the southwesterly surface winds over the eastern North Atlantic, as quantified by a specific Index Ina, and the 2-meter level temperature Ts over central Europe (48-54 deg N; 5-25 deg E), for January, February and early March. In mid-March and subsequently, the correlation Cti drops drastically (quite often it is negative). The change in the relationship between Ts and Ina marks a transition in the control of the surface-air temperature. As (a) the sun rises higher in the sky, (b) the snows melt (the surface absorptivity can increase by a factor of 3.0), (c) the ocean-surface winds weaken, and (d) the temperature difference between land and ocean (which we analyze) becomes small, absorption of insolation replaces the warm advection as the dominant control of the continental temperature. We define the onset of spring by this transition, which evaluated for the period of our study occurs at pentad 16 (Julian Date 76, that is, March 16). The control by insolation means that the surface is cooler under cloudy conditions than under clear skies. This control produces a much smaller interannual variability of the surface temperature and of the lapse rate than prevailing in winter, when the control is by advection. Regional climatic data would be of greatest value for agriculture and forestry if compiled for well-defined seasons. For continental northern latitudes, analysis presented here of factors controlling the surface temperature appears an appropriate tool for this task.

Otterman, J.↗

Using Thermoelectric Converters for Loop Heat Pipe Operating Temperature Control

This paper describes an experimental study to investigate the effectiveness of using thermoelectric converters (TECs) to control the loop heat pipe (LHP) operating temperature. Tests were conducted on an LHP having two evaporators and two condensers. Each evaporator has its own integral compensation chamber (CC). One side of the TEC is attached to the CC, and the other side is connected to the evaporator through a copper thermal strap. A bi-polar power supply is used to provide the power for the operation of each TEC. The bipolar supply will automatic change the direction of the current to the TEC depending on whether the CC requires heating or cooling in order to maintain its temperature at the desired set point. When cooling the CC, the heat pumped by the TEC plus the power needed to operate the TEC is dissipated to the evaporator, and is ultimately transmitted to the condenser. When heating the CC, the TEC can draw heat from the evaporator to supplement the required control heater power. Test results showed that the TEC could control the LHP operating temperature within h1K of the set point temperature. The control heater power required for TEC operation was also much less than that of using electrical heaters.

Ku, Jentung↗