Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Crosstalk Effects in Microwave SQUID Multiplexed TES Bolometer Readout

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, in this study, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A New Residual Strain Mapping Program Using Energy Dispersive X-Ray Diffraction at the Advanced Photon Source

Here, the ability to non-destructively map the residual strain field inside an engineering component is important for predicting its fatigue life or developing processing methods to prevent failure or enhance performance. In this paper, we describe a new residual strain mapping program at the Advanced Photon Source, Argonne National Laboratory. The new program is based on energy dispersive x-ray diffraction (EDXRD). It is capable of non-destructively penetrating a several- cm thick polycrystalline sample fabricated from engineering alloys using high-energy x-rays and measuring the residual strain field with mm or better spatial resolution and approximately ±1 x 10 -4 strain resolution. A multi-element detector array is employed to measure multiple strain components simultaneously. The residual strain mapping setup is augmented with a high-energy tomography capability, allowing precise alignment of the material volume of interest for residual strain mapping and providing a complementary view of the structure to understand the measured strain field. These measurement capabilities are demonstrated using several strain mapping examples ranging from polycrystalline structural alloys to biological materials. We also provide some guidance for the future users of the program for a successful residual strain mapping experiment. We are expanding the capabilities of the new setup with various in situ capabilities including thermo-mechanical loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid recoil mass analyzer at IUAC - First results using gas-filled mode and future plans

Hybrid recoil mass analyzer (HYRA) is a unique, dual-mode spectrometer designed to carry out nuclear reaction and structure studies in heavy and medium-mass nuclei using gas-filled and vacuum modes, respectively and has the potential to address newer domains in nuclear physics accessible using high energy, heavy-ion beams from superconducting LINAC accelerator (being commissioned) and ECR-based high current injector system (planned) at IUAC. The first stage of HYRA is operational and initial experiments have been carried out using gas-filled mode for the detection of heavy evaporation residues and heavy quasielastic recoils in the direction of primary beam. Excellent primary beam rejection and transmission efficiency (comparable with other gas-filled separators) have been achieved using a smaller focal plane detection system. There are plans to couple HYRA to other detector arrays such as Indian national gamma array (INGA) and 4 spin spectrometer for ER tagged spectroscopic/spin distribution studies and for focal plane decay measurements.

43 PARTICLE ACCELERATORS↗

Effects of Magnetic and Electric Field Uniformity on Coded Aperture Imaging Quality in a Cycloidal Mass Analyzer

Cycloidal mass analyzers are unique sector mass analyzers as they exhibit perfect double focusing, making them ideal for incorporating spatial aperture coding, which can increase the throughput of a mass analyzer without affecting the resolving power. However, the focusing properties of the cycloidal mass analyzer depend on the uniformity of the electric and magnetic fields. In this paper, finite element simulation and charged particle tracing were used to investigate the effect of field uniformity on imaging performance of a cycloidal mass analyzer. For the magnetic field, we evaluate a new permanent magnet geometry by comparing it to a traditional geometry. Results indicate that creating an aperture image in a cycloidal mass spectrometer with the same FWHM as the slit requires less than 1% variation in magnetic field strength along the ion trajectories. The new magnet design, called the opposed dipole magnet, has less than 1% field variation over an area approximately 62 × 65 mm; nearly twice the area available in a traditional design of similar size and weight. This allows ion imaging across larger detector arrays without loss of resolving power. In addition, we compare the aperture imaging quality of a traditionally used cycloidal mass spectrometer electric design with a new optimized design with improved field uniformity. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for First Harmonic Modulation in the Right Ascension Distribution of Cosmic Rays Detected at the Pierre Auger Observatory

We present the results of searches for dipolar-type anisotropies in different energy ranges above 2.5 x 10{sup 17} eV with the surface detector array of the Pierre Auger Observatory, reporting on both the phase and the amplitude measurements of the first harmonic modulation in the right-ascension distribution. Upper limits on the amplitudes are obtained, which provide the most stringent bounds at present, being below 2% at 99% C.L. for EeV energies. We also compare our results to those of previous experiments as well as with some theoretical expectations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In situ time-resolved X-ray diffraction of tobermorite formation in autoclaved aerated concrete: Influence of silica source reactivity and Al addition

The hydrothermal formation of tobermorite during the processing of autoclaved aerated concrete was investigated by in situ X-ray diffraction (XRD) analysis. High-energy X-rays from a synchrotron radiation source in combination with a newly developed autoclave cell and a photon-counting pixel array detector were used. To investigate the effects of the silica source, reactive quartz from chert and less-reactive quartz from quartz sand were used as starting materials. The effect of Al addition on tobermorite formation was also studied. In all cases, C-S-H, hydroxylellestadite and katoite were clearly observed as intermediates. Acceleration of tobermorite formation by Al addition was clearly observed. However, Al addition did not affect the dissolution rate of quartz. Two pathways, via C-S-H and katoite, were also observed in the Al-containing system. These results suggest that the structure of initially formed C-S-H is important for the subsequent tobermorite formation reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Column properties and flow profiles of a flat, wide column for high-pressure liquid chromatography

The design and the construction of a pressurized, flat, wide column for high-performance liquid chromatography (HPLC) are described. This apparatus, which is derived from instruments that implement over-pressured thin layer chromatography, can carry out only uni-dimensional chromatographic separations. However, it is intended to be the first step in the development of more powerful instruments that will be able to carry out two-dimensional chromatographic separations, in which case, the first separation would be a space-based separation, LC{sup x}, taking place along one side of the bed and the second separation would be a time-based separation, LC{sup t}, as in classical HPLC but proceeding along the flat column, not along a tube. The apparatus described consists of a pressurization chamber made of a Plexiglas block and a column chamber made of stainless steel. These two chambers are separated by a thin Mylar membrane. The column chamber is a cavity which is filled with a thick layer (ca. 1 mm) of the stationary phase. Suitable solvent inlet and outlet ports are located on two opposite sides of the sorbent layer. The design allows the preparation of a homogenous sorbent layer suitable to be used as a chromatographic column, the achievement of effective seals of the stationary phase layer against the chamber edges, and the homogenous flow of the mobile phase along the chamber. The entire width of the sorbent layer area can be used to develop separations or elute samples. The reproducible performance of the apparatus is demonstrated by the chromatographic separations of different dyes. This instrument is essentially designed for testing detector arrays to be used in a two-dimensional LC{sup x} x LC{sup t} instrument. The further development of two-dimension separation chromatographs based on the apparatus described is sketched.

36 MATERIALS SCIENCE↗

Design and engineering challenges of a multi-energy hard x-ray camera for long-pulse profile measurements at WEST tokamak

The WEST tokamak has recently been prepared for long pulse operation with a water-cooled full first wall. Heating is provided by radiofrequency systems, including Lower Hybrid Current Drive (LHCD). The Princeton Plasma Physics Laboratory has developed a multi-energy hard x-ray camera for profile measurements at WEST. The camera is based on a new generation of 2D pixel array detectors that allow the energy threshold to be independently set for each pixel. The diagnostic will provide spatial, temporal and energy resolved measurements of the hard x-ray emission from the full plasma cross-section, investigating several physical quantities such as the electron temperature from continuum emission, the fast electron tail density produced by radiofrequency current drive and runaway electrons, as well as characteristic tungsten x-rays due to beam-target emission at the edge. Overall, this work describes the engineering challenges that the WEST long pulse scenario poses for this diagnostic and how the design addresses and solves them. Vacuum, thermal stress and heat transfer calculations are presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reducing Dose Uncertainty for Spot-Scanning Proton Beam Therapy of Moving Tumors by Optimizing the Spot Delivery Sequence

Purpose: To develop and validate a novel delivery strategy for reducing the respiratory motion–induced dose uncertainty of spot-scanning proton therapy. Methods and Materials: The spot delivery sequence was optimized to reduce dose uncertainty. The effectiveness of the delivery sequence optimization was evaluated using measurements and patient simulation. One hundred ninety-one 2-dimensional measurements using different delivery sequences of a single-layer uniform pattern were obtained with a detector array on a 1-dimensional moving platform. Intensity modulated proton therapy plans were generated for 10 lung cancer patients, and dose uncertainties for different delivery sequences were evaluated by simulation. Results: Without delivery sequence optimization, the maximum absolute dose error can be up to 97.2% in a single measurement, whereas the optimized delivery sequence results in a maximum absolute dose error of ≤11.8%. In patient simulation, the optimized delivery sequence reduces the mean of fractional maximum absolute dose error compared with the regular delivery sequence by 3.3% to 10.6% (32.5-68.0% relative reduction) for different patients. Conclusions: Optimizing the delivery sequence can reduce dose uncertainty due to respiratory motion in spot-scanning proton therapy, assuming the 4-dimensional CT is a true representation of the patients' breathing patterns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional mapping of mineral in intact shark centra with energy dispersive x-ray diffraction

The centra of shark vertebrae consist of cartilage mineralized by a bioapatite similar to bone's carbonated hy-droxyapatite, and, without a repair mechanism analogous to remodeling in bone, these structures still survive millions of cycles of high-strain loading. The main structures of the centrum are an hourglass-shaped double cone and the intermedialia which supports the cones. Little is known about the nanostructure of shark centra, spe-cifically the relationship between bioapatite and cartilage fibers, and this study uses energy dispersive diffraction (EDD) with polychromatic synchrotron x-radiation to study the spatial organization of the mineral phase and its crystallographic texture. The unique energy-sensitive detector array at beamline 6-BM-B, the Advanced Photon Source, enables EDD to quantify the texture within each sampling volume with one exposure while constructing 3D maps via specimen translation across the sampling volume. Herein this study maps a centrum from two shark orders, a carcharhiniform and a lamniform, with different intermedialia structures. In the blue shark (Prionace glauca, Carcharhiniformes), the bioapatite's c-axes are oriented laterally within the centrum's cone walls but axially within the wide wedges of the intermedialia; the former is interpreted to resist lateral deformation, the latter to support axial loads. In the shortfin mako (Isurus oxyrinchus, Lamniformes), there is some tendency for c-axis variation with position, but the situation is unclear because one dimension of the sampling volume is consid-erably larger than the thickness and spacing of the intermedialia's radially-oriented lamellae. Because elastic modulus in collagen plus bioapatite mineralized tissues varies significantly with both volume fraction of bio-apatite and crystallographic texture, the present 3D EDD-derived maps should inform future 3D numerical models of shark centra under applied load.

59 BASIC BIOLOGICAL SCIENCES↗

Nuclear Data Sheets for A = 139

The experimental nuclear spectroscopic data for known nuclides of mass number 139 (Sn, Sb, Te, I, Xe, Cs, Ba, La, Ce, Pr, Nd, Pm, Sm, Eu, Gd, Tb, Dy) have been evaluated and presented together with adopted properties for levels and gamma rays. This evaluation represents a revision of previous one (2001Bu16) by T.W. Burrows. Since then extensive new data have become available for many A=139 nuclides although, no excited state data are yet available for {sup 139}Sn, {sup 139}Sb, {sup 139}Tb, and {sup 139}Dy. The decay schemes of {sup 139}Sn, {sup 139}Sb, {sup 139}I, {sup 139}Tb and {sup 139}Dy nuclei are not known, and those for {sup 139}Gd and {sup 139}Eu are poorly known. Particle-transfer data are available for {sup 139}Ba, {sup 139}La, {sup 139}Ce and {sup 139}Pr. Limited high-spin data are available for {sup 139}Te, {sup 139}I, {sup 139}Cs, {sup 139}Ba, {sup 139}La and {sup 139}Ce, while such data are extensive for {sup 139}Pr, {sup 139}Nd, {sup 139}Pm, {sup 139}Sm, {sup 139}Eu and {sup 139}Gd. Recent {sup 139}Pm high-spin data from two independent studies using the same reaction and similar beam energy are in conflict and could be improved using state-of-the-art large gamma-detector arrays in contrast to the smaller arrays currently used. Cases for which no new experimental information are available since the last update have undergone checking resulting in some changes in the current work, but for the most part these are taken from the previous evaluations. Thus, the present work has greatly benefited from all prior NDS evaluations (2001Bu16, 1989Bu12, 1981Pe04, 1974Gr46), but at the same time data presented herein supersede those in the earlier evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A=189

Evaluated experimental data are presented for 13 known mass 189 nuclides (Hf, Ta, W, Re, Os, Ir, Pt, Au, Hg, Tl, Pb, Bi, Po). Since the 2003Wu02 publication, structure and decay data from 25 new and primary publications have been incorporated in the current work, while adding a new 189 Hf nuclide. New data have been added for all nuclides except 189 Au and 189 Hg. Moreover, several previous datasets were modified for β-decay Q values and conversion coefficients even when no new publications appeared since 2003Wu02. In spite of large amounts of data available for A=189 nuclides, several deficiencies remain, which are pointed out below in the hope that further experimental work may improve our knowledge of structure of these nuclides. For 189 Hf and 189 Ta, ground-state half-lives, and their decay schemes are unknown. An isomer in 189 Ta has recently been established but its decay characteristics are unknown, even though several gamma rays were connected with its decay. No excited states are known in 189 W and only one in 189 Po. The decay scheme of 189 W is known poorly with most gamma rays left as unassigned. The decay schemes of 189 Au and 189 Pb g.s. suffer from incompleteness, while those for the g.s. and isomer of 189 Tl are almost absent. The decay schemes of g.s. and isomer of 189 Hg are very complex as apparent from the study by 1996Wo04. Evaluators feel that these two decay schemes could be improved with modern gamma-ray detector arrays. While several isomers are known in many of the A=189 nuclides, there is in general lack of information of level half-lives, thus limiting the knowledge of transition probabilities. High-spin structures, including SD bands in 189 Hg and 189 Tl, are known in 189 Re, 189 Ir, 189 Pt, 189 Au, 189 Hg, 189 Tl, 189 Pb and 189 Bi. Single-particle transfer data are available for 189 Re, 189 Os, and 189 Pt; and two-neutron transfer data for 189 Ir.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A=64

The evaluated experimental data are presented and evaluated for 13 known nuclides of mass 64 (Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se). For each nuclide, the best values combining all available data are recommended for spectroscopic properties. No excited states have been identified in 64 Ti, 64 As, and 64 Se. Only one excited state in 64 V as an isomer, and three in 64 Cr have been identified. Data for excited states in 64 Mn, 64 Fe, and 64 Co remain limited. 64 Ni, 64 Cu, and 64 Zn are the most studied nuclides through various reactions and decays, followed by 64 Ga and 64 Ge. In the opinion of the evaluators, there are several incomplete or discrepant aspects of the high-spin portion of the level scheme for 64 Zn above ≈5 MeV excitation which need to be resolved in further experiments using large γ-detector arrays. The decay schemes of 64 Ti β - , 64 As ε and 64 Se ε are unknown, while very little information is available for 64 V β - and 64 Cr β - . The decay schemes of 64 Mn β - , 64 Fe β - , 64 Co β - and 64Ge ε are somewhat better known, but still considered incomplete by evaluators. The decay scheme of 64 Ga ε decay is known in detail, however there is the possibility of additional levels populated above 4713 keV, as the Q(ε) value is 7171 keV. The β - , β + and ε decay modes of 64 Cu are well known, as this radionuclide is of great importance in applications, for example, as a dosimeter for neutron flux determination in nuclear reactors, and as a radiopharmaceutical for positron emission tomography (PET). This work supersedes earlier full evaluations of A=64 by 2007Si04, 1996Si12, 1991Si03, 1979Ha35 and 1974Au04.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron and gamma-ray energy reconstruction for characterization of special nuclear material

Characterization of special nuclear material may be performed using energy spectroscopy of either the neutron or gamma-ray emissions from the sample. Gamma-ray spectroscopy can be performed relatively easily using high-resolution semiconductors such as high-purity germanium. Neutron spectroscopy, by contrast, is a complex inverse problem. Here, results are presented for 252 Cf and PuBe energy spectra unfolded using a single EJ309 organic scintillator; excellent agreement is observed with the reference spectra. Neutron energy spectroscopy is also possible using a two-plane detector array, whereby time-offlight kinematics can be used. With this system, energy spectra can also be obtained as a function of position. Finally, spatial-dependent energy spectra are presented for neutron and gamma-ray sources that are in excellent agreement with expectations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Front-end ASIC for spectroscopic readout of virtual Frisch-grid CZT bar sensors

Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride (VFG CZT) detectors for gamma ray spectroscopy is presented. Corresponding to each ionizing event in the detector, the ASIC measures the amplitude and timing at the anode, the cathode and four pad sense electrodes associated with each sensor in a detector array. The ASIC is comprised of 52 channels of which there are 4 cathode channels and 48 channels which can be configured as either anode channels with a baseline of 250 mV or pad sense channels to process induced signals with a baseline of 1.2 V. With a static power dissipation of 3 mW, each channel performs low-noise charge amplification, high-order shaping, peak and timing detection along with analog storage and multiplexing. The overall channel linearity was better than ± 1% with timing resolution down to 700 ps for charges greater than 8 fC in the 3 MeV range. With a 4 × 4 array of 6 mm × 6 mm × 20 mm virtual Frisch-grid bar sensors connected and biased, an electronic resolution of ≈270 e - rms for charges up to 100 fC in the 3.2 MeV range was measured. Spectral measurements obtained with the 3D correction technique demonstrated resolutions of 1.8% FWHM at 238 keV and 0.9% FWHM at 662 keV.

3D↗

Rapid simulation of X-ray scatter measurements for threat detection via GPU-based ray-tracing

Scatter-based X-ray imaging has increased in prominence in areas ranging from cancer diagnostics to threat detection in aviation security, due largely to the development of new algorithms and components over the last decade. However, system design and algorithm development are often hindered by an inability to generate a sucient amount of accurate data. To further the development of scatter-based systems, we created a rapid X-ray scatter simulation tool built with a GPU-centric, parallel ray-tracing framework (NVIDIA OptiX). This tool models a full range of X-ray imaging components and describes 3D objects formed with heterogeneous media using polygon meshes. The scatter simulation algorithm we used is similar to the previously-described hybrid approach; however, instead of employing Monte Carlo techniques, we developed a purely analytical algorithm to sample the distribution of single-scatter events throughout the region of interest. The contribution of scattered photons to the measured signal is then calculated using the first-Born approximation. Here, the accuracy of the implemented pipeline has been validated by comparing simulated against experimental data obtained with a laboratory X-ray scattering system and phantoms of varied materials. Using a single desktop computer with an NVIDIA GTX 770 GPU, we show that the scatter signal generated by an incident fan beam and recorded by a 125 125 element detector array can be simulated in on the order of a few to tens of minutes (depending on the object extent and complexity). As a point of comparison, simulations performed via CPU-based Monte Carlo tools, such as GEANT4 (i.e., the gold standard), can take up to tens of hours to achieve comparable results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New insights into the nuclear structure in neutron-rich 112,114,115,116,117,118Pd

New level schemes of 112,114,115,116,117,118Pd are established by means of ?–?–??–?–?, ?–?–?–??–?–?–? and ?–?(0)?–?(0) measurements of prompt fission y rays from 252Cf using the Gammasphere multi-detector array. Spins/parities were assigned to levels based on ?–??–? angular correlation measurements, level systematics and decay patterns. In the even-N isotopes 112,114,116Pd, two sets of odd-parity bands were identified and extended with spins measured in each band. The odd-parity bands with large level staggerings were interpreted as disturbed chirality with less pronounced triaxial deformations in the Pd isotopes than observed in the chiral symmetry breaking 110,112Ru with maximum triaxiality. Onset of wobbling motion was identified from the sign of the signature splitting in the ? band of even–even 114Pd, and probably also in 116Pd, as first seen in the N=68N=68 isotone 112Ru. Maximal triaxiality in Ru and Pd isotopes is found to be reached for N=68N=68, 112Ru and 114Pd, 4 neutrons more than predicted in the theoretical calculations. The new data and TRS calculations allowed a systematic study of the band crossings in the even-N112,114,116Pd and odd-N115,117Pd isotopes. Now we find a new overall, more complex shape evolution than previously proposed from triaxial prolate in 110Pd via triaxial oblate in 112Pd to nearly oblate in 114,116Pd with a large change of the triaxial deformation parameter y toward nearly oblate in the (pi g 9/2)2 alignment in 114,115,116,117,118Pd, and triaxial-prolate–triaxial-oblate shape coexisting bands in 115Pd.

112,114,115,116,117,118Pd↗

Excited states in semi-magic 82 Ge populated in the βn-decay of 83 Ga

For this work, the βn and β-decay of the neutron-rich 83 Ga isotopes produced in proton-induced fission of 238 U were studied at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory using on-line mass separation and the hybrid-3Hen neutron-γ detector array. Excited states in semi-magic 82 Ge populated in βn decay of 83 Ga were identified using neutron-γ coincidences. The measured relative population of excited states in 82 Ge is compared with a βn emission model, where the neutron emission model combines the strength distribution obtained from the shell-model calculations with the statistical Hauser-Feshbach model.

3HEN↗