Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Point Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Solid-State Joining of Magnesium Sheet to High-Strength Steel

Increasing the use of lightweight materials and implementing enabling manufacturing technologies are the two primary paths toward automotive weight reduction. In many situations, the ability to substitute light weight material requires a need to attach and join light weight material to existing steel substructures requiring dissimilar joining technologies. Dissimilar joining methods currently available in cost range for high volume automotive manufacturing face multiple challenges. The problem is exacerbated in the case of Magnesium alloy to steel joints because of their highly dissimilar nature and lack of mutual miscibility. Additionally, Magnesium’s poor room temperature ductility complicates the use of point fastening technologies. Two emerging solid-state joining technologies Friction Stir assisted Scribe welding (FaST) and Ultrasonic Welding (USW) that employ large amount of plastic deformation at the interface were used to investigate, develop, and understand dissimilar joints between Magnesium Alloy to DP590 Steel. Various process responses including interface temperatures, process forces, strain fields were captured during the development of the welding process. Variety of welded samples were tested and characterized to understand the relationship between welding conditions and joints microstructure and mechanical properties.

36 MATERIALS SCIENCE↗

Structural, electronic and thermodynamic properties of R{sub 3}ZnH{sub 5} (R=K, Rb, Cs): A first-principle calculation

R{sub 3}ZnH{sub 5} (R=K, Rb, Cs) series have been investigated with respect to the crystal structure, electronic and thermodynamic properties using first-principle methods based on density functional theory with generalized gradient approximation. The optimized structures and atomic coordinates are in good agreement with the experimental data. The strong covalent interactions are obtained between Zn and H atoms in the 18-electron [ZnH{sub 4}]{sup 2-} complex, while an ionic interaction is found between [ZnH{sub 4}]{sup 2-} and R atom. The formation enthalpies show that the formations of R{sub 3}ZnH{sub 5} hydrides are all exothermic at 298 K. The vibration free energies of R{sub 3}ZnH{sub 5} show that the thermodynamic stabilities of R{sub 3}ZnH{sub 5} hydrides decrease with the increasing diameter of R atom. Two possible decomposition reactions of R{sub 3}ZnH{sub 5} series have been suggested in our work. One (reaction one) is that R{sub 3}ZnH{sub 5} hydrides decomposes to elements directly, and the other (reaction two) is that R{sub 3}ZnH{sub 5} hydrides decomposes to RH hydride. The results show that the first decomposition reaction is more favorable one. The spontaneous decomposition reaction of K{sub 3}ZnH{sub 5} hydrides occur upon 465 K via reaction one, and 564 K via reaction two, respectively. - Graphical abstract: Total charge density of K{sub 3}ZnH{sub 5}. Highlights: Black-Right-Pointing-Pointer Electronic and thermodynamic properties of R{sub 3}ZnH{sub 5} (R=K, Rb, Cs) were calculated. Black-Right-Pointing-Pointer The formations of R{sub 3}ZnH{sub 5} hydrides are all exothermic at 298 K. Black-Right-Pointing-Pointer The thermodynamic stabilities decrease with the increasing diameter of R atom. Black-Right-Pointing-Pointer Two possible decomposition pathways of R{sub 3}ZnH{sub 5} were investigated.

36 MATERIALS SCIENCE↗

A simple differential steady-state method to measure the thermal conductivity of solid bulk materials with high accuracy

Accurate measurements of thermal conductivity are of great importance for materials research and development. Steady-state methods determine thermal conductivity directly from the proportionality between heat flow and an applied temperature difference (Fourier Law). Although theoretically simple, in practice, achieving high accuracies with steady-state methods is challenging and requires rather complex experimental setups due to temperature sensor uncertainties and parasitic heat loss. We developed a simple differential steady-state method in which the sample is mounted between an electric heater and a temperature-controlled heat sink. Our method calibrates for parasitic heat losses from the electric heater during the measurement by maintaining a constant heater temperature close to the environmental temperature while varying the heat sink temperature. This enables a large signal-to-noise ratio which permits accurate measurements of samples with small thermal conductance values without an additional heater calibration measurement or sophisticated heater guards to eliminate parasitic heater losses. Additionally, the differential nature of the method largely eliminates the uncertainties of the temperature sensors, permitting measurements with small temperature differences, which is advantageous for samples with high thermal conductance values and/or with strongly temperature-dependent thermal conductivities. In order to accelerate measurements of more than one sample, the proposed method allows for measuring several samples consecutively at each temperature measurement point without adding significant error. We demonstrate the method by performing thermal conductivity measurements on commercial bulk thermoelectric Bi 2 Te 3 samples in the temperature range of 30–150 °C with an error below 3%.

47 OTHER INSTRUMENTATION↗

Assessing the Dosimetric Impact of Real-Time Prostate Motion During Volumetric Modulated Arc Therapy

Purpose: To develop a method for dose reconstruction by incorporating the interplay effect between aperture modulation and target motion, and to assess the dosimetric impact of real-time prostate motion during volumetric modulated arc therapy (VMAT). Methods and Materials: Clinical VMAT plans were delivered with the TrueBeam linac for 8 patients with prostate cancer. The real-time target motion during dose delivery was determined based on the 2-dimensional fiducial localization using an onboard electronic portal imaging device. The target shift in each image was correlated with the control point with the same gantry angle in the VMAT plan. An in-house-developed Monte Carlo simulation tool was used to calculate the 3-dimensional dose distribution for each control point individually, taking into account the corresponding real-time target motion (assuming a nondeformable target with no rotation). The delivered target dose was then estimated by accumulating the dose from all control points in the plan. On the basis of this information, dose–volume histograms and 3-dimensional dose distributions were calculated to assess their degradation from the planned dose caused by target motion. Thirty-two prostate motion trajectories were analyzed. Results: The minimum dose to 0.03 cm{sup 3} of the gross tumor volume (D{sub 0.03cc}) was only slightly degraded after taking motion into account, with a minimum value of 94.1% of the planned dose among all patients and fractions. However, the gross tumor volume receiving prescription dose (V{sub 100%}) could be largely affected by motion, dropping below 60% in 1 trajectory. We did not observe a correlation between motion magnitude and dose degradation. Conclusions: Prostate motion degrades the delivered dose to the target in an unpredictable way, although its effect is reduced over multiple fractions, and for most patients the degradation is small. Patients with greater prostate motion or those treated with stereotactic body radiation therapy would benefit from real-time prostate tracking to reduce the margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance Assessment of a New Gamma Spectroscopy Toolkit: Peak Doctor and the Spectral Nondestructive Assay Platform (SNAP) - 17397

High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantitative Electron Nanodiffraction.

This Final report summarizes progress under this award for the final reporting period 2002 - 2013 in our development of quantitive electron nanodiffraction to materials problems, especially devoted to atomistic processes in semiconductors and electronic oxides such as the new artificial oxide multilayers, where our microdiffraction is complemented with energy-loss spectroscopy (ELNES) and aberration-corrected STEM imaging (9). The method has also been used to map out the chemical bonds in the important GaN semiconductor (1) used for solid state lighting, and to understand the effects of stacking sequence variations and interfaces in digital oxide superlattices (8). Other projects include the development of a laser-beam Zernike phase plate for cryo-electron microscopy (5) (based on the Kapitza-Dirac effect), work on reconstruction of molecular images using the scattering from many identical molecules lying in random orientations (4), a review article on space-group determination for the International Tables on Crystallography (10), the observation of energy-loss spectra with millivolt energy resolution and sub-nanometer spatial resolution from individual point defects in an alkali halide, a review article for the Centenary of X-ray Diffration (17) and the development of a new method of electron-beam lithography (12). We briefly summarize here the work on GaN, on oxide superlattice ELNES, and on lithography by STEM.

36 MATERIALS SCIENCE↗

Towards Efficient Uncertainty estimation in deep learning for robust energy prediction in crystal materials

In material science, recent studies have started to explore the potential of using deep learning to improve property prediction from high-fidelity simulations, e.g, density functional theory (DFT). However, the design spaces are sometimes too large and intractable to sample completely. This results in a critical question that is how to evaluate the confidence and robustness of the prediction. In this paper, we propose an efficient approach to estimate uncertainty in deep learning using a single forward pass and then apply it for robust prediction of the total energy in crystal lattice structures. Our approach is built upon the deep kernel learning (DKL) that originally introduces to leverage the expressiveness of deep neural networks as input with a probabilistic prediction of Gaussian processes (GPs) as output. Existing DKL methods have difficulties in the accuracy of predictive uncertainty, training stability, and scaling to large datasets, which lead to significant barriers in real-world applications. We propose to address these challenges by using an inducing point approximate GP in feature space combined with spectral normalization as a regularization. We finally demonstrate our robust performance on an artificial example and a real-world application from materials chemistry.

Bi, Sirui↗

Modified COMS Plaques for {sup 125}I and {sup 103}Pd Iris Melanoma Brachytherapy

Purpose: Novel plaques are used to treat iris melanoma at the Mayo Clinic Rochester. The plaques are a modification of the Collaborative Ocular Melanoma Study (COMS) 22 mm plaque design with a gold alloy backing, outer lip, and silicone polymer insert. An inner lip surrounds a 10 mm diameter cutout region at the plaque center. Plaques span 360{sup o}, 270{sup o}, and 180{sup o} arcs. This article describes dosimetry for these plaques and others used in the treatment of anterior eye melanomas. Methods and Materials: The EGSnrc user-code BrachyDose is used to perform Monte Carlo simulations. Plaques and seeds are fully modeled. Three-dimensional dose distributions for different plaque models, TG-43 calculations, and {sup 125}I (model 6711) and {sup 103}Pd (model 200) seeds are compared via depth-dose curves, tabulation of doses at points of interest, and isodose contours. Results: Doses at points of interest differ by up to 70% from TG-43 calculations. The inner lip reduces corneal doses. Matching plaque arc length to tumor extent reduces doses to eye regions outside the treatment area. Maintaining the same prescription dose, {sup 103}Pd offers lower doses to critical structures than {sup 125}I, with the exception of the sclera adjacent to the plaque. Conclusion: The Mayo Clinic plaques offer several advantages for anterior eye tumor treatments. Doses to regions outside the treatment area are significantly reduced. Doses differ considerably from TG-43 predictions, illustrating the importance of complete Monte Carlo simulations. Calculations take a few minutes on a single CPU, making BrachyDose sufficiently fast for routine clinical treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3-D Deep Penetration Neutron Imaging of Thick Absorgin and Diffusive Objects Using Transport Theory

A current area of research interest in national security is to effectively and efficiently determine the contents of the many shipping containers that enter ports in the United States. This interest comes as a result of the 9/11 Commission Act passed by Congress in 2007 that requires 100% of inbound cargo to be scanned by 2012. It appears that this requirement will be achieved by 2012, but as of February of 2009 eighty percent of the 11.5 million inbound cargo containers were being scanned. The systems used today in all major U.S. ports to determine the presence of radioactive material within cargo containers are Radiation Portal Monitors (RPM). These devices generally exist in the form of a gate or series of gates that the containers can be driven through and scanned. The monitors are effective for determining the presence of radiation, but offer little more information about the particular source. This simple pass-fail system leads to many false alarms as many everyday items emit radiation including smoke detectors due to the Americium-241 source contained inside, bananas, milk, cocoa powder and lean beef due to the trace amounts of Potassium-40, and fire brick and kitty litter due to their high clay content which often contains traces of uranium and thorium. In addition, if an illuminating source is imposed on the boundary of the container, the contents of the container may become activated. These materials include steel, aluminum and many agricultural products. Current portal monitors also have not proven to be that effective at identifying natural or highly enriched uranium (HEU). In fact, the best available Advanced Spectroscopic Portal Monitors (ASP) are only capable of identifying bare HEU 70-88% of the time and masked HEU and depleted uranium (DU) only 53 percent of the time. Therefore, a better algorithm that uses more information collected from better detectors about the specific material distribution within the container is desired. The work reported here explores the inverse problem of optical tomography applied to heterogeneous domains. The neutral particle transport equation was used as the forward model for how neutral particles stream through and interact within these heterogeneous domains. A constrained optimization technique that uses Newtons method served as the basis of the inverse problem. Optical tomography aims at reconstructing the material properties using (a) illuminating sources and (b) detector readings. However, accurate simulations for radiation transport require that the particle (gamma and/or neutron) energy be appropriate discretize in the multigroup approximation. This, in turns, yields optical tomography problems where the number of unknowns grows (1) about quadratically with respect to the number of energy groups, G, (notably to reconstruct the scattering matrix) and (2) linearly with respect to the number of unknown material regions. As pointed out, a promising approach could rely on algorithms to appropriately select a material type per material zone rather than G2 values. This approach, though promising, still requires further investigation: (a) when switching from cross-section values unknowns to material type indices (discrete integer unknowns), integer programming techniques are needed since derivative information is no longer available; and (b) the issue of selecting the initial material zoning remains. The work reported here proposes an approach to solve the latter item, whereby a material zoning is proposed using one-group or few-groups transport approximations. The capabilities and limitations of the presented method were explored; they are briefly summarized next and later described in fuller details in the Appendices. The major factors that influenced the ability of the optimization method to reconstruct the cross sections of these domains included the locations of the sources used to illuminate the domains, the number of separate experiments used in the reconstruction, the locations where measurements were collected, the optical thickness of the domain, the amount of signal noise and signal bias applied to the measurements and the initial guess for the cross section distribution. All of these factors were explored for problems with and without scattering. Increasing the number of source and measurement locations and experiments generally was more successful at reconstructing optically thicker domains while producing less error in the image. The maximum optical thickness that could be reconstructed with this method was ten mean free paths for pure absorber and two mean free paths for scattering problems. Applying signal noise and signal bias to the measured fluxes produced more error in the produced image. Generally, Newtons method was more successful at reconstructing domains from an initial guess for the cross sections that was greater in magnitude than their true values than from an initial guess that was lower in magnitude.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison Between DSMC and CFD for Hypersonic Planetary Entry Simulations

Hypersonic planetary entry flows span a wide range of Knudsen numbers between rarefied and continuum flows. While computational fluid dynamics (CFD) techniques cannot provide an accurate solution for flows in the rarefied regime, the direct simulation Monte Carlo (DSMC) method is capable of providing accurate solutions for flows in both in the rarefied and continuum regimes but becomes prohibitively expensive as the Knudsen number decreases. For the purpose of thermal protection systems (TPS) design and post-flight reconstruction, various selected points along an entry trajectory are often solved using hypersonic solvers. The quantities of interest that are obtained from that exercise are generally surface quantities, such as pressure, heat flux and enthalpy. Then, material response solvers are used to either design the heat shield to an optimal thickness based on a choice of material, or to provide in-depth heating profiles through the material at various select locations, and compare with flight instrumentation such as the ones that flew on NASA’s two most recent Mars missions, MSL and Mars2020. While most of the heating is generally experienced during the continuum part of the entry, the heating within the rarefied regime is significant for some atmospheres, and hence the flow solutions need to be computed using the DSMC method. Ensuring consistency between hypersonic CFD and the DSMC is crucial so that reliable surface quantities can be passed to material response solvers. Studies were performed to compare the two methods at various select locations, for both non-reacting argon flows as well reacting CO2/N2 flows. Preliminary conclusions show that, for non-reacting flows, the agreement between the two methods for surface heating is excellent (within expected uncertainties) for a freestream Knudsen number of 0.0006, and gets progressively worse as the Knudsen number increases to 0.06. Continuum breakdown analyses were performed and showed that, in general, the Gradient Length Local Knudsen number (KnGLL) from Boyd [1] and associated criteria (KnGLL > 0.05) can be accurately used to predict zones of breakdown in the flow, and associated errors for surface quantities. Furthermore, when studying reacting flow, our studies showed that while flow quantities are highly dependent on relaxation parameters and chemistry rates, it is possible to obtain a good agreement for surface heating, as long as the continuum breakdown in minimal (see Fig. 1). Finally, we studied the impact of the grid refinement on the surface quantities in DSMC.

DSMC↗

Comparison Between DSMC and CFD for Hypersonic Planetary Entry Simulations

Hypersonic planetary entry flows span a wide range of Knudsen numbers between rarefied and continuum flows. While computational fluid dynamics (CFD) techniques cannot provide an accurate solution for flows in the rarefied regime, the direct simulation Monte Carlo (DSMC) method is capable of providing accurate solutions for flows in both in the rarefied and continuum regimes but becomes prohibitively expensive as the Knudsen number decreases. For the purpose of thermal protection systems (TPS) design and post-flight reconstruction, various selected points along an entry trajectory are often solved using hypersonic solvers. The quantities of interest that are obtained from that exercise are generally surface quantities, such as pressure, heat flux and enthalpy. Then, material response solvers are used to either design the heat shield to an optimal thickness based on a choice of material, or to provide in-depth heating profiles through the material at various select locations, and compare with flight instrumentation such as the ones that flew on NASA’s two most recent Mars missions, MSL and Mars2020. While most of the heating is generally experienced during the continuum part of the entry, the heating within the rarefied regime is significant for some atmospheres, and hence the flow solutions need to be computed using the DSMC method. Ensuring consistency between hypersonic CFD and the DSMC is crucial so that reliable surface quantities can be passed to material response solvers. Studies were performed to compare the two methods at various select locations, for both non-reacting argon flows as well reacting CO2/N2 flows. Preliminary conclusions show that, for non-reacting flows, the agreement between the two methods for surface heating is excellent (within expected uncertainties) for a freestream Knudsen number of 0.0006, and gets progressively worse as the Knudsen number increases to 0.06. Continuum breakdown analyses were performed and showed that, in general, the Gradient Length Local Knudsen number (KnGLL) from Boyd and associated criterion (KnGLL > 0.05) seems conservative in predicting zones of breakdown in the flow, and associated errors for surface quantities. Updated criteria of KnGLL = 2.0 and 0.5 appear to be more appropriate for surface and flow quantities, respectively. Furthermore, when studying reacting flows, our studies showed that while flow quantities are highly dependent on relaxation parameters and chemistry rates, it is possible to obtain a good agreement for surface heating, as long as the continuum breakdown is minimal.

DSMC↗

Investigation and application of quantitative relationship between sp energy levels of Bi{sup 3+} ion and host lattice

Information on {sup 1}S{sub 0}-{sup 3}P{sub 1} (A band) and {sup 1}S{sub 0}-{sup 1}P{sub 1} (C band) transition energy of Bi{sup 3+} ion in dozens of different compounds has been gathered and analyzed. With the use of the dielectric theory of the chemical bond for complex crystals, relationships between A and C absorption band and environmental factor h{sub e} were established: E{sub A}=2.972+6.206exp (-h{sub e}/0.551); E{sub C}=3.236+10.924exp (-h{sub e}/0.644). For Bi{sup 3+} doped hosts with known structure and refractive index, it is possible to predict Bi{sup 3+} energy level position with an good accuracy of typically {+-}0.51 eV using the two relationships. Moreover, a direct relationship between A and C band was deduced: E{sub C}=3.236+2.290(E{sub A}-2.972){sup 0.856}. Thus a very simple method to predict C band position was proposed. This work will be of great help to understand spectroscopy of Bi{sup 3+} and will be useful for developing new PDP, LED and mercury-free fluorescent lamp phosphors. - Graphical abstract: This figure shows relationship between positions of A band and C band of Bi{sup 3+} ion and environmental factor h{sub e} of host. It establishes the relation between macroscopical spectroscopy of Bi{sup 3+} ion and microcosmic structure of the hosts. Highlights: Black-Right-Pointing-Pointer Relationships between A, C absorption band and environmental factor h{sub e} were established. Black-Right-Pointing-Pointer A direct relation between A and C band was deduced and an easier method to predict C band was given. Black-Right-Pointing-Pointer Positions of C band of Bi{sup 3+} ion in some compounds were predicted using our formula.

36 MATERIALS SCIENCE↗

Electron Microscopy Approaches to Unraveling the Structure of Amorphous Materials

Determining atomic structures in crystalline materials—where atoms are arranged in rigid, periodic lattices—has been highly successful using probes such as electrons, X-rays, and neutrons. In contrast, amorphous materials, despite their ubiquity and technological importance, remain far more challenging to characterize with comparable accuracy and precision. This review highlights existing, emerging, and potential (scanning) transmission electron microscopy ((S)TEM) techniques for probing short- and medium-range order in amorphous materials. Approaches ranging from high-resolution (S)TEM imaging and selected electron diffraction pattern to four-dimensional STEM (4D-STEM) based pair distribution function, fluctuation electron microscopy, tomography, ptychography, and spectroscopic methods are discussed, emphasizing their ability to provide complementary insights across multiple length scales—from sub-angstrom local environments to nanometer-scale correlations. Here, we further explore the promise of multimodal and correlative strategies, as well as the growing role of machine learning and physics-informed AI in enabling real-time, quantitative interpretation of complex structural signatures. Together, these advances point toward a future where electron microscopy not only reveals the hidden order in amorphous systems but also establishes robust structure–property relationships, paving the way for materials innovation in disordered matter.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Modeling adsorption properties of structurally deformed metal–organic frameworks using structure–property map

Structural deformation and collapse in metal-organic frameworks (MOFs) can lead to loss of long-range order, making it a challenge to model these amorphous materials using conventional computational methods. In this work, we show that a structure–property map consisting of simulated data for crystalline MOFs can be used to indirectly obtain adsorption properties of structurally deformed MOFs. The structure–property map (with dimensions such as Henry coefficient, heat of adsorption, and pore volume) was constructed using a large data set of over 12000 crystalline MOFs from molecular simulations. By mapping the experimental data points of deformed SNU-200, MOF-5, and Ni-MOF-74 onto this structure–property map, we show that the experimentally deformed MOFs share similar adsorption properties with their nearest neighbor crystalline structures. Furthermore, once the nearest neighbor crystalline MOFs for a deformed MOF are selected from a structure–property map at a specific condition, then the adsorption properties of these MOFs can be successfully transformed onto the degraded MOFs, leading to a new way to obtain properties of materials whose structural information is lost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Test of ASTM Methods E1245-03 and E562-11 in Calculating the Volume Fraction of Carbides in a U-10Mo Foil

Volume fraction measurements of carbides in DU-10Mo castings and foils were performed as part of a round robin study aimed at ensuring characterization efforts by multiple laboratories were yielding consistent results. Three of the four labs employed an automatic image analysis method to determine volume fraction of carbides in the metal and reported results around 2%. The other laboratory used a grid intercept count method and reported a fraction percentage of above 5%, about 3% higher than the other labs. At LANL, the method ASTM E1245-03, Determining the Inclusion or Second-Phase Constituent Content of Metals by Automatic Image Analysis was employed with a result of 2.02 ± .26%. There was a need to resolve the large discrepancy in volume fraction measurements reported from the round robin participant that used the grid intercept method. To do this, the grid intercept method outlined in ASTM E562-11, Determining Volume Fraction by Systematic Manual Point Count was also performed on the exact set of micrographs already analyzed by image analysis software at LANL. Calculations carried out following the manual point count method reported a percentage of 2.2 ± .6% similar to the result yielded by the automated image analysis method. Explanations for discrepancies in the results of the two methods are proposed.

36 MATERIALS SCIENCE↗

Raman structural studies of the nickel electrode

Raman spectroscopy is sensitive to empirically controlled nickel electrode structural variations, and has unique potential for structural characterization of these materials. How the structure relates to electrochemical properties is examined so that the latter can be more completely understood, controlled, and optimized. Electrodes were impregnated and cycled, and cyclic voltammetry is being used for electrochemical characterization. Structural variation was observed which has escaped detection using other methods. Structural changes are induced by: (1) cobalt doping, (2) the state of change or discharge, (3) the preparation conditions and type of buffer used, and (4) the formation process. Charged active mass has an NiOOH-type structure, agreeing with X-ray diffraction results. Discharged active mass, however, is not isostructural with beta-Ni(OH)2. Chemically prepared alpha phases are not isostructural either. A disordered structural model, containing point defects, is proposed for the cycled materials. This model explains K(+) incorporation. Band assignments were made and spectra interpreted for beta-Ni(OH)2, electrochemical NiOOH and chemically precipitated NiOOH.

Cornilsen, B. C.↗

Theoretical prediction of the fundamental properties for the ternary Li{sub 2}PtH{sub 6} and Na{sub 2}PtH{sub 6}

Li{sub 2}PtH{sub 6} and Na{sub 2}PtH{sub 6} are good candidate for hydrogen storage. The structural, elastic, electronic and optical properties of Li{sub 2}PtH{sub 6} and Na{sub 2}PtH{sub 6} compounds have been investigated using pseudo-potential plane-wave method based on the density functional theory. Computed lattice constant and H atom positional parameter at equilibrium agree well with the available experimental data. A quadratic pressure dependence of the elastic stiffness is found. A set of isotropic elastic parameters and related properties, namely bulk and shear moduli, Young's modulus, Poisson's ratio, average sound velocity and Debye temperature are numerically estimated in the framework of the Voigt-Reuss-Hill approximation for Li{sub 2}PtH{sub 6} and Na{sub 2}PtH{sub 6} polycrystalline aggregate. The analyses of the band structure indicates that Li{sub 2}PtH{sub 6} and Na{sub 2}PtH{sub 6} are indirect gap semiconductors. The static dielectric constant and static refractive index are inversely proportional to the fundamental gap. Highlights: Black-Right-Pointing-Pointer We predict elastic moduli, energy gaps and optical parameters. Black-Right-Pointing-Pointer Electron effective mass is anisotropic. Black-Right-Pointing-Pointer Li{sub 2}PtH{sub 6} and Na{sub 2}PtH{sub 6} are indirect gap semiconductors. Black-Right-Pointing-Pointer The contribution to the optical spectra from main transitions are predicted.

36 MATERIALS SCIENCE↗

Real time synchrotron x-ray diffraction measurements to determine material strength of shocked single crystals following compression and release

We present a method to use real time, synchrotron x-ray diffraction measurements to determine the strength of shocked single crystals following compression and release during uniaxial strain loading. Aluminum and copper single crystals shocked along [111] were examined to peak stresses ranging from 2 to 6 GPa. Synchrotron x rays were used to probe the longitudinal lattice strains near the rear free surface (16 and 5 {micro}m depths for Al and Cu, respectively) of the metal crystals following shock compression and release. The 111 diffraction peaks showed broadening indicating a heterogeneous microstructure in the released state. The diffraction peaks also shifted to lower Bragg angles relative to the ambient Bragg angle; the magnitude of the shift increased with increasing impact stress. The Bragg angle shifts and appropriate averaging procedures were used to determine the macroscopic or continuum strength following compression and release. For both crystals, the strengths upon release increased with increasing impact stress and provide a quantitative measure of the strain hardening that occurs in Al(111) and Cu(111) during the shock and release process. Our results for Al(111) are in reasonable agreement with a previous determination based solely on continuum measurements. Two points are noteworthy about the developments presented here: Synchrotron x rays are needed because they provide the resolution required for analyzing the data in the released state; the method presented here can be extended to the shocked state but will require additional measurements.

36 MATERIALS SCIENCE↗