Search NASA⌕ Search

SEARCH · Search NASA

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

A remotely sensed pigment index reveals photosynthetic phenology in evergreen conifers

In evergreen conifers, where the foliage amount changes little with season, accurate detection of the underlying “photosynthetic phenology” from satellite remote sensing has been difficult, presenting challenges for global models of ecosystem carbon uptake. In this paper, we report a close correspondence between seasonally changing foliar pigment levels, expressed as chlorophyll/carotenoid ratios, and evergreen photosynthetic activity, leading to a “chlorophyll/carotenoid index” (CCI) that tracks evergreen photosynthesis at multiple spatial scales. When calculated from NASA’s Moderate Resolution Imaging Spectroradiometer satellite sensor, the CCI closely follows the seasonal patterns of daily gross primary productivity of evergreen conifer stands measured by eddy covariance. This discovery provides a way of monitoring evergreen photosynthetic activity from optical remote sensing, and indicates an important regulatory role for carotenoid pigments in evergreen photosynthesis. Improved methods of monitoring photosynthesis from space can improve our understanding of the global carbon budget in a warming world of changing vegetation phenology.

59 BASIC BIOLOGICAL SCIENCES↗

Point defects in semiconductors: Friends and foes for quantum technologies

Point defects in semiconductors are both a curse and a blessing in microelectronics: they enable the control of electrical conductivity through doping, yet can also act as trapping and recombination centers that degrade device performance. In quantum information science, defects play a similarly dual role. They can be harnessed as spin–photon interfaces enabling the coupling of electronic and nuclear spins to light and the creation of distributed entanglement for quantum networks or used as atomistic scale sensors for quantum sensing. At the same time, defects are a major source of decoherence for superconducting qubits, one of the leading quantum computing platforms. This article discusses how a deeper materials-level understanding of defects can guide the design of improved quantum devices for communication, sensing, and computation.

Zhu, Yizhi [Rice University, Houston, TX (United S↗

ATF-2 Ramp Conceptual Design Report

The following report documents the conceptual design for the ATF-2 Ramp experiment. The experiment aims to fill the in-pile irradiation testing gap to conduct integral ramp testing, which was created by the closure of R2, Osiris, and Halden test reactors. The concept involves the simultaneous ramping of three fuel pins using a power axial locator mechanism in the Loop-2A testing facility in the center flux trap of the advanced test reactor (ATR). The three fuel pins are ramped in individual coolant channels containing a prototypic PWR environment. Rod failure will be detected using a fuel rod elongation sensor attached to the fuel pin upper end cap. An axial stack of concentric hafnium and zirconium shrouds will be used to shape the flux around the test pins to create different power levels in each pin and to ensure the peak power location of each pin remains in the center of the test rod. Monte Carlo simulations are used to demonstrate the viability of this design concept.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rotation-Enabled 7-Degree of Freedom Seismometer for Geothermal Resource Development. Phase 1 Final Report

Under this Department of Energy (DOE) grant, A-Tech Corporation d.b.a. Applied Technology Associates (ATA), seeks to develop a seven-degree-of-freedom (7-DOF) seismic measurement tool for high-temperature geothermal applications. The Rotational-Enabled 7-DOF Seismometer includes a conventional tri-axial accelerometer, a conventional pressure sensor or hydrophone, and a tri-axial rotational sensor. The rotational sensing capability is novel, based upon ATA's innovative research in rotational sensing technologies. The geothermal industry requires tools for high-precision seismic monitoring of crack formation associated with Enhanced Geothermal System (EGS) stimulation activity. Currently, microseismic monitoring is conducted by deploying many seismic tools at different depth levels along a 'string' within drilled observation wells. Costs per string can be hundreds of thousands of dollars. Processing data from the spatial arrays of linear seismometers allows back-projection of seismic wave states. In contrast, a Rotational-Enabled 7-DOF Seismometer would simultaneously measure p-wave velocity, s-wave velocity, and incident seismic wave direction all from a single point measurement. In addition, the Rotational-Enabled 7-DOF Seismometer will, by its nature, separate p- and s-waves into different data streams, simplifying signal processing and facilitating analysis of seismic source signatures and geological characterization. By adding measurements of three additional degrees-of-freedom at each level and leveraging the information from this new seismic observable, it is likely that an equally accurate picture of subsurface seismic activity could be garnered with fewer levels per hole. The key cost savings would come from better siting of the well due to increased information content and a decrease in the number of confirmation wells drilled, also due to the increase in information per well. Improved seismic tools may also increase knowledge, understanding, and confidence, thus removing some current blocks to feasibility and significantly increasing access to potential geothermal sites. During the Phase 1 effort summarized in this final report, the ATA Team modeled and built two TRL 3 proof-of-concept test units for two competing rotational sensor technologies. The two competing technologies were based on ATA's angular rate and angular displacement measurement technologies; Angular rate: ATA's Magnetohydrodynamic Angular Rate Sensor (Seismic MHD); and Angular displacement: ATA's Low Frequency Improved Torsional Seismometer (LFITS). In order to down-select between these two technologies and formulate a go / no go decision, the ATA Team analyzed and traded scientific performance requirements and market constraints against sensor characteristics and components, acquiring field data where possible to validate the approach and publishing results from these studies of rotational technology capability. Based on the results of Phase 1, the ATA Team finds that the Seismic MHD (SMHD) technology is the best choice for enabling rotational seismometry and significant technical potential exists for micro-seismic monitoring using a downhole 7-DOF device based on the SMHD. Recent technical papers and field data confirm the potential of rotational sensing for seismic mapping, increasing confidence that cost-reduction benefits are achievable for EGS. However, the market for geothermal rotational sensing is small and undeveloped. As a result, this report recommends modifying the Phase 2 plan to focus on prototype development aimed at partnering with early adopters within the geothermal industry and the scientific research community. The highest public benefit will come from development and deployment of a science-grade SMHD rotational seismometer engineered for geothermal downhole conditions and an integrated test tool for downhole measurements at active geothermal test sites.

15 GEOTHERMAL ENERGY↗

Development of a Discrepancy Checker for the Digital Twin in a Supervisory Control System for a Thermal Energy Delivery System

Defined as a virtual representation of a physical object, process, or service, and used to support real-world decision-making, a digital twin (DT) can be utilized to combine classical and novel frameworks in sensors, state predictions, and multi-input/multi-output systems, and to enable optimal autonomous operations. However, a DT’s usefulness largely depends on its ability to adequately mirror the state of its physical counterpart, and this adequacy should be reflected by the level of uncertainty in the underlying simulation models when estimating and predicting quantities of interest (QOIs). Moreover, simulation models in a DT may involve multiple fidelities of representations—ranging from physics-based models to data-driven ones—but classical uncertainty quantification (UQ) methods struggle to handle numerous uncertainty sources, nor are they designed for real-time applications. This work presents a UQ-based discrepancy checking and diagnosis tool for a DT-based supervisory control system applied to a thermal energy delivery system (TEDS) at Idaho National Laboratory. The discrepancy checker was developed using metadata from an automated DT development process, and these metadata included different combinations of physical model forms and model parameters, training data and hyperparameters for surrogate models, and design parameters for supervisory control systems. Next, correlations between the uncertainty results and the metadata were established and then applied to the DT operations. The discrepancy checker evaluates the discrepancies between model predictions from virtual and sensor measurements and backtraces them to the corresponding major sources of uncertainty. The discrepancy checker showed reasonable performance in detecting discrepancies and diagnosing sources of uncertainty in testing scenarios.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Three-dimensional piezoelectric polymer microsystems for vibrational energy harvesting, robotic interfaces and biomedical implants

Piezoelectric microsystems are of use in areas such as mechanical sensing, energy conversion and robotics. The systems typically have a planar structure, but transforming them into complex three-dimensional (3D) frameworks could enhance and extend their various modes of operation. Here, we report a controlled, nonlinear buckling process to convert lithographically defined two-dimensional patterns of electrodes and thin films of piezoelectric polymers into sophisticated 3D piezoelectric microsystems. To illustrate the engineering versatility of the approach, we create more than twenty different 3D geometries. With these structures, we then demonstrate applications in energy harvesting with tailored mechanical properties and root-mean-square voltages ranging from 2 mV to 790 mV, in multifunctional sensors for robotic prosthetic interfaces with improved responsivity (for example, anisotropic responses and sensitivity of 60 mV N -1 for normal force), and in bio-integrated devices with in vivo operational capabilities. We note the 3D geometries, especially those with ultralow stiffnesses or asymmetric layouts, yield unique mechanical attributes and levels of functionality that would be difficult or impossible to achieve with conventional two-dimensional designs.

42 ENGINEERING↗

Digital pixel test structures implemented in a 65 nm CMOS process

The ALICE ITS3 (Inner Tracking System 3) upgrade project and the CERN EP R&D on monolithic pixel sensors are investigating the feasibility of the Tower Partners Semiconductor Co. 65 nm process for use in the next generation of vertex detectors. The ITS3 aims to employ wafer-scale Monolithic Active Pixel Sensors thinned down to 20–40 µm and bent to form truly cylindrical half barrels. Among the first critical steps towards the realisation of this detector is to validate the sensor technology through extensive characterisation both in the laboratory and with in-beam measurements. The Digital Pixel Test Structure (DPTS) is one of the prototypes produced in the first sensor submission in this technology and has undergone a systematic measurement campaign whose details are presented in this article. The results confirm the goals of detection efficiency and non-ionising and ionising radiation hardness up to the expected levels for ALICE ITS3 and also demonstrate operation at + 20 °C and a detection efficiency of 99% for a DPTS irradiated with a dose of 10 15 1 MeV n eq cm -2 . Furthermore, spatial, timing and energy resolutions were measured at various settings and irradiation levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Velocity- and pressure-based metrics for estimating strike injuries during fish passage through hydro turbines

Hydropower is a crucial source of clean and reliable energy worldwide, and its importance will continue to grow. To enhance the environmental sustainability of hydropower development and operations, it is essential to predict the strike injury rates of fish passing through turbines accurately and cost-effectively. However, conventional experiments involving a large number of live fish are still commonly conducted in practice, and previous attempts mainly focused on the dose-response relationships at an individual level or relative comparisons of biological characterization between different conditions. Thus, this study proposes two novel strike metrics based on velocity and pressure (M V and M P ) measured by the cutting-edge Sensor Fish (SF) technology, designed to quantify the biological effects of strikes and collisions between fish and rigid hydraulic structures. SF measurements and 48-hour survival rates of live fish from a study conducted at the Ice Harbor Dam on the Snake River were used to establish thresholds for the two proposed metrics. These metrics and thresholds were then applied to three additional SF studies conducted at hydropower facilities featuring Kaplan turbines within the Columbia River basin. Results from the application of the strike metrics indicate that the estimated survival rates derived from both metrics agree well with previously reported live fish survival rates. Furthermore, the study identified specific passage regions with elevated risks of fish mortality due to strikes and collisions. Overall, the proposed strike metrics present a reliable and cost-effective approach to reducing reliance on live fish and lowering costs in fish passage studies.

Biological characterization↗

Structural basis for severe pain caused by mutations in the voltage sensors of sodium channel NaV1.7

Voltage-gated sodium channels in peripheral nerves conduct nociceptive signals from nerve endings to the spinal cord. Mutations in voltage-gated sodium channel NaV1.7 are responsible for a number of severe inherited pain syndromes, including inherited erythromelalgia (IEM). Here, we describe the negative shifts in the voltage dependence of activation in the bacterial sodium channel NaVAb as a result of the incorporation of four different IEM mutations in the voltage sensor, which recapitulate the gain-of-function effects observed with these mutations in human NaV1.7. Crystal structures of NaVAb with these IEM mutations revealed that a mutation in the S1 segment of the voltage sensor facilitated the outward movement of S4 gating charges by widening the pathway for gating charge translocation. In contrast, mutations in the S4 segments modified hydrophobic interactions with surrounding amino acid side chains or membrane phospholipids that would enhance the outward movement of the gating charges. These results provide key structural insights into the mechanisms by which these IEM mutations in the voltage sensors can facilitate outward movements of the gating charges in the S4 segment and cause hyperexcitability and severe pain in IEM. Our work gives new insights into IEM pathogenesis at the near-atomic level and provides a molecular model for mutation-specific therapy of this debilitating disease.

60 APPLIED LIFE SCIENCES↗

Development of a fast framing detector for electron microscopy

A high frame rate detector system is described that enables fast real-time data analysis of scanning diffraction experiments in scanning transmission electron microscopy (STEM). This is an end-to-end development that encompasses the data producing detector, data transportation, and real-time processing of data. The detector will consist of a central pixel sensor that is surrounded by annular silicon diodes. Both components of the detector system will synchronously capture data at almost 100 kHz frame rate, which produces an approximately 400 Gb/s data stream. Low-level preprocessing will be implemented in firmware before the data is streamed from the National Center for Electron Microscopy (NCEM) to the National Energy Research Scientific Computing Center (NERSC). Live data processing, before it lands on disk, will happen on the Cori supercomputer and aims to present scientists with prompt experimental feedback. This online analysis will provide rough information of the sample that can be utilized for sample alignment, sample monitoring and verification that the experiment is set up correctly. Only a compressed version of the relevant data is then selected for more in-depth processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation measurements at ICOS ecosystem stations

Solar radiation is a prime driver of energy and carbon fluxes in natural ecosystems. Radiation measurements are essential for interpreting ecosystem scale greenhouse gases and energy fluxes as well as many other observations performed at ecosystem stations of the Integrated Carbon Observation System (ICOS). Here, we describe and explain the relevance of the radiation variables that are monitored continuously at ICOS ecosystem stations and define recommendations to perform these measurements with consistent and comparable accuracy. The measurement methodology and instruments are described including detailed technical specifications. Guidelines for instrumental set up as well as for operation, maintenance and data collection are defined considering both ICOS scientific objectives and practical operational constraints. For measurements of short-wave (solar) and long wave (infrared) radiation components, requirements for the ICOS network are based on available well-defined state-of-the art standards (World Meteorological Organization, International Organization for Standardization). For photosynthetically active radiation measurements, some basic instrumental requirements are based on the performance of commercially available sensors. Since site specific conditions and practical constraints at individual ICOS ecosystem stations may hamper the applicability of standard requirements, we recommend that ICOS develops mid-term coordinated actions to assess the effective level of uncertainties in radiation measurements at the network scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Goals, Objectives, and Requirements (GOR) of the Ground-based Nuclear Detonation Detection (GNDD) Team for the Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D)

The goal, objectives, and requirements (GOR) presented in this document define a framework for describing research directed specifically by the Ground-based Nuclear Detonation Detection (GNDD) Team of the National Nuclear Security Administration (NNSA). The intent of this document is to provide a communication tool for the GNDD Team with NNSA management and with its stakeholder community. It describes the GNDD expectation that much of the improvement in the proficiency of nuclear explosion monitoring will come from better understanding of the science behind the generation, propagation, recording, and interpretation of seismic, infrasound, hydroacoustic, and radionuclide signals and development of "game-changer" advances in science and technology.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

UPR/Mayaguez High Energy Physics

This year the University of Puerto Rico at Mayaguez (UPRM) High Energy Physics (HEP) group continued with the ongoing research program outlined in the grant proposal. The program is centered on the Compact Muon Solenoid (CMS) experiment at the proton-proton (pp) collisions at the Large Hadron Collider (LHC) at CERN in Geneva, Switzerland. The main research focus is on data analysis and on the preparation for the High Luminosity (HL) LHC or experiment detector upgrade. The physics data analysis included Higgs Doublet Search and measurement of the (1) Λ 0 b branching fraction, (2) B meson mass, and (3) hyperon θ - b lifetime. The detector upgrade included work on the preparations for the Forward Pixel (FPIX) detector Silicon Sensor Testing in a production run at Fermilab. In addition, the group has taken responsibilities on the Software Release through our former research associate Dr. Eric Brownson who acted until last December as a Level Two Offline Manager for the CMS Upgrade. In support of the CMS data analysis activities carried out locally, the UPRM group has built and maintains an excellent Tier3 analysis center in Mayaguez. This allowed us to analyze large data samples and to continue the development of algorithms for the upgrade tracking robustness we started several years ago, and we plan to resume in the near future. This project involves computer simulation of the radiation damage to be suffered at the higher luminosities of the upgraded LHC. This year we continued to serve as a source of outstanding students for the field of high energy physics. Three of our graduate students finished their MS work in May, 2014, Their theses research were on data analysis of heavy quark b-physics. All of them are currently enrolled at Ph.D. physics program across the nation. One of them (Hector Moreno) at New Mexico University (Hector Moreno), one at University of New Hampshire (Sandra Santiesteban) and one at University of Puerto Rico-Rio Piedras (Carlos Malca). The students H. Moreno and C. Malca has been directly supervised by Dr. Mendez and S. Santiesteban supervised by Dr. Ramirez. During the last 13 years, our group have graduated 23 MS students on experimental High Energy Physics data analysis and applied hardware techniques. Most of the students have been supported by DOE grants, included this grant. Since 2001, Dr. Mendez have directly supervised eleven students, Dr. Ramirez three students and the former PI (Dr. Lopez) nine students. These theses work are fully documented in the group web page (http://charma.uprm.edu). The High Energy Physics group at Mayaguez is small and presently consists of three Physics faculty members, the Senior Investigators Dr. Hector Mendez (Professor) and Dr. Juan Eduardo Ramirez (Professor), and Dr. Sudhir Malik who was just hired in July 2014. Dr. Ramirez is in charge of the UPRM Tier-3 computing and will be building the network bandwidth infrastructure for the campus, while Dr. Mendez will continues his effort in finishing the heavy quark physics data analysis and moving to work on SUSY analysis for the 2015 data. Our last grant application in 2012 was awarded only for 2013-2014. As a result our postdoc position was lost last month of March. Since then, we have hired Dr. Malik as a new faculty in order to reinforce the group and to continue our efforts with the CMS experiment. Our plan is to hire another junior faculty in the next two years to strengthen the HEP group even further. Dr. Mendez continues with QuarkNet activities involving an ever larger group of high school physics teachers from all around Puerto Rico.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nitrogen regulation of protein-protein interactions and transcript levels of GlnK PII regulator and AmtB ammonium transporter homologs in Archaea

Gene homologs of GlnK PII regulators and AmtB-type ammonium transporters are often paired on prokaryotic genomes, suggesting these proteins share an ancient functional relationship. Here, we demonstrate for the first time in Archaea that GlnK associates with AmtB in membrane fractions after ammonium shock, thus, providing a further insight into GlnK-AmtB as an ancient nitrogen sensor pair. For this work, Haloferax mediterranei was advanced for study through the generation of a pyrE2-based counterselection system that was used for targeted gene deletion and expression of Flag-tagged proteins from their native promoters. AmtB1-Flag was detected in membrane fractions of cells grown on nitrate and was found to coimmunoprecipitate with GlnK after ammonium shock. Thus, in analogy to bacteria, the archaeal GlnK PII may block the AmtB1 ammonium transporter under nitrogen-rich conditions. In addition to this regulated protein–protein interaction, the archaeal amtB-glnK gene pairs were found to be highly regulated by nitrogen availability with transcript levels high under conditions of nitrogen limitation and low during nitrogen excess. While transcript levels of glnK-amtB are similarly regulated by nitrogen availability in bacteria, transcriptional regulators of the bacterial glnK promoter including activation by the two-component signal transduction proteins NtrC (GlnG, NRI) and NtrB (GlnL, NRII) and sigma factor σ N (σ 54 ) are not conserved in archaea suggesting a novel mechanism of transcriptional control.

59 BASIC BIOLOGICAL SCIENCES↗

Magnetostrictive materials for enhanced sensors and electronic components

Magnetostriction is a property of magnetic materials that causes them to change their shape or dimensions proportional to their magnetization. Low-cost, mechanically robust magnetostrictive sensors would be valuable for a wide range of applications across the DOE and national security mission space, such as monitoring the internal conditions of pipelines, rapidly detecting high-impedance faults in power lines (e.g. trees touching power lines), or enhancing implantable systems for the human body. Dilute doping (<1 at.%) of rare earth elements (REE) has been shown to amplify the magnetostriction. Furthermore, alloy processing by rapid cooling from high temperature tends to result in texturing and therefore greater magnetostriction values, which bodes well for developing advanced manufacturing approaches significantly less expensive than single crystal growth. The goal of this effort was to develop robust, low-cost magnetostrictive materials compatible with advanced manufacturing techniques to exploit the rapid cooling of these approaches while retaining the ability to produce fully dense structures. To be useful as a sensor or actuator the coercivity of the material needs to be minimized so that there is minimal magnetic hysteresis. Employing a small scale laser powder bed fusion (L-PBF) system, specimens of Fe-Ga-Ce were built from alloy powder which had a magnetostriction of 289 ppm along the build direction and 197 ppm perpendicular to the build direction. These values are not far from the 310-350 ppm observed in single crystals of Fe-Ga. The results of the series of samples run suggest this is a very promising route for REE doping to higher levels, especially if the powders can be produced using far from equilibrium approaches such as ultrasonic atomization. The promising results from applying additive manufacturing techniques to these materials, particularly the inexpensive Fe-Al system, has potential for inexpensive high-performing magnetostrictive parts producible at large scales for low-cost sensors.

36 MATERIALS SCIENCE↗

Transition edge sensors for bolometric applications: responsivity and saturation

Microstrip-coupled transition edge sensors (TESs) combined with waveguide-horn technology produce sensitive bolometric detectors with well-defined, single-mode beam patterns and excellent polarization characteristics. These devices are now being deployed for astronomical observations. In bolometric applications, where power levels are monitored, the critical parameter that characterizes the detection is the power-to-current responsivity s{sub I}({omega}), where {omega} is the postdetection angular frequency. In real applications, such as on a ground-based telescope, the signal of interest is superimposed on a background such as the thermal emission from the atmosphere. The power emitted by the atmosphere changes slowly in time and these changes may change the responsivity of the detector. A detailed understanding of how s{sub I}({omega}) changes as a function of applied power levels and how the TES response saturates is vital for accurate calibration of astronomical data. In this paper we describe measurements of the changes in the current flowing through a TES as a function of the circuit bias and the applied power. From these measurements we calculate the efficiency of the coupling of power into the TES from a closely thermally coupled microstrip termination resistor and we determine the zero frequency responsivity s{sub I}(0) as a function of both the circuit bias and power. The variation of the responsivity is compared with predictions of a small-signal model: for the case when the loop gain L{sub I} is high, when simplifying approximations to the full solution to the electrothermal equations apply; and using the electrothermal parameters of the TES, determined by impedance measurements, as inputs to the full model solution. We find good agreement between theory and measurement in both cases in the relevant regimes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On-Sky Performance of the SPT-3G Frequency-Domain Multiplexed Readout

Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition-edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant filter. This scheme provides for the operation and readout of multiple bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin stages. The current receiver on the South Pole Telescope, SPT-3G, uses a 68x fMux system to operate its large-format camera of ~16,000 TES bolometers. We present here the successful implementation and performance of the SPT-3G readout as measured on-sky. Characterization of the noise reveals a median pair-differenced 1/f knee frequency of 33 mHz, indicating that low-frequency noise in the readout will not limit SPT-3G’s measurements of sky power on large angular scales. Measurements further show that the median readout white noise level in each of the SPT-3G observing bands is below the expectation for photon noise, demonstrating that SPT-3G is operating in the photon-noise-dominated regime.

47 OTHER INSTRUMENTATION↗

Pd/SiO 2 and AuPd/SiO 2 nanocomposite-based optical fiber sensors for H 2 sensing applications

The ability to accurately and safely monitor hydrogen concentration is of significant importance for abroad range of energy, defense, aviation, and aerospace applications with one of the most notable appli-cations being leak detection for hydrogen above the lower explosive limit. Optical-based approachesoffer significant safety advantages as compared to electrical-based sensors and Pd or AuPd-alloys arecommonly utilized as the functional sensor layer due to a well-known, characteristic, and selective inter-action with H 2 . In our work, optical fiber-based sensors comprised of Pd and AuPd alloy nanoparticleincorporated SiO 2 thin films deposited onto unclad multimode silica-based optical fiber evanescent waveabsorption spectroscopy sensing elements have been investigated. Selective, sensitive, and monotonic H 2 sensing responses have been demonstrated at levels significantly greater than the lower explosive limitin the presence of CO and O 2 near room temperature. A tendency for partial oxidation of the noble metalnanoparticles upon exposure to oxidizing atmospheres is confirmed directly through X-ray photoelectronspectroscopy, particularly at elevated temperatures. Monotonic H 2 sensing responses are also observedat elevated temperatures in cases where oxygen is not introduced into the atmosphere. However, morecomplex sensing responses in multi-component elevated temperature gas streams containing oxidizingand reducing species can be observed which likely result from oxidation and reduction of noble metalnanoparticles. Finally, these results demonstrate that the incorporation of noble metals such as Pd and Pd-alloynanoparticles into inert dielectric matrices such as SiO 2 can impart new optical sensing functionalitypotentially useful for H 2 sensing applications.

Evanescent wave absorption spectroscopy↗