Search NASA⌕ Search

SEARCH · Search NASA

Results for “loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Quantizing and sampling considerations in digital phased-locked loops

The quantizer problem is first considered. The conditions under which the uniform white sequence model for the quantizer error is valid are established independent of the sampling rate. An equivalent spectral density is defined for the quantizer error resulting in an effective SNR value. This effective SNR may be used to determine quantized performance from infinitely fine quantized results. Attention is given to sampling rate considerations. Sampling rate characteristics of the digital phase-locked loop (DPLL) structure are investigated for the infinitely fine quantized system. The predicted phase error variance equation is examined as a function of the sampling rate. Simulation results are presented and a method is described which enables the minimum required sampling rate to be determined from the predicted phase error variance equations.

Hurst, G. T.↗

Open-loop-feedback-optimal adaptive stochastic control of linear systems

This paper considers the suboptimal stochastic control of linear discrete-time dynamical systems with unknown or stochastically varying parameters. The suboptimal scheme is based upon the use of the open-loop-feedback-optimal method. The state and parameter estimates are generated by an extended Kalman filter algorithm. Numerical results for first-order systems are presented.

Ku, R.↗

Response of an all digital phase-locked loop

An all digital phase-locked loop (DPLL) is designed, analyzed, and tested. Three specific configurations are considered, generating first, second, and third order DPLL's; and it is found, using a computer simulation of a noise spike, and verified experimentally, that of these configurations the second-order system is optimum from the standpoint of threshold extension. This substantiates results obtained for analog PLL's.

Garodnick, J.↗

Closed loop analysis of manual flare and landing

This paper describes an approach to analyzing the manual flare and landing of an airplane. The basis of this approach is a mathematical model of the flare maneuver which is derived from manual landings of both real and simulated aircraft. This flare model in turn lends itself to a linear closed loop system description of the combined pilot/vehicle. Furthermore, simple Laplace transform methods can be used to map flare performance as functions of the flare maneuver. Having this link between flare maneuver and landing performance, we can estimate the pilot's ease in achieving desired levels of landing performance. Examples of this approach will be given using the results of a STOL airplane approach and landing simulation.

Heffley, R. K.↗

Fill-in binary loop pulse-torque quantizer

Fill-in binary (FIB) loop provides constant heating of torque generator, an advantage of binary current switching. At the same time, it avoids mode-related dead zone and data delay of binary, an advantage of ternary quantization.

Lory, C. B.↗

A man in the loop trajectory optimization program (MILTOP)

An interactive trajectory optimization program is developed for use in initial fixing of launch configurations. The program is called MILTOP for Man-In-the-Loop-Trajectory Optimization-Program. The program is designed to facilitate quick look studies using man-machine decision combinations to reduce the time required to solve a given problem. MILTOP integrates the equations of motion of a point-mass in 3-Dimensions with drag as the only aerodynamic force present. Any point in time at which an integration step terminates, may be used as a decision-break-point, with complete user control over all variables and routines at this point. Automatic phases are provided for different modes of control: vertical rise, pitch-over, gravity turn, chi-freeze and control turn. Stage parameters are initialized from a separate routine so the user may fly as many stages as his problem demands. The MILTOP system uses both interactively on storage scope consoles, or in batch mode with numerical output on the live printer.

Reinfields, J.↗

Digital phase-locked-loop speed sensor for accuracy improvement in analog speed controls

A digital speed control that can be combined with a proportional analog controller is described. The stability and transient response of the analog controller were retained and combined with the long-term accuracy of a crystal-controlled integral controller. A relatively simple circuit was developed by using phase-locked-loop techniques and total error storage. The integral digital controller will maintain speed control accuracy equal to that of the crystal reference oscillator.

Birchenough, A. G.↗

On modeling performance of open-loop mechanisms

A technique is presented for modeling the performance of open-loop mechanisms or systems, where performance is measured by success or failure as a function of the selected target for movement along a constrained trajectory and without corrective feedback. A modification of signal detection theory is used, which normalizes dissimilar data and indicates two independent parameters of performance: (1) discriminability and (2) optimality of the distribution of selected moves. An illustrative application is made to experimental data.

Sheridan, T. B.↗

Satellite photography of eddies in the gulf loop current

Cyclonic ocean eddies, approximately 12 to 32 kilometers in diameter, have been photographed in the eastern Gulf of Mexico by SKYLAB. Apparently caused by horizon velocity shear, these features are associated with the Gulf Loop Current, whose position was known a fortnight before and after the observation. The eddies were discovered in sunlight-enhanced patterns of streamlines on the surface, and appear to be embedded in the flow.

Maul, G. A.↗

Stability characteristics of a single-phase free convection loop

Experiments investigating the stability characteristics of a single-phase free convection loop are reported. Results of the study confirm the contention made by previous workers that instabilities near the thermodynamic critical point can occur for ordinary fluids as well as those with unusual behavior in the near-critical region. Such a claim runs counter to traditional beliefs, but it is supported by the observation of such instabilities for water at atmospheric pressure and moderate temperatures in the present work.

Creveling, H. F.↗

Manchester transition tracking loop (MTTL)

In new tracking loop, separate phase detection algorithm is incorporated for acquisition; programmed acquisition-to-track sequence includes automatic bandwidth switching. Additionally, system has very effective phase detection signal-to-noise ratio and can operate at any rate by changing master clock frequency. All system parameters remain constant.

Cellier, A.↗

Open-loop digital frequency multiplier

Monostable multivibrator is implemented by using digital integrated circuits where multiplier constant is too large for conventional phase-locked-loop integrated circuit. A 400 Hz clock is generated by divide-by-N counter from 1 Hz timing reference.

Moore, R. C.↗

Binary phase lock loops for simplified OMEGA receivers

A sampled binary phase lock loop is proposed for periodically correcting OMEGA receiver internal clocks. The circuit is particularly simple to implement and provides a means of generating long range 3.4 KHz difference frequency lanes from simultaneous pair measurements.

Burhans, R. W.↗

Feasibility study of a digital rebalance loop for a dry tuned TDF gyro

A two degrees-of-freedom (TDF) rate integrating gyro in the strapdown mode is a candidate for attitude sensing in a spacecraft navigation system, since it provides an additional axis of information for a relatively small increase in hardware complexity. A type of gyro which has not been fully exploited is of the dry, tuned, TDF design, in which the spring constant of the suspension system is effectively cancelled by the dynamic antispring of a swiveling, rotating, gimbal. The use of this unconventional gyro in a digital rebalance loop was investigated.

Coffman, D. E.↗

T-111 Rankine system corrosion test loop, volume 1

Results are given of a program whose objective was to determine the performance of refractory metal alloys in a two loop Rankine test system. The test system consisted of a circulating lithium circuit heated to 1230 C maximum transferring heat to a boiling potassium circuit with a 1170 C superheated vapor temperature. The results demonstrate the suitability of the selected refractory alloys to perform from a chemical compatibility standpoint.

Harrison, R. W.↗

A mobile planetary lander utilizing elastic loop suspension

Efforts to increase the cost effectiveness of future lunar and planetary rover missions have led to the mobile lander concept, which replaces the landing legs of a soft-lander craft with a compact mobility system of sufficient strength to withstand the landing impact. The results of a mobile lander conceptual design effort based on existing NASA-Viking '75 hardware are presented. The elastic loop concept, developed as a post-Apollo rover technology, is found to meet stringent stowage, traction, power and weight requirements.

Trautwein, W.↗

Computer program for single input-output, single-loop feedback systems

Additional work is reported on a completely automatic computer program for the design of single input/output, single loop feedback systems with parameter uncertainly, to satisfy time domain bounds on the system response to step commands and disturbances. The inputs to the program are basically the specified time-domain response bounds, the form of the constrained plant transfer function and the ranges of the uncertain parameters of the plant. The program output consists of the transfer functions of the two free compensation networks, in the form of the coefficients of the numerator and denominator polynomials, and the data on the prescribed bounds and the extremes actually obtained for the system response to commands and disturbances.

Source record↗

Transfer function verification and block diagram simplification of a very high-order distributed pole closed-loop servo by means of non-linear time-response simulation

Linear frequency domain methods are inadequate in analyzing the 1975 Viking Orbiter (VO75) digital tape recorder servo due to dominant nonlinear effects such as servo signal limiting, unidirectional servo control, and static/dynamic Coulomb friction. The frequency loop (speed control) servo of the VO75 tape recorder is used to illustrate the analytical tools and methodology of system redundancy elimination and high order transfer function verification. The paper compares time-domain performance parameters derived from a series of nonlinear time responses with the available experimental data in order to select the best possible analytical transfer function representation of the tape transport (mechanical segment of the tape recorder) from several possible candidates. The study also shows how an analytical time-response simulation taking into account most system nonlinearities can pinpoint system redundancy and overdesign stemming from a strictly empirical design approach. System order reduction is achieved through truncation of individual transfer functions and elimination of redundant blocks.

Mukhopadhyay, A. K.↗