Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

THERMAL ANALYSIS AND DESIGN OF SELF-HEATING MOLDS USING LARGE-SCALE ADDITIVE MANUFACTURING FOR OUT-OF-AUTOCLAVE APPLICATIONS

Autoclave processing is a commonly used state-of-the-art fiber-reinforced composite manufacturing technology, albeit high capital cost, long cycle times and high energy consumption. Alternatively, out-of-autoclave processing reduces the initial and operating costs while producing composite structures with similar quality as that of autoclave parts. Additive Manufacturing (AM) the scaled-up molds for out-of-autoclave process using carbon fiber (CF) reinforced composite offers design flexibility, enhanced mechanical, and thermal properties in addition to reduction in weight and cost. However, heating of these molds using an oven is still expensive and necessitates an energy-efficient heating process. In this study, resistive heating through heating elements embedded within fiber reinforced composite molds is used as an efficient heating mechanism. The goal is to design wire embeddings and determine the optimal heat flux density to achieve a target uniform temperature of 1000C across the mold surface. To this end, numerical analyses were performed to evaluate the temperature distribution across the composite mold surface for a given wire placement and mold configuration. Constant thermal properties of the 20 wt.% short CF reinforced acrylonitrile butadiene styrene (ABS) were used in the thermal analysis. Time taken to reach the steady state temperature was also estimated. Design guidelines for wire embeddings were included to enable efficient manufacturing of fiber-reinforced composites through out-of-autoclave molds.

Pokkalla, Deepak↗

Pool Fire Analysis Methodology for Assessing Damage to Waste Containers

This document provides guidelines, whereby the physical parameters associated with postulated flammable/combustible liquid pool fires are determined (thermal analysis) in order to estimate the number of waste containers impacted. Pool fire damage to waste containers may occur due to a container being fully engulfed (within the periphery of the pool), partially engulfed, or within the critical heat flux distance. The methodology described here for estimating the size of the pool fire is developed using spill characteristics outlined in Chapter 65 of the SFPE Handbook (Ref. 7) and testing done by Hansen (Ref. 25). For exposures, the critical flux height is determined using the detailed method of Shokri and Beyler (Ref. 8) from the flame height, calculated as described by Heskestad (Ref. 7) and the average black body emissive power, determined using the method of Shokri and Beyler (Ref. 8). Three types of liquid pool fires should be considered; unconfined crash/instantaneous spill fires, unconfined continuously flowing (also called metered leak) spill fires, and confined spill fires. All fuel sources should be considered consistent with the facility Fire Hazard Analysis (FHA). However, the most likely liquid fuel sources present in TRU waste facilities are those present on TRU waste handling vehicles (forklifts, pallet movers, transport trucks, etc.). This method can also be used for assessing damage to items other than waste containers or other methods of analysis may be used with appropriate justification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A review of reaction rates and thermodynamic and transport properties for the 11-species air model for chemical and thermal nonequilibrium calculations to 30000 K

Reaction rate coefficients and thermodynamic and transport properties are provided for the 11-species air model which can be used for analyzing flows in chemical and thermal nonequilibrium. Such flows will likely occur around currently planned and future hypersonic vehicles. Guidelines for determining the state of the surrounding environment are provided. Approximate and more exact formulas are provided for computing the properties of partially ionized air mixtures in such environments.

Gupta, Roop N.↗

Vacuum stability requirements of polymeric material for spacecraft application

The purpose of this document is to establish outgassing requirements and test guidelines for polymeric materials used in the space thermal/vacuum environment around sensitive optical or thermal control surfaces. The scope of this document covers the control of polymeric materials used near or adjacent to optical or thermal control surfaces that are exposed to the thermal/vacuum environment of space. This document establishes the requirements and defines the test method to evaluate polymeric materials used in the vicinity of these surfaces in space applications.

Craig, J. W.↗

Fabrication And Evaluation Of Sic/Sic Tubes With Various Fiber Architectures

SiC/SiC composites are excellent material candidates for high temperature applications where the performance requirements are high strength, high creep-rupture resistance, high environmental durability, and high thermal conductivity. In the past, the NASA UEET program has demonstrated fabrication of high-performance SiC/SiC flat panels reinforced by Sylramic-iBN SiC fibers. Currently NASA UEET is scaling up this SiC/SiC system by fabrication of more complex shaped components using the same fiber type. This paper reports the effects of various fiber architectures on the processing, mechanical, and durability behavior of small-diameter 0.5" ID SiC/SiC tubes, which are potential sub-elements for leading edges and cooling channels in turbine vanes and blades. Nine different fiber architectures were utilized for construction of seamless tube preforms, from simple 2D jelly-rolling to complex braiding, pin-weaving, filament-winding and 3D orthogonal weaving with approximately 5% fibers in the thru-thickness direction. Using the BN interphase and Sic matrix processing steps established for the flat panels, SiC/SiC tubes were fabricated with wall thicknesses of approximately 60 mils and total fiber fractions of approximately 35%. The "D" split ring tests for hoop tensile properties, micro-structural examinations for relationship between fiber architecture formation and matrix infiltration, and the low-pressure burner rig tests for the high temperature durability under thru-thickness thermal gradient were conducted. The better matrix infiltration and higher hoop strength were achieved using the tri-axial braided and the three-float pin woven SiC/SiC tubes. In general, it needs not only higher hoop direction fibers but also axial direction fibers for the higher hoop strength and the better infiltration, respectively. These results are analyzed to offer general guidelines for selecting fiber pre-form architectures and SiC/SiC processes that maximize tube hoop strength, thru-thickness thermal conductivity, and burner-rig durability under a high thermal gradient.

Yun, H. M.↗

Metal additively manufactured wavy fin cold-plate architecture for improved thermal-hydraulic performance

Rapid growth in artificial intelligence and data center workloads demands high-performance liquid cooling to manage increasing chip power. This study presents two metal-additive-manufactured cold plates with sinusoidal fins, constant-amplitude wavy fins and linearly variable-amplitude wavy fins and compares them against metal-additive-manufactured straight fins using experiments conducted at 1 kW heat dissipation as well as high-fidelity 3D conjugate computational fluid dynamic simulations. The cold plates were printed in AlSi10Mg material and underwent design using a Python-automated workflow prior to manufacture and testing. The experiments show that wavy fins reduce the normalized thermal resistance by 35 to 45 % at water flow rates from 1 to 4 LPM. At a fixed 20 kPa pressure drop, the variable-waviness design lowered peak surface temperature by 9 °C and thermal resistance by 51 %, while edge-channel maldistribution in the constant wavy fin design limited gains. A thermal resistance breakdown revealed that 55–63 % of the total thermal resistance in wavy designs comes from base heat conduction, 27–33 % from fin heat conduction, and 9–13 % from fin heat convection, indicating the need to address conduction bottlenecks. Parametric sweeps identify a 3 mm fin pitch as optimal, and that horizontal inlet/outlet manifolds further reduce pressure drop by 30–60 % and thermal resistance by 9–16 % relative to vertical inlet-outlet manifolds. The results yield comprehensive guidelines for fin geometry, manifold alignment, material selection and additive-manufacturing constraints to realize high-performance liquid-cooled cold plates for power-dense electronics.

3d printing↗

Preliminary Sensitivity Analysis for Sensors Impacts on Building Control Performance

This report describes the preliminary sensitivity analysis for sensor impacts on building control performance through the US Department of Energy’s Oak Ridge National Laboratory’s Flexible Research Platform (FRP-2) building. The rooftop unit system provides cooling and heating to the building. The main heating coil is a gas heating coil. Each zone is served by a variable air volume box with an electricity reheat coil. The rooftop unit and variable air volume box controls adopted the practical control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. For sensors, the incipient (time-changing) sensor errors, including bias sensor error and precision sensor error, are the inputs of interest. The outputs are energy consumption and thermal comfort (e.g., the predicted percentage of dissatisfied occupants). The large-scale simulation (3,600 cases) was conducted on a cloud platform by integrating sensor errors and ASHRAE Guideline 36 control sequences into an emulator based on the EnergyPlus simulation program with Python energy management system feature. The surrogate models were developed based on cloud simulation results. The uncertainty analysis showed that the sensor errors substantially affect building energy consumption and thermal comfort. The sensitivity analysis shows a ranking of sensor error impacts for each interested output item (e.g., cooling energy, reheat coil heating energy, predicted percentage of dissatisfied occupants). In FY 2022, sensor locations, types, and costs will be evaluated. The field test in Oak Ridge National Laboratory’s Flexible Research Platform building regarding sensor impacts will also be performed. Finally, a comparative analysis will be conducted based on the field test results and emulator results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simplified micromechanical equations for thermal residual stress analysis of coated fiber composites

The fabrication of metal matrix composites poses unique problems to the materials engineer. The large thermal expansion coefficient (CTE) mismatch between the fiber and matrix leads to high tensile residual stresses at the fiber/matrix (F/M) interface which could lead to premature matrix cracking during cooldown. Fiber coatings could be used to reduce thermal residual stresses. A simple closed form analysis, based on a three phase composite cylinder model, was developed to calculate thermal residual stresses in a fiber/interphase/matrix system. Parametric studies showed that the tensile thermal residual stresses at the F/M interface were very sensitive to the CTE and thickness of the interphase layer. The modulus of the layer had only a moderate effect on tensile residual stresses. For a silicon carbide titanium aluminide composite, the tangential stresses were 20 to 30 pct. larger than the axial stresses, over a wide range of interphase layer properties, indicating a tendency to form radial matrix cracks during cooldown. Guidelines for the selection of appropriate material properties of the fiber coating were also derived in order to minimize thermal residual stresses in the matrix during fabrication.

Naik, R. A.↗

System Design for a Nuclear Electric Spacecraft Utilizing Out-of-core Thermionic Conversion

Basic guidelines are presented for a nuclear space power system which utilizes heat pipes to transport thermal power from a fast nuclear reactor to an out of core thermionic converter array. Design parameters are discussed for the nuclear reactor, heat pipes, thermionic converters, shields (neutron and gamma), waste heat rejection systems, and the electrical bus bar-cable system required to transport the high current/low voltage power to the processing equipment. Dimensions are compatible with shuttle payload bay constraints.

Estabrook, W. C.↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Engineering handbook on the atmospheric environmental guidelines for use in wind turbine generator development

The guidelines are given in the form of design criteria relative to wind speed, wind shear, turbulence, wind direction, ice and snow loading, and other climatological parameters which include rain, hail, thermal effects, abrasive and corrosive effects, and humidity. This report is a presentation of design criteria in an engineering format which can be directly input to wind turbine generator design computations. Guidelines are also provided for developing specialized wind turbine generators or for designing wind turbine generators which are to be used in a special region of the United States.

Frost, W.↗

Pressure control and analysis report: Hydrogen Thermal Test Article (HTTA)

Tasks accomplished during the HTTA Program study period included: (1) performance of a literature review to provide system guidelines; (2) development of analytical procedures needed to predict system performance; (3) design and analysis of the HTTA pressurization system considering (a) future utilization of results in the design of a spacecraft maneuvering system propellant package, (b) ease of control and operation, (c) system safety, and (d) hardware cost; and (4) making conclusions and recommendations for systems design.

Source record↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Continuous soil temperature measurements from 2019-10-4 to 2020-10-4, Teller road Mile 27, Seward Peninsula, Alaska

The dataset contains depth-resolved soil temperature measured at 45 discrete locations in a watershed located along the Nome-Teller road at Mile 27 in Seward Peninsula, Alaska. The dataset was generated to understand the local heterogeneity of soil thermal dynamics and their controls in a discontinuous permafrost region. At each location, temperatures were measured by a distributed temperature profiling probe designed based on Dafflon et al (2022). The dataset includes a description of the probe locations in the "Probe_locations.csv" file and the 45 data files (Soil_temperatures_*.csv). Metadata files include data descriptions (_dd.csv) for tabular data. All included files are listed and described in NGA513_flmd.csv.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

SPRUCE Bud Cold Hardiness of Trees and Shrubs in Experimental Plots, Marcell Experimental Forest, Minnesota, 2021-2025

This dataset contains bud cold hardiness measurements from the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experimental site (Hanson et al, 2017) within the Marcell Experimental Forest in northern Minnesota, USA. Cold hardiness was quantified as the temperature at which low temperature exotherms (LTEs) were identified (i.e., the temperature at which supercooled water within a bud freezes) measured by differential thermal analysis (DTA). Buds were sampled at semi-regular intervals from September 2021 through May 2025 (2021-09-25 to 2025-05-21) across four seasons (2021-2022 through 2024-2025) for four co-occurring boreal peatland tree and shrub species: Picea mariana (PIMA), Larix laricina (LALA), Rhododendron groenlandicum (RHGR), and Chamaedaphne calyculata (CHCA). Samples were collected across the experiment's warming gradient (ambient to +9 degrees Celsius (C)) and pooled by species within each enclosure. These data were used to assess the species- and season-specific effects of experimental warming on cold hardiness and cold damage risk in boreal peatland vegetation (Campos-Arguedas et al, accepted). This dataset contains one data file in comma-separate values (*.csv) format. Additional metadata are provided: a data dictionary and a file-level metadata file in comma-separate values (*.csv) format and a user guide in PDF (*.pdf) format.

Chamaedaphne calyculata↗

Probabilistic estimation of depth-resolved profiles of soil thermal diffusivity from temperature time series: Supporting Data

This dataset consists of soil temperature time series that were used to estimate soil thermal diffusivity and its uncertainty trough the probabilistic modelling approach developed and presented in the article named "Probabilistic estimation of depth-resolved profiles of soil thermal diffusivity from temperature time series" and published in Earth Surface Dynamics. There are two compressed (.zip) files that contains synthetic (Synthetic_soiltemp_Teller.zip) and field (Field_soiltemp_Teller.zip) data. There is one MATLAB file that requires MATLAB to execute but any text editor can open it. The Synthetic_soiltemp_Teller.zip file includes 5 comma-delimited data files (.csv) each of which contains soil temperature time series generated through forward modeling (i.e., heat-conduction process in a heterogeneous medium using an explicit finite difference method) to mimic various types of temperature gradients, trend and fluctuations. These synthetic soil temperatures were used to investigate the impact of different environmental conditions on the uncertainty of thermal diffusivity estimates. The Field_soiltemp_Teller.zip file contains 28 comma-delimited data files (.csv) out of which (a) 27 files includes soil temperature time series recorded from 27 temperature probes located in a site along Teller Road about 40 km northwest of Nome, Alaska (64.72°N, 165.94°W), (b) one includes the name and coordinates of the 27 probes. These field soil temperatures were used to infer soil thermal diffusivity at numerous locations and depths in a discontinuous permafrost environment, and to evaluate the links between the estimated soil thermal diffusivity values and soil physical properties. The comma-delimited data files (.csv) of the synthetic and field soil temperature time series includes date and time (UTC) in the first column and soil temperature from 5 cm below the ground surface to 1.05 m depth (with 5 or 10 cm spacing between sensors) in the other columns. The measurements were acquired every 15 minutes. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Vegetation Warming Experiment: Environmental Conditions, Utqiagvik (Barrow), Alaska, 2018

Environmental conditions measured in five warming chambers and paired ambient control plots located on the Barrow Environmental Observatory (BEO), Utqiagvik, Alaska from 16 June - 24 September, 2018. These data were recorded in support of the Zero Power Warming (ZPW) vegetation warming experiment, a series of single season vegetation warming treatments conducted over four years from 2017-2021 (no experiment in 2020). Air temperature and humidity, infrared surface (canopy) temperature, soil temperature, soil moisture, NDVI (normalized difference vegetation index), PRI (photochemical reflectance index), solar radiation and chamber venting were recorded in each chamber at 1 minute intervals. Ambient air temperature, humidity, solar radiation and uplooking PRI and NDVI were measured at a centrally located meteorology station. Vapor pressure deficit (VPD) was calculated and included in the final processed data products. Data has undergone full QA/QC and is presented as 1 minute data, and hourly and daily aggregate data products. This data package includes unprocessed raw data (*.dat files), processed data (*.csv) and metadata including a full description of sensors, calculations and processing (*.csv, *.pdf). See related NGEE-Arctic "Vegetation Warming Experiment" data packages for leaf-level gas exchange and other leaf trait data; chamber, plot and landscape phenocamera images; thaw depth, and GPS locations of chambers and ambient plots.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Vegetation Warming Experiment: Environmental conditions, Utqiagvik (Barrow), Alaska, 2019

Environmental conditions measured in five warming chambers and paired ambient control plots located on the Barrow Environmental Observatory (BEO), Utqiagvik, Alaska from 19 June – 25 September, 2019. These data were recorded in support of the Zero Power Warming (ZPW) vegetation warming experiment, a series of single season vegetation warming treatments conducted over four years from 2017–2021 (no experiment in 2020). Air temperature and humidity, infrared surface (canopy) temperature, soil temperature, soil moisture, NDVI (normalized difference vegetation index), PRI (photochemical reflectance index), solar radiation and chamber venting were recorded in each chamber at 1 minute intervals. Ambient air temperature, humidity, solar radiation and uplooking PRI and NDVI were measured at a centrally located meteorology station. Vapor pressure deficit (VPD) was calculated and included in the final processed data products. Data has undergone full QA/QC and is presented as 1 minute data, and hourly and daily aggregate data products. This data package includes unprocessed raw data (*.dat files), processed data (*.csv) and metadata including a full description of sensors, calculations and processing (*.csv, *.pdf). See related NGEE-Arctic "Vegetation Warming Experiment" data packages for leaf-level gas exchange and other leaf trait data; chamber, plot and landscape phenocamera images; thaw depth, and GPS locations of chambers and ambient plots.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗