Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62

Error in Dasibi flight measurements of atmospheric ozone due to instrument wall-loss

Theory suggests that in laminar flow the percent loss of a trace constituent to the walls of a measuring instrument varies as P to the -2/3, where P is the total gas pressure. Preliminary laboratory ozone wall-loss measurements confirm this P to the -2/3 dependence. Accurate assessment of wall-loss is thus of particular importance for those balloon-borne instruments utilizing laminar flow at ambient pressure, since the ambient pressure decreases by a factor of 350 during ascent to 40 km. Measurements and extrapolations made for a Dasibi ozone monitor modified for balloon flight indicate that the wall-loss error at 40 km was between 6 and 30 percent and that the wall-loss error in the derived total ozone column-content for the region from the surface to 40 km altitude was between 2 and 10 percent. At 1000 mb, turbulence caused an order of magnitude increase in the Dasibi wall-loss.

Ainsworth, J. E.↗

Holdup Measures on an SRNL Mossbauer Spectroscopy Instrument

Gamma-ray holdup measurements of a Mossbauer spectroscopy instrument are described and modeled. In the qualitative acquisitions obtained in a low background area of Savannah River National Laboratory, only Am-241 and Np-237 activity were observed. The Am-241 was known to be the instrumental activation source, while the Np-237 is clearly observed as a source of contamination internal to the instrument. The two sources of activity are modeled separately in two acquisition configurations using two separate modeling tools. The results agree well, demonstrating a content of (1980 {+-} 150) {mu}Ci Am-241 and (110 {+-} 50) {mu}Ci of Np-237.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Progress in speckle-shift strain measurement

The Instrumentation and Control Technology Division of the Lewis Research Center has been developing an in-house capability to make one dimensional and two dimensional optical strain measurements on high temperature test specimens. The measurements are based on a two-beam speckle-shift technique. The development of composite materials for use in high temperature applications is generating interest in using the speckle-shift technique to measure strains on small diameter fibers and wires of various compositions. The results of preliminary speckle correlation tests on wire and fiber specimens are covered, and the advanced system currently under development is described.

Lant, Christian T.↗

Far-infrared emissivity measurements of reflective surfaces

An instrument developed to measure the emissivity of reflective surfaces by comparing the thermal emission of a test sample to that of a reference surface is reported. The instrument can accurately measure the emissivity of mirrors made from lightweight thermally insulating materials such as glass and metallized carbon fiber reinforced plastics. Far infrared measurements at a wavelength of 165 micrometers are reported. The instrument has an absolute accuracy of Delta epsilon = 9 x 10(exp -4) and can reproducibly measure an emissivity of as small as 2 x 10(exp -4) between flat reflective surfaces. The instrument was used to measure mirror samples for balloon-borne and spaceborne experiments. An emissivity of (6.05 +/- 1.24) x 10(exp -3) was measured for gold evaporated on glass, and (6.75 +/- 1.17) x 10(exp -3) for aluminum evaporated on glass.

Xu, J.↗

A new stereolithography experimental porous flow device

A new method for constructing laboratory-scale porous media with increased pore-level variabilities for two-phase flow experiments is presented here. These devices have been created with stereolithography directly on glass, thus improving the stability of the model created with this precision rapid construction technique. The method of construction and improved parameters are discussed in detail, followed by a brief comparison of two-phase drainage results for air invasion into the water-saturated porous medium. Flow through the model porous medium is shown to substantiate theoretical fractal predictions.

47 OTHER INSTRUMENTATION↗

A small-volume, high-throughput approach for surface tension and viscosity measurements of liquid fuels

An ongoing effort looking at bioblendstocks to function as drop-in replacements or blending components for gasoline has identified a large number of candidate fuels. This work documents an approach for rapid screening of candidate fuels using relatively small sample sizes ($\mathcal{O}(\mu\,{\rm l})$) that targets two key physical properties of liquid fuels—surface tension and viscosity. The approach utilizes shape oscillation dynamics of single droplets generated by a piezo-electric device and their decay over time. Strobed imaging of the oscillation process is used along with image processing, edge detection, and data analysis to capture the decay of the oscillation over time. The time constant of the decay process along with oscillation frequency are then used to estimate viscosity and surface tension using a theory for small amplitude droplet oscillations. Measurements are obtained for primary reference fuels (isooctane and n-heptane) as well as candidate fuels from four bio-derived functional groups of interest. Measurement results for surface tension and viscosity are correlated with literature data as well as measurements from standard reference instruments. The measurement results show that the droplet oscillation based approach is capable of reproducing surface tension and viscosity values for the tested fuels within deviations of 7% and 13% respectively from literature data. Results are obtained using an average of 5 µl per fuel within about 20 s, thus demonstrating a small-volume, high-throughput approach that can be used for screening of candidate bioblendstock fuels.

09 BIOMASS FUELS↗

Research analysis of Space Shuttle Orbiter entry aerothermodynamic flight data at the NASA Langley Research Center

The methods used to analyze the aerothermodynamic data gathered from the Shuttle protoflights are reviewed. Trajectory and atmospheric reconstruction allow an accurate definition of the freestream environment through which the Shuttle has flown. The reconstructions, combined with aerodynamic coefficient and convective heating rate determinations, provide predictive capability for comparison with future flights. Data are acquired by operational instrumentation (12,000 parameters), development flight instrumentation (4500 measurements), and Orbiter experiments instrumentation; tracking and meteorological data are also included in the analyses. The aerothermodynamic and aerodynamic technology base for large, winged, lifting body entry vehicles is being expanded by the analysis efforts. Sensor locations on the Shuttle and data management techniques are described.

Throckmorton, D. A.↗

Measuring Tracking Accuracy of CCD Imagers

Tracking accuracy and resolution of charge-coupled device (CCD) imaging arrays measured by instrument originally developed for measuring performance of star-tracking telescope. Operates by projecting one or more artifical star images on surface of CCD array, moving stars in controlled patterns, and comparing star locations computed from CCD outputs with those calculated from step coordinates of micropositioner.

Stanton, R. H.↗

Non-coincident Inter-instrument Comparisons of Ozone Measurements Using Quasi-conservative Coordinates

Ozone measurements from ozonesondes, AROTAL, DIAL, and POAM III instruments during the SOLVE-2/VINTERSOL period are composited in a time-varying, flow-following quasi-conservative (PV-6) coordinate space; the resulting composites from each instrument are mapped onto the other instruments locations and times. The mapped data are then used to intercompare data from the different instruments. Overall, the four data sets are found to be in good agreement. AROTAL shows somewhat lower values below 16 km, and DIAL has a positive bias at the upper limits of its altitude range. These intercomparisons are consistent with those obtained from more conventional near-coincident profiles, where available. Although the PV-theta mapping technique entails larger uncertainties of individual profile differences compared to direct near-coincident comparisons, the ability to include much larger numbers of comparisons can make this technique advantageous.

Lait, L. R.↗

Instrumental Biases in Ionospheric Measurement Derived from GPS Data

Line-of-sight ionosphere measurements derived from differencing dual frequency GPS range data are corrupted by instrumental biases in both receiver and GPS satellite transmitters due to hardware delays in the L1 and L2 signal paths. Using a global ionospheric shell model to fit GPS based ionospheric delay data from a world wide network of 30 to 40 receivers, we can estimate, with a single fit, satellite biases for the entire GPS constellation and receiver biases for all the uncalibrated receivers.

GPS↗

Large volume high-pressure cell with supported moissanite anvils

The recently developed moissanite anvil cell (MAC) has become a useful device for achieving both high-pressure and large sample volume in an anvil cell. We describe two improvements in the basic design of the MAC. First, the loading environment has been optimized by centering the load. Second, a variety of supported systems have been examined to provide anvil stability at high loads with large anvils. Sample volumes that are nearly three orders magnitude greater than allowed by conventional diamond anvil cells can be pressurized and characterized at {approx}50 GPa.

47 OTHER INSTRUMENTATION↗

Improved Measurement of Coherence in Presence of Instrument Noise

A method for correcting measured coherence spectra for the effect of incoherent instrument noise has been developed and demonstrated. Coherence measurements are widely used in engineering and science to determine the extent to which two signals are alike. The signals may come from two different sources or from the same source at different times. The coherence of time-lagged signals from a single source is an excellent indication of the effective lifetime of the signal components as a function of their frequency. Unfortunately, incoherent instrument noise will bias the measurement to lower values and may lead the user of the data to false conclusions about the longevity of significant features. The new method may be used whenever both the signal and noise power spectra are known and the noise is incoherent both with the signal and with itself at the applicable time delays. It provides a corrected coherence spectrum given the measured coherence and power spectra. For powerlaw signal spectra and instrumental white noise, the correction formula takes a particularly simple and explicit form. Since many geophysical signals exhibit powerlaw behavior and most instrument noise spectra approach white noise, the simplified form should be widely applicable in meteorology, oceanography, geology, and planetary geophysics.

Merceret, Francis J.↗

An instrument for spatial conductivity measurements of high Tc superconducting (HTSC) materials

High T(sub c) Superconducting (HTSC) thin films are suggested for use in a number of aerospace applications such as an IR bolometer and as electromagnetic shielding. As part of its flight assurance role, the Materials Branch of the Goddard Space Flight Center has initiated development of an instrument capable of measuring variations in conductivity for flat samples using an eddy current testing device and an X-Y positioning table. This instrument was used to examine bulk HTSC samples. System changes that would enable characterization of thin film materials are discussed.

Vansant, T.↗

Troposphere-Thermosphere Tidal Coupling as Measured by the SABER Instrument on TIMED during July-September, 2002

Coupling between the troposphere and lower thermosphere due to upward-propagating tides is investigated using temperatures measured from the SABER instrument on the TIMED satellite. The data analyzed here are confined to 20-120 km altitude and +/-40 deg latitude during 20 July 20 September, 2002. Apart from the migrating (sun-synchronous) tidal components, the predominant feature seen (from the satellite frame) during this period is a wave-4 structure in longitude with extrema of up to +/-40-50 K at 110 km. Amplitudes and longitudes of maxima of this structure evolve as the satellite precesses in local time, and as the wave(s) responsible for this structure vary with time. The primary wave responsible for the wave-4 pattern is the eastward-propagating diurnal tide with zonal wavenumber s=3 (DE3). Its average amplitude distribution over the interval is quasi-symmetric about the equator, similar to that of a Kelvin wave, with maximum of about 20 K at 5 deg S and 110 km. DE3 is primarily excited by latent heating due to deep tropical convection in the troposphere. It is demonstrated that existence of DE3 is intimately connected with the predominant wave-4 longitude distribution of topography and land-sea difference at low latitudes, and an analogy is drawn with the strong presence of DE1 in Mars atmosphere, the predominant wave-2 topography on Mars, and the wave-2 patterns that dominate density measurements from the Mars Global Surveyor (MGS) spacecraft near 130 km. Additional diurnal, semidiurnal and terdiurnal nonmigrating tides are also revealed in the present study. These tidal components are most likely excited by nonlinear interactions between their migrating counterparts and the stationary planetary wave with s=1 known to exist in the Southern Hemisphere during this period just prior to the austral mid-winter stratospheric warming of 2002.

Forbes, J. M.↗

Measuring moisture in the atmosphere

Report describes instruments for measuring moisture in air by categorizing instruments according to their thermodynamic, hygroscopic, condensation, absorption, diffusion, and optical properties.

Johnson, D. L.↗

X-ray reflectometer for optical efficiency and scatter measurements

An instrument has been developed to determine the reflection efficiency and scatter characteristics of optical samples at X-ray wavelengths from 1.5 to 113 A. The reflectometer operates in an oil-free vacuum chamber and measures the reflection efficiency and scatter characteristics as a function of the angle of incidence. The reflection efficiency is given for 8.34-A radiation incident on a fused silica sample finished to a flatness of one-tenth of a wavelength. The experimental reflection efficiency is compared with the theoretical data. The scatter curves are given for the direct X-ray beam and for the beam reflected from the fused silica sample at an angle of incidence of 50 arcmin. The full-width-at-half-maximum (FWHM) resolution of the instrument is approximately 13 arcsec, as determined by a least-squares smoothing of the experimental data.

Reynolds, J. M.↗