Advanced High Torque Density Magnetically Geared Generator

The objective of this research project was to investigate the fundamental torque density limitations of multistage flux focusing magnetic gears and magnetically geared direct-drive generators for wind turbines. Magnetic gears create non-contact speed amplification by modulating the air-gap magnetic field harmonics created by magnetic rotors. By integrating a stator into the magnetic gear structure a very high torque density direct-drive generator can be created. Magnetic geared systems offer unique capabilities that are currently not available using existing mechanically geared systems, such as overload protection. Magnetic gears also offer the potential for higher reliability, higher efficiency and quieter operation than is currently achievable using a mechanically geared generator. By increasing reliability and design life magnetic gears could decrease the overall life-cycle costs when compared with equivalent mechanical or direct-drive drivetrains. This research project investigated and experimentally testing two sub-scale magnetic gearboxes (0.12 m diameter) and two large diameter magnetic gearboxes (0.56m and 0.63m diameter). The goal of the project was to demonstrate a torque density >300Nm/L for a multistage magnetic gearbox with integrated stator. A nested multistage magnetic gear structure was first proposed and studied. However, it was shown that the nested design greatly increased mechanical complexity and therefore a two-stage series typology was utilized. A multi-stage magnetic gear with a 59:1 gear ratio was successfully experimentally tested. A peak torque of 4.25 kN·m was measured and this resulted in an overall active region torque density of 141 N·m/L (when including support rings). The torque density was significantly reduced from what was computed using 2-D electromagnetic analysis. This reduction was due to the 3-D edge effects, increased power losses and the inclusion of additional mechanical support rings as well as other mechanical assembly design changes. At large diameters contiguous lamination parts could not be fabricated and so a segmented laminated rotor design had to be used. This reduced the mechanical strength of the design when compared to small diameter magnetic gears and resulted in the need for the addition of mechanical support rings to prevent deflection. The final experimentally tested design also had a high torque ripple and the power loss within the magnetic gear did not change significantly with load. This therefore resulted in the efficiency being high only at peak loads. Despite not experimentally achieving the 2-D calculated high torque density the analysis has shown that the problems encountered with the scaling can be overcome with careful design changes. For example, understanding the unique mechanical deflection requirements during the electromagnetic design of the large diameter magnetic gears is key to achieving both a high torque density based on the electromagnetic analysis and a high torque density based on the mechanical support needs. Furthermore, ensuring that end plates are made of non-conductive material and minimizing other conductive support elements within the magnetic structure is a key requirement for reducing eddy current losses. In summary, if the mechanical design can be made more robust and eddy current loss mitigation strategies are used in the mechanical design phase then the magnetic gear is capable of being scaled up whilst operating at a very high torque density. This will then enable it to be potentially performance and cost competitive with alternative direct-drive and mechanically geared wind turbine drivetrains.

17 WIND ENERGY↗

Using the Dimensionality Reduction (DR) Approach to Treat Singular and Near-Singular Source and Test Integrals on Triangles for Moment Methods

Recently, the authors presented preliminary results of an initial study of a dimensional reduction scheme for treating (near-)singular integrals (D. R. Wilton et al., “Dimensionality Reduction Approach for Treating Singular and Near-Singular Multidimensional Integrals of Electromagnetics,” 2022 URSI USNC National Radio Science Meeting, Boulder, CO, Jan. 2022). The approach reported there refined and extended several ideas appearing in a recent paper (R. R. Chang, Z. Wang, and Q. Xie, "Fast Convergent Quadrature Method for Evaluating the RWG- and SWG-Related Convolutional Integrals," IEEE Trans. Antennas Propagat., 69, Dec. 2021). That paper reported a curated collection of important, previously published results all leading to very efficient and accurate line integral methods for handling the most common (near-)singular integrals associated with triangles and tetrahedrons with RWG and SWG bases, respectively. Our contributions provided a simpler exposition as well as a more unified, systematic, and robust overall framework for deriving and applying the approach. This presentation further elucidates our extensions to the approach and broadens our initial study to examine the convergence behaviors of the various potential forms over a wider range of triangular source element shape and observation point parameters for various smoothing transformations; we also examine convergence, not just at the subtriangle level, but also overcomplete triangles. In addition, we investigate the application of the recently reported “vertex function” concept to develop faster converging test integrals (Rivero et al., “Acceleration of the Surface Test Integral Using Vertex Functions,” 2021 IEEE Int’l Symp. Ant. Propagat. and USNC-URSI Rad. Sci. Meeting,” Singapore, 4-10 Dec. 2021). Combining these separate schemes has the potential for yielding a near-optimal approach for accurately evaluating singular and near-singular integrals for moment methods.

Singular Integrals↗

Pseudoscalar Perturbations and Polarization of the Cosmic Microwave Background

We show that models of new particle physics containing massless pseudoscalar fields superweakly coupled to photons can be very efficiently probed with CMB polarization anisotropies. The stochastic pseudoscalar fluctuations generated during inflation provide a mechanism for converting E-mode polarization to B-mode during photon propagation from the surface of last scattering. The efficiency of this conversion process is controlled by the dimensionless ratio H/(2pif{sub a}), where H is the Hubble scale during inflation, and f{sub a}{sup -1} is the strength of the pseudoscalar coupling to photons. The current observational limits on the B mode constrain this ratio to be less than 0.07, which in many models of inflation translates to a sensitivity to f{sub a} exceeding 10{sup 14} GeV, which surpasses other tests.

79 ASTRONOMY AND ASTROPHYSICS↗

Fabrication and Testing of a Stainless Steel Quartz Coaxial Cable Structure for High Temperature Measurement

This paper presents a stainless-steel quartz coaxial cable structure for distributed sensing of high temperatures. The coaxial cable sensor uses stainless steel as the inner and outer conductors and quartz as the insulator in order to achieve mechanical strength and temperature resilience. Girdle-shaped reflectors are fabricated on the quartz tubing by CNC grinding and CO 2 laser resurfacing. The sensor operates by measuring the temperature dependent change in the effective electromagnetic length between the two adjacent reflectors on the quartz tubing. A retaining collar is fabricated at the tip of the quartz tubing by 3D printing and laser resurfacing to secure the connection between the sensor and the signal cable. The prototype sensor was tested for high temperature measurements up to 600°C, and the performance characteristics of the sensor such as sensitivity, resolution uncertainty, repeatability, and stability were estimated based on the test results.

Jiao, Xinyu↗

Estimation of High-Altitude Electromagnetic Pulse Signal Leakage into Power Generation Facilities: Simulations and Measurements

The coupling of early-time high-altitude electromagnetic pulse signals into a power generation facility was investigated. This study encompasses both electromagnetic simulation and on-site experimental efforts that are relevant to shielding effectiveness estimation with a passive technique. As an initial step in understanding the attenuation models involved, simulations were carried out as a function of frequency, building properties, and signal incidence angle. Testing was then performed at the US Department of Energy’s Oak Ridge National Laboratory campus to identify the equipment needed for signal collection and to fine-tune the experimental procedure. Finally, as an application of the models and methods presented, measurements were conducted at a power generation plant to derive the field transfer functions and coupled high-altitude electromagnetic pulse waveforms for various locations within the facility.

42 ENGINEERING↗

Alternative Setup for Long-Duration Low-Duty-Cycle 600°C Ambient Testing of SiC Integrated Circuits

A scalable, compact oven testbed system for simultaneously evaluating a multitude of high temperature integrated circuits (ICs) for prolonged operating times of up to 600 °C has been prototyped. The new testbed system enables long-duration high temperature testing in sufficient statistical quantities consistent with standard aerospace electronics engineering standards. This setup is comprised of multiple compact ovens housing chips or packages mounted to ceramic circuit boards. Each oven is a compact 15.2 cm length by 15.2 cm width by 12.7 cm depth with a maximum 400 Watts of heating power. The custom-made silicon oxide ceramic heating block inside each oven is based on a 3D printed design adapted for the easy insertion of the IC device under test (DUT). This innovative design provides the quick insertion of ICs with or without a ceramic package into a 600 °C environment by utilizing a movable 11.43 cm long ceramic substrate with electrical traces extending from the oven hot zone to external standard plastic-based board connectors. Another key oven design feature is the minimization of the DUT exposure to electromagnetic interference (EMI) by utilizing a filtered DC power source to reduce heating element noise. Additionally, the ovens can be configured in a parallel arrangement allowing global data monitoring over a single industrial RS422 serial port. This feature is important for scaling up to test multiple ICs semi-simultaneously. A USB serial port is provided to independently control the operating parameters of each oven such as the oven target temperature and oven ramp rate. The oven temperature can reach up to 600 °C with a confirmed +/- 4 °C maximum deviation across the test zone region. The ramp rate can be programmed from 1 °C/minute up to 10 °C/minute. Furthermore, a programmable switchboard is used to interface with the DUT. This switchboard comprises a National Instruments Peripheral Component Interconnect eXtension for Instrumentation (NI PXI) system and a breakout board to send and receive power, analog or digital test signals. By using this unique oven testbed system, a variety of ICs can now be tested in parallel using the same test components configured for a diverse set of requirements.

DC Powered Oven↗

Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2°, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

47 OTHER INSTRUMENTATION↗

Test of local position invariance using a double-cavity laser system

The results of testing local position invariance, which is a constituent of the Einstein equivalence principle, in a 'null' gravitational redshift experiment are reported. The processing of the experimental data collected during the five-month operation of a double-c avity laser system, where one cavity operates in the free generation mode and the frequency of the second cavity is stabilized with the nonlinear ultranarrow absorption resonance of the methane molecule, has confirmed the universality of the gravitational redshift law at a level of 0.9%. This result almost doubly improves the best existing accuracy (1.7%) of testing local position invariance for clocks of different physical natures.

74 ATOMIC AND MOLECULAR PHYSICS↗

On-site Real-Time Inspection System for Pump-impeller using X-band Linac X-ray Source

The methods of nondestructive testing (NDT) are generally ultrasonic, neutron, eddy-current and X-rays, NDT by using X-rays, in particular, is the most useful inspection technique having high resolution. We can especially evaluate corroded pipes of petrochemical complex, nuclear and thermal-power plants by the high energy X-ray NDT system. We develop a portable X-ray NDT system with X-band linac and magnetron. This system can generate a 950 keV electron beam. We are able to get X-ray images of samples with 1 mm spatial resolution. This system has application to real time impeller inspection because linac based X-ray sources are able to generate pulsed X-rays. So, we can inspect the rotating impeller if the X-ray pulse rate is synchronized with the impeller rotation rate. This system has application in condition based maintenance (CBM) of nuclear plants, for example. However, 950 keV X-ray source can only be used for thin tubes with 20 mm thickness. We have started design of a 3.95 MeV X-band linac for broader X-ray NDT application. We think that this X-ray NDT system will be useful for corrosion wastage and cracking in thicker tubes at nuclear plants and impeller of larger pumps. This system consists of X-band linac, thermionic cathode electron gun, magnetron and waveguide components. For achieving higher electric fields the 3.95 MeV X-band linac structure has the side-coupled acceleration structure. This structure has more efficient acceleration than the 950 keV linac with alternating periodic structure (APS). We adopt a 1.3 MW magnetron for the RF source. This accelerator system is about 30 cm long. The beam current is about 150 mA, and X-ray dose rate is 10 Gy at 1 m/500 pps. In this paper, the detail of the whole system concept and the electromagnetic field of designed linac structure will be reported.

43 PARTICLE ACCELERATORS↗

TESTING OF NB{sub 3}SN QUADRUPOLE COILS USING MAGNETIC MIRROR STRUCTURE

This paper describes the design and parameters of a quadrupole mirror structure for testing the mechanical, thermal and quench performance of single shell-type superconducting quadrupole coils at field, current and force levels similar to that of real magnet. The concept was experimentally verified by testing two quadrupole coils, previously used in quadrupole models, in the developed mirror structure in the temperature range from 4.5 to 1.9 K. The coils were instrumented with voltage taps, heaters, and strain gauges to monitor their mechanical and thermal properties and quench performance. A new quadrupole coil made of improved Nb{sub 3}Sn RRP-108/127 strand and cable insulation based on E-glass tape was also tested using this structure. The fabrication and test results of the quadrupole mirror models are reported and discussed.

36 MATERIALS SCIENCE↗

Proposal for testing the electric Aharonov-Bohm effect with superconductors

The phase of the wave function of charged matter is sensitive to the value of the electric potential, even when the matter never enters any region with nonvanishing electromagnetic fields. Despite its fundamental character, this archetypal electric Aharonov-Bohm effect has evidently never been observed. Here, we propose an experiment to detect the electric potential through its coupling to the superconducting order parameter. A potential difference between two superconductors will induce a relative phase shift that is observable via the DC Josephson effect even when no electromagnetic fields ever act on the superconductors, and even if the potential difference is later reduced to zero. This is a type of electromagnetic memory effect, and would directly demonstrate the physical significance of the electric potential.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nondestructive testing techniques used in analysis of honeycomb structure bond strength

DOT /Driver-Displacement Oriented Transducer/, applicable to both lap shear type application and honeycomb sandwich structures, measures the displacement of the honeycomb composite face sheet. It incorporates an electromagnetic driver and a displacement measuring system into a single unit to provide noncontact bond strength measurements.

Erdman, D. C.↗

Planck 2013 results. IX. HFI spectral response

The Planck High Frequency Instrument (HFI) spectral response was determined through a series of ground based tests conducted with the HFI focal plane in a cryogenic environment prior to launch. The main goal of the spectral transmission tests was to measure the relative spectral response (includingthe level of out-of-band signal rejection) of all HFI detectors to a known source of electromagnetic radiation individually. This was determined by measuring the interferometric output of a continuously scanned Fourier transform spectrometer with all HFI detectors. As there is no on-board spectrometer within HFI, the ground-based spectral response experiments provide the definitive data set for the relative spectral calibration of the HFI. Knowledge of the relative variations in the spectral response between HFI detectors allows for a more thorough analysis of the HFI data. The spectral response of the HFI is used in Planck data analysis and component separation, this includes extraction of CO emission observed within Planck bands, dust emission, Sunyaev-Zeldovich sources, and intensity to polarization leakage. The HFI spectral response data have also been used to provide unit conversion and colour correction analysis tools. While previous papers describe the pre-flight experiments conducted on the Planck HFI, this paper focusses on the analysis of the pre-flight spectral response measurements and the derivation of data products, e.g. band-average spectra, unit conversion coefficients, and colour correction coefficients, all with related uncertainties. Verifications of the HFI spectral response data are provided through comparisons with photometric HFI flight data. This validation includes use of HFI zodiacal emission observations to demonstrate out-of-band spectral signal rejection better than 10 8 . The accuracy of the HFI relative spectral response data is verified through comparison with complementary flight-data based unit conversion coefficients and colour correction coefficients. Furthermore, these coefficients include those based upon HFI observations of CO, dust, and Sunyaev-Zeldovich emission. General agreement is observed between the ground-based spectral characterization of HFI and corresponding in-flight observations, within the quoted uncertainty of each; explanations are provided for any discrepancies.

79 ASTRONOMY AND ASTROPHYSICS↗

TIME-SEQUENCED X-RAY OBSERVATION OF A THERMAL EXPLOSION

The evolution of a thermally-initiated explosion is studied using a multiple-image x-ray system. HMX-based PBX 9501 is used in this work, enabling direct comparison to recently-published data obtained with proton radiography [1]. Multiple x-ray images of the explosion are obtained with image spacing of ten microseconds or more. The explosion is simultaneously characterized with a high-speed camera using an interframe spacing of 11 mus. X-ray and camera images were both initiated passively by signals from an embedded thermocouple array, as opposed to being actively triggered by a laser pulse or other external source. X-ray images show an accelerating reacting front within the explosive, and also show unreacted explosive at the time the containment vessel bursts. High-speed camera images show debris ejected from the vessel expanding at 800-2100 m/s in the first tens of mus after the container wall failure. The effective center of the initiation volume is about 6 mm from the geometric center of the explosive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Positive-Sequence Modeling of Droop-Controlled Grid-Forming Inverters for Transient Stability Simulation of Transmission Systems

Here, this paper describes a positive-sequence model to represent two widely reported droop-controlled grid-forming inverters for bulk power systems simulation study. Methods of how to develop the equivalent voltage source behind impedance to represent inverters with and without inner control loops, modeling of P-f and Q-V droop controls, active and reactive power limiting modeling, and modeling of fault current limiting controls are described in detail. The model is implemented in commercially available positive-sequence simulation tools and compared with detailed electromagnetic transient models in both a single-grid-forming-inverter infinite-bus system and a modified IEEE 39-bus system. Finally, the model is tested on the full US Western Electricity Coordinating Council (WECC) system. Study results show that the model has a good level of accuracy compared to the detailed EMT models, and at the same time also achieves a high computational efficiency, which is suitable for the bulk power system simulation study.

42 ENGINEERING↗

WISE-CASING: Frequency Domain EM Data from Cymric Oil Field, CA

Cymric oil field frequency domain electromagnetic (FEM) data with two parts of data labeled Part 1 and Part 2. Part 1 utilizes an electrical source line parallel to the receiver line, while Part 2 utilizes an electrical source line at a 75 deg angle to the receiver line. Data are plotted and compared to numerically modeled data to observe electric field response to well structure. In two configuration files are diagrams of the experiment layout.

15 GEOTHERMAL ENERGY↗

QCD and Standard Model Studies

Our group has focused on using jets in STAR to investigate the longitudinal and transverse spin structure of the proton. We performed measurements of the longitudinal double-spin asymmetry for inclusive jet production that provide the strongest evidence to date that the gluons in the proton with x>0.05 are polarized. We also made the first observation of the Collins effect in pp collisions, thereby providing an important test of the universality of the Collins fragmentation function and opening a new tool to probe quark transversity in the proton. Our studies of forward rapidity electromagnetic jet-like events raise serious question whether the large transverse spin asymmetries that have been seen for forward inclusive hadron production arise from conventional 2 → 2 parton scattering. This is the final technical report for DOE Grant DE-FG02-93ER40765. It covers activities during the period January 1, 2015 through November 30, 2016.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Common Information Model for Electromagnetic Transients (CIM for EMT): CRADA 533 [Abstract only}

The control and protection functions of inverter-based resources (IBR) have raised concerns with bulk system reliability. Most of the current interest lies with solar photovoltaic generation but increasing amounts of storage would pose the same risks. Newer North American Electric Reliability Corporation (NERC) guidelines call for electromagnetic transient (EMT) studies of IBR and recommend that transmission operators collect distributed energy resource (DER) data to support such modeling. IEEE Standard P2800.1 is defining tests for model parameterization, so good model data should become available from inverter vendors. (EMT studies also apply to large power transformer reliability, and transformer vendors can provide EMT models.) Utilities don’t currently have the rest of the bulk system represented for EMT studies at large scale. An International Electrotechnical Commission (IEC) standard Common Information Model (CIM) provides a way of supporting these detailed models from physical asset data, e.g., conductors, towers, transformer data sheets, control block diagrams, while avoiding software vendor lock-in. CIM-for-EMT, with proposed schema extensions and open-source converters, provides a way to exchange EMT data between organizations and tools. This project leverages Office of Electricity (OE) funding of CIM-for-EMT code base through the GridAPPS-DTM project, and of GridPACKTM (parallelized transmission solver), for interoperability testing in CIM-for-EMT. The project also leverages partner PGSTech investments in EMTP® interoperability with CIM.