Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum computing in nuclear physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

An algorithm for efficient metal artifact reductions in permanent seed implants

Purpose: In permanent seed implants, 60 to more than 100 small metal capsules are inserted in the prostate, creating artifacts in x-ray computed tomography (CT) imaging. The goal of this work is to develop an automatic method for metal artifact reduction (MAR) from small objects such as brachytherapy seeds for clinical applications. Methods: The approach for MAR is based on the interpolation of missing projections by directly using raw helical CT data (sinogram). First, an initial image is reconstructed from the raw CT data. Then, the metal objects segmented from the reconstructed image are reprojected back into the sinogram space to produce a metal-only sinogram. The Steger method is used to determine precisely the position and edges of the seed traces in the raw CT data. By combining the use of Steger detection and reprojections, the missing projections are detected and replaced by interpolation of non-missing neighboring projections. Results: In both phantom experiments and patient studies, the missing projections have been detected successfully and the artifacts caused by metallic objects have been substantially reduced. The performance of the algorithm has been quantified by comparing the uniformity between the uncorrected and the corrected phantom images. The results of the artifact reduction algorithm are indistinguishable from the true background value. Conclusions: An efficient algorithm for MAR in seed brachytherapy was developed. The test results obtained using raw helical CT data for both phantom and clinical cases have demonstrated that the proposed MAR method is capable of accurately detecting and correcting artifacts caused by a large number of very small metal objects (seeds) in sinogram space. This should enable a more accurate use of advanced brachytherapy dose calculations, such as Monte Carlo simulations.

60 APPLIED LIFE SCIENCES↗

Simultaneous segmentation and reconstruction: A level set method approach for limited view computed tomography

Purpose: An iterative tomographic reconstruction algorithm that simultaneously segments and reconstructs the reconstruction domain is proposed and applied to tomographic reconstructions from a sparse number of projection images. Methods: The proposed algorithm uses a two-phase level set method segmentation in conjunction with an iterative tomographic reconstruction to achieve simultaneous segmentation and reconstruction. The simultaneous segmentation and reconstruction is achieved by alternating between level set function evolutions and per-region intensity value updates. To deal with the limited number of projections, a priori information about the reconstruction is enforced via penalized likelihood function. Specifically, smooth function within each region (piecewise smooth function) and bounded function intensity values for each region are assumed. Such a priori information is formulated into a quadratic objective function with linear bound constraints. The level set function evolutions are achieved by artificially time evolving the level set function in the negative gradient direction; the intensity value updates are achieved by using the gradient projection conjugate gradient algorithm. Results: The proposed simultaneous segmentation and reconstruction results were compared to ''conventional'' iterative reconstruction (with no segmentation), iterative reconstruction followed by segmentation, and filtered backprojection. Improvements of 6%-13% in the normalized root mean square error were observed when the proposed algorithm was applied to simulated projections of a numerical phantom and to real fan-beam projections of the Catphan phantom, both of which did not satisfy the a priori assumptions. Conclusions: The proposed simultaneous segmentation and reconstruction resulted in improved reconstruction image quality. The algorithm correctly segments the reconstruction space into regions, preserves sharp edges between different regions, and smoothes the noise within each region. The proposed algorithm framework has the flexibility to be adapted to different a priori constraints while maintaining the benefits achieved by the simultaneous segmentation and reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Large Hyperfine Coupling Arising from Pseudo- 2 S Ground States in a Series of Lutetium(II) Metallocene Complexes

The synthesis of molecules with strong coupling between electronic and nuclear spins represents an important challenge in molecular quantum information science. Here, we report the synthesis and characterization of the divalent lutetium metallocene complexes Lu(Cp Me 5 )(Cp iPr 5 ) (Cp Me 5 = pentamethylcyclopentadienyl; Cp iPr 5 = pentaisopropylcyclopentadienyl), Lu(Cp iPr 4 Et ) 2 (Cp iPr 4 Et = ethyltetraisopropylcyclopentadienyl), and Lu(Cp iPr 4 ) 2 (Cp iPr 4 = tetraisopropylcyclopentadienyl). The molecular structures of these complexes, as determined through singlecrystal X-ray diffraction, feature a common bent sandwich geometry, with average Cp–Lu–Cp angles ranging from 159.9° to 152.6°. Analysis of continuous-wave electron paramagnetic resonance (EPR) spectra for the complexes reveals nearly isotropic g tensors with only a slight deviation from that of a free electron. Moreover, an extremely large splitting of the eight-line spectra indicates the presence of strong hyperfine coupling, and simulations provide isotropic hyperfine coupling constants of A iso = 4.38, 4.30, and 4.17 GHz across the series, where the value of A iso is found to decrease as the Cp–Lu–Cp angle becomes more acute. Notably, these values are the largest yet observed for any lanthanide complex. Moreover, EPR and computational analysis show that the large values of A iso stem from large s-orbital character up to 41.2% in the corresponding singly occupied molecular orbitals. To our knowledge, this degree of s-character in a molecular orbital is the largest yet reported for an open-shell isolable complex. These results outline a general strategy toward the isolation of paramagnetic molecules with strong hyperfine coupling and highly isotropic doublet electronic ground states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A New On-the-Fly Sampling Method for Incoherent Inelastic Thermal Neutron Scattering Data in MCNP6

At thermal energies, the scattering of neutrons in a system is complicated by the comparable velocities of the neutron and target, resulting in competing upscattering and downscattering events. The neutron wavelength is also similar in size to the target's interatomic spacing making the scattering process a quantum mechanical problem. Because of the complicated nature of scattering at low energies, the thermal data files in ACE format used in continuous-energy Monte Carlo codes are quite large { on the order of megabytes for a single temperature and material. In this paper, a new storage and sampling method is introduced that is orders of magnitude less in size and is used to sample scattering parameters at any temperature on-the-fly. In addition to the reduction in storage, the need to pre-generate thermal scattering data tables at fine temperatures has been eliminated. This is advantageous for multiphysics simulations which may involve temperatures not known in advance. A new module was written for MCNP6 that bypasses the current S(α,β) table lookup in favor of the new format. The new on-the-fly sampling method was tested for graphite for two benchmark problems at ten temperatures: 1) an eigenvalue test with a fuel compact of uranium oxycarbide fuel homogenized into a graphite matrix, 2) a surface current test with a \broomstick" problem with a monoenergetic point source. The largest eigenvalue difference was 152pcm for T= 1200K. For the temperatures and incident energies chosen for the broomstick problem, the secondary neutron spectrum showed good agreement with the traditional S(α,β) sampling method. These preliminary results show that sampling thermal scattering data on-the-fly is a viable option to eliminate both the storage burden of keeping thermal data at discrete temperatures and the need to know temperatures before simulation runtime.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dark Matter Searches with Cherenkov Telescopes: Nearby Dwarf Galaxies or Local Galaxy Clusters?

In this paper, we compare dwarf galaxies and galaxy clusters in order to elucidate which object class is the best target for gamma-ray DM searches with imaging atmospheric Cherenkov telescopes (IACTs). We have built a mixed dwarfs+clusters sample containing some of the most promising nearby dwarf galaxies (Draco, Ursa Minor, Wilman 1 and Segue 1) and local galaxy clusters (Perseus, Coma, Ophiuchus, Virgo, Fornax, NGC 5813 and NGC 5846), and then compute their DM annihilation flux profiles by making use of the latest modeling of their DM density profiles. We also include in our calculations the effect of DM substructure. Willman 1 appears as the best candidate in the sample. However, its mass modeling is still rather uncertain, so probably other candidates with less uncertainties and quite similar fluxes, namely Ursa Minor and Segue 1, might be better options. As for galaxy clusters, Virgo represents the one with the highest flux. However, its large spatial extension can be a serious handicap for IACT observations and posterior data analysis. Yet, other local galaxy cluster candidates with more moderate emission regions, such as Perseus, may represent good alternatives. After comparing dwarfs and clusters, we found that the former exhibit annihilation flux profiles that, at the center, are roughly one order of magnitude higher than those of clusters, although galaxy clusters can yield similar, or even higher, integrated fluxes for the whole object once substructure is taken into account. Even when any of these objects are strictly point-like according to the properties of their annihilation signals, we conclude that dwarf galaxies are best suited for observational strategies based on the search of point-like sources, while galaxy clusters represent best targets for analyses that can deal with rather extended emissions. Finally, we study the detection prospects for present and future IACTs in the framework of the constrained minimal supersymmetric standard model. We find that the level of the annihilation flux from these targets is below the sensitivities of current IACTs and the future CTA.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental and Theoretical Confirmation of Covalent Bonding in α‐Pu

Plutonium's radioactivity provides functionality for nuclear batteries, nuclear reactors, etc., but its complex electronic properties harbor strongly correlated behavior giving rise to a host of interesting phenomena including the presence of a ca. 25% volume collapse between δ-Pu and α-Pu. The complex bonding environments of the ground state allotrope, α-Pu, serve as a unique testing ground for new computational and experimental approaches within the Pu science community. For the first time, a combination of novel ansatzes is used in all-electron density functional theory (DFT) and pair distribution functions (PDF) obtained from high-Q X-ray diffraction to study the bonding behavior in α-Pu. This first experimental and theoretical co-informed description of local bonding behavior for α-Pu reveals covalent bonds, which is a topic that remains of interest in this allotrope. The covalent bonding present at the atomistic level accounts for several of α-Pu's macropscopic properties (e.g., Poisson's ratio) that in turn explains its physical functionalities relative to other allotropic phases like δ-Pu.

36 MATERIALS SCIENCE↗

Physical evaluation of a needle photostimulable phosphor based CR mammography system

Purpose: Needle phosphor based computed radiography (CR) systems promise improved image quality compared to powder phosphor based CR units for x-ray screening mammography. This paper compares the imaging performance of needle CR cassettes, powder based CR cassettes and a well established amorphous selenium (a-Se) based flat panel based mammography system, using consistent beam qualities. Methods: Detector performance was assessed using modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE). Mammography system performance was assessed against levels from the European Guidelines, including threshold gold thickness (c-d), relative signal difference to noise (SdNR) and mean glandular dose, for automatic exposure control settings suggested by the manufacturers. The needle based Agfa HM5.0 CR detector was compared against the single sided readout Agfa MM3.0R and dual sided readout Fuji Profect CS powder CR plates using a 28 kV Mo/Rh spectrum, while a 28 kV W/Rh spectrum was used to compare the Agfa HM5.0 against the Siemens MAMMOMAT Inspiration a-Se based system. Results: MTF at 5 mm{sup -1} was 0.16 and 0.24 for the needle CR detector in the fast and slow scan directions, respectively, indicating a slight improvement ({approx}20%) over the two powder CR systems but remained 50% lower than the result at 5 mm{sup -1} for the a-Se detector ({approx}0.55). Structured screen noise was lower for the needle phosphor compared to the powder plates. CR system gain, estimated from the measured absorption fraction and NNPS results, was 6.3 for the (single sided) needle phosphor and 5.1 and 7.2 for the single sided and dual sided powder phosphor systems. Peak DQE at {approx}100 {mu}Gy was 0.47 for the needle system compared to peak DQE figures of 0.33 and 0.46 for the single sided readout powder plates and dual sided readout plates. The high frequency DQE (at 5 mm{sup -1}) was 0.19 for the needle CR plates, a factor of approximately 3 greater than for the powder CR plates. At 28 kV W/Rh, 2 mm Al, peak DQE for the needle CR system was 0.45 against a value of 0.50 for the a-Se detector. The needle CR detector reached the Acceptable limit for 0.1 mm details in the European Guidelines at a mean glandular dose (MGD) of approximately 1.31 mGy imaged at 28 kV Mo/Rh, compared to figures of 2.19 and 1.43 mGy for the single sided and dual sided readout powder CR systems. The a-Se detector could reach the limit at 0.65 mGy using a 28 kV W/Rh spectrum, while the needle CR system required 1.09 mGy for the same spectrum. Conclusions: Imaging performance for the needle CR phosphor technology, characterized using MTF and DQE and threshold gold thickness demonstrated a clear improvement compared to both single and dual sided reading powder phosphor based CR systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of space weather into space situational awareness

Rapid assessment of space weather effects on satellites is a critical step in anomaly resolution and satellite threat assessment. That step, however, is often hindered by a number of factors including timely collection and delivery of space weather data and the inherent com plexity of space weather information. As part of a larger, integrated space situational awareness program, Los Alamos National Laboratory has developed prototype operational space weather tools that run in real time and present operators with customized, user-specific information. The Dynamic Radiation Environment Assimilation Model (DREAM) focuses on the penetrating radiation environment from natural or nuclear-produced radiation belts. The penetrating radiation environment is highly dynamic and highly orbit-dependent. Operators often must rely only on line plots of 2 MeV electron flux from the NOAA geosynchronous GOES satellites which is then assumed to be representative of the environment at the satellite of interest. DREAM uses data assimilation to produce a global, real-time, energy dependent specification. User tools are built around a distributed service oriented architecture (SOA) which will allow operators to select any satellite from the space catalog and examine the environment for that specific satellite and time of interest. Depending on the application operators may need to examine instantaneous dose rates and/or dose accumulated over various lengths of time. Further, different energy thresholds can be selected depending on the shielding on the satellite or instrument of interest. In order to rapidly assess the probability that space weather was the cause of anomalous operations, the current conditions can be compared against the historical distribution of radiation levels for that orbit. In the simplest operation a user would select a satellite and time of interest and immediately see if the environmental conditions were typical, elevated, or extreme based on how often those conditions occur in that orbit. This allows users to rapidly rule in or out environmental causes of anomalies. The same user interface can also allow users to drill down for more detailed quantitative information. DREAM can be run either from a distributed web-based user interface or as a stand-alone application for secure operations. In this paper we discuss the underlying structure of the DREAM model and demonstrate the user interface that we have developed . We also present some prototype data products and user interfaces for DREAM and discuss how space environment information can be seamlessly integrated into operational SSA systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cone beam x-ray luminescence computed tomography: A feasibility study

Purpose: The appearance of x-ray luminescence computed tomography (XLCT) opens new possibilities to perform molecular imaging by x ray. In the previous XLCT system, the sample was irradiated by a sequence of narrow x-ray beams and the x-ray luminescence was measured by a highly sensitive charge coupled device (CCD) camera. This resulted in a relatively long sampling time and relatively low utilization of the x-ray beam. In this paper, a novel cone beam x-ray luminescence computed tomography strategy is proposed, which can fully utilize the x-ray dose and shorten the scanning time. The imaging model and reconstruction method are described. The validity of the imaging strategy has been studied in this paper. Methods: In the cone beam XLCT system, the cone beam x ray was adopted to illuminate the sample and a highly sensitive CCD camera was utilized to acquire luminescent photons emitted from the sample. Photons scattering in biological tissues makes it an ill-posed problem to reconstruct the 3D distribution of the x-ray luminescent sample in the cone beam XLCT. In order to overcome this issue, the authors used the diffusion approximation model to describe the photon propagation in tissues, and employed the sparse regularization method for reconstruction. An incomplete variables truncated conjugate gradient method and permissible region strategy were used for reconstruction. Meanwhile, traditional x-ray CT imaging could also be performed in this system. The x-ray attenuation effect has been considered in their imaging model, which is helpful in improving the reconstruction accuracy. Results: First, simulation experiments with cylinder phantoms were carried out to illustrate the validity of the proposed compensated method. The experimental results showed that the location error of the compensated algorithm was smaller than that of the uncompensated method. The permissible region strategy was applied and reduced the reconstruction error to less than 2 mm. The robustness and stability were then evaluated from different view numbers, different regularization parameters, different measurement noise levels, and optical parameters mismatch. The reconstruction results showed that the settings had a small effect on the reconstruction. The nonhomogeneous phantom simulation was also carried out to simulate a more complex experimental situation and evaluated their proposed method. Second, the physical cylinder phantom experiments further showed similar results in their prototype XLCT system. With the discussion of the above experiments, it was shown that the proposed method is feasible to the general case and actual experiments. Conclusions: Utilizing numerical simulation and physical experiments, the authors demonstrated the validity of the new cone beam XLCT method. Furthermore, compared with the previous narrow beam XLCT, the cone beam XLCT could more fully utilize the x-ray dose and the scanning time would be shortened greatly. The study of both simulation experiments and physical phantom experiments indicated that the proposed method was feasible to the general case and actual experiments.

60 APPLIED LIFE SCIENCES↗

An iterative method for tomographic x-ray perfusion estimation in a decomposition model-based approach

Purpose: X-ray based tomographic blood perfusion imaging requires recovery of contrast time-attenuation-curves from dynamic projection data. When using slowly rotating imaging systems, this task is challenging due to nonsimultaneous projection acquisition. A dynamic reconstruction method is proposed that aims at compensating the lack of simultaneously acquired information by incorporating prior knowledge about the expected temporal contrast dynamics. Methods: A decomposition model using temporal basis functions to approximate time-attenuation-curves is integrated into an iterative tomographic reconstruction method. The computationally efficient implementation of the proposed approach makes use of standard forward-projections and backprojections, as well as scalar products in image space. The critical issue of projection noise propagation is tackled by the application of regularization which is realized by the early stopping of iteration cycles and by the proper selection of smooth temporal basis functions. The performance of the proposed dynamic reconstruction approach is evaluated in a simulation study concerning various aspects: Noise propagation and regularization, specification of the temporal model, and type of acquisition mode. Results: The evaluation based on dynamic phantom data indicates that tomographic recovery of contrast time-attenuation-curves in tissue can be achieved with an average range of accuracy of {approx}2% (with respect to dynamic peak attenuation) under ideal noise-free conditions. The relative estimation error for arterial time-attenuation-curves is in the range of 8%, which is due to faster contrast dynamics in the artery. In general, performance depends on the level of acquired information contained in the projection data, which is mainly influenced by the type of rotational acquisition mode; restrictions in angular range and speed can lead to limited accuracy. The analysis of propagated projection noise in a statistical bias-variance framework reveals relative noise levels in estimated time-attenuation-curves of 3%-4% in tissue regions and below 1% in vessels when using optimized settings for regularization. Here, the effect of noise suppression depends on the interrelation between the number of iteration cycles and the constraints imposed by the temporal decomposition model. Conclusions: For usage with slowly rotating imaging systems, the presented model-based iterative dynamic reconstruction method is capable of recovering contrast time-attenuation-curves related to tissue perfusion. The proposed regularization framework is an effective means to limit the impact of projection noise, which is a factor dominating estimation accuracy in tissue regions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Purification of Zirconium Tetrachloride from UNF Cladding

The overarching objective of this project was to design and demonstrate (laboratory scale) a sublimation-based purification protocol to obtain pure zirconium chloride (ZrCl 4 ) from impure feeds derived from the direct chlorination of Zircaloy cladding materials. To achieve this objective the following goals were identified. (1) Design, construct and test an apparatus capable of subliming and purifying ZrCl 4 at room pressure and temperatures between 600 and 700K (sublimation point of ZrCl 4 606 K). (2) Investigate reactions that may be used to chemically alter the makeup of the impure ZrCl 4 feed materials to enhance their removal from ZrCl 4 in the sublimation-purification process. (3) Computationally model the reactions of metal chlorides in the gas phase under sublimation conditions (1 atm, 600 K) to determine if oligomers are formed and, if formed, how they would influence sublimation-based purification strategies. All experimental investigations performed as part of this project used stable (non-radioactive) compounds and materials as surrogates for the impure ZrCl 4 feedstocks that would be derived from the direct chlorination of Zircaloy claddings from spent nuclear fuel rods. No radiologically active materials were used at any time in this project. The impure ZrCl 4 feedstocks used in this study were derived from the direct chlorination of virgin Zircaloy claddings (Zirc-2, -4 and high Nb). The main goals of the project have been achieved during the three year period of this NEUP sponsored project. The impurities of greatest concern in the feedstocks were identified as the chloride salts of the alloying metals originally found in Zircaloy (Fe, Nb) and radiological contaminants (Cs, Sr, and Sb). A series of prototype sublimation apparatuses and heating arrangements were designed, constructed and tested. A general batch-sublimator design was identified and a 1.0 kg batch sublimator/oven system was fabricated from glass. Purification protocols developed on small scale runs were found to scale to 1.0 kg batches without problem. Purification factor ranges (PFs: wt% final / wt% initial ) for the impurity chlorides identified above have been measured: Fe (40 – 500); Nb (10 – 70); Cs (520 – 5000); Sr (250 – 1900); Sb (220 – 2300). Removal of iron is sensitive to the partial pressure of hydrogen (in nitrogen) flowing through the system. Lower PFs are obtained when the hydrogen partial pressure is lower. Lower flows are required to raise the iron PF. Removal of niobium is very sensitive to the endpoint determination of the forerun. When judged properly (color change yellow to white in sublimate) reasonable PFs (500) can be achieved. However, as discussed in the conclusions section, endpoint determination can be difficult and significantly lower PFs may be obtained when the endpoint is not correctly identified. Several methods of obtaining quantitative cesium, strontium and antimony PFs were investigated, the best being ICP-MS. The results reported here reflect very limited access to and ICP-MS instrument during the course of this project. It should be noted that, while significantly reduced amounts of antimony are observed in the product, antimony is also found in the exhaust trap after the condenser. Quantum chemical computational modeling studies of the reactions of metal chlorides in the gas phase provided important information about a chemical transport mechanism that could defeat sublimation-based purification strategies. Many metal chlorides are known to oligomerize in the gas phase to reduce their coordinative unsaturation. Dimerization of ZrCl 4 with iron or niobium chlorides would provide a mechanism by which both metal impurities could be carried over with the product during sublimation of the bulk material. Computational modeling conclusively showed that under sublimation conditions in the gas phase, dimerization reactions are not favored thermodynamically due to a significant entropic penalty for the reaction. Therefore, consistent with experimental observations, sublimation-based purification strategies remain viable. The experimental part of the report concludes with a short discussion of the issues that still remain in developing a technologically relevant Zircaloy recycling strategy. The final section of the report is a summary of the quantum chemical investigation of the reactions of metal chlorides in the gas phase under sublimation conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Laboratory and Astrophysical Probes of Physics Beyond the Standard Model (Final Technical Report)

The first of these directions centers on new ideas in dark matter detection. As experimental scrutiny narrows the window for new physics at the weak scale, it has become apparent that the solution to the dark matter mystery may not reside there. Theoretical developments such as the hidden sector/valley paradigm have, at the same time, shown that compelling theories of dark matter reside below the weak scale. Searching for dark matter at lower mass scales requires looking beyond the current paradigm of dark matter direct detection based on nuclear recoils. It is the goal of this project to provide new ideas to guide the experimental program looking for light dark matter. I am actively proposing ideas for detecting dark matter as light as a meV, well beyond the current focus of GeV-TeV scale dark matter. Some of the ideas I have proposed, such as superconducting, superfluid, and polar material targets, are actively being developed into experiments. My group will provide the relevant calculations to determine dark matter reach, providing crucial input to experiment on which targets should be developed. We will also provide an effective field theory framework to understand which types of experiments are most sensitive to each interaction type. The second of these directions is on probes of dark matter substructure as a mean to constrain, or observe, models of dark matter. The standard ΛCDM paradigm assumes that the dark matter density perturbations are adiabatic, scale invariant, and produced during inflation. However, many standard models of dark matter will produce modifications of this prediction, such as axion models with symmetry broken below the inflationary scale. Remarkably, we have limited direct measurements of the dark matter clumpiness at mass scales below dwarf galaxies. This allows for the possibility of observing modifications from vanilla ΛCDM due to particle dynamics. In many cases, simulations of dark matter structure in the presence of non-scale invariant fluctu- ations are understudied or completely lacking. I plan to develop both theoretical predictions for small scale structure in models with additional matter power on small scales, as well as observa- tional probes of small scale halos or clumps. One idea I have been recently focused on is pulsar timing, though my group will pursue a variety of lensing and astrometric probes. Lastly, the most risky direction involves spacetime fluctuations from quantum gravity. I showed that if one assumes that metric fluctuations in the Minkowski vacuum, at a surface separating a region in and out of causal contact (which we call a “horizon”), are determined by standard thermodynamic considerations at horizon, these metric fluctuations are large enough to observe in an interferometer with similar sensitivity to LIGO. In a follow-up paper we showed that these assumption holds for the vacuum in AdS/CFT. In future work, I plan to connect this work to recent soft graviton results, to frame this work in a concrete Randall-Sundrum model, and to work out concrete phenomenological predictions from the model. This work unquestionably takes a less trodden path, and works well as part of a well-rounded portfolio of less and more risky ideas. Particle physics is currently at a juncture which requires bold exploration of qualitatively new directions. This proposal outlines some of my plans over the coming years in these directions, leaving room also for surprises.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation Study of Near-Surface Coupling of Nuclear Devices vs. Equivalent High-Explosive Charges

A computational study was performed to examine the differences in near-surface ground-waves and air-blast waves generated by high-explosive energy sources and those generated by much higher energy - density low - yield nuclear sources. The study examined the effect of explosive-source emplacement (i.e., height-of-burst, HOB, or depth-of-burial, DOB) over a range from depths of -35m to heights of 20m, for explosions with an explosive yield of 1-kt . The chemical explosive was modeled by a JWL equation-of-state model for a ~14m diameter sphere of ANFO (~1,200,000kg – 1 k t equivalent yield ), and the high-energy-density source was modeled as a one tonne (1000 kg) plasma of ‘Iron-gas’ (utilizing LLNL’s tabular equation-of-state database, LEOS) in a 2m diameter sphere, with a total internal-energy content equivalent to 1 k t . A consistent equivalent-yield coupling-factor approach was developed to compare the behavior of the two sources. The results indicate that the equivalent-yield coupling-factor for air-blasts from 1 k t ANFO explosions varies monotonically and continuously from a nearly perfec t reflected wave off of the ground surface for a HOB ≈ 20m, to a coupling factor of nearly zero at DOB ≈ -25m. The nuclear air - blast coupling curve, on the other hand, remained nearly equal to a perfectly reflected wave all the way down to HOB’s very near zero, and then quickly dropped to a value near zero for explosions with a DOB ≈ -10m. The near - surface ground - wave traveling horizontally out from the explosive source region to distances of 100’s of meters exhibited equivalent - yield coupling - factors t hat varied nearly linearly with HOB/DOB for the simulated ANFO explosive source, going from a value near zero at HOB ≈ 5m to nearly one at DOB ≈ -25m. The nuclear-source generated near-surface ground wave coupling-factor remained near zero for almost all HOB’s greater than zero, and then appeared to vary nearly - linearly with depth-of-burial until it reached a value of one at a DOB between 15m and 20m. These simulations confirm the expected result that the variation of coupling to the ground, or the air, change s much more rapidly with emplacement location for a high-energy-density (i.e., nuclear-like) explosive source than it does for relatively low - energy - density chemical explosive sources. The Energy Partitioning, Energy Coupling (EPEC) platform at LLNL utilizes laser energy from one quad (i.e. 4-laser beams) of the 192 - beam NIF Laser bank to deliver ~10kJ of energy to 1mg of silver in a hohlraum creating an effective small-explosive ‘source’ with an energy density comparable to those in low-yield nuclear devices. Such experiments have the potential to provide direct experimental confirmation of the simulation results obtained in this study, at a physical scale (and time-scale) which is a factor of 1000 smaller than the spatial- or temporal-scales typically encountered when dealing with nuclear explosions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Resolution enhancement of lung 4D-CT data using multiscale interphase iterative nonlocal means

Purpose: Four-dimensional computer tomography (4D-CT) has been widely used in lung cancer radiotherapy due to its capability in providing important tumor motion information. However, the prolonged scanning duration required by 4D-CT causes considerable increase in radiation dose. To minimize the radiation-related health risk, radiation dose is often reduced at the expense of interslice spatial resolution. However, inadequate resolution in 4D-CT causes artifacts and increases uncertainty in tumor localization, which eventually results in extra damages of healthy tissues during radiotherapy. In this paper, the authors propose a novel postprocessing algorithm to enhance the resolution of lung 4D-CT data. Methods: The authors' premise is that anatomical information missing in one phase can be recovered from the complementary information embedded in other phases. The authors employ a patch-based mechanism to propagate information across phases for the reconstruction of intermediate slices in the longitudinal direction, where resolution is normally the lowest. Specifically, the structurally matching and spatially nearby patches are combined for reconstruction of each patch. For greater sensitivity to anatomical details, the authors employ a quad-tree technique to adaptively partition the image for more fine-grained refinement. The authors further devise an iterative strategy for significant enhancement of anatomical details. Results: The authors evaluated their algorithm using a publicly available lung data that consist of 10 4D-CT cases. The authors' algorithm gives very promising results with significantly enhanced image structures and much less artifacts. Quantitative analysis shows that the authors' algorithm increases peak signal-to-noise ratio by 3-4 dB and the structural similarity index by 3%-5% when compared with the standard interpolation-based algorithms. Conclusions: The authors have developed a new algorithm to improve the resolution of 4D-CT. It outperforms the conventional interpolation-based approaches by producing images with the markedly improved structural clarity and greatly reduced artifacts.

60 APPLIED LIFE SCIENCES↗

Investigation of a breathing surrogate prediction algorithm for prospective pulmonary gating

Purpose: A major challenge of four dimensional computed tomography (4DCT) in treatment planning and delivery has been the lack of respiration amplitude and phase reproducibility during image acquisition. The implementation of a prospective gating algorithm would ensure that images would be acquired only during user-specified breathing phases. This study describes the development and testing of an autoregressive moving average (ARMA) model for human respiratory phase prediction under quiet respiration conditions. Methods: A total of 47 4DCT patient datasets and synchronized respiration records was utilized in this study. Three datasets were used in model development and were removed from further evaluation of the ARMA model. The remaining 44 patient datasets were evaluated with the ARMA model for prediction time steps from 50 to 1000 ms in increments of 50 and 100 ms. Thirty-five of these datasets were further used to provide a comparison between the proposed ARMA model and a commercial algorithm with a prediction time step of 240 ms. Results: The optimal number of parameters for the ARMA model was based on three datasets reserved for model development. Prediction error was found to increase as the prediction time step increased. The minimum prediction time step required for prospective gating was selected to be half of the gantry rotation period. The maximum prediction time step with a conservative 95% confidence criterion was found to be 0.3 s. The ARMA model predicted peak inhalation and peak exhalation phases significantly better than the commercial algorithm. Furthermore, the commercial algorithm had numerous instances of missed breath cycles and falsely predicted breath cycles, while the proposed model did not have these errors. Conclusions: An ARMA model has been successfully applied to predict human respiratory phase occurrence. For a typical CT scanner gantry rotation period of 0.4 s (0.2 s prediction time step), the absolute error was relatively small, 0.06{+-}0.02 s at peak inhalation and 0.05{+-}0.04 s at peak exhalation. The application of the ARMA model for prospective pulmonary gating has been demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

“Plug-and-Play” potentials: Investigating quantum effects in (H{sub 2}){sub 2}–Li{sup +}–benzene

Quantum and anharmonic effects are investigated in (H{sub 2}){sub 2}–Li{sup +}–benzene, a model for hydrogen adsorption in metal-organic frameworks and carbon-based materials, using rigid-body diffusion Monte Carlo (RBDMC) simulations. The potential-energy surface (PES) is calculated as a modified Shepard interpolation of M05-2X/6-311+G(2df,p) electronic structure data. The RBDMC simulations yield zero-point energies (ZPE) and probability density histograms that describe the ground-state nuclear wavefunction. Binding a second H{sub 2} molecule to the H{sub 2}–Li{sup +}–benzene complex increases the ZPE of the system by 5.6 kJ mol{sup −1} to 17.6 kJ mol{sup −1}. This ZPE is 42% of the total electronic binding energy of (H{sub 2}){sub 2}–Li{sup +}–benzene and cannot be neglected. Our best estimate of the 0 K binding enthalpy of the second H{sub 2} to H{sub 2}–Li{sup +}–benzene is 7.7 kJ mol{sup −1}, compared to 12.4 kJ mol{sup −1} for the first H{sub 2} molecule. Anharmonicity is found to be even more important when a second (and subsequent) H{sub 2} molecule is adsorbed; use of harmonic ZPEs results in significant error in the 0 K binding enthalpy. Probability density histograms reveal that the two H{sub 2} molecules are found at larger distance from the Li{sup +} ion and are more confined in the θ coordinate than in H{sub 2}–Li{sup +}–benzene. They also show that both H{sub 2} molecules are delocalized in the azimuthal coordinate, ϕ. That is, adding a second H{sub 2} molecule is insufficient to localize the wavefunction in ϕ. Two fragment-based (H{sub 2}){sub 2}–Li{sup +}–benzene PESs are developed. These use a modified Shepard interpolation for the Li{sup +}–benzene and H{sub 2}–Li{sup +}–benzene fragments, and either modified Shepard interpolation or a cubic spline to model the H{sub 2}–H{sub 2} interaction. Because of the neglect of three-body H{sub 2}, H{sub 2}, Li{sup +} terms, both fragment PESs lead to overbinding of the second H{sub 2} molecule by 1.5 kJ mol{sup −1}. Probability density histograms, however, indicate that the wavefunctions for the two H{sub 2} molecules are effectively identical on the “full” and fragment PESs. This suggests that the 1.5 kJ mol{sup −1} error is systematic over the regions of configuration space explored by our simulations. Notwithstanding this, modified Shepard interpolation of the weak H{sub 2}–H{sub 2} interaction is problematic and we obtain more accurate results, at considerably lower computational cost, using a cubic spline interpolation. Indeed, the ZPE of the fragment-with-spline PES is identical, within error, to the ZPE of the full PES. This fragmentation scheme therefore provides an accurate and inexpensive method to study higher hydrogen loading in this and similar systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A fully 3D approach for metal artifact reduction in computed tomography

Purpose: In computed tomography imaging metal objects in the region of interest introduce inconsistencies during data acquisition. Reconstructing these data leads to an image in spatial domain including star-shaped or stripe-like artifacts. In order to enhance the quality of the resulting image the influence of the metal objects can be reduced. Here, a metal artifact reduction (MAR) approach is proposed that is based on a recomputation of the inconsistent projection data using a fully three-dimensional Fourier-based interpolation. The success of the projection space restoration depends sensitively on a sensible continuation of neighboring structures into the recomputed area. Fortunately, structural information of the entire data is inherently included in the Fourier space of the data. This can be used for a reasonable recomputation of the inconsistent projection data. Methods: The key step of the proposed MAR strategy is the recomputation of the inconsistent projection data based on an interpolation using nonequispaced fast Fourier transforms (NFFT). The NFFT interpolation can be applied in arbitrary dimension. The approach overcomes the problem of adequate neighborhood definitions on irregular grids, since this is inherently given through the usage of higher dimensional Fourier transforms. Here, applications up to the third interpolation dimension are presented and validated. Furthermore, prior knowledge may be included by an appropriate damping of the transform during the interpolation step. This MAR method is applicable on each angular view of a detector row, on two-dimensional projection data as well as on three-dimensional projection data, e.g., a set of sequential acquisitions at different spatial positions, projection data of a spiral acquisition, or cone-beam projection data. Results: Results of the novel MAR scheme based on one-, two-, and three-dimensional NFFT interpolations are presented. All results are compared in projection data space and spatial domain with the well-known one-dimensional linear interpolation strategy. Conclusions: In conclusion, it is recommended to include as much spatial information into the recomputation step as possible. This is realized by increasing the dimension of the NFFT. The resulting image quality can be enhanced considerably.

60 APPLIED LIFE SCIENCES↗

Iron(III)–Oxo Cluster Chemistry with Dimethylarsinate Ligands: Structures, Magnetic Properties, and Computational Studies

A program has been initiated to develop Fe III /oxo cluster chemistry with the ‘pseudo-carboxylate’ ligand dimethylarsinate (Me 2 AsO 2 - ) for comparison with the well investigated Fe III /oxo/carboxylate cluster area. The synthesis and characterization of three polynuclear Fe III complexes are reported, [Fe 12 O 4 (O 2 C t Bu) 8 (O 2 AsMe 2 ) 17 (H 2 O) 3 ]Cl 3 (1), Na 2 [Fe 12 Na 2 O 4 (O 2 AsMe 2 ) 20 (NO 3 ) 6 (Me 2 AsO 2 H) 2 (H 2 O) 4 ](NO 3 ) 6 (2) and [Fe 3 (O 2 AsMe 2 ) 6 (Me 2 AsO 2 H) 2 (hqn) 2 ](NO 3 ) (3), where hqn is 8-hydroxyquinoline. The Fe 12 core of 1 is a type never previously encountered in Fe III carboxylate chemistry, consisting of two Fe 6 units each of which comprises two {Fe 3 (μ 3 -O 2- )} units bridged by three Me 2 AsO 2 - groups and linked into an Fe 12 loop structure by two anti-anti η 1 :η 1 :μ Me 2 AsO 2 - groups, a bridging mode extremely rare with carboxylates. 2 also consists of two Fe 6 units, differing in their ligation from those in 1, and this time linked together into a linear structure by a central {Na 2 (NO 3 ) 2 } bridging unit. 3 is a linear Fe 3 complex with no monoatomic bridges between Fe III ions, a very rare situation in Fe III chemistry with any ligands, and unprecedented in Fe carboxylate chemistry. The distinct differences observed in arsinate vs carboxylate ligation modes are rationalized largely based on the greater basicity of the former vs the latter. Variable-temperature dc and ac magnetic susceptibility data reveal all Fe 2 pairwise interactions to be antiferromagnetic. For 1 and 2, the different J ij couplings were estimated by use of a magnetostructural correlation for high nuclearity Fe III -oxo clusters and by density functional theory calculations using broken symmetry methods, allowing identification of their relative spin vector alignments and thus rationalization of their S = 0 ground states. The J ij values were then used as input values to give excellent fits of the experimental χM T vs T data. For 3, the fits of the experimental χM T vs T data to the Van Vleck equation or with PHI gave a very weak J 12 = -0.8(1) cm -1 (H = –2JŠ i ·Š j convention) between adjacent Fe III ions, and an S = 5/2 ground state. Furthermore, these initial Fe III arsinate complexes also provide structural parameters that help validate literature assignments of arsinate binding modes to iron oxide/hydroxide minerals as part of environmental concerns of using arsenic-containing herbicides in agriculture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗