Search NASA⌕ Search

SEARCH · Search NASA

Results for “image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Progressive transmission and compression images

We describe an image data compression strategy featuring progressive transmission. The method exploits subband coding and arithmetic coding for compression. We analyze the Laplacian probability density, which closely approximates the statistics of individual subbands, to determine a strategy for ordering the compressed subband data in a way that improves rate-distortion performance. Results are presented for a test image.

Kiely, A. B.↗

Progressive Transmission and Compression of Images

We describe an image data compression strategy featuring progressive transmission. The method exploits subband coding and arithmetic coding for compression. We analyze the Laplacian probability density, which closely approximates the statistics of individual subbands, to determine a strategy for ordering the compressed subband data in a way that improves rate-distortion performance. Results are presented for a test image.

Kiely, A. B.↗

Digitizing zone maps, using modified LARSYS program

A method for digitizing zone maps is presented, starting with colored images and producing a final one-channel digitized tape. This method automates the work previously done interactively on the Image-100 and Data Analysis System computers of the Johnson Space Center (JSC) Earth Observations Division (EOD). A color-coded map was digitized through color filters on a scanner to form a digital tape in LARSYS-2 or JSC Universal format. The taped image was classified by the EOD LARSYS program on the basis of training fields included in the image. Numerical values were assigned to all pixels in a given class, and the resulting coded zone map was written on a LARSYS or Universal tape. A unique spatial filter option permitted zones to be made homogeneous and edges of zones to be abrupt transitions from one zone to the next. A zoom option allowed the output image to have arbitrary dimensions in terms of number of lines and number of samples on a line. Printouts of the computer program are given and the images that were digitized are shown.

Giddings, L.↗

Lossless Compression of Classification-Map Data

A lossless image-data-compression algorithm intended specifically for application to classification-map data is based on prediction, context modeling, and entropy coding. The algorithm was formulated, in consideration of the differences between classification maps and ordinary images of natural scenes, so as to be capable of compressing classification- map data more effectively than do general-purpose image-data-compression algorithms. Classification maps are typically generated from remote-sensing images acquired by instruments aboard aircraft (see figure) and spacecraft. A classification map is a synthetic image that summarizes information derived from one or more original remote-sensing image(s) of a scene. The value assigned to each pixel in such a map is the index of a class that represents some type of content deduced from the original image data for example, a type of vegetation, a mineral, or a body of water at the corresponding location in the scene. When classification maps are generated onboard the aircraft or spacecraft, it is desirable to compress the classification-map data in order to reduce the volume of data that must be transmitted to a ground station.

Hua, Xie↗

MATCHED-INDEX-OF-REFRACTION FLOW FACILITY FOR FUNDAMENTAL AND APPLIED RESEARCH

Significant challenges face reactor designers with regard to thermal hydraulic design and associated modeling for advanced reactor concepts. Computational thermal hydraulic codes solve only a piece of the core. There is a need for a whole core dynamics system code with local resolution to investigate and understand flow behavior with all the relevant physics and thermo-mechanics. The matched index of refraction (MIR) flow facility at Idaho National Laboratory (INL) has a unique capability to contribute to the development of validated computational fluid dynamics (CFD) codes through the use of state-of-the-art optical measurement techniques, such as Laser Doppler Velocimetry (LDV) and Particle Image Velocimetry (PIV). PIV is a non-intrusive velocity measurement technique that tracks flow by imaging the movement of small tracer particles within a fluid. At the heart of a PIV calculation is the cross correlation algorithm, which is used to estimate the displacement of particles in some small part of the image over the time span between two images. Generally, the displacement is indicated by the location of the largest peak. To quantify these measurements accurately, sophisticated processing algorithms correlate the locations of particles within the image to estimate the velocity (Ref. 1). Prior to use with reactor deign, the CFD codes have to be experimentally validated, which requires rigorous experimental measurements to produce high quality, multi-dimensional flow field data with error quantification methodologies. Computational thermal hydraulic codes solve only a piece of the core. There is a need for a whole core dynamics system code with local resolution to investigate and understand flow behavior with all the relevant physics and thermo-mechanics. Computational techniques with supporting test data may be needed to address the heat transfer from the fuel to the coolant during the transition from turbulent to laminar flow, including the possibility of an early laminarization of the flow (Refs. 2 and 3) (laminarization is caused when the coolant velocity is theoretically in the turbulent regime, but the heat transfer properties are indicative of the coolant velocity being in the laminar regime). Such studies are complicated enough that computational fluid dynamics (CFD) models may not converge to the same conclusion. Thus, experimentally scaled thermal hydraulic data with uncertainties should be developed to support modeling and simulation for verification and validation activities. The fluid/solid index of refraction matching technique allows optical access in and around geometries that would otherwise be impossible while the large test section of the INL system provides better spatial and temporal resolution than comparable facilities. Benchmark data for assessing computational fluid dynamics can be acquired for external flows, internal flows, and coupled internal/external flows for better understanding of physical phenomena of interest. The core objective of this study is to describe MIR and its capabilities, and mention current development areas for uncertainty quantification, mainly the uncertainty surface method and cross-correlation method. Using these methods, it is anticipated to establish a suitable approach to quantify PIV uncertainty for experiments performed in the MIR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-G-JeP2-14: MRI-Based HDR Prostate Brachytherapy: A Phantom Study for Interstitial Catheter Reconstruction with 0.35T MRI Images

Purpose: To evaluate the accuracy of interstitial catheter reconstruction with 0.35T MRI images for MRI-based HDR prostate brachytherapy. Methods: Recently, a real-time MRI-guided radiotherapy system combining a 0.35T MRI system and three cobalt 60 heads (MRIdian System, ViewRay, Cleveland, OH, USA) was installed in our department. A TrueFISP sequence for MRI acquisition at lower field on Viewray was chosen due to its fast speed and high signal-to-noise efficiency. Interstitial FlexiGuide needles were implanted into a tissue equivalent ultrasound prostate phantom (CIRS, Norfolk, Virginia, USA). After an initial 15s pilot MRI to confirm the location of the phantom, planning MRI was acquired with a 172s TrueFISP sequence. The pulse sequence parameters included: flip angle = 60 degree, echo time (TE) =1.45 ms, repetition time (TR) = 3.37 ms, slice thickness = 1.5 mm, field of view (FOV) =500 × 450mm. For a reference image, a CT scan was followed. The CT and MR scans were then fused with the MIM Maestro (MIM software Inc., Cleveland, OH, USA) and sent to the Oncentra Brachy planning system (Elekta, Veenendaal, Netherlands). Automatic catheter reconstruction using CT and MR image intensities followed by manual reconstruction was used to digitize catheters. The accuracy of catheter reconstruction was evaluated from the catheter tip location. Results: The average difference between the catheter tip locations reconstructed from the CT and MR in the transverse, anteroposterior, and craniocaudal directions was −0.1 ± 0.1 mm (left), 0.2 ± 0.2 mm (anterior), and −2.3 ± 0.5 mm (cranio). The average distance in 3D was 2.3 mm ± 0.5 mm. Conclusion: This feasibility study proved that interstitial catheters can be reconstructed with 0.35T MRI images. For more accurate catheter reconstruction which can affect final dose distribution, a systematic shift should be applied to the MR based catheter reconstruction in HDR prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

3D inpatient dose reconstruction from the PET-CT imaging of {sup 90}Y microspheres for metastatic cancer to the liver: Feasibility study

Purpose: The introduction of radioembolization with microspheres represents a significant step forward in the treatment of patients with metastatic disease to the liver. This technique uses semiempirical formulae based on body surface area or liver and target volumes to calculate the required total activity for a given patient. However, this treatment modality lacks extremely important information, which is the three-dimensional (3D) dose delivered by microspheres to different organs after their administration. The absence of this information dramatically limits the clinical efficacy of this modality, specifically the predictive power of the treatment. Therefore, the aim of this study is to develop a 3D dose calculation technique that is based on the PET imaging of the infused microspheres.Methods: The Fluka Monte Carlo code was used to calculate the voxel dose kernel for {sup 90}Y source with voxel size equal to that of the PET scan. The measured PET activity distribution was converted to total activity distribution for the subsequent convolution with the voxel dose kernel to obtain the 3D dose distribution. In addition, dose-volume histograms were generated to analyze the dose to the tumor and critical structures.Results: The 3D inpatient dose distribution can be reconstructed from the PET data of a patient scanned after the infusion of microspheres. A total of seven patients have been analyzed so far using the proposed reconstruction method. Four patients underwent treatment with SIR-Spheres for liver metastases from colorectal cancer and three patients were treated with Therasphere for hepatocellular cancer. A total of 14 target tumors were contoured on post-treatment PET-CT scans for dosimetric evaluation. Mean prescription activity was 1.7 GBq (range: 0.58–3.8 GBq). The resulting mean maximum measured dose to targets was 167 Gy (range: 71–311 Gy). Mean minimum dose to 70% of target (D70) was 68 Gy (range: 25–155 Gy). Mean minimum dose to 90% of target (D90) was 53 Gy (range: 13–125 Gy).Conclusions: A three-dimensional inpatient dose reconstruction method has been developed that is based on the PET/CT data of a patient treated with {sup 90}Y microspheres. It allows for a complete description of the absorbed dose by the tumor and critical structures. It represents the first step in building predictive models for treatment outcomes for patients receiving this therapeutic modality as well as it allows for better analysis of patients' dose response and will ultimately improve future treatment administration.

61 RADIATION PROTECTION AND DOSIMETRY↗

A software-based x-ray scatter correction method for breast tomosynthesis

Purpose: To develop a software-based scatter correction method for digital breast tomosynthesis (DBT) imaging and investigate its impact on the image quality of tomosynthesis reconstructions of both phantoms and patients. Methods: A Monte Carlo (MC) simulation of x-ray scatter, with geometry matching that of the cranio-caudal (CC) view of a DBT clinical prototype, was developed using the Geant4 toolkit and used to generate maps of the scatter-to-primary ratio (SPR) of a number of homogeneous standard-shaped breasts of varying sizes. Dimension-matched SPR maps were then deformed and registered to DBT acquisition projections, allowing for the estimation of the primary x-ray signal acquired by the imaging system. Noise filtering of the estimated projections was then performed to reduce the impact of the quantum noise of the x-ray scatter. Three dimensional (3D) reconstruction was then performed using the maximum likelihood-expectation maximization (MLEM) method. This process was tested on acquisitions of a heterogeneous 50/50 adipose/glandular tomosynthesis phantom with embedded masses, fibers, and microcalcifications and on acquisitions of patients. The image quality of the reconstructions of the scatter-corrected and uncorrected projections was analyzed by studying the signal-difference-to-noise ratio (SDNR), the integral of the signal in each mass lesion (integrated mass signal, IMS), and the modulation transfer function (MTF). Results: The reconstructions of the scatter-corrected projections demonstrated superior image quality. The SDNR of masses embedded in a 5 cm thick tomosynthesis phantom improved 60%-66%, while the SDNR of the smallest mass in an 8 cm thick phantom improved by 59% (p < 0.01). The IMS of the masses in the 5 cm thick phantom also improved by 15%-29%, while the IMS of the masses in the 8 cm thick phantom improved by 26%-62% (p < 0.01). Some embedded microcalcifications in the tomosynthesis phantoms were visible only in the scatter-corrected reconstructions. The visibility of the findings in two patient images was also improved by the application of the scatter correction algorithm. The MTF of the images did not change after application of the scatter correction algorithm, indicating that spatial resolution was not adversely affected. Conclusions: Our software-based scatter correction algorithm exhibits great potential in improving the image quality of DBT acquisitions of both phantoms and patients. The proposed algorithm does not require a time-consuming MC simulation for each specific case to be corrected, making it applicable in the clinical realm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emission spectroscopy with coded apertures for enhanced dimensionality

A coded aperture is used to demonstrate emission spectroscopy from multiple one-dimensional measurement locations simultaneously with a single camera. The coded aperture mask has several columns of periodic apertures, each with a unique spatial frequency. Light transmitted through all mask columns is detected through an imaging spectrometer. Dispersed light from the various mask columns overlaps on the spectrometer camera but is separated using Fourier-domain filtering using the known spatial frequencies of the mask. As the coded aperture is placed at an image plane, each Fourier-filtered spectrogram comes from a unique one-dimensional measurement location. This technique represents a significant increase in the amount of spatially and spectrally resolved emission data available using a single emission spectrometer and camera at the expense of some spatial resolution due to the Fourier filtering. This instrument is particularly useful for studying transient, non-repeating events. Megahertz-rate emission spectroscopy from five one-dimensional measurement locations is demonstrated with explosive fireballs using a single camera. Optical design parameters and instrument performance characteristics are discussed.

42 ENGINEERING↗

Optical boundary reconstruction of tokamak plasmas for feedback control of plasma position and shape

A new diagnostic is developed to reconstruct the plasma boundary using visible wavelength images. Exploiting the plasma's edge localized and toroidally symmetric emission profile, a new coordinate transform is presented to reconstruct the plasma boundary from a poloidal view image. The plasma boundary reconstruction is implemented in MATLAB and applied to camera images of Mega-Ampere Spherical Tokamak discharges. The optically reconstructed plasma boundaries are compared to magnetic reconstructions from the offline reconstruction code EFIT, showing very good qualitative and quantitative agreement. Average errors are within 2 cm and correlation is high. In the current software implementation, plasma boundary reconstruction from a single image takes 3 ms. The applicability and system requirements of the new optical boundary reconstruction, called OFIT, for use in both feedback control of plasma position and shape and in offline reconstruction tools are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrasonic power measurement system based on acousto-optic interaction

Ultrasonic waves are widely used, with applications including the medical, military, and chemical fields. However, there are currently no effective methods for ultrasonic power measurement. Previously, ultrasonic power measurement has been reliant on mechanical methods such as hydrophones and radiation force balances. This paper deals with ultrasonic power measurement based on an unconventional method: acousto-optic interaction. Compared with mechanical methods, the optical method has a greater ability to resist interference and also has reduced environmental requirements. Therefore, this paper begins with an experimental determination of the acoustic power in water contained in a glass tank using a set of optical devices. Because the light intensity of the diffraction image generated by acousto-optic interaction contains the required ultrasonic power information, specific software was written to extract the light intensity information from the image through a combination of filtering, binarization, contour extraction, and other image processing operations. The power value can then be obtained rapidly by processing the diffraction image using a computer. The results of this work show that the optical method offers advantages that include accuracy, speed, and a noncontact measurement method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-line, High-Throughput Quality Monitoring for Fuel Cell and Electrolyzer Components Based on Transmission and Reflection Imaging

During the manufacturing of fuel cell and electrolyzer membranes and membrane electrode assemblies (MEAs), real-time, in-line, high-throughput optical-based quality monitoring methods are essential for detecting defects and monitoring thickness variations, thus improving the performance and increasing the durability of fuel cell and electrolyzer in the hydrogen industry. For the MEAs with very opaque coatings, optical transmission-based imaging has been developed and applied in the Roll-to-Roll system using a flashlight and a high-sensitivity CCD camera. We observed high signal-to-noise ratio images while the Roll-to-Roll system ran at 5 ft/min. The entire sample image could quickly be recovered from the discrete frames using customized Python codes for automatic frame cropping and stitching. We detected significant non-uniformities in our experimental MEAs specimen. For fuel cell and low-temperature electrolysis (LTE) transparent membranes, we used optical reflectance hyperspectral imaging with interference fringe-based thickness mapping. We set up a hyperspectral camera to measure various rolls of commercial membranes. The measurement results are analyzed to find the thickness distribution of each roll and to check for defects. Transmission and reflection imaging-based quality monitoring techniques demonstrated in this project can be widely used in the mass production environment to improve the production yield and performance of hydrogen devices.

DIRECT ENERGY CONVERSION,ENGINEERING↗

Digital Image Correlation Engine v.3.0

DICe is an open source digital image correlation (DIC) tool intended for use as a module in an external application or as a standalone analysis code. It's primary capability is computing full-field displacements and strains from sequences of digital These images are typically of a material sample undergoing a materials characterization experiment, but DICe is also useful for other applications (for example, trajectory tracking). DICe is machine portable (Windows, Linux and Mac) and can be effectively deployed on a high performance computing platform. Capabilities from DICe can be invoked through a library interface, via source code integration of DICe classes or through a graphical user interface.

Turner, Dan↗

SU-F-J-47: Inherent Uncertainty in the Positional Shifts Determined by a Volumetric Cone Beam Imaging System

Purpose: To quantify inherent uncertainty associated with a volumetric imaging system in its determination of positional shifts. Methods: The study was performed on an Elekta Axesse™ linac’s XVI cone beam computed tomography (CBCT) system. A CT image data set of a Penta- Guide phantom was used as reference image by placing isocenter at the center of the phantom.The phantom was placed arbitrarily on the couch close to isocenter and CBCT images were obtained. The CBCT dataset was matched with the reference image using XVI software and the shifts were determined in 6-dimensions. Without moving the phantom, this process was repeated 20 times consecutively within 30 minutes on a single day. Mean shifts and their standard deviations in all 6-dimensions were determined for all the 20 instances of imaging. For any given day, the first set of shifts obtained was kept as reference and the deviations of the subsequent 19 sets from the reference set were scored. Mean differences and their standard deviations were determined. In this way, data were obtained for 30 consecutive working days. Results: Tabulating the mean deviations and their standard deviations observed on each day for the 30 measurement days, systematic and random errors in the determination of shifts by XVI software were calculated. The systematic errors were found to be 0.03, 0.04 and 0.03 mm while random errors were 0.05, 0.06 and 0.06 mm in lateral, craniocaudal and anterio-posterior directions respectively. For rotational shifts, the systematic errors were 0.02°, 0.03° and 0.03° and random errors were 0.06°, 0.05° and 0.05° in pitch, roll and yaw directions respectively. Conclusion: The inherent uncertainties in every image guidance system should be assessed and baseline values established at the time of its commissioning. These shall be periodically tested as part of the QA protocol.

60 APPLIED LIFE SCIENCES↗

Automated Defect Identification For Triso Fuels

The developed code is to be used to identify manufacturing defects of nuclear fuel kernels using image processing methods. Past batches of TRi-structural ISOtropic particle (TRISO) fuel kernels have on occasion contained fissures that result in the fuel batch not meeting specifications. The developed code automates the inspection process of these kernels. The code analyzes micrographs of TRISO fuel kernels and outputs a count of total kernels in the sample, a count of the number of defective particles in the sample, as well as processed images for more effective manual inspection. This information output will be used to help identify if defective kernels are present in a fuel batch and quantify the countable fissure fraction.

Oncken, JosephE.↗

Inverse Regression for Extraction of Tumor Site from Cancer Pathology Reports

Pathology reports are the primary source of information for cancer diagnosis of millions of the cancer patients across the United States. Cancer registries label these reports every year. The coded labels incorporate pertinent information such as cancer location, behavior, and histology. This information when combined with clinical information, medical imaging and even genomic information have a great potential to fuel discoveries in cancer research. The coding process is manual and requires many human experts to label the large volume of pathology reports in a timely manner. In this study, we have developed a supervised inverse regression based auto-labeler to automate the task. The experiments were conducted on a set of 942 pathology reports with human expert labels as the ground truth. We observed that the inverse regression based auto-labeler consistently performed better than or comparable to the best performing state-of-the-art method. These results demonstrate the potential of inverse regression for reliable information extraction from the pathology reports.

Dubey, Abhishek↗

Rapid Prototyping Integrated With Nondestructive Evaluation and Finite Element Analysis

Most reverse engineering approaches involve imaging or digitizing an object then creating a computerized reconstruction that can be integrated, in three dimensions, into a particular design environment. Rapid prototyping (RP) refers to the practical ability to build high-quality physical prototypes directly from computer aided design (CAD) files. Using rapid prototyping, full-scale models or patterns can be built using a variety of materials in a fraction of the time required by more traditional prototyping techniques (refs. 1 and 2). Many software packages have been developed and are being designed to tackle the reverse engineering and rapid prototyping issues just mentioned. For example, image processing and three-dimensional reconstruction visualization software such as Velocity2 (ref. 3) are being used to carry out the construction process of three-dimensional volume models and the subsequent generation of a stereolithography file that is suitable for CAD applications. Producing three-dimensional models of objects from computed tomography (CT) scans is becoming a valuable nondestructive evaluation methodology (ref. 4). Real components can be rendered and subjected to temperature and stress tests using structural engineering software codes. For this to be achieved, accurate high-resolution images have to be obtained via CT scans and then processed, converted into a traditional file format, and translated into finite element models. Prototyping a three-dimensional volume of a composite structure by reading in a series of two-dimensional images generated via CT and by using and integrating commercial software (e.g. Velocity2, MSC/PATRAN (ref. 5), and Hypermesh (ref. 6)) is being applied successfully at the NASA Glenn Research Center. The building process from structural modeling to the analysis level is outlined in reference 7. Subsequently, a stress analysis of a composite cooling panel under combined thermomechanical loading conditions was performed to validate this process.

Abdul-Aziz, Ali↗

Fuzzy Logic Enhanced Digital PIV Processing Software

Digital Particle Image Velocimetry (DPIV) is an instantaneous, planar velocity measurement technique that is ideally suited for studying transient flow phenomena in high speed turbomachinery. DPIV is being actively used at the NASA Glenn Research Center to study both stable and unstable operating conditions in a high speed centrifugal compressor. Commercial PIV systems are readily available which provide near real time feedback of the PIV image data quality. These commercial systems are well designed to facilitate the expedient acquisition of PIV image data. However, as with any general purpose system, these commercial PIV systems do not meet all of the data processing needs required for PIV image data reduction in our compressor research program. An in-house PIV PROCessing (PIVPROC) code has been developed for reducing PIV data. The PIVPROC software incorporates fuzzy logic data validation for maximum information recovery from PIV image data. PIVPROC enables combined cross-correlation/particle tracking wherein the highest possible spatial resolution velocity measurements are obtained.

Wernet, Mark P.↗