Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

High temperature fiber-optic evanescent wave hydrogen sensors using La-doped SrTiO 3 for SOFC applications

Advanced sensors are needed for development of next-generation fossil fuel power generation technologies and for enhancing efficiencies of existing power generation systems. Optical waveguide-based sensing technologies have become increasingly important for harsh environment energy applications. In this manuscript, we present sensing results for fiber-optic evanescent wave hydrogen sensors employing La-doped SrTiO 3 layers as the active sensing element. These sensors show a rapid, reproducible sensing response to hydrogen fuel gas streams at elevated temperatures (600–800 °C). The presence of hydrogen results in a reversible and reproducible decrease in near-infrared transmission through the sensor. In conclusion, sensors were also tested directly in the anode assembly of an operating solid oxide fuel cell (SOFC) with the sensor response correlating with both H 2 concentration and SOFC cell potential.

30 DIRECT ENERGY CONVERSION↗

Leak Detection and Sensor Importance Within a Solvent Extraction Process Abstract

In anticipation of the Special Nuclear Material test bed (Beartooth), Idaho National Laboratory has developed a smaller, multi-sensor system for analyzing the solvent extraction process. These systems will allow for research into nuclear fuel processing operations. The multi-sensor system consists of a row of centrifugal contactors and allows for measurement sources that are not traditionally used in the solvent extraction process to be explored including temperature, vibration, acoustics, pH, color, flow, and motor current. Currently, the solvent extraction process is very labor intensive and requires vigilant operators to identify the occurrence of leaks, which can be common during startup or after any change to the system. This study aims to locate leaks using non-traditional measurement sources then to identify which signals were of greatest importance in making this classification using Local Interpretable Model-agnostic Explanations. These results can be used to help solvent extraction process operators detect leaks and to inform future test beds designers to which sensors contain relevant, actionable information in this scenario.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MICROCALORIMETER SPECTROSCOPY AT HIGH PULSE RATES: A MULTI-PULSE FITTING TECHNIQUE

Transition Edge Sensor microcalorimeters can measure X-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future X-ray observatories, each sensor must be able to measure hundreds or even thousands of photon energies per second. Current “optimal filtering” approaches to achieve the best possible energy resolution work only for photons that are well isolated in time, a requirement which is in direct conflict with the need for high-rate measurements. We describe a new analysis procedure to allow fitting for the pulse height of all photons even in the presence of heavy pulse pile-up. In the limit of isolated pulses, the technique reduces to standard optimal filtering with long records. We employ reasonable approximations to the noise covariance function in order to render this procedure computationally viable even for very long data records. The technique is employed to analyze X-ray emission spectra at 600 eV and 6 keV at rates up to 250 counts s{sup −1} in microcalorimeters having exponential signal decay times of approximately 1.2 ms.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments for MSRs

This report serves as the deliverable for Milestone M3RS-23AN0401061 that is part of Work Package RS-23AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone was to determine performance of the flow enhanced electrochemical sensor (FEES) and modular flow instrumentation testbed (MFIT) in safeguards relevant scenarios. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. To further improve this capability, in FY23 we undertook a campaign of safeguards relevant scenarios in molten salt containing a range of uranium chloride concentrations (0 to 3 wt%). All the testing carried out in FY23 was aided by a control system designed to automatically actuate flow conditions and collect data. This new automation system is estimated to have increased experimental throughput by a factor of four and enabled testing in a variety of complex conditions. The advancements in throughput and repeatability led to improved quantification of actinide concentrations using the in-flow sensors, with a reduction of the mean absolute relative error from 5.6% in FY22 to 3.1% in FY23. In addition to safeguards scenarios run in the MFIT, FY23 work included deployment of a FEES at a partner institution where it will be tested in a flowing salt loop. The FEES was successfully integrated into that loop and is being tested prior to loop startup. In FY23, work also continued on the smaller flow system that we have named the mini-MFIT. This smaller system is capable of rapid prototyping of new sensor designs prior to installation in the larger MFIT radiological flow system. Work was carried out to test this new system in non-radiological molten salts in a separate glovebox. This work is helping us to enhance the accuracy of our salt monitoring capabilities through the integration of multiple types of sensors. The high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will be needed to further push the measurement accuracy to the needed level.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Self characterization of a coded aperture array for neutron source imaging

The neutron imaging system at the National Ignition Facility (NIF) is an important diagnostic tool for measuring the two-dimensional size and shape of the neutrons produced in the burning deuterium-tritium plasma during the stagnation stage of inertial confinement fusion implosions. Since the neutron source is small (∼100 μm) and neutrons are deeply penetrating (>3 cm) in all materials, the apertures used to achieve the desired 10-μm resolution are 20-cm long, triangular tapers machined in gold foils. These gold foils are stacked to form an array of 20 apertures for pinhole imaging and three apertures for penumbral imaging. These apertures must be precisely aligned to accurately place the field of view of each aperture at the design location, or the location of the field of view for each aperture must be measured. In this paper we present a new technique that has been developed for the measurement and characterization of the precise location of each aperture in the array. We present the detailed algorithms used for this characterization and the results of reconstructed sources from inertial confinement fusion implosion experiments at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and Application of Gas Sensing Technologies to Enable Boiler Balancing

Identifying gas species and their quantification is important for optimization of many industrial applications involving high temperatures, including combustion processes. CISM (Center for Industrial Sensors and Measurements) at the Ohio State University has developed CO, O{sub 2}, NO{sub x}, and CO{sub 2} sensors based on TiO{sub 2} semiconducting oxides, zirconia and lithium phosphate based electrochemical sensors and sensor arrays for high-temperature emission control. The underlying theme in our sensor development has been the use of materials science and chemistry to promote high-temperature performance with selectivity. A review article presenting key results of our studies on CO, NO{sub x}, CO{sub 2} and O{sub 2} sensors is described in: Akbar, Sheikh A.; Dutta, Prabir K. Development and Application of Gas Sensing Technologies for Combustion Processes, PowerPlant Chemistry, 9(1) 2006, 28-33.

01 COAL, LIGNITE, AND PEAT↗

Development of a 1 x N Fiber Optic Sensor Array for Carbon Sequestration Site Monitoring

A fiber sensor array for sub-surface CO 2 concentrations measurements was developed for monitoring geologic carbon sequestration sites. The fiber sensor array uses a single temperature tunable distributed feedback (DFB) laser operating with a nominal wavelength of 2.004 μm. Light from this DFB laser is direct to one of the 4 probes via an in-line 1 x 4 fiber optic switch. Each of the 4 probes are buried and allow the sub-surface CO 2 to enter the probe through Millipore filters that allow the soil gas to enter the probe but keeps out the soil and water. Light from the DFB laser interacts with the CO 2 before it is directed back through the in-line fiber optic switch. The DFB laser is tuned across two CO 2 absorption features where a transmission measurement is made allowing the CO 2 concentration to be retrieved. The fiber optic switch then directs the light to the next probe where this process is repeated allowing sub-surface CO 2 concentration measurements at each of the probes to be made as a function of time. The fiber sensor array was deployed for fifty-eight days beginning June 19, 2012 at the Zero Emission Research Technology (ZERT) field site where sub-surface CO 2 concentrations were monitored. Background measurements indicate the fiber sensor array can monitor background levels as low as 1,000 parts per million (ppm). A thirty four day sub-surface release of 0.15 tones CO 2 /day began on July 10, 2012. The elevated subsurface CO 2 concentration was easily detected by each of the four probes with values ranging to over 60,000 ppm, a factor of greater than 6 higher than background measurements. The fiber sensor array was also deploy at the Big Sky Carbon Sequestration Partnership (BSCSP) site in north-central Montana between July 9th and August 7th, 2013 where background measurements were made in a remote sequestration site with minimal infrastructure. The project provided opportunities for two graduate students to participate in research directly related to geologic carbon sequestration. Furthermore, commercialization of the technology developed is being pursued with five different companies via the Department of energy SBIR/STTR program

47 OTHER INSTRUMENTATION↗

Fiber-Optic Bolometer and Calorimeter Arrays for Magnetically Confined Plasmas

Bolometers measure the plasma radiation and provide essential diagnostic information both for safe, sustainable operation of magnetic-confinement fusion (MCF) devices and for study of the relevant physics. The fusion community has been replying on resistive bolometers for plasma radiation measurement. However, their performance is greatly compromised by the strong electromagnetic interference present in MCF devices. Previously, we have demonstrated a fiber-optic bolometer that has the promise to overcome the challenges related to the strong EMI in the MCF environment. In this project, we study the performance of the fiber-optic bolometer in a simulated MCF environment and improved the sensitivity through a novel sensor design. Part of the work reported here was performed between 09/01-12/31/2017 when the PI was with University of Nebraska-Lincoln under the same project but with a different award number (DE-SC0018273).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Continuous surface-to-distributed acoustic sensor snapshots explain reactivation of individual natural fractures during an unconventional reservoir stimulation

ABSTRACT Fiber-optic sensing technologies allow petroleum engineering teams to detect hydraulic fracture interaction with boreholes during unconventional reservoir stimulation. In combination with high-repeatability seismic sources, the same distributed acoustic sensors (DASs) enable vertical seismic profiling (VSP) of the fracture evolution away from the boreholes. We discovered clear signatures of seismic scattering on activated fractures during nine days of continuous seismic monitoring of the fracturing stages at the Austin Chalk/Eagle Ford Field Laboratory. The present study applies a novel approach for quantitative analysis of the scattering events in terms of the evolution of the geometry and elastic stiffness of individual fractures. Our characterization strategy sequentially refines the fracture models: from a stack of 1D soft layers to 3D rectangular inclusions. First, we estimate the number of fracture locations and reflectivity using a modified sparse-spike deconvolution of the stacked VSP traces. The fracture set consists of five fractures spaced by 15–30 m with a reflectivity of approximately 1%. Then, we develop a scattering integral method to refine these estimates along with an inversion of the fracture top and bottom for each monitoring vintage. We find that, initially, some of the fractures are located above the monitoring fiber with the height of approximately 100 m. Then we integrate the seismic interpretation with the low-frequency DAS and pressure and microseismic monitoring to reconstruct the activation process of the fractures. Most likely, some of the natural fractures slowly grew downward to the monitoring fiber as a result of fluid injections in the stimulated well. This led to bright strain anomalies but did not trigger seismicity. The top of the fractures remained almost constant and were limited by a lithologic boundary/stress barrier. To our knowledge, this is the first time VSP data enabled tracking of the fracture evolution with such high spatial and temporal resolution, which was previously only available for crosswell surveys and at a much smaller scale.

Glubokovskikh, Stanislav↗

Smart sensors using artificial intelligence for on-detector electronics and ASICs

Cutting edge detectors push sensing technology by further improving spatial and temporal resolution, increasing detector area and volume, and generally reducing backgrounds and noise. This has led to a explosion of more and more data being generated in next-generation experiments. Therefore, the need for near-sensor, at the data source, processing with more powerful algorithms is becoming increasingly important to more efficiently capture the right experimental data, reduce downstream system complexity, and enable faster and lower-power feedback loops. In this paper, we discuss the motivations and potential applications for on-detector AI. Furthermore, the unique requirements of particle physics can uniquely drive the development of novel AI hardware and design tools. We describe existing modern work for particle physics in this area. Finally, we outline a number of areas of opportunity where we can advance machine learning techniques, codesign workflows, and future microelectronics technologies which will accelerate design, performance, and implementations for next generation experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Perspective on Improving Environmental Monitoring of Biothreats

For more than a decade, the United States has performed environmental monitoring by collecting and analyzing air samples for a handful of biological threat agents (BTAs) in order to detect a possible biological attack. This effort has faced numerous technical challenges including timeliness, sampling efficiency, sensitivity, specificity, and robustness. The cost of city-wide environmental monitoring using conventional technology has also been a challenge. A large group of scientists with expertise in bioterrorism defense met to assess the objectives and current efficacy of environmental monitoring and to identify operational and technological changes that could enhance its efficacy and cost-effectiveness, thus enhancing its value. The highest priority operational change that was identified was to abandon the current concept of city-wide environmental monitoring because the operational costs were too high and its value was compromised by low detection sensitivity and other environmental factors. Instead, it was suggested that the focus should primarily be on indoor monitoring and secondarily on special-event monitoring because objectives are tractable and these operational settings are aligned with likelihood and risk assessments. The highest priority technological change identified was the development of a reagent-less, real-time sensor that can identify a potential airborne release and trigger secondary tests of greater sensitivity and specificity for occasional samples of interest. This technological change could be transformative with the potential to greatly reduce operational costs and thereby create the opportunity to expand the scope and effectiveness of environmental monitoring.

Dunbar, John↗

Completion of Irradiation of Sensors in ATRC Milestone

This set of PowerPoint slides demonstrates how milestone "M2CT-21IN0702023: Perform test of neutron flux sensors in the Advanced Test Reactor Critical Facility". It supports an entry in PICS claiming achievement of the milestone. These slides provide a good summary of the purpose and impact of the milestone for our DOE Headquarters colleagues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microbial potentiometric sensor array measurements in unsaturated soils

The overarching goal of this study is to demonstrate a novel technology for monitoring changes in electrical potential of unsaturated soils using biofilm-populated electrodes. The novelty of the study stems from the fact that it demonstrates a method for measuring open-circuit potentials (OCP) in environments without the presence of an electrolyte solution. This study also reveals that using a biofilm-populated electrode as a reference in stable environments could successfully be employed to assess and monitor the electrochemical potential generated by plants and microorganisms. The findings imply that long-term (months to years) and real-time measurements of the open-circuit potential in unsaturated soils are possible. Because MPS arrays can directly measure open-circuit potential from the biofilm, the challenges related to locally induced electrochemical changes caused by microorganisms in the soil to achieve optimum physiological levels are eliminated. The simplicity of the technology, which allows for multiple indicator electrodes to be referenced against an “internal” reference electrode, enables spatial-temporal monitoring of the changes in the soil and the generation of 2D- or 3D-signal patterns. Once a signal pattern, generated by an array of sensors, develops (usually after 30 to 90 days), it does not significantly change unless the soil is exposed to external stimuli. The observed OCP phenomena, however, suggests that the change in OCP signal is independent of changes in soil conductivity resulting from the addition of water. In brief, findings suggest that the proposed technology can enable multidimensional profiling and long-term monitoring of changes occurring in unsaturated soils without direct implications of presence of water. The changes in the 2D or 3-D signal patterns, however, can be correlated to other important parameters that characterize soil health.

54 ENVIRONMENTAL SCIENCES↗

Earthquake detection in a simulated lunar regolith using distributed acoustic sensing

Current models of inner lunar geology have largely been inferred from the seismic experiments and observations performed during the Apollo missions that comprised a relatively small number of seismic instruments. Refining constraints on fundamental lunar relationships such as crust-mantle and mantle-core boundaries in the future will require seismic arrays spanning larger epicentral distances. A promising technology for installing dense seismic arrays with minimal human effort is distributed acoustic sensing (DAS), an approach that allows a single length of fiber optic cable to act as hundreds or thousands of sensors when coupled with a DAS interrogator. While terrestrial uses of DAS technology for seismic monitoring rely on burying the cable to maximize fidelity of seismic signal transmission to the fiber, digging meters of trench to bury optical fiber on lunar or planetary surfaces is logistically infeasible. To evaluate DAS signal attenuation due to surface deployment of cable in lunar regolith, we completed earthquake detection analyses that evaluated the sensitivity of an optic-fiber DAS system to seismic signals at different burial depths. We deployed a single-mode fiber in a 10-m open-bottom wooden box filled with a lunar regolith simulant (LRS) with fiber buried at different depths within the LRS and recorded signals for four regional and local earthquakes. The results were used to identify and evaluate signal attenuation in surface-deployed fiber compared to buried fiber in the LRS. Burial depth responses to active-source signals were also evaluated similar to previous studies characterizing DAS sensitivity of surface-deployed fiber. Atmospheric noise was minimal as the cable was deployed in an indoor environment; however, where observed, atmospheric and anthropogenic noise was filtered out using the same bandpass filtering used to identify earthquake events. We found that signal attenuation of the surface-deployed fiber compared to buried fiber was relatively high in active-source experiments but was not consistently observed in earthquake signals. That burial depth is not highly correlated to attenuation of the observed earthquake signals indicates that in a noise-limited environment, placing DAS-interrogated fiber directly at the regolith surface may be a promising deployment strategy to consider for sensing remote seismic signals during lunar exploration.

58 GEOSCIENCES↗