Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Active cleaning technique for removing contamination from optical surfaces in space

An active cleaning technique for removing contaminants from optical surfaces in space was investigated with emphasis on the feasibility of using plasma exposure as a means of in-situ cleaning. The major work accomplished includes: (1) development of an in-situ reflectometer for use in conjunction with the contaminant film deposition/cleaning facility; (2) completion of Apollo Telescope Mount (ATM) filter treatment experiments to assess the effects of plasma exposure on the UV transmittance; (3) attempts to correlate the atomic oxygen flux with cleaning rate; (4) completion of in-situ butadien contamination/plasma cleaning/UV reflectance measurement experiments; (5) carbon cleaning experiments using various gases; (6) completion of silicone contamination/cleaning experiments; and (7) experiments conducted at low chamber pressures to determine cleaning rate distribution and contamination of surfaces adjacent to those being cleaned.

Shannon, R. L.↗

Effects of low-pressure air on oxygen contamination and lithium corrosion of a tantalum alloy, T-111, at 980 and 1260 C

The effects were studied of low-pressure air on contamination and corrosion in the tantalum alloy T-111/lithium system at 980 and 1260 C. Capsules of T-111 containing lithium were exposed to six vacuum levels between 1 x 10 to the 8th power and 0.0003 torr by controlled air leakage into a vacuum system. Capsules exposed at 980 C and 0.0002 torr failed from intragranular oxidation. The remainder of the capsules completed the 96-hour tests. The depth of oxygen contamination was greater at 980 C than at 1260 C. Tests made at 0.0001 and 0.00001 torr levels caused large increases in the oxygen content of the T-111. Tests at 0.000001 torr or less produced no significant contamination. No lithium corrosion of the T-111 was observed under any of the conditions.

Gahn, R. F.↗

Assessment of the probability of contaminating Mars

New methodology is proposed to assess the probability that the planet Mars will by biologically contaminated by terrestrial microorganisms aboard a spacecraft. Present NASA methods are based on the Sagan-Coleman formula, which states that the probability of contamination is the product of the expected microbial release and a probability of growth. The proposed new methodology extends the Sagan-Coleman approach to permit utilization of detailed information on microbial characteristics, the lethality of release and transport mechanisms, and of other information about the Martian environment. Three different types of microbial release are distinguished in the model for assessing the probability of contamination. The number of viable microbes released by each mechanism depends on the bio-burden in various locations on the spacecraft and on whether the spacecraft landing is accomplished according to plan. For each of the three release mechanisms a probability of growth is computed, using a model for transport into an environment suited to microbial growth.

Judd, B. R.↗

Study to define points of entry for potential contaminants in limestone aquifers

Visual examinations of both prints and transparencies from ERTS 1 and U-2 aircraft imagery provided a method for discovering possible points of entry of potential contaminants into the limestone aquifer in Madison County, Alabama. Knowledge of the locations at which contaminants could enter the aquifer is an important consideration in water quality management, particularly for regions that depend, at least partially, on ground water for their water supply. ERTS 1 imagery recorded on December 28, 1972 in the Multispectral Scanner-5 (MSS-5) and MSS-7 bands, and a false-color composite of the MSS-4 (green), MSS-5 (red), and MSS-7 (near infrared) bands were the principal materials used, along with thermography recorded by an RS-7 infrared scanner onboard a U-2 aircraft. The results of the study are discussed in detail, providing information on prominent lineations and major fracture trends which are related to aquifer contamination. Maps depicting the observations are also presented.

Doyle, F. L.↗

Test evaluation of potential heatshield contamination of an outer planet probe's gas sampling system

The feasibility of retaining the heat shield for outer planet probes was investigated as a potential source of atmospheric sample contamination by outgassing. The onboard instruments which are affected by the concept are the pressure sensor, temperature sensor, IR detector, nephelometer, and gas sampling instruments. It was found that: (1) The retention of the charred heatshield and the baseline atmospheric sampling concepts are compatible with obtaining noncontaminated atmospheric samples. (2) Increasing the sampling tube length so that it extends beyond the viscous boundary layer eliminates contamination of the atmospheric sample. (3) The potential for contamination increases with angle of attack.

Kessler, W. C.↗

Analytical study of spacecraft deposition contamination by internal reflection spectroscopy

The in-situ vacuum chamber designed around the IRE was tested under vacuum. The contamination analyzer system was tested using two liquid contaminant materials. The analysis of the contaminants on the SL-4 rendezvous window shows that the material has methyl silicone, hydroxyl, and carbonyl radicals. The analysis of the outgassing material from Shuttle TPS shows silicone as the primary product.

Mookherji, T. K.↗

Evaluation and study of advanced optical contamination, deposition, measurement, and removal techniques

A program is described to design, fabricate and install an experimental work chamber assembly (WCA) to provide a wide range of experimental capability. The WCA incorporates several techniques for studying the kinetics of contaminant films and their effect on optical surfaces. It incorporates the capability for depositing both optical and contaminant films on temperature-controlled samples, and for in-situ measurements of the vacuum ultraviolet reflectance. Ellipsometer optics are mounted on the chamber for film thickness determinations, and other features include access ports for radiation sources and instrumentation. Several supporting studies were conducted to define specific chamber requirements, to determine the sensitivity of the measurement techniques to be incorporated in the chamber, and to establish procedures for handling samples prior to their installation in the chamber. A bibliography and literature survey of contamination-related articles is included.

Linford, R. M. F.↗

Value contamination avoidance devices

Mechanical redesign methods were used to minimize contamination damage of conventional fluid components and a contamination separator device was developed for long term reusable space vehicles. These were incorporated into an existing 50.8 mm poppet valve and tested for damage tolerance in a full size open loop flow system with gaseous and liquid nitrogen. Cyclic and steady flow conditions were tested with particles of 125 to 420 micrometers aluminum oxide dispersed in the test fluids. Nonflow life tests (100,000 cycles) were made with two valve configurations in gaseous hydrogen. The redesigned valve had an acceptable cycle life and improved tolerance to contamination damage when the primary sealing surfaces were coated with thin coatings of hard plastic (Teflon S and Kynar). Analytical studies and flow testing were completed of four different versions of the separator. overall separation efficiencies in the 55-90% range were measured with these non-optimum configurations.

Endicott, D. L.↗

Contamination control in hybrid microelectronic modules. Part 3: Specifications for coating material and process controls

Resin systems for coating hybrids prior to hermetic sealing are described. The resin systems are a flexible silicone junction resin system and a flexible cycloaliphatic epoxy resin system. The coatings are intended for application to the hybrid after all the chips have been assembled and wire bonded, but prior to hermetic sealing of the package. The purpose of the coating is to control particulate contamination by immobilizing particles and by passivating the hybrid. Recommended process controls for the purpose of minimizing contamination in hybrid microcircuit packages are given. Emphasis is placed on those critical hybrid processing steps in which contamination is most likely to occur.

Himmel, R. P.↗

Molecular contamination study by interaction of a molecular beam with a platinum surface

The capability of molecular beam scattering from a solid surface is analyzed for identification of molecular contamination of the surface. The design and setup of the molecular beam source and the measuring setup for the application of a phase sensitive measuring technique for the determination of the scattered beam intensity are described. The scattering distributions of helium and nitrogen molecular beams interacting with a platinum surface were measured for different amounts of contamination from diffusion pump oil for surface temperatures ranging from 30 to 400 C. The results indicate the scattering of molecular beams from a platinum surface is a very sensitive method for detecting surface contamination.

Nuss, H. E.↗

Optimization of contaminated oxide inversion layer solar cell

Contaminated oxide cells have been fabricated with efficiencies of 8.6% with values of I sub sc = 120 ma, V sub oc = .54 volts, and curve factor of .73. Attempts to optimize the fabrication step to yield a higher output have not been successful. The fundamental limitation is the inadequate antireflection coating afforded by the silicon dioxide coating used to hold the contaminating ions. Coatings of SiO, therefore, were used to obtain a good antireflection coating, but the thinness of the coatings prevented a large concentration of the contaminating ions, and the cells was weak. Data of the best cell were .52 volts V sub oc, 110 ma I sub sc, .66 CFF and 6.7% efficiency.

Call, R. L.↗

Preliminary study of contaminant particulates around Skylab

Techniques originally developed for the Skylab T025 contamination experiment were applied to S052 white-light coronagraph data in a preliminary study to investigate particulates around Skylab. Periods were selected which contained some contamination, even though there were no apparent dumps or vents during these periods. Velocity and size distributions were determined from optical data for particles within 200 meters of the spacecraft. Both photographic (61 particle tracks) and video (34 particles) observations yield an upper limit on particle radius of 100 micrometers. Selected photometric data from the S073 zodiacal light experiment during mission SL-2 were also examined for evidence of contamination.

Schuerman, D. W.↗

Monopropellant thruster exhaust plume contamination measurements

The potential spacecraft contaminants in the exhaust plume of a 0.89N monopropellant hydrazine thruster were measured in an ultrahigh quartz crystal microbalances located at angles of approximately 0 deg, + 15 deg and + or - 30 deg with respect to the nozzle centerline. The crystal temperatures were controlled such that the mass adhering to the crystal surface at temperatures of from 106 K to 256 K could be measured. Thruster duty cycles of 25 ms on/5 seconds off, 100 ms on/10 seconds off, and 200 ms on/20 seconds off were investigated. The change in contaminant production with thruster life was assessed by subjecting the thruster to a 100,000 pulse aging sequence and comparing the before and after contaminant deposition rates. The results of these tests are summarized, conclusions drawn, and recommendations given.

Baerwald, R. K.↗

NASA charging analyzer program: A computer tool that can evaluate electrostatic contamination

A computer code, the NASA Charging Analyzer Program (NASCAP), was developed to study the surface charging of bodies subjected to geomagnetic substorm conditions. This program will treat the material properties of a surface in a self-consistent manner and calculate the electric fields in space due to the surface charge. Trajectories of charged particles in this electric field can be computed to determine if these particles enhance surface contamination. A preliminary model of the Spacecraft Charging At The High Altitudes (SCATHA) satellite was developed in the NASCAP code and subjected to a geomagnetic substorm environment to investigate the possibility of electrostatic contamination. The results indicate that differential voltages will exist between the spacecraft ground surfaces and the insulator surfaces. The electric fields from this differential charging can enhance the contamination of spacecraft surfaces.

Stevens, N. J.↗

Effect of filtration on rolling-element-bearing life in contaminated lubricant environment

Fatigue tests were conducted on groups of 65 millimeter-bore ball bearings under four levels of filtration with and without a contaminated MIL-L-23699 lubricant. The baseline series used noncontaminated oil with 49 micron absolute filtration. In the remaining tests contaminants of the composition found in aircraft engine filters were injected into the filter's supply line at a constant rate of 125 milligrams per bearing-hour. The test filters had absolute particle removal ratings of 3, 30, 49, and 105 microns (0.45, 10, 30, and 70 microns nominal), respectively. Bearings were tested at 15,000 rpm under 4580 newtons radial load. Bearing life and running tract condition generally improved with finer filtration. The 3 and 30 micron filter bearings in a contaminated lubricant had statistically equivalent lives, approaching those from the baseline tests. The experimental lives of 49 micron bearings were approximately half the baseline bearing's lives. Bearings tested with the 105 micron filter experienced wear failures. The degree of surface distress, weight loss, and probable failure mode were found to be dependent on filtration level, with finer filtration being clearly beneficial.

Loewenthal, S. H.↗

Electric discharge for treatment of trace contaminants

A radio frequency glow discharge reactor is described for removing trace oxidizable contaminants from an oxygen bearing atmosphere. The reaction chamber is defined by an inner metal electrode facing a dielectric backed by an outer conductive electrode. In one embodiment, a conductive liquid forms the conductor of an outer electrode and cools the dielectric. A resonator coupled to a variable radio frequency source generates the high voltages for creating a glow discharge in the chamber at a predetermined pressure whereby the trace contaminants are oxidized into a few simple non-toxic products that may be easily recovered. The corresponding process for removal of trace contaminants from an oxygen-bearing atmosphere with high efficiency independent of the concentration level is also disclosed.

Flamm, D. L.↗

Experimental investigation of contamination prevention techniques for a cryogenically cooled telescope in earth-orbit

A one-tenth scale model of the Shuttle Infrared Telescope Facility (SIRTF) was constructed to experimentally investigate the feasibility of a helium purge system to reduce contamination on cryogenic surfaces. The on-orbit ambient contaminant environment was simulated with ion beams of N2(+), O(+) and H2O(+). Helium was injected into the model telescope at the simulated plane of the primary optics using two techniques: a) porous plug, b) nozzle. Helium flow rates and telescope pressures were varied to determine the purge effectiveness against potential contaminants. Based on the subscale results, a 90% reduction in O, N2, and H2O at the primary optics of the SIRTF can be obtained using 20 K helium with a pressure of .00001 torr and a flow rate of less than 0.1 g/s.

Hetrick, M. A.↗

Assessment of shuttle payloads gaseous environment contamination and its control

A prediction is given of the in-orbit gaseous environment and the contamination it could produce on cryogenic and room temperature surfaces of payloads in the shuttle bay. The time varying environment was obtained by the superposition of the calculated shuttle environment for a discrete time and payload induced environments measured in large space chambers. Representative contaminant surface accretions were calculated for flights 1 week and 1 month long for payloads having the largest source of outgassing and an orbit of 200 km. A number of calculations were based on the magnitude of the sources, the molecular natures, the decay rate with time, the sticking coefficients, the view factors, and the temperatures of the surfaces being contaminated. Significant results are reported.

Scialdone, J. J.↗