Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Mars Environmental Compatibility Assessment (MECA): Identifying the Hazards of the Martian Soil

Sometime in the next decade NASA will decide whether to send a human expedition to explore the planet Mars. The Mars Environmental Compatibility Assessment (MECA) has been selected by NASA to evaluate the Martian environment for soil and dust hazards to human exploration. The integrated MECA payload contains three elements: a wet-chemistry laboratory, a microscopy station, and enhancements to a lander robot-arm system incorporating arrays of material patches and an electrometer to identify triboelectric charging during soil excavation. The wet-chemistry laboratory will evaluate samples of Martian soil in water to determine the total dissolved solids, redox potential, pH, and quantify the concentration of many soluble ions using ion-selective electrodes. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential. MECA's microscopy station combines optical and atomic-force microscopy with a robot-arm camera to provide imaging over nine orders of magnitude, from meters to nanometers. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined on the microscope stage using an ar-ray of sample receptacles and collection substrates, and an abrasion tool,. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. Although selected by NASA's Human Exploration and Development of Space Enterprise, the MECA instrument suite also has the capability to address basic geology, paleoclimate, and exobiology issues. To understand both contemporaneous and ancient processes on Mars, the mineralogical, petrological, and reactivity of Martian surface materials should be constrained: the NMCA experiment will shed light on these quantities through its combination of chemistry and microscopy. On Earth, the earliest forms of life are preserved as microfossils. The atomic-force microscope will have the required resolution to image down to the scale of terrestrial microfossils and beyond.

Meloy, T. P.↗

Morphological transitions on lithium metal anodes.

Coin cells were prepared using a metallic lithium anode, a Li{sub 4}Ti{sub 5}O{sub 12} cathode, and a 1.2 M LiPF{sub 6}/ethylene carbonate:ethyl methyl carbonate (30:70 wt %) electrolyte. The cells were cycled galvanostatically between 1 and 2 V vs Li/Li{sup +} (i=2.0 mA/cm{sup 2}) at a 2C rate. After a specific number of cycles, the cells were disassembled and the morphology of the lithium anode was characterized using scanning electron microscopy. It was observed that the surface morphology of the lithium metal electrode transitioned from a flat and smooth morphology to a microscopically rugged structure that shows three distinct layers: a top dendritic layer, an intermediate porous layer, and a residual metallic lithium layer. Morphological and electrochemical evidence points to the depletion of the electrolyte and the active metallic lithium that reacted to produce the porous layer as the most likely cause of cell failure under the conditions studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The material dependence of temperature measurement resolution in thermal scanning electron microscopy

Thermal scanning electron microscopy is a recently developed temperature mapping technique based on thermal diffuse scattering in electron backscatter diffraction in a scanning electron microscope. It provides nano-scale and non-contact temperature mapping capabilities. Due to the specific temperature sensitive mechanism inherent to this technique, the temperature resolution is highly material dependent. A thorough investigation of what material properties affect the temperature resolution is important for realizing the inherent temperature resolution limit for each material. In this paper, three material dependent parameters-the Debye-Waller B-factor temperature sensitivity, backscatter yield, and lattice constant-are shown to control the temperature resolution.

36 MATERIALS SCIENCE↗

Detection of defects buried in metallic samples by scanning microwave microscopy

This paper reports the local detection of buried calibrated metal defects in metal samples by a new experimental technique, scanning microwave microscopy. This technique combines the electromagnetic measurement capabilities of a microwave vector network analyzer with the subnanometer-resolution capabilities of an atomic force microscope. The network analyzer authorizes the use of several frequencies in the range 1-6 GHz, allowing three-dimensional tomographical investigation, which is useful for the detection of bulk defects in metal materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of dynamic morphological changes of tin anode electrode during (de)lithiation processes using in operando synchrotron transmission X-ray microscopy

The morphological evolution of tin particles with different sizes during the first lithiation and delithiation processes has been visualized by an in operando synchrotron transmission X-ray microscope (TXM). Here, the in operando lithium ion battery cell was operated at constant current condition during TXM imaging. Two-dimensional projection images with 40 nm resolution showing morphological evolution were obtained and analyzed. The analysis of relative area change shows that the morphology of tin particles with different sizes changed simultaneously. This phenomenon is mainly because of a negative feedback mechanism among tin particles in the battery electrode at a constant current operating condition. For irregular-shaped tin particles, the contour analysis demonstrates that the regions with higher curvature started volume expansion first, and then the entire particle expanded almost homogeneously. This study provides insights for understanding the dynamic morphological change and the particle-particle interactions in high capacity lithium ion battery electrodes.

25 ENERGY STORAGE↗

Development of X-ray Microscopy at IPOE

In order to meet the different requirements of applications in synchrotron radiation and plasma diagnosis in China, focusing and imaging optics based on Kirkpatrick-Baez (KB) mirrors, compound refractive lenses (CRLs), and multilayer Laue lenses (MLLs) were studied in our lab. A one-dimensional KB microscope using mirrors with a dual-periodic multilayer coating was developed. The multilayer mirror can reflect both 4.75 keV (Ti K-line) and 8.05 keV (Cu K-line) simultaneously, which makes alignment easier. For hard x-ray microscopy, CRL was studied. Using a SU-8 resist planar parabolic CRL, a focal line of 28.8-{mu}m width was obtained. To focus hard x-rays to nanometer levels efficiently, an MLL was fabricated using a WSi{sub 2}/Si multilayer. The MLL consists of 324 alternating WSi{sub 2} and Si layers with a total thickness of 7.9 {mu}m. (Recently, a much thicker multilayer has been deposited with a layer number of n = 1582 and a total thickness of 27 {mu}m.) After deposition, the sample was sliced and polished into an approximate ideal aspect ratio (depth of the zone plate to outmost layer thickness); the measured results show an intact structure remains, and the surface roughness of the cross section is about 0.4 nm after grinding and polishing processes.

43 PARTICLE ACCELERATORS↗

SEM visualization of glycosylated surface molecules using lectin-coated microspheres

There are several techniques currently used to localize glycosylated surface molecules by scanning electron microscopy (Grinnell, 1980; Molday, 1976; Linthicum and Sell, 1975; Nicolson, 1974; Lo Buglio, et al, 1972). A simple and rapid method, using a modification of Grinnell's technique is reported here. Essentially, microspheres coated with Concavalin A are used to bind to glycosylated regions of the palatal shelf epithelium and are visualized in the scanning electron microscope (SEM).

Non-NASA Center↗

Molecular flexure and atom trapping with sexiphenyl molecules by scanning tunneling microscope manipulation

Molecular flexure, and molecule-metal contact of para-sexiphenyl molecules on a Ag(111) surface are investigated by using low temperature scanning tunneling microscopy, and molecular manipulations. Atom trapping with sexiphenyl molecules is realized by laterally manipulating the molecules onto individual silver atoms and up to three silver atoms have been trapped. We also demonstrate breaking of a silver dimer into individual silver atoms by atom trapping. STM manipulation experiments show that the molecule-metal complexes formed by the atom trapping are mechanically stable. Moreover, Lateral manipulation of a single sexiphenyl across a Ag(111) atomic step highlights how the molecule moves across step-edges; the molecule can easily conform across the step and it recovers original configuration after the manipulation.

36 MATERIALS SCIENCE↗

In situ Measurments in a Transmission Electron Microscopy on Nanomagnetic Tunnel Junctions

We showed that a chain of nanomagnetic tunnel junctions (MTJs) devices can be electrically addressed individually, in situ, in a transmission electron microscope, such that transport properties can be in principle, quantitatively correlated with each device's defects and microstructure. A unique energy barrier was obtained for each device measured. Additionally, in situ tunneling magnetoresistance (TMR) measurements were obtained for a subset of devices. We found that TMR values for our nano-MTJs were generally smaller than TMR in the unpatterned film.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Prediction of atomic force microscope probe dynamics through the receptance coupling method

The increased growth in the use of tip-based sensing, manipulations, and fabrication of devices in atomic force microscopy (AFM) necessitates the accurate prediction of the dynamic behavior of the AFM probe. The chip holder, to which the micro-sensing device is attached, and the rest of the AFM system can affect the overall dynamics of the probe. In order to consider these boundary effects, we propose a novel receptance coupling method to mathematically combine the dynamics of the AFM setup and probe, based on the equilibrium and compatibility conditions at the joint. Once the frequency response functions of displacement over force at the tool tip are obtained, the dynamic interaction forces between the tip and the sample in nanoscale can be determined by measuring the probe tip displacement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stratification of centrifuged amoeba nuclei investigated by electron microscopy

Study establishes a relationship between radioresistance and the nucleolar stratification characteristics of various amoeba species. Two species of fresh water amoeba are studied with the electron microscope. The report discusses the nature of nucleolar layers and their possible relationship to the differences in radiosensitivity of the two amoeba species.

Breyer, E. P.↗

Vibrational spectra of nanowires measured using laser doppler vibrometry and STM studies of epitaxial graphene : an LDRD fellowship report.

A few of the many applications for nanowires are high-aspect ratio conductive atomic force microscope (AFM) cantilever tips, force and mass sensors, and high-frequency resonators. Reliable estimates for the elastic modulus of nanowires and the quality factor of their oscillations are of interest to help enable these applications. Furthermore, a real-time, non-destructive technique to measure the vibrational spectra of nanowires will help enable sensor applications based on nanowires and the use of nanowires as AFM cantilevers (rather than as tips for AFM cantilevers). Laser Doppler vibrometry is used to measure the vibration spectra of individual cantilevered nanowires, specifically multiwalled carbon nanotubes (MWNTs) and silver gallium nanoneedles. Since the entire vibration spectrum is measured with high frequency resolution (100 Hz for a 10 MHz frequency scan), the resonant frequencies and quality factors of the nanowires are accurately determined. Using Euler-Bernoulli beam theory, the elastic modulus and spring constant can be calculated from the resonance frequencies of the oscillation spectrum and the dimensions of the nanowires, which are obtained from parallel SEM studies. Because the diameters of the nanowires studied are smaller than the wavelength of the vibrometer's laser, Mie scattering is used to estimate the lower diameter limit for nanowires whose vibration can be measured in this way. The techniques developed in this thesis can be used to measure the vibrational spectra of any suspended nanowire with high frequency resolution Two different nanowires were measured - MWNTs and Ag{sub 2}Ga nanoneedles. Measurements of the thermal vibration spectra of MWNTs under ambient conditions showed that the elastic modulus, E, of plasma-enhanced chemical vapor deposition (PECVD) MWNTs is 37 {+-} 26 GPa, well within the range of E previously reported for CVD-grown MWNTs. Since the Ag{sub 2}Ga nanoneedles have a greater optical scattering efficiency than MWNTs, their vibration spectra was more extensively studied. The thermal vibration spectra of Ag{sub 2}Ga nanoneedles was measured under both ambient and low-vacuum conditions. The operational deflection shapes of the vibrating Ag{sub 2}Ga nanoneedles was also measured, allowing confirmation of the eigenmodes of vibration. The modulus of the crystalline nanoneedles was 84.3 {+-} 1.0 GPa. Gas damping is the dominate mechanism of energy loss for nanowires oscillating under ambient conditions. The measured quality factors, Q, of oscillation are in line with theoretical predictions of air damping in the free molecular gas damping regime. In the free molecular regime, Q{sub gas} is linearly proportional to the density and diameter of the nanowire and inversely proportional to the air pressure. Since the density of the Ag{sub 2}Ga nanoneedles is three times that of the MWNTs, the Ag{sub 2}Ga nanoneedles have greater Q at atmospheric pressures. Our initial measurements of Q for Ag{sub 2}Ga nanoneedles in low-vacuum (10 Torr) suggest that the intrinsic Q of these nanoneedles may be on the order of 1000. The epitaxial carbon that grows after heating (000{bar 1}) silicon carbide (SiC) to high temperatures (1450-1600) in vacuum was also studied. At these high temperatures, the surface Si atoms sublime and the remaining C atoms reconstruct to form graphene. X-ray photoelectron spectroscopy (XPS) and scanning tunneling microscopy (STM) were used to characterize the quality of the few-layer graphene (FLG) surface. The XPS studies were useful in confirming the graphitic composition and measuring the thickness of the FLG samples. STM studies revealed a wide variety of nanometer-scale features that include sharp carbon-rich ridges, moire superlattices, one-dimensional line defects, and grain boundaries. By imaging these features with atomic scale resolution, considerable insight into the growth mechanisms of FLG on the carbon-face of SiC is obtained.

36 MATERIALS SCIENCE↗

The effect of ball-milling time and annealing temperature on fracture toughness of Ni-3 wt.% SiC using small punch testing

Highlights: • The fracture energy of Ni-SiC is strongly dependent on the grain size of Ni matrix • The ball-milling time governs the fracture behaviour of Ni-3 wt.% SiC • A higher proportion of big SiC particles at grain boundary is responsible for a lower fracture toughness - Abstract: A set of dispersion strengthened Ni-3 wt.% SiC samples have been prepared via a powder metallurgy route for an application in molten salt reactor (MSR) systems. A mixture of 97 wt.% Ni and 3 wt.% SiC powder was prepared by varying the ball-milling time (8, 24, 36 and 48 h). The ball-milling process was followed by powder consolidation using spark plasma sintering (SPS) and rapid cooling to room temperature. The samples were then annealed at different temperatures (300 °C, 700 °C and 850 °C). The fracture behaviour of the Ni-3 wt.% SiC samples was investigated using the Small Punch Test (SPT). A scanning electron microscope (SEM) with energy dispersive spectrometer (EDS) and electron back-scatter diffraction (EBSD), as well as transmission electron microscopy (TEM) were employed to examine the microstructure of the tested Ni-3 wt.% SiC samples. The obtained results show that the SPT fracture energy is strongly dependent on the grain size of Ni matrix, which is affected by ball-milling times and annealing temperature. It has been further found that the segregation of large SiC particles at grain boundaries promotes intergranular fracture and thus significantly reduces the fracture energy. The results indicate that the distribution and size of SiC particles at grain boundary is mainly affected by the ball-milling time. Hence, the ball-milling time governs the fracture toughness of Ni-3 wt.% SiC samples.

36 MATERIALS SCIENCE↗

A Transmission Electron Microscopy Study of the Effect of Interfaces on Bubble Formation in He-Implanted Cu-Nb Multilayers

Magnetron sputtered thin films of Cu, Nb, and Cu-Nb multilayers with 2.5 and 5 nm nominal layer thickness were deposited on Si and implanted with 4He+ and 3He+ ions. Secondary ion mass spectroscopy and nuclear reaction analysis, respectively, were used to measure the 4He+ and 3He+ concentration profile with depth inside the films. Cross-sectional transmission electron microscopy was used to characterize the helium bubbles. Analysis of the contrast from helium bubbles in defocused transmission electron microscope images showed a minimum bubble diameter of 1.25 nm. While pure Cu and Nb films showed bubble contrast over the entire range of helium implantation, the multilayers exhibited bubbles only above a critical He concentration that increased almost linearly with decreasing layer thickness. The work shows that large amounts of helium can be trapped at incoherent interfaces in the form of stable, nanometer-size bubbles.

36 MATERIALS SCIENCE↗

Airtight container for the transfer of atmosphere-sensitive materials into vacuum-operated characterization instruments

This paper describes the design and operation of a simple airtight container devised to facilitate the transfer of atmosphere-sensitive samples from a glovebox to the vacuum chamber of an analytical instrument such as a scanning electron microscope. The use of this device for characterizing the microstructure of highly hygroscopic strontium iodide ceramics by scanning electron microscopy is illustrated as an application example.

36 MATERIALS SCIENCE↗

Formation of double ring patterns on Co{sub 2}MnSi Heusler alloy thin film by anodic oxidation under scanning probe microscope

Double ring formation on Co{sub 2}MnSi (CMS) films is observed at electrical breakdown voltage during local anodic oxidation (LAO) using atomic force microscope (AFM). Corona effect and segregation of cobalt in the vicinity of the rings is studied using magnetic force microscopy and energy dispersive spectroscopy. Double ring formation is attributed to the interaction of ablated material with the induced magnetic field during LAO. Steepness of forward bias transport characteristics from the unperturbed region of the CMS film suggest a non equilibrium spin contribution. Such mesoscopic textures in magnetic films by AFM tip can be potentially used for memory storage applications.

36 MATERIALS SCIENCE↗

Defining the layers of a sensory cilium with STORM and cryoelectron nanoscopy

Primary cilia carry out numerous signaling and sensory functions, and defects in them, “ciliopathies,” cause a range of symptoms, including blindness. Understanding of their nanometer-scale ciliary substructures and their disruptions in ciliopathies has been hindered by limitations of conventional microscopic techniques. In this work, we have combined cryoelectron tomography, enhanced by subtomogram averaging, with superresolution stochastic optical reconstruction microscopy (STORM) to define subdomains within the light-sensing rod sensory cilium of mouse retinas and reveal previously unknown substructures formed by resident proteins. Domains are demarcated by structural features such as the axoneme and its connections to the ciliary membrane, and are correlated with molecular markers of subcompartments, including the lumen and walls of the axoneme, the membrane glycocalyx, and the intervening cytoplasm. Within this framework, we report spatial distributions of key proteins in wild-type (WT) mice and the effects on them of genetic deficiencies in 3 models of Bardet–Biedl syndrome.

59 BASIC BIOLOGICAL SCIENCES↗

Neutral but Impactful: Gallium Cluster-Induced Nanopores from Beam-Blanked Gallium Ion Sources

Neutral atoms originating from liquid metal ion sources are an often-overlooked source of contamination and damage in focused ion beam microscopy. Beyond ions and single atoms, these sources also generate atom clusters. While most studies have investigated charged clusters, here we demonstrate that neutral clusters are also formed. These neutral clusters bypass the electrostatic beam blanking system, allowing them to impinge on samples even when the ion beam is blanked. We investigate this phenomenon using thin (≤20 nm) freestanding membranes of hexagonal boron nitride, silicon, and silicon nitride as targets. Randomly dispersed nanopores that form upon neutral cluster exposure are revealed. The average nanopore diameter is ∼2 nm with a narrow size distribution, suggesting that the atom clusters have a preferred size. Various electron microscopy techniques are used to characterize the nanopores, including high-resolution transmission electron microscopy, multislice ptychography, and electron energy-loss spectroscopy. Finally, we show how electron irradiation in the transmission electron microscope can be used to both remove any amorphous material that may clog the pores and to controllably grow the pores to specific sizes. Tunable nanopores such as these are interesting for nanofluidic applications requiring size-selective membranes.

Byrne, Dana O↗