Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material point method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Comparison Between DSMC and CFD for Hypersonic Planetary Entry Simulations

Hypersonic planetary entry flows span a wide range of Knudsen numbers between rarefied and continuum flows. While computational fluid dynamics (CFD) techniques cannot provide an accurate solution for flows in the rarefied regime, the direct simulation Monte Carlo (DSMC) method is capable of providing accurate solutions for flows in both in the rarefied and continuum regimes but becomes prohibitively expensive as the Knudsen number decreases. For the purpose of thermal protection systems (TPS) design and post-flight reconstruction, various selected points along an entry trajectory are often solved using hypersonic solvers. The quantities of interest that are obtained from that exercise are generally surface quantities, such as pressure, heat flux and enthalpy. Then, material response solvers are used to either design the heat shield to an optimal thickness based on a choice of material, or to provide in-depth heating profiles through the material at various select locations, and compare with flight instrumentation such as the ones that flew on NASA’s two most recent Mars missions, MSL and Mars2020. While most of the heating is generally experienced during the continuum part of the entry, the heating within the rarefied regime is significant for some atmospheres, and hence the flow solutions need to be computed using the DSMC method. Ensuring consistency between hypersonic CFD and the DSMC is crucial so that reliable surface quantities can be passed to material response solvers. Studies were performed to compare the two methods at various select locations, for both non-reacting argon flows as well reacting CO2/N2 flows. Preliminary conclusions show that, for non-reacting flows, the agreement between the two methods for surface heating is excellent (within expected uncertainties) for a freestream Knudsen number of 0.0006, and gets progressively worse as the Knudsen number increases to 0.06. Continuum breakdown analyses were performed and showed that, in general, the Gradient Length Local Knudsen number (KnGLL) from Boyd [1] and associated criteria (KnGLL > 0.05) can be accurately used to predict zones of breakdown in the flow, and associated errors for surface quantities. Furthermore, when studying reacting flow, our studies showed that while flow quantities are highly dependent on relaxation parameters and chemistry rates, it is possible to obtain a good agreement for surface heating, as long as the continuum breakdown in minimal (see Fig. 1). Finally, we studied the impact of the grid refinement on the surface quantities in DSMC.

DSMC↗

Comparison Between DSMC and CFD for Hypersonic Planetary Entry Simulations

Hypersonic planetary entry flows span a wide range of Knudsen numbers between rarefied and continuum flows. While computational fluid dynamics (CFD) techniques cannot provide an accurate solution for flows in the rarefied regime, the direct simulation Monte Carlo (DSMC) method is capable of providing accurate solutions for flows in both in the rarefied and continuum regimes but becomes prohibitively expensive as the Knudsen number decreases. For the purpose of thermal protection systems (TPS) design and post-flight reconstruction, various selected points along an entry trajectory are often solved using hypersonic solvers. The quantities of interest that are obtained from that exercise are generally surface quantities, such as pressure, heat flux and enthalpy. Then, material response solvers are used to either design the heat shield to an optimal thickness based on a choice of material, or to provide in-depth heating profiles through the material at various select locations, and compare with flight instrumentation such as the ones that flew on NASA’s two most recent Mars missions, MSL and Mars2020. While most of the heating is generally experienced during the continuum part of the entry, the heating within the rarefied regime is significant for some atmospheres, and hence the flow solutions need to be computed using the DSMC method. Ensuring consistency between hypersonic CFD and the DSMC is crucial so that reliable surface quantities can be passed to material response solvers. Studies were performed to compare the two methods at various select locations, for both non-reacting argon flows as well reacting CO2/N2 flows. Preliminary conclusions show that, for non-reacting flows, the agreement between the two methods for surface heating is excellent (within expected uncertainties) for a freestream Knudsen number of 0.0006, and gets progressively worse as the Knudsen number increases to 0.06. Continuum breakdown analyses were performed and showed that, in general, the Gradient Length Local Knudsen number (KnGLL) from Boyd and associated criterion (KnGLL > 0.05) seems conservative in predicting zones of breakdown in the flow, and associated errors for surface quantities. Updated criteria of KnGLL = 2.0 and 0.5 appear to be more appropriate for surface and flow quantities, respectively. Furthermore, when studying reacting flows, our studies showed that while flow quantities are highly dependent on relaxation parameters and chemistry rates, it is possible to obtain a good agreement for surface heating, as long as the continuum breakdown is minimal.

DSMC↗

Investigation and application of quantitative relationship between sp energy levels of Bi{sup 3+} ion and host lattice

Information on {sup 1}S{sub 0}-{sup 3}P{sub 1} (A band) and {sup 1}S{sub 0}-{sup 1}P{sub 1} (C band) transition energy of Bi{sup 3+} ion in dozens of different compounds has been gathered and analyzed. With the use of the dielectric theory of the chemical bond for complex crystals, relationships between A and C absorption band and environmental factor h{sub e} were established: E{sub A}=2.972+6.206exp (-h{sub e}/0.551); E{sub C}=3.236+10.924exp (-h{sub e}/0.644). For Bi{sup 3+} doped hosts with known structure and refractive index, it is possible to predict Bi{sup 3+} energy level position with an good accuracy of typically {+-}0.51 eV using the two relationships. Moreover, a direct relationship between A and C band was deduced: E{sub C}=3.236+2.290(E{sub A}-2.972){sup 0.856}. Thus a very simple method to predict C band position was proposed. This work will be of great help to understand spectroscopy of Bi{sup 3+} and will be useful for developing new PDP, LED and mercury-free fluorescent lamp phosphors. - Graphical abstract: This figure shows relationship between positions of A band and C band of Bi{sup 3+} ion and environmental factor h{sub e} of host. It establishes the relation between macroscopical spectroscopy of Bi{sup 3+} ion and microcosmic structure of the hosts. Highlights: Black-Right-Pointing-Pointer Relationships between A, C absorption band and environmental factor h{sub e} were established. Black-Right-Pointing-Pointer A direct relation between A and C band was deduced and an easier method to predict C band was given. Black-Right-Pointing-Pointer Positions of C band of Bi{sup 3+} ion in some compounds were predicted using our formula.

36 MATERIALS SCIENCE↗

Electron Microscopy Approaches to Unraveling the Structure of Amorphous Materials

Determining atomic structures in crystalline materials—where atoms are arranged in rigid, periodic lattices—has been highly successful using probes such as electrons, X-rays, and neutrons. In contrast, amorphous materials, despite their ubiquity and technological importance, remain far more challenging to characterize with comparable accuracy and precision. This review highlights existing, emerging, and potential (scanning) transmission electron microscopy ((S)TEM) techniques for probing short- and medium-range order in amorphous materials. Approaches ranging from high-resolution (S)TEM imaging and selected electron diffraction pattern to four-dimensional STEM (4D-STEM) based pair distribution function, fluctuation electron microscopy, tomography, ptychography, and spectroscopic methods are discussed, emphasizing their ability to provide complementary insights across multiple length scales—from sub-angstrom local environments to nanometer-scale correlations. Here, we further explore the promise of multimodal and correlative strategies, as well as the growing role of machine learning and physics-informed AI in enabling real-time, quantitative interpretation of complex structural signatures. Together, these advances point toward a future where electron microscopy not only reveals the hidden order in amorphous systems but also establishes robust structure–property relationships, paving the way for materials innovation in disordered matter.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Modeling adsorption properties of structurally deformed metal–organic frameworks using structure–property map

Structural deformation and collapse in metal-organic frameworks (MOFs) can lead to loss of long-range order, making it a challenge to model these amorphous materials using conventional computational methods. In this work, we show that a structure–property map consisting of simulated data for crystalline MOFs can be used to indirectly obtain adsorption properties of structurally deformed MOFs. The structure–property map (with dimensions such as Henry coefficient, heat of adsorption, and pore volume) was constructed using a large data set of over 12000 crystalline MOFs from molecular simulations. By mapping the experimental data points of deformed SNU-200, MOF-5, and Ni-MOF-74 onto this structure–property map, we show that the experimentally deformed MOFs share similar adsorption properties with their nearest neighbor crystalline structures. Furthermore, once the nearest neighbor crystalline MOFs for a deformed MOF are selected from a structure–property map at a specific condition, then the adsorption properties of these MOFs can be successfully transformed onto the degraded MOFs, leading to a new way to obtain properties of materials whose structural information is lost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Test of ASTM Methods E1245-03 and E562-11 in Calculating the Volume Fraction of Carbides in a U-10Mo Foil

Volume fraction measurements of carbides in DU-10Mo castings and foils were performed as part of a round robin study aimed at ensuring characterization efforts by multiple laboratories were yielding consistent results. Three of the four labs employed an automatic image analysis method to determine volume fraction of carbides in the metal and reported results around 2%. The other laboratory used a grid intercept count method and reported a fraction percentage of above 5%, about 3% higher than the other labs. At LANL, the method ASTM E1245-03, Determining the Inclusion or Second-Phase Constituent Content of Metals by Automatic Image Analysis was employed with a result of 2.02 ± .26%. There was a need to resolve the large discrepancy in volume fraction measurements reported from the round robin participant that used the grid intercept method. To do this, the grid intercept method outlined in ASTM E562-11, Determining Volume Fraction by Systematic Manual Point Count was also performed on the exact set of micrographs already analyzed by image analysis software at LANL. Calculations carried out following the manual point count method reported a percentage of 2.2 ± .6% similar to the result yielded by the automated image analysis method. Explanations for discrepancies in the results of the two methods are proposed.

36 MATERIALS SCIENCE↗

Raman structural studies of the nickel electrode

Raman spectroscopy is sensitive to empirically controlled nickel electrode structural variations, and has unique potential for structural characterization of these materials. How the structure relates to electrochemical properties is examined so that the latter can be more completely understood, controlled, and optimized. Electrodes were impregnated and cycled, and cyclic voltammetry is being used for electrochemical characterization. Structural variation was observed which has escaped detection using other methods. Structural changes are induced by: (1) cobalt doping, (2) the state of change or discharge, (3) the preparation conditions and type of buffer used, and (4) the formation process. Charged active mass has an NiOOH-type structure, agreeing with X-ray diffraction results. Discharged active mass, however, is not isostructural with beta-Ni(OH)2. Chemically prepared alpha phases are not isostructural either. A disordered structural model, containing point defects, is proposed for the cycled materials. This model explains K(+) incorporation. Band assignments were made and spectra interpreted for beta-Ni(OH)2, electrochemical NiOOH and chemically precipitated NiOOH.

Cornilsen, B. C.↗

Theoretical prediction of the fundamental properties for the ternary Li{sub 2}PtH{sub 6} and Na{sub 2}PtH{sub 6}

Li{sub 2}PtH{sub 6} and Na{sub 2}PtH{sub 6} are good candidate for hydrogen storage. The structural, elastic, electronic and optical properties of Li{sub 2}PtH{sub 6} and Na{sub 2}PtH{sub 6} compounds have been investigated using pseudo-potential plane-wave method based on the density functional theory. Computed lattice constant and H atom positional parameter at equilibrium agree well with the available experimental data. A quadratic pressure dependence of the elastic stiffness is found. A set of isotropic elastic parameters and related properties, namely bulk and shear moduli, Young's modulus, Poisson's ratio, average sound velocity and Debye temperature are numerically estimated in the framework of the Voigt-Reuss-Hill approximation for Li{sub 2}PtH{sub 6} and Na{sub 2}PtH{sub 6} polycrystalline aggregate. The analyses of the band structure indicates that Li{sub 2}PtH{sub 6} and Na{sub 2}PtH{sub 6} are indirect gap semiconductors. The static dielectric constant and static refractive index are inversely proportional to the fundamental gap. Highlights: Black-Right-Pointing-Pointer We predict elastic moduli, energy gaps and optical parameters. Black-Right-Pointing-Pointer Electron effective mass is anisotropic. Black-Right-Pointing-Pointer Li{sub 2}PtH{sub 6} and Na{sub 2}PtH{sub 6} are indirect gap semiconductors. Black-Right-Pointing-Pointer The contribution to the optical spectra from main transitions are predicted.

36 MATERIALS SCIENCE↗

Real time synchrotron x-ray diffraction measurements to determine material strength of shocked single crystals following compression and release

We present a method to use real time, synchrotron x-ray diffraction measurements to determine the strength of shocked single crystals following compression and release during uniaxial strain loading. Aluminum and copper single crystals shocked along [111] were examined to peak stresses ranging from 2 to 6 GPa. Synchrotron x rays were used to probe the longitudinal lattice strains near the rear free surface (16 and 5 {micro}m depths for Al and Cu, respectively) of the metal crystals following shock compression and release. The 111 diffraction peaks showed broadening indicating a heterogeneous microstructure in the released state. The diffraction peaks also shifted to lower Bragg angles relative to the ambient Bragg angle; the magnitude of the shift increased with increasing impact stress. The Bragg angle shifts and appropriate averaging procedures were used to determine the macroscopic or continuum strength following compression and release. For both crystals, the strengths upon release increased with increasing impact stress and provide a quantitative measure of the strain hardening that occurs in Al(111) and Cu(111) during the shock and release process. Our results for Al(111) are in reasonable agreement with a previous determination based solely on continuum measurements. Two points are noteworthy about the developments presented here: Synchrotron x rays are needed because they provide the resolution required for analyzing the data in the released state; the method presented here can be extended to the shocked state but will require additional measurements.

36 MATERIALS SCIENCE↗

Severe Dry Eye Syndrome After Radiotherapy for Head-and-Neck Tumors

Purpose: To investigate the incidence of severe dry eye syndrome (DES) after external beam radiotherapy for head-and-neck cancer and its dependence on the parameters relevant to external beam radiotherapy. Methods and Materials: The present retrospective study included 78 patients treated for primary extracranial head-and-neck tumors between 1965 and 2000, whose lacrimal apparatus/entire globe was exposed to fractionated external beam radiotherapy. The dose received by the major lacrimal gland was used for analysis. The end point of the present study was the ophthalmologic diagnosis of severe DES leading to vision compromise. Results: Of the 78 patients, 40 developed severe DES leading to visual compromise. The incidence of DES increased steadily from 6% at 35-39.99 Gy to 50% at 45-49.99 Gy and 90% at 60-64.99 Gy. With a mean of 0.9 years (range, 1 month to 3 years), the latency of DES was observed to be a function of the total dose and the dose per fraction. On univariate and multivariate analysis, the total dose (p < .0001 and p < .0001, respectively) and dose per fraction (p {<=} .0001 and p = .0044, respectively) were significant. However, age, gender, and the use of chemoradiotherapy were not. The actuarial analysis indicated a 5-year probability of freedom from DES of 93% for doses <45 Gy, 29% for 45-59.9 Gy, and 3% doses {>=}60 Gy. A logistic normal tissue complication probability model fit to our data obtained a dose of 34 and 38 Gy corresponding to a 5% and 10% incidence of DES. Conclusion: With a dose of 34 Gy corresponding to a 5% incidence of DES, the risk of severe DES increased, and the latency decreased with an increase in the total dose and dose per fraction to the lacrimal gland. The effect of chemoradiotherapy and hyperfractionation on the risk of DES needs additional investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gastrointestinal Dose-Histogram Effects in the Context of Dose-Volume–Constrained Prostate Radiation Therapy: Analysis of Data From the RADAR Prostate Radiation Therapy Trial

Purpose: To use a high-quality multicenter trial dataset to determine dose-volume effects for gastrointestinal (GI) toxicity following radiation therapy for prostate carcinoma. Influential dose-volume histogram regions were to be determined as functions of dose, anatomical location, toxicity, and clinical endpoint. Methods and Materials: Planning datasets for 754 participants in the TROG 03.04 RADAR trial were available, with Late Effects of Normal Tissues (LENT) Subjective, Objective, Management, and Analytic (SOMA) toxicity assessment to a median of 72 months. A rank sum method was used to define dose-volume cut-points as near-continuous functions of dose to 3 GI anatomical regions, together with a comprehensive assessment of significance. Univariate and multivariate ordinal regression was used to assess the importance of cut-points at each dose. Results: Dose ranges providing significant cut-points tended to be consistent with those showing significant univariate regression odds-ratios (representing the probability of a unitary increase in toxicity grade per percent relative volume). Ranges of significant cut-points for rectal bleeding validated previously published results. Separation of the lower GI anatomy into complete anorectum, rectum, and anal canal showed the impact of mid-low doses to the anal canal on urgency and tenesmus, completeness of evacuation and stool frequency, and mid-high doses to the anorectum on bleeding and stool frequency. Derived multivariate models emphasized the importance of the high-dose region of the anorectum and rectum for rectal bleeding and mid- to low-dose regions for diarrhea and urgency and tenesmus, and low-to-mid doses to the anal canal for stool frequency, diarrhea, evacuation, and bleeding. Conclusions: Results confirm anatomical dependence of specific GI toxicities. They provide an atlas summarizing dose-histogram effects and derived constraints as functions of anatomical region, dose, toxicity, and endpoint for informing future radiation therapy planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NDE of hybrid armor structures using acoustography

The US Army is investigating the use of composite materials to deliver lightweight and more effective armor protection systems to soldiers and other army assets. However, widespread use of such hybrid armor will require a reliable but fast NDE methodology to ensure integrity of these components during manufacturing and while in service. Traditional ultrasonic inspection of such hybrid armor structures may prove to be very effective, but point-by-point ultrasonic scanning is inherently time-consuming and manufacturing slowdowns could develop in high-volume production of such armor systems. In this paper, we report on the application of acoustography for the NDE of hybrid armor structures. Acoustography differs from conventional ultrasonic testing in that test objects are inspected in full field, analogously to real time x-ray imaging. The approach uses a novel, super high resolution large area acousto-optic (AO) sensor, which allows image formation through simple ultrasound shadow casting, analogous to x-ray image formation. This NDE approach offers significant inspection speed advantage over conventional point-by-point ultrasonic scanning procedures and is well-suited for high volume production. We will report initial results on a number of hybrid armor plate specimens employing composite materials that are being investigated by the US Army. Acoustography NDE results will also be verified using other complimentary NDE methods.

42 ENGINEERING↗

Neutron Time Projection Chamber for Nuclear Security and Verification Applications

Detection of fast neutrons produced by fission is a powerful method for discovering, verifying the presence, or monitoring significant quantities of special nuclear material (SNM) at up to moderate distances. Fast neutrons are relatively rare in the natural background and can be very penetrating, even in situations when the energetic gamma-rays are well shielded. Fast neutrons point in the direction of their source and can thus be considered for use in imaging, a feature desirable for rapid, high-signal-to-noise detection of concealed SNM and for nuclear verification. We describe the development and performance of a prototype neutron time projection chamber (nTPC) and its use for directional neutron detection and high-resolution neutron imaging. The nTPC is based on {approx}0.025 m{sup 3} of a hydrogen-methane mixture and utilizes a readout system with low channel count and is optimized for low event rates. We experimentally demonstrate robust operation, reliable particle identification, event-by-event directional reconstruction over the entire 4{pi} solid angle, and insensitivity to gamma-rays. High-efficiency and high-resolution modes of operation based on single and double neutron scatters, respectively, have also been demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous elastic and photoelastic calibration of birefringent orthotropic model materials

Transmission photoelastic analysis of composite models has been shown in recent years to be a viable stress analysis method for composite structures. However, difficulties in the fabrication of the model materials require the development of efficient mechanical and optical calibration procedures. In this paper, the methods for measuring elastic and photoelastic constants of composites are briefly reviewed. Then a new method, utilizing a relatively small calibration specimen, is described. In this method, electrical resistance strain gauges are mounted at selected points of a half-plane model and photoelastic measurements and strain readings are simultaneously taken. The data are processed by a least-squares procedure to yield the elastic and photoelastic constants. Comparison of results obtained by the proposed method with the results from conventional tests shows good agreement.

Prabhakaran, R.↗

Fracture of composites using singular finite elements

Six noded quarter point natural isoparametric triangular elements are employed to obtain displacement and stress distributions around the crack tip in unidirectional graphite epoxy. The performance of the quarter point element for predicting crack growth direction in unidirectional composite materials is studied for different loading conditions and fiber orientations. The finite element results are compared to analytical solutions of anisotropic elasticity where available. Notched Iosipescu shear specimens are analyzed to study fracture behavior under shear loading. Two methods for determining stress intensity factors are presented.

Choksi, G. N.↗

Variable Depth Bragg Peak Method for Single Event Effects Testing

Traditionally, accelerator SEE testing is accomplished by removing the tops of packages so that the IC chips are accessible to heavy ions. However, ICs in some advanced packages cannot be de-lidded so a different approach is used that involves grinding and/or chemically etching away part of the package and the chip from the back side. The parts are then tested from the back side with ions having sufficient range to reach the sensitive volume. More recently, the entire silicon substrate in an SOI/SRAM was removed, making it possible to use low-energy ions with shorter ranges. Where removal of part of the package is not possible, facilities at Michigan State, NASA Space Radiation Laboratory, GANIL (France) and GSI (Germany) offer high-energy heavy ions with long ranges so that the ions can reach the devices' sensitive volumes without much change in the LET. Unfortunately, a run will typically involve only one ion species having a single energy and LET due to the long time it takes to tune a new energy. The Variable Depth Bragg Peak (VDBP) method is similar to the above method in that it involves the use of high-energy heavy ions that are able to pass through the packaging material and reach the device, obviating the need to remove the package. However, the method provides a broad range of LETs from a single ion by inserting degraders in the beam that modify the ion energy and, therefore, the LET. The crux of the method involves establishing a fiduciary point for degrader thickness, i.e., where the Bragg peak is located precisely at the sensitive volume in the device, for which the measured SEU cross-section and the ion LET are both also maxima and can be calculated using a Monte-Carlo program, TRIM. Once the fiduciary point has been established, calibrated high density polyethylene (HDPE) degraders are inserted into or removed from the beam to vary the ion LET at the device in a known manner. After each change of degrader thickness, the SEU cross-section is measured and the corresponding LET calculated from the change in degrader thickness. That information is used to generate a plot of cross-section as a function of ion LET. The advantages of this approach are that the part does not have to be de-lidded and a broad range of LETs is available from a single heavy ion without having to go to non-normal angles of incidence to change the "effective" LET. As we will show, it is possible to obtain an entire curve of cross-section versus LET using just two or three ions. Fig. 1 shows curves of cross-section vs LET for a Freescale 4 Mbit SOI/SRAM measured at the 88" Cyclotron at Berkeley and at NSRL. The open symbols are the data obtained from Berkeley for top-side and back-side irradiation. The solid data points are for the data obtained at NSRL using a device for which the package was intact. The data are for Iron and Gold and cover a range of LETs from 4 MeV.cm2/mg to 84 MeV.cm2/mg. The agreement between the data obtained from Berkeley and from NSRL is excellent, demonstrating that the VDBP method is capable of providing accurate values of cross-section versus LET, at least for the 4 Mbit SRAM. Details of the technique will be included in the final presentation.

Buchner, S.↗

Comparing urban solid waste recycling from the viewpoint of urban metabolism based on physical input-output model: A case of Suzhou in China

Highlights: Black-Right-Pointing-Pointer Impacts of solid waste recycling on Suzhou's urban metabolism in 2015 are analyzed. Black-Right-Pointing-Pointer Sludge recycling for biogas is regarded as an accepted method. Black-Right-Pointing-Pointer Technical levels of reusing scrap tires and food wastes should be improved. Black-Right-Pointing-Pointer Other fly ash utilization methods should be exploited. Black-Right-Pointing-Pointer Secondary wastes from reusing food wastes and sludge should be concerned. - Abstract: Investigating impacts of urban solid waste recycling on urban metabolism contributes to sustainable urban solid waste management and urban sustainability. Using a physical input-output model and scenario analysis, urban metabolism of Suzhou in 2015 is predicted and impacts of four categories of solid waste recycling on urban metabolism are illustrated: scrap tire recycling, food waste recycling, fly ash recycling and sludge recycling. Sludge recycling has positive effects on reducing all material flows. Thus, sludge recycling for biogas is regarded as an accepted method. Moreover, technical levels of scrap tire recycling and food waste recycling should be improved to produce positive effects on reducing more material flows. Fly ash recycling for cement production has negative effects on reducing all material flows except solid wastes. Thus, other fly ash utilization methods should be exploited. In addition, the utilization and treatment of secondary wastes from food waste recycling and sludge recycling should be concerned.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Statistically Rigorous Uncertainty Quantification for Physical Parameter Model Calibration with Functional Output

In experiments conducted on the Z-machine at Sandia National Laboratories, dynamic material properties cannot be analyzed using traditional analytic methods, necessitating solving an inverse problem. Bayesian model calibration is a statistical framework for solving an inverse problem to estimate parameters input into a computational model in the presence of multiple uncertainties. Disentangling input parameter uncertainty and model misspecification is often poorly identified problem. When using computational models for physical parameter estimation, the issue of parameter identifiability must be carefully considered to obtain accurate and precise estimates of physical parameters. Additionally, in dynamic material properties applications, the experimental output is a function, velocity over time. While we can sample an arbitrarily large number of points from the measured velocity, these curves only contain a finite amount of information about the calibration parameters. In this report, we propose modifications to the Bayesian model calibration framework to simplify and improve the estimation of physical parameters with functional outputs. Specifically, we propose scaling the likelihood function by an effective sample size rather than modeling the discrepancy function; and modularizing input nuisance parameters with weakly identified parameters. We evaluate the performance of these proposed methods using a statistical simulation study and then apply these methods to estimate parameters of the tantalum equation of state. We conclude that these proposed methods can provide simple, fast, and statistically valid alternatives to the full Bayesian model calibration procedure; and that these methods can be used to estimate parameters of the equation of state for tantalum.

97 MATHEMATICS AND COMPUTING↗