Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

An inductively powered telemetry system for temperature, EKG, and activity monitoring

An implant telemetry system for the simultaneous monitoring of temperature, activity, and EKG from small animals, such as rats, was designed with the feature that instead of a battery the system is energized by an inductive field. A 250 kHz resonant coil surrounds the cage (30 x 30 x 20 cm) and provides the approximately 100 microns of power required to operate the implant transmitter while allowing the animal unrestrained movement in the cage. The implant can also be battery operated if desired. RF transmission is in the 8-10 MHz band, which allows the use of a simple, essentially single IC chip, receiver.

Fryer, T. B.↗

An inductively powered telemetry system for temperature, EKG, and activity monitoring

An implant telemetry system for the simultaneous monitoring of temperature, activity, and EKG from small animals, such as rats, has recently been designed with the novel feature that instead of a battery the system is energized by an inductive field. A 250 kHz resonant coil surrounds the cage (30 x 30 x 20 cm) and provides the approximately 100 microwatt of power required to operate the implant transmitter while allowing the animal unrestrained movement in the cage. The implant can also be battery operated if desired. RF transmission is in the 8-10 MHz band, which allows the use of a simple, essentially single IC chip, receiver.

Fryer, T. B.↗

Material Testing Device

Small Business Innovation Research (SBIR) contracts led to two commercial instruments and a new subsidiary for Physical Sciences, Inc. (PSI). The FAST system, originally developed for testing the effect of space environment on materials, is now sold commercially for use in aging certification of materials intended for orbital operation. The Optical Temperature Monitor was designed for precise measurement of high temperatures on certain materials to be manufactured in space. The original research was extended to the development of a commercial instrument that measures and controls fuel gas temperatures in industrial boilers. PSI created PSI Environmental Instruments to market the system. The company also offers an Aerospace Measurement Service that has evolved from other SBIR contracts.

Source record↗

Material and Design Optimization of Printed Melt Wire Arrays

Recent work conducted by the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory resulted in the establishment of in-house capabilities for fabricating and testing new advanced manufactured sensors for measuring irradiation temperatures inside a nuclear test reactor. Though current methods of real-time temperature monitoring (e.g., thermocouples) can still be used, the complexity of the feedthroughs and attachments needed for collecting real time measurements greatly increases the experiment-related costs. On the other hand, passive monitoring techniques can be used for collecting post irradiation temperature measurements by inferring reactor temperatures, based on the melting points of well-characterized materials (i.e., standard melt wires). However, challenges have arisen due to the limited space available for including instrumentation in experiments. To resolve this issue, the ASI program expanded its temperature detection capabilities to include advance manufactured melt wires for post-irradiation temperature measurements. These melt wires can determine reactor temperatures while also accommodating space limitations in irradiation experiments. To improve performance reliability and enhance melt wire readability following irradiation, FY-22 efforts have focused on optimizing the materials used in the encapsulation and printed melt wire array. This report details the design and fabrication tasks, along with the subsequent x ray computed tomography (XCT) evaluation process. The melt wire array consisted of indium with a melting point of 157°C, indium/silver (96/4 at%) with a melting point of 219°C, and tin with a melting point of 230°C. The encapsulation disc was made of vanadium due to its low activation properties and radiation resistance when deployed in nuclear reactors. Additionally, the melt wire design consisted of a ceramic sublayer (alumina disc) to further enhance the XCT post melting images of the printed melt wires. However, when sealing the vanadium container, all three melt wires melted, reflecting the temperature limitations that must be considered when employing metal containers in the sealing process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision and radiosonde validation of satellite gridpoint temperature anomalies. I - MSU channel 2. II - A tropospheric retrieval and trends during 1979-90

Monthly 2.5-deg gridpoint anomalies in the Tiros-N satellite series Microwave Sounding Unit channel 2 brightness temperatures during 1979-1988 are evaluated with multiple satellites and radiosonde data for their climate temperature monitoring capability. The MSU anomalies are computed about a 10-yr mean annual cycle at each gridpoint, with the MSUs intercalibrated to a common arbitrary level. The monthly gridpoint anomaly agreement between concurrently operating satellites reveals single-satellite precision generally better than 0.07 C in the tropics and better than 0.15 C at higher latitudes. The removal from channel 2 of the temperature influence above the 30-kPa level is addressed, providing a sharper and thus potentially more useful weighting function for monitoring lower tropospheric temperatures.

Spencer, Roy W.↗

Body/bone-marrow differential-temperature sensor

Differential-temperature sensor developed to compare bone-marrow and body temperature in leukemia patients uses single stable amplifier to monitor temperature difference recorded by thermocouples. Errors are reduced by referencing temperatures to each other, not to separate calibration points.

Anselmo, V. J.↗

Gas-Temperature Measurement With Minimal Perturbation

Method for measuring temperature of hot turbulent gases uses three heatflux calorimeters. One calorimeter measures radiative heat flux, while other two measure total heat flux (convective and radiative), at two different temperatures. Adapted for commercial uses in such operations as monitoring temperatures of flue gases, piped liquid or gaseous products, internal-combustion or jet engine exhausts.

Fu, T. S.↗

Application of fuzzy logic to the control of wind tunnel settling chamber temperature

The application of Fuzzy Logic Controllers (FLC's) to the control of nonlinear processes, typically controlled by a human operator, is a topic of much study. Recent application of a microprocessor-based FLC to the control of temperature processes in several wind tunnels has proven to be very successful. The control of temperature processes in the wind tunnels requires the ability to monitor temperature feedback from several points and to accommodate varying operating conditions in the wind tunnels. The FLC has an intuitive and easily configurable structure which incorporates the flexibility required to have such an ability. The design and implementation of the FLC is presented along with process data from the wind tunnels under automatic control.

Gwaltney, David A.↗

Air and Water Temperature Relationship and Growth of Hyacinth and Primrose

Temperature is a primary determining factor for plant growth and development so providing an appropriate temperature input is critically important for developing growth models. The Delta Region Areawide Aquatic Weed Project (DRAAWP), a USDA (US Dept. of Agriculture)-sponsored area-wide project including NASA Ames Research Center and State of California Department of Boating and Waterways, uses modeling to assess invasive aquatic plant impacts on ecosystem services in the Delta. Availability of continuous records for monitored temperature is limited and particularly in the case of water temperature the distribution of monitoring is inadequate. This work quantitatively defines the influence of air and water temperature in determining dominant growth rate processes for important floating aquatic invasive plants in the Delta. Since these plants function with portions submerged and above water we wanted to understand the relationship between root zone and shoot zone temperature and ability to use a single temperature inputs in DRAAWP models. Water Hyacinth and Primrose were gown in multiple controlled environment chamber studies with various combinations of root zone and shoot zone temperatures. Long-term growth studies provided integrated response of biomass accumulation and distribution within the canopy. Short-term gas exchange studies provide a time scale for responsiveness to temperature and a short-term study approach to evaluate temperature responses at various stages of canopy development.

Hyacinth↗

Flight Tests on a Fiber Optic Temperature Sensor

For aircraft engine control, one key parameter to detect on an airplane is the exhaust gas temperature (EGT). Presently, thermocouples are used to perform this measurement. These electrical sensors perform adequately; however, fully utilizing the benefits of optical sensors requires replacing electrical architectures with optical architectures. Part of this requires replacing electrical sensors with optical sensors, such as the EGT sensor chosen for these tests. The objective of the development and testing of this prototype sensor system was to determine the feasibility of operating an optical sensor in a hostile aircraft environment. The fiber optic sensor system was developed to measure temperatures from 20C to 600C in an aircraft environment and was utilized to monitor the EGT of an OV-10D aircraft engine. The sensor has successfully flown over 50 hours and proven to be immune to surface deterioration of the optical element (located inside the sensor head) and able to withstand and operate in normal and sustained severe flight conditions where forces on the airplane exceeded 4 g's. Potential commercial uses for this sensor include monitoring temperature for aeropropulsion system control, military vehicle and naval engine control, conventional and nuclear power plant monitoring and industrial plan monitoring where EMI issues are critical.

Tuma, Margaret L.↗

Development of an electronically-scanned pressure module for operation at cryogenic temperatures

Pressure and temperature characteristics were measured for a number of multichannel electronically scanned pressure sensors. The tests were made on commercially available units designed to operate in a controlled temperature environment. Measurements of zero shift, sensitivity, and nonlinearity for each transducer were taken over a temperature range from 100 K to 340 K using a computer controlled data acquisition system. The units tested failed to meet accuracy specifications over the complete temperature range, which was expected. However, the sensors showed acceptable and predictable behavior over the temperature range from approximately -40 C (233 K) to 70 C (343 K). It was determined that a combination of local heating and accurate temperature monitoring can result in a device that can be compensated for temperature as well as its other physical properties. The design of a prototype for operation in a cryogenic environment is proposed, and a method for compensation is developed.

Johnson, Preston B.↗

Fast wide-field upconversion luminescence lifetime thermometry enabled by single-shot compressed ultrahigh-speed imaging

Photoluminescence lifetime imaging of upconverting nanoparticles is increasingly featured in recent progress in optical thermometry. Despite remarkable advances in photoluminescent temperature indicators, existing optical instruments lack the ability of wide-field photoluminescence lifetime imaging in real time, thus falling short in dynamic temperature mapping. Here, we report video-rate upconversion temperature sensing in wide field using single-shot photoluminescence lifetime imaging thermometry (SPLIT). Developed from a compressed-sensing ultrahigh-speed imaging paradigm, SPLIT first records wide-field luminescence intensity decay compressively in two views in a single exposure. Then, an algorithm, built upon the plug-and-play alternating direction method of multipliers, is used to reconstruct the video, from which the extracted lifetime distribution is converted to a temperature map. Using the core/shell NaGdF 4 :Er 3+ ,Yb 3+ /NaGdF 4 upconverting nanoparticles as the lifetime-based temperature indicators, we apply SPLIT in longitudinal wide-field temperature monitoring beneath a thin scattering medium. SPLIT also enables video-rate temperature mapping of a moving biological sample at single-cell resolution.

47 OTHER INSTRUMENTATION↗

AOI [1]: Passive Wireless Sensor Systems Fabricated by Direct-Writing for Temperature and Health Monitoring of Energy Systems in Harsh-Environments (Final Report)

Researchers at West Virginia University (WVU) propose to demonstrate a wireless, high-temperature sensor system for monitoring the temperature and health of energy-system components. The active sensor and electronics for wireless communication will be composed entirely of an electroceramic materials (conductive ceramics) which are capable of withstanding the harsh-environments required for fossil energy-based technologies. This work will focus primarily on the fabrication and testing of temperature (thermocouples and thermistors) and health (strain/stress and crack propagation sensors) that function at extreme temperatures (up to 700-1700ºC). The electronics will accompany the high-temperature sensor, which will include a passive wireless communication circuit that allows the transmission of the data based on the LCR resonance principle to a near-by reader antenna. This passive transmission of data will reduce the need for interconnect wires near the active, and possibly rotating, energy-system component. The research will include process development to permit the 2D/3D direct-writing of the entire sensor and communication circuit onto the energy-system component. The direct-writing will be facilitated by using silicon-based polymer-derived precursors to form the high-temperature, stable electroceramic compositions. In addition, methods for direct-writing the circuit onto a fugitive carrier substrate will be completed, which will permit a “peel-and-stick”-like transfer of the sensor circuit to the energy-system component. This feature will allow the economical and precise placement of the sensor circuit onto components of various shapes and locations, without altering the geometry and active features of the manufactured component, or the removal (or decommissioning) of the component for installation. The proposed work will be directed at the following areas: 1) Investigation of phase formation, sintering/grain growth, and electrical properties of polymer-derived electroceramic composites; 2) Definition of processes to direct-write through ink-jet and robo-casting the polymer-derived electroceramic composites onto oxide and polymer surfaces; 3) Development of methods to form monolithic "peel-and-stick" preforms that will efficiently transfer the sensor circuit to ceramic surfaces after thermal treatment; 4) Design of passive wireless LCR circuits and receiver (reader) antennas for communication and testing at high temperatures; 5) Investigation of the passive wireless sensor system developed (and method of transferring sensor system) for temperature and stress/strain measurements on a SOFC repeat unit and a singular gas turbine blade prototype as example applications.

01 COAL, LIGNITE, AND PEAT↗

Optimizing ensemble NV − spin properties of fluorescent diamond microparticles by systematic low pressure high temperature annealing

Low pressure high temperature annealing is a means for driving nitrogen and defect diffusion in diamond to reduce internal lattice damage without the need for technically complicated high-pressure cells. Herein, we perform a systematic time (5, 15, and 30 min) and temperature (1200 °C–1800 °C) study of effects of low-pressure high temperature annealing on photoluminescence, spin concentrations, and spin relaxation properties of NV centers in ca. 3 μm synthetic type 1b diamond particles. Annealing in the temperature range of ca. 1400 °C–1700 °C for even 5 min leads to a higher optically detected magnetic resonance contrast as compared to standard annealing at 900 °C for 2 h. Particles annealed at 1700 °C for 5 min exhibit a contrast close to about 13% as compared to about 9% for those annealed at 900 °C for 2 h. A reduction in the zero-field splitting strain parameter from E ≈ 4.5 MHz to ≈ 2.5 MHz and spectral linewidth from Δν ≈ 7 MHz to ≈ 4 MHz are observed even after 5 min annealing at 1700 °C. Improvements in these spectral parameters resulted in a roughly 2-fold reduction in the noise level of temperature monitoring experiment utilizing an ensemble of NV centers in the particles. Annealing in the temperature range of 1600 °C for 15 or 30 min or 1700 °C for 5 min resulted in NV T 1 relaxation times approaching ca. 5 ms typically observed for bulk diamond. Quantitative electron paramagnetic resonance (EPR) allowed for estimations of thermal activation energies of paramagnetic center annihilation. Monitoring the primary defect concentration (P1 and other defects with half integer spins) and utilizing second order kinetic modeling, an activation energy of 3.63 ± 0.28 eV was estimated. Alternatively, using the NV half field EPR signal and first order kinetic modeling, a similar activation energy 3.89 ± 0.29 eV was estimated.

NV centers↗

Rocket temperature soundings

The purpose was to provide rocket-borne measurements of temperature and wind. These data are used to: obtain a better understanding of the processes that control the chemical and dynamic behavior of the stratospheric region; monitor temperature trends and detect changes; verify and monitor remote measurements (ground- and satellite-based); and provide density measurements for large space vehicle operations.

Schmidlin, Francis J.↗

Precision and Radiosonde Validation of Satellite Gridpoint Temperature Anomalies. Part I; MSU Channel 2: MSU Channel 2 - Pt. 1

In Part 1 of this study, monthly 2.5 deg. gridpoint anomalies in the TIROS-N (Television and Infrared Operational Satellite-N) series Microwave Sounding Unit (MSU) channel 2 brightness temperatures during 1979-88 are evaluated with multiple satellites and radiosonde data for their climate temperature monitoring capability. The MSU anomalies we computed about a 10-year mean annual cycle at each grid point, with the MSUs intercalibrated to a common arbitrary level. The intercalibrations remove relative biases between instruments of up to several tenths of a degree celsius. The monthly gridpoint anomaly agreement between concurrently operating satellites reveals single-satellite precision on generally better than 0.07 C in the tropics and better than 0.15 C at higher latitudes. Monthly anomalies in radiosonde channel 2 brightness temperatures computed with the radiative transfer equation compare very closely to the MSU measured anomalies in all climate zones, with correlations generally from 0.94 to 0.98 and standard errors of 0.15 C in the tropics to 0.30 C at high latitudes. Simplification of these radiative transfer calculations to a static weighting profile applied to the radiosonde temperature profile leads to an average degradation of only 0.02 deg. in the monthly skill. In terms of a more traditionally measured quantity, the MSU channel 2 anomalies match best with either the radiosonde 100-20-kPa or 100-15-kPa layer anomalies. No significant spurious trends were found in the 10-yr satellite dataset compared to the radiosondes that would indicate a calibration drift in either system. Thus, sequentially launched, overlapping passive microwave radiometers provide a useful system for monitoring intraseasonal to interannual climate anomalies and offer hope for monitoring of interdecadal trends from space. The Appendix includes previously unpublished details of the MSU gridpoint anomaly dataset construction. Part II of this study addresses the removal from channel 2 of the temperature influence above the 30-kPa level, providing a sharper and thus potentially more useful weighting function for monitoring lower tropospheric temperatures.

Spencer, Roy W.↗